• Title/Summary/Keyword: treatment device

Search Result 1,531, Processing Time 0.032 seconds

Reelection Device for Dyeability of Cotton Fabrics with Chestnut Husk Extract by Bean Sap Pre-treatment (밤 외피 추출물을 이용한 면직물 염색에서의 두즙 전처리효과)

  • 김병미
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.5 no.3
    • /
    • pp.15-23
    • /
    • 2003
  • Chestnut trees have been used as a dyeing material, which are grow naturally, are cultivated all the area of Korea. So, there is abundant amount of the materials and they have better colorfastness than other natural dyeing materials. But chestnut husk extract is good at silk and wool fabrics, not cotton fabrics. That's why many methods using chestnut extraction for dyeing are being studied. But most of them depend on treatment method with chemical material which doesn't fit with the aim, using natural materials. Therefore in this research, we used protein pre-treatment method which is dyeing chestnut husk extract after treating at cotton fabrics with bean sap. And we studied the effect of dyeability of chestnut husk extract to cotton fabrics. As a result of pre-treatment of bean sap at cotton fabrics, dyeability was increased. Besides laundering fastness, dry cleaning fastness, perspiration fastness and light fastness were almost increased.

  • PDF

Evaluation of Muscle Tension in Hemiplegia Patients with a Real-time Monitoring System during High Intensity Laser Therapy

  • Lee, Sang-Kwan;Lee, Hyeong-O;Youn, Jong-In
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.3
    • /
    • pp.277-283
    • /
    • 2015
  • In this study, we evaluated the muscle tension in hemiplegia patients using a real-time monitoring system combined with high-intensity laser treatment (HILT) device. Five hemiplegia patients were treated with HILT in the left forearm muscle for 8 minutes, and the muscle was relaxed for 8 minutes following the treatment. Both the gradient of the force-displacement curves and the muscle hardness decreased during the therapy, and the effects were maintained following the treatment. The results show that muscle tension decreased rapidly during laser irradiation, and the efficacy of the treatment depended on the duration of the illness. Consequently, we conclude that this combined HILT and real-time muscle tension monitoring system is useful for evaluating the therapeutic procedure and for treatment of muscle pain.

A New Treatment for Severe Incurved Toenail (2 Cases Report) (중증 내향성 족지 발톱의 새로운 치료 (2예 보고))

  • Kim, J-Young
    • Journal of Korean Foot and Ankle Society
    • /
    • v.12 no.1
    • /
    • pp.100-105
    • /
    • 2008
  • Partial toenail ablation on both sides of the great toenail, unfolding the severely curved toenail, and application of a simple device for maintaining the unfolded state of the incurved toenail is described to treat severely incurved toenails (pincer nails). This technique alleviated symptoms and improved the shape of severely curved toenails of the greater toe.

  • PDF

A Study on Surface Tension Measurement for the Water through Electro-Magnetic Field (전자장을 통과한 물의 표면장력 측정에 대한 연구)

  • 고영하
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.27 no.7
    • /
    • pp.826-831
    • /
    • 2003
  • The purpose of this study was to measure the surface tension of hard water through electro-magnetic field for investigating the effect of electro-magnetic water treatment. The maximum reduction of surface tension was 8% comparing to the no treatment case. When the flow velocity through the permanent magnetic device (PMD) was 6.3 m/s, sample of hard water had the minimum surface tension.

An Electrolytic Treatment of Shipboard Sewage by Using DSA Electrode (I) -Batch Electrolytic Treatment- (DSA 전극에 의한 선박오폐수의 전해처리(I)-회분식 전해처리-)

  • 김인수;조권희;남청도
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.3 no.2
    • /
    • pp.69-76
    • /
    • 1997
  • Each factor for the most effective electrolytic reaction in treating shipboard sewage was enhanced by means of batch electrolyitc reactor using DSA electrode. The effective clearance was 6mm and pH was 5-6. In such case, more than 20% of sea water concentration was needed to attain 90% of COD removal rate. The suspended solids was effectively removed by electro-floatation in proportion as charged current density. The nitrogen and posporous were effectively removed in the electrolytic device when mixed seawater.

