• Title/Summary/Keyword: treatment device

Search Result 1,531, Processing Time 0.033 seconds

Research on the development of demand for medical and bio technology using big data (빅데이터 활용 의학·바이오 부문 사업화 가능 기술 연구)

  • Lee, Bongmun.;Nam, Gayoung;Kang, Byeong Chul;Kim, CheeYong
    • Journal of Korea Multimedia Society
    • /
    • v.25 no.2
    • /
    • pp.345-352
    • /
    • 2022
  • Conducting AI-based fusion business due to the increment of ICT fusion medical device has been expanded. In addition, AI-based medical devices help change existing medical system on treatment into the paradigm of customized treatment such as preliminary diagnosis and prevention. It will be generally promoted to the change of medical device industry. Although the current demand forecasting of medical biotechnology commercialization is based on the method of Delphi and AHP, there is a problem that it is difficult to have a generalization due to fluctuation results according to a pool of participants. Therefore, the purpose of the paper is to predict demand forecasting for identifying promising technology based on building up big data in medical biotechnology. The development method is to employ candidate technologies of keywords extracted from SCOPUS and to use word2vec for drawing analysis indicator, technological distance similarity, and recommended technological similarity of top-level items in order to achieve a reasonable result. In addition, the method builds up academic big data for 5 years (2016-2020) in order to commercialize technology excavation on demand perspective. Lastly, the paper employs global data studies in order to develop domestic and international demand for technology excavation in the medical biotechnology field.

Design and Implementation of Magnetic Stimulation Device Suitable for Herpes Zoster and Post Herpetic Neuralgia

  • Tack, Han-Ho;Kim, Gye-Sook;Kim, Whi-Young
    • Journal of Advanced Information Technology and Convergence
    • /
    • v.10 no.2
    • /
    • pp.199-214
    • /
    • 2020
  • An important technique of the present invention is primarily to parallel light detection, self-pulse therapy after diagnosis. Herpes zoster is a disease caused by varicella zoster virus, and the virus that has been latent in the dorsal root ganglion that controls the skin segment loses its immune system and physically damages it. It is an acute skin disease in which acute pain and bullous rash occur along the sensory ganglia, which are rehab by inducers such as malignant tumors. Dorsal root ganglion after complete recovery of varicella, relapsed after incubation in brain ganglion, latent virus sometimes suppressed activity by cell mediated immunity, and in cell ganglion with reduced cellular immunity. It proliferates and destroys neurons, causing pain while forming a rash and blisters. This can reduce cell necrosis and increase the phagocytosis and enzymatic activity through the movement of ions through the cell membrane, depolarization and membrane potential change, growth factor secretion, calcium ion transfer, chondrocyte synthesis, etc., And may offer treatment options for lesions of herpes zoster and post-herpetic neuralgia (PHN).Therefore, according to the present research, the diagnosis and treatment device of treating paing for herpes zoster and post-herpetic pain can be implemented in the early stage of herpes zoster, and conventional analgesic regulation, anti-inflammatory effect, post-herpetic neuralgia.

Safety and Efficacy of the Mandibular Advancement Device 'Bioguard' for the Treatment of Obstructive Sleep Apnea : A Prospective, Multi-Center, Single Group, and Non-Inferiority Trial (폐쇄성 수면무호흡증의 치료에 사용되는 하악전방이동장치-'바이오가드'의 안전성과 유효성 검증을 위한 전향적, 다기관, 단일군 및 비열등성 연구)

  • Kim, Hyoung Wook;Hwang, Chungpoong;Eun, Hun Jeong
    • Sleep Medicine and Psychophysiology
    • /
    • v.23 no.2
    • /
    • pp.84-92
    • /
    • 2016
  • Objectives: The purpose of this study was to estimate the safety and efficacy of a mandibular advancement device (MAD), 'Bioguard,' for the treatment of obstructive sleep apnea (OSA). Methods: In this 5-week prospective, multi-center, single group, and non-inferiority trial, patients who chose 'Bioguard' as their treatment option were evaluated using both questionnaires (Pittsburgh Sleep Quality Index (PSQI), Epworth sleepiness scale (ESS)) and polysomonography (PSG) (apnea hypopnea index (AHI), oxygen saturation). All patient data, including clinical records, PSG studies (both pre- and post-treatment), and adverse events (AEs), were reviewed and analyzed. Results: Results were obtained for 59 of 62 patients (95.16%). No significant difference in success rate was found between the MAD treatment and surgical treatment (95% CI). AHI, PSQI, ESS and oxygen saturation demonstrated significant improvement (p < 0.001) after MAD treatment, and 39 of 62 patients (62.9%) reported 85 AEs. 79 of the 85 AEs (91.8%) were mild cases, and there were no severe AEs related to the MAD treatment. Conclusion: The MAD 'Bioguard' should be considered as an alternative treatment option for OSA patients.

