• Title/Summary/Keyword: treatment device

Search Result 1,531, Processing Time 0.031 seconds

Study on the Bonding Process between Thin film and Piezoelectric Materials (박막과 압전 재료 결합에 관한 연구)

  • Chong, Woo-Suk;Kim, Gi-Beum;Hong, Chul-Un
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.11
    • /
    • pp.1014-1018
    • /
    • 2005
  • The purpose of this study is to obtain strong bond strength at the interface between piezoelectric substrates and semiconductor thin films to be applied for the manufacture of high-performance acoustic wave semiconductor coupled device. For this purpose, we have compared and examined the effects of different surface treatment methods on hydrophile properties at the surface of the piezoelectric substrates. Moreover, we have observed the effect of microwave and laser on the elimination of water molecules at the interface. As for the piezoelectric substrates, dry method for surface treatment was found to be superior in the control of hydrophilicity of the surface compared to wet method. On the other hand, both microwave and laser were found to be effective in the elimination of water molecules in the interface.

Improved Stability of Atomic Layer Deposited ZnO Thin Film Transistor by Intercycle Oxidation

  • Oh, Him-Chan;KoPark, Sang-Hee;Ryu, Min-Ki;Hwang, Chi-Sun;Yang, Shin-Hyuk;Kwon, Oh-Sang
    • ETRI Journal
    • /
    • v.34 no.2
    • /
    • pp.280-283
    • /
    • 2012
  • By inserting $H_2O$ treatment steps during atomic layer deposition of a ZnO layer, the turn-on voltage shift from negative bias stress (NBS) under illumination was reduced considerably compared to that of a device that has a continuously grown ZnO layer without any treatment steps. Meanwhile, treatment steps without introducing reactive gases, and simply staying under a low working pressure, aggravated the instability under illuminated NBS due to an increase of oxygen vacancy concentration in the ZnO layer. From the experiment results, additional oxidation of the ZnO channel layer is proven to be effective in improving the stability against illuminated NBS.

Analysis on the effect of harmonics filter applied to water treatment facilities (고조파 저감장치 현장적용 효과 분석)

  • Lee Eun Chun;Byun Il Hwan;Shin Gang Wook;Hong Sung Taek;Lee Eun Woong
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.273-275
    • /
    • 2004
  • Recently, many water treatment facilities are operated by automatic control or by remote control. These high technology control systems require more stable power supply than before Badly most automatic control systems adopted in water treatment facilities are non-linear load which generates electrical harmonics inevitably. This study is intended to measure and analyze the electrical harmonics occurred at the chemicals control device which is inverter application circuit. and to show the effect of the harmonics filter.

  • PDF

Evaluation of Lubrication Performance by Laser Texturing Surface Treatment Patterns through Ring Compression Tests (링 압축 시험을 이용한 레이저 텍스처링 표면처리 패턴별 윤활성능 평가)

  • J. S. Choi;W. J. Song
    • Transactions of Materials Processing
    • /
    • v.33 no.4
    • /
    • pp.291-300
    • /
    • 2024
  • To compare the lubrication performance improvement of different laser texturing surface treatment patterns, ring-shaped specimens were prepared by processing line and dot patterns using a fiber laser device. Ring compression tests were conducted to compare the reduction rates of the inner diameter corresponding to the same height reduction of the specimens. Laser processing conditions were set to create patterns with a depth of 9㎛ and a width of 45㎛. Ring specimens were processed with varying spacings between dots and lines. The forging lubricant TECTYL FORM CF 351S was uniformly applied to the upper and lower compression tools, and the rings were compressed by 40% using a hydraulic press, after which the inner diameter was measured. The comparison of inner diameter reduction rates indicated that pattern processing improves lubrication performance, with line patterns being more effective than dot patterns in enhancing lubrication performance.

Objective Analysis of the Set-up Error and Tumor Movement in Lung Cancer Patients using Electronic Portal Imaging Device (폐암 환자에서 Electronic Portal Imaging Device를 이용한 자세 오차 및 종양 이동 거리의 객관적 측정)

  • Kim, Woo-Cheol;Chung, Eun-Ji;Lee, Chang-Geol;Chu, Sung-Sil;Kim, Gwi-Eon
    • Radiation Oncology Journal
    • /
    • v.14 no.1
    • /
    • pp.69-76
    • /
    • 1996
  • Purpose : The aim of this study is to investigate the random and systematic errors and tumor movement using electronic portal imaging device in lung cancer patients for the adequate margin in the treatment planning of 3-dimensional conformal therapy. Material and Methods : The electronic portal imaging device is matrix ion chamber type(Portal Vision, Varian). Ten patients of lung cancer treated with chest irradiation were selected for this study. Patients were treated in the supine position without immobilization device. All treatments were delivered by an 10 MV linear accelerator that had the portal imaging system mounted to its ganrty. AP or PA field Portal images were only analyzed. Radiation therapy field included the tumor, mediastinum and supraclavicular lymph nodes. A total of 103 portal images were analyzed for set-up deviation and 10 multiple images were analyzed for tumor movement because of respiration and cardiac motion. Result : The average values of setup displacements in the x, y direction was 1.41 mm, 1 78 mm, respectively. The standard deviation of systematic component was 4.63 mm, 4.11 mm along the x, y axis, respectively while the random component was 4.17 mm in the x direction and 3.31 mm in the y direction. The average displacement from respiratory movement was 12.2 mm with a standard deviation of 4.03 mm. Conclusion : The overall set-up displacement includes both random and systematic component and respiratory movement. About 10 mm, 25 mm margins along x, y axis which considered the set-up displacement and tumor movement were required for initial 3-dimensional conformal treatment planning in the lung cancer patients and portal images should be made and analyzed during first week of treatment, individually.

  • PDF

Alveolar Bone Distraction Osteogenesis at Maxillary Anterior Region for Forward-Downward Movement (상악 전치부의 전하방 이동을 위한 치조골신장술)

  • Yang, Hoon-Joo;Lee, Su-Yeon;Hwang, Soon-Jung
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.32 no.5
    • /
    • pp.459-466
    • /
    • 2010
  • Alveolar distraction osteogenesis (ADO) has been regarded as an acceptable treatment for the alveolar bone deficiency. For ADO at anterior maxillary area, the vector should be oriented to forward and down-ward direction to get an adequate occlusion with mandibular teeth and to increase bone length and width for implant placement. However, the conventional commercial distraction devices for ADO are designed to allow mainly downward movement of alveolar segment, even though a forward movement can be obtained a little by controlling of inclination of device. To make ADO with controllable bidirectional vector possible, we used customized devices using self-manufactured ABDUL (Alveolar Bone Distractor Using Lag screw principle) and commercial orthodontic palatal expansion device ($Hyrex^{(R)}$). In all cases (n = 4), ADO could be performed successfully and dental implants were able to placed with adequate occlusion. We report the procedures, advantages and disadvantages of these methods.

A Study on the Apparatus for Improving Boiler Efficiency (보일러의 효율향상(效率向上)을 위한 연소보조장치(燃燒補助裝置)에 관(關)한 연구(硏究) (연소실(練燒室) 모형(模型) 실험(實驗)))

  • Seoh, J.I.;Cho, J.H.;Lee, C.S.;Jo, J.C.
    • Solar Energy
    • /
    • v.2 no.2
    • /
    • pp.11-20
    • /
    • 1982
  • This paper presents the experimental investigations of a system as a second treatment means to increase boiler efficiency and heat transfer from combustion gas to heating surfaces in the case of spray combustion. In order to reburn residual combustible components accelerate the burning rate of sprayed fuel droplets, improve the diffusion flame and delay the residence time of the flame, advice with slit type nozzles for spouting preheated supplementary air is used in this study. In the experiment, boiler efficiency and smoke concentration in the exhaust gas at given conditions are measured in both case of installing and not-installing device in the model of combustion chamber which was designed to be equipped with five surfaces. The results obtained in this experiment are as follows ; 1. The optimum values of air rate ${\lambda}$ are about 1.3 in both case. 2. The exhaust gas temperature in the case with device increases about $30{\sim}70^{\circ}C$ above that of the case without the device. 3. Boiler efficiency and reduction effect of smoke emissions are improved considerably.