High Performance InGaZnO Thin Film Transistor by Atmospheric Pressure Ar Plasma Treatment (대기압 아르곤 플라즈마 처리를 통한 IGZO TFT의 전기적 특성 향상 연구)

  • Jeong, Byung-Jun;Jeong, Jun-Kyo;Park, Jung-Hyun;Kim, Yu-Jung;Lee, Hi-Deok;Choi, Ho-Suk;Lee, Ga-Won
    • Journal of the Semiconductor & Display Technology
    • /
    • v.16 no.4
    • /
    • pp.59-62
    • /
    • 2017
  • In this paper, atmospheric pressure plasma treatment was proposed for high performance indium gallium zinc oxide thin film transistor (IGZO TFT). RF Ar plasma treatment is performed at room temperature under atmospheric pressure as a simple and cost effective channel surface treatment method. The experimental results show that field effect mobility can be enhanced by $2.51cm^2/V{\cdot}s$ from $1.69cm^2/V{\cdot}s$ to $4.20cm^2/V{\cdot}s$ compared with a conventional device without plasma treatment. From X-ray photoelectron spectroscopy (XPS) analysis, the increase of oxygen vacancies and decrease of metal-oxide bonding are observed, which suggests that the suggested atmospheric Ar plasma treatment is a cost-effective useful process method to control the IGZO TFT performance.

  • PDF

Pulping Properties of Bast Fibers of Paper Mulberry by Pre-steaming and 2-stage Cooking System (증기 전처리 및 2단 증해 시스템에 의한 닥 인피부의 펄프화 특성)

  • Hwang, Ji Hyun;Seo, Jin Ho;Kim, Hyoung Jin
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.45 no.1
    • /
    • pp.75-82
    • /
    • 2013
  • The traditional Hanji-making was confronted with lots of industrial disadvantages and economic problems, due to the original hand-made process. Recently, the studies on the automation of overall Hanji manufacturing process is carried out by applying the commercial chemical pulping method in order to expand industrial application or efficiency of non-wood fibrous materials. However, the application of commercial pulping methods to the bast tissues of paper mulberry leads to the chemical and mechanical deterioration of cellulosic fibers. In this study, the optimal cooking method using the bast parts of paper mulberry produced by an auto-scraping device was applied to minimize the damage of fiber strength for the paper yarn manufacture. The pre-steaming treatment and alkaline pulping systems were evaluated in removal efficiency of lignin and pectin materials within the bast tissue of paper mulberry. With the application of pre-steaming treatment and 2 stage pulping system using potassium carbonate and then sodium hydroxide, kappa values were decreased two times more in lignin removal than the single stage of pulping method. It was also identified from SEM images and ATR-FTIR spectra that the pectin components within cellular structure of bast tissue were easily removed and the debarked bast parts by a auto-scraping device were easily defiberized by 2-stage pulping sequence using potassium carbonate/sodium hydroxide pulping system.

Development of Coolant/Waste-oil Separating and Cooling System with Chip Treatment (칩 처리가 포함된 절삭유/폐유 분리 및 냉각 시스템 개발)

  • Kim, Joong-Seon;Lee, Dong-Seop;Wang, Duck-Hyun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.16 no.3
    • /
    • pp.16-23
    • /
    • 2017
  • For most machine tools, it is necessary to remove chips and coolant oil because it they will continue to be created during the manufacture of workpieces. Existing products that are in use are installed and used as they reflect depending on the characteristics of each device separately. This study proposes a method to remove the security chip as well as developing an integrated system capable of reducing coolant damage. The Leverage AutoCAD and CATIA program was used for 2D and 3D design, shapes were identified by utilizing the KeyShot program, and the load and displacement analysis of the development apparatus was performed utilizing the ANSYS program. After the prototype underwent sufficient design review, the mixed oil separation device had a complete sensor control program using the LabVIEW program. The chip design process for transferring experiments and experiments on the mixed oil cooling device were developed for performance tests of the product. The final product resulted in an increase in space utilization during commercialization, reduced installation costs, and caused social effects such as pulmonary flow reduction, which, through the economic costs, reduces pollution, resulting in various benefits to the industry, such as deceased errors in the workplace decreases.

Novel Anti-Angiogenic Activity in Rubus coreanus Miquel Water Extract Suppresses VEGF-Induced Angiogenesis

  • Kim, Eok-Cheon;Kim, Hye Jin;Kim, Tack-Joong
    • Biomedical Science Letters
    • /
    • v.20 no.4
    • /
    • pp.209-220
    • /
    • 2014
  • Vascular endothelial growth factor (VEGF) is a key factor involved in the induction of angiogenesis and has become an attractive target for anti-angiogenesis therapies. The purpose of this study was to elucidate the anti-angiogenic activity of Rubus coreanus Miquel water extract (RCME). Rubus coreanus Miquel has long been employed as a traditional medicine, and recent studies have demonstrated that it has measureable biological activities. Thus, we investigated for the first time the effect of RCME on angiogenesis and its underlying signaling pathways. The effects of RCME were tested on in vitro models of angiogenesis, namely, proliferation, migration, invasion and tube formation of human umbilical vein endothelial cells as well as an ex vivo model of vessel sprouting from the rat aorta in response to VEGF. We observed that VEGF-induced angiogenesis was strongly suppressed by RCME treatment compared to that of the control group. Moreover, we found that RCME inhibited VEGF-induced activation of matrix metalloproteinases and phosphorylation of extracellular signal-regulated kinase and p38, and also effectively inhibited phosphorylation of VEGF receptor 2. These results indicated that RCME inhibits angiogenesis by suppressing phosphorylation of the VEGF receptor and may be useful for the treatment of angiogenesis-dependent diseases such as cancer and diabetic retinopathy.

A Study on the Development of an Energy Saving Ballast Water Treatment Device (I) (에너지 절감형 평형수 처리장치 개발에 관한 연구 (I))

  • Park, Dae-Won;Kil, Gyung-Suk;Choi, Yong-Ki;Choi, Chul-Young;Chang, Ji-Ho;Cheon, Sang-Gyu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.6
    • /
    • pp.880-886
    • /
    • 2010
  • In this paper, we studied the application of low pressure ultra-violet (UV) lamps for the development of an energy saving ship's ballast water treat (BWT) device. We proposed the optimal arrangement of UV lamps by analyzing the energy radiated from medium- and low-pressure UV lamps. Based on the experimental results, we manufactured a disinfection chamber which is composed of low-pressure UV lamps. The rated power and the treatment capacity of the chamber are 216 [W] and 10 [$m^3$/h], respectively. This can replace a disinfection chamber treated by two 2 [kW] medium pressure lamps. The disinfection performance, however the power consumption is about one-eighteen compare to the medium pressure UV lamp, is over 94 [%] for bacteria, 93 [%] for zooplankton, and 94 [%] for phytoplankton. Therefore, it would be possible to develop an energy saving BWT device in a low capacity below 100 [$m^3$/h].

Treatment of the Superior Sagittal Sinus Thrombosis with the Mechanical Thrombectomy Using Stent-Retriever Device

  • Kim, Hoon;Kim, Seong Rim;Park, Ik Seong;Kim, Young Woo
    • Journal of Korean Neurosurgical Society
    • /
    • v.59 no.5
    • /
    • pp.518-520
    • /
    • 2016
  • Cerebral venous sinus thrombosisis an uncommon entity and its clinical presentations are highly variable. We present the case of superior sagittal sinus thrombosis. Although it was medical refractory, successfully treated with mechanical thrombectomy using the Solitaire FR device. A 27-year-old man who presented with venous infarction accompanied by petechial hemorrhage secondary to the superior sagittal sinus (SSS) thrombosis. Due to rapid deterioration despite of anticoagulation therapy, the patient was taken for endovascular treatment. We deployed the Solitaire FR device ($4{\times}20mm$) in the anterior portion of the thrombosed SSS, and it was left for ten minutes before the retraction. Thus, we removed a small amount of thrombus. But the sinus remained occluded. We therefore performed the thrombectomy using the same methods using the Solitaire FR ($6{\times}20mm$). Thus, we were successful in removing larger clots. Our case highlights not only that the mechanical thrombectomy using the Solitaire FR is effective in achieving revascularization both rapidly and efficiently available, but also that it might be another option in patients with cerebral venous sinus thrombosis who concurrently had rapid clinical deterioration with devastating consequences.

Clinical outcome of transcatheter closure of patent ductus arteriosus in small children weighing 10 kg or less

  • Park, Young-A;Kim, Nam-Kyun;Park, Su-Jin;Yun, Bong-Sic;Choi, Jae-Young;Sul, Jun-Hee
    • Clinical and Experimental Pediatrics
    • /
    • v.53 no.12
    • /
    • pp.1012-1017
    • /
    • 2010
  • Purpose: Transcatheter closure has become an effective therapy in most patients with patent ductus arteriosus (PDA). However, there are difficulties in transcatheter closure of PDA in small children. We reviewed clinical outcomes of transcatheter closure of PDA in children weighing less than 10 kg in a single center. Methods: Between January 2003 and December 2009, 314 patients with PDA underwent transcatheter closure in our institute. Among them, 115 weighed less than 10 kg. All of these patients underwent transcatheter closure of PDA using either COOK Detachable $Coil^{(R)}$, PFM Nit-$Occlud^{(R)}$, or Amplatzer duct $occluder^{(R)}$. A retrospective review of the treatment results and complications was performed. Results: The mean age of patients was $9.1{\pm}5.9$ months (median, 8 months), and mean weight was $7.6{\pm}1.8kg$ (median, 7.8 kg). The mean diameter of PDA was $3.2{\pm}1.4mm$ (median, 3 mm). Complete occlusion occurred in 113 patients (98%). One patient was sent to surgery because of a failed attempt at device closure, and another patient had a small residual shunt after device placement. The average mean length of hospital stay was $3.0{\pm}3.3$ days, and mean follow-up duration was $21.0{\pm}19.6$ months. There were no major complications in any of the patients. Conclusion: Transcatheter closure of PDA is considered safe and efficacious in infants weighing less than 10 kg. With sufficient experience and further effort, transcatheter closure of PDA can be accepted as the gold standard of treatment for this group of patients.