  • PDF

Development of Small-Specimen Creep Tester for Life Assessment of High Temperature Components of Power Plant (발전소 고온부의 수명 평가를 위한 소형 시편용 크리프 시험기의 개발)

  • Kim, Hyo-Jin;Jeong, Yong-Geun;Park, Jong-Jin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.10 s.181
    • /
    • pp.2597-2602
    • /
    • 2000
  • The most effective means of evaluating remaining life is through the creep testing of samples removed from the component. But sampling of large specimen from in-service component is actually impossible. So, sampling device and small-specimen creep tester have been applied. Sampling device has been devised to extract mechanically small samples by hemispherical, diamond -coated cutter from the surface of turbine rotor bores and thick-walled pipes without subsequent weld repairs requiring post weld heat treatment. A method of manufacturing small creep specimen, 2min gage diameter and 10min gage length, using electron beam welding to attach grip section, has been proven. Small-specimen creep tester has been designed to control atmosphere to prevent stress increment by oxidation during experiment. To determine whether the small specimens successfully reproduce the behavior of large specimens, creep rupture tests for small and large specimens have been performed at identical conditions. Creep rupture times based on small specimens have closely agreed within 5% error compared with that of large specimen. The errors in rupture time have decreased at longer test period. This comparison validates the procedure for fabricating and testing on small specimen. This technique offers potential as an efficient method for remaining life assessment by direct sampling from in -service high temperature components.

Leveraging the Smart device for waterworks manhole management (상수도맨홀 관리를 위한 스마트 관리장치의 활용)

  • Chun, Haebok;Kim, Yeongkwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.2
    • /
    • pp.141-148
    • /
    • 2017
  • The waterworks company is in charge of managing water facilities buried underground, and the management has been centered on manholes. However, since there is no standard management manual, it has been impossible to introduce and operate a systemized managing tool by water service providers and managers, and manhole management has been carried out by individual data recording personnel for each water service provider. When the management is carried out individually, the data to be shared by other waterworks managers tend to be privatized, and consequently, it may become a big obstacle to proceed with many civil works such as emergency leak repair, road excavation, replacement of old buildings. This report introduces RFID (Radio Frequency Identification) system which is based on the magnetic field capable of IOT. It also describes the necessity of leveraging the system for smart managing of pipe management record that has been done by hand writing. The RFID system includes RFID marker, data reader, portable computer operating program, and data base server operating program. In this system, the data is managed with a single communication device, and it would be possible to share the information on the underground facilities and water treatment facilities. This RFID technology is expected to provide water service providers with opportunities to develop more scientific and modernized underground facilities information systems.

Bridge to Transplantation with a Left Ventricular Assist Device

  • Jung, Jae-Jun;Sung, Ki-Ick;Jeong, Dong-Seop;Kim, Wook-Sung;Lee, Young-Tak;Park, Pyo-Won
    • Journal of Chest Surgery
    • /
    • v.45 no.2
    • /
    • pp.116-119
    • /
    • 2012
  • A 61-year-old female patient was diagnosed with dilated cardiomyopathy with severe left ventricle dysfunction. Two days after admission, continuous renal replacement therapy was performed due to oliguria and lactic acidosis. On the fifth day, an intra-aortic balloon pump was inserted due to low cardiac output syndrome. Beginning 4 days after admission, she was supported for 15 days thereafter with an extracorporeal left ventricular assist device (LVAD) because of heart failure with multi-organ failure. A heart transplant was performed while the patient was stabilized with the LVAD. She developed several complications after the surgery, such as cytomegalovirus pneumonia, pulmonary tuberculosis, wound dehiscence, and H1N1 infection. On postoperative day 19, she was discharged from the hospital with close follow-up and treatment for infection. She received follow-up care for 10 months without any immune rejection reaction.