  • PDF

Oxide Semiconductor TFTs for the Next Generation LCD-TV Applications

  • Lee, Je-Hun;Kim, Do-Hyun;Yang, Dong-Ju;Hong, Sun-Young;Yoon, Kap-Soo;Hong, Pil-Soon;Jeong, Chang-Oh;Lee, Woo-Geun;Song, Jin-Ho;Kim, Shi-Yul;Kim, Sang-Soo;Son, Kyoung-Seok;Kim, Tae-Sang;Kwon, Jang-Yeon;Lee, Sang-Yoon
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.1203-1207
    • /
    • 2008
  • For a large sized, ultra definition (UD) and high refresh rate for motion blur free AMLCD TVs, amorphous IGZO thin film transistor (TFT) are applied and investigated in terms of threshold voltage ($V_{th}$) shift influenced by active layer thickness uniformity, source drain etching technology, heat treatment and passivation condition. Optimizing above parameters, we fabricated the world's largest 15 inch XGA AMLCD successfully.

  • PDF

The First Pediatric Heart Transplantation Bridged by a Durable Left Ventricular Assist Device in Korea

  • Shin, Jung Hoon;Park, Han Ki;Jung, Se Yong;Kim, Ah Young;Jung, Jo Won;Shin, Yu Rim
    • Journal of Chest Surgery
    • /
    • v.53 no.2
    • /
    • pp.79-81
    • /
    • 2020
  • Treatment options for children with end-stage heart failure are limited. We report the first case of a successful pediatric heart transplantation bridged with a durable left ventricular assist device in Korea. A 10-month-old female infant with dilated cardiomyopathy and left ventricular non-compaction was listed for heart transplantation. During the waiting period, the patient's status deteriorated. Therefore, we decided to provide support with a durable left ventricular assist device as a bridge to transplantation. The patient was successfully bridged to heart transplantation with effective support and without any major adverse events.

Effects of Feedback Respiratory Exercise and Diaphragm Respiratory Exercise on the Pulmonary Functions of Chronic Stroke Patients

  • Seo, Kyo Chul;Kim, Hyeon Ae;Lim, Sang Wan
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.3 no.2
    • /
    • pp.458-463
    • /
    • 2012
  • This study is to examine the effects of a feedback breathing device exercise and diaphragm breathing exercise on pulmonary functions of chronic strokes patients. The selection of 20 subjects was divided equally and placed into a experiment group and a control group and the intervention was applied four times per a week for five weeks. In each session, both groups received rehabilitative exercise treatment for 30 minutes, and a feedback breathing device exercise for 15 minutes. In addition, experimental group conducted a combination of diaphragm breathing exercise for 15 minutes. Prior to and after the experiment, patients' pulmonary functions were measured using a spirometer. The pulmonary function tests included FVC, FEV1, FEV1/FVC, PEF, VC, TV, IC, ERV, IRV. With respect to changes in the pulmonary functions of both groups, the experimental group significantly differed in FVC, FEV1, TV, ERV but did not in PEF, FEV1/FVC, VC, IRV. The control group did not significantly differ in any of the tests. There were significant differences in FEV1, FEV1/FVC, TV, ERV between the two groups, but no significant differences in FVC, PEF, FEV1/FVC, VC, IRV between them after the experiment. The experimental group, which conducted a combination of a feedback breathing device exercise and diaphragm breathing exercise, saw their respiratory ability increase more significantly than the control group. The breathing exercise was found to improve pulmonary function in chronic stroke patients.

Study of Efficiency Test Evaluations Method for Imaging Device Based Laser Equipment (영상장치 기반 정밀치료용 레이저 수술기의 성능 평가 방법 개발)

  • Kim, Dae Chang;Lee, Seung Bong;Jeong, Jae Hoon;Kim, Sung Min
    • Journal of Biomedical Engineering Research
    • /
    • v.40 no.6
    • /
    • pp.230-234
    • /
    • 2019
  • Medical laser equipment using optical energy is used to surgery and treat diseases by destroying and removing tissue. Domestic laser equipment has been used steadily in the skin and cosmetics sectors and has been changed to radiate high-power energy in a wide range to shorten patient treatment time. However, side effects such as burns and damage of normal tissues occurred. To solve this problem, techniques for detecting lesions using an imaging device and selectively radiating the laser have been developed. In this study, we proposed an evaluation method to evaluate the safety and performance of target detection accuracy, laser irradiation accuracy and motion protection device technology derived from product analysis and investigation. Finally, the validity of the evaluation method was evaluated by evaluating the imaging device based laser equipment as the proposed evaluation method.

A Study on High Speed Transmission System of Medical Information Based on PXA255 (PXA255기반 의료정보 고속 전송 시스템에 관한 연구)

  • Han Young-Jae;Yu Ho-Jun;Kim Young-Kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2006.05a
    • /
    • pp.386-389
    • /
    • 2006
  • At ubiquitous environment of the future, the platform that is mobile and suitable in such environment transmit and receive many data freely. In medical treatment field, medical device with advancement of the sensor and multimedia technique will develop as the household and hand-held device. So It will be developed as the health care device easily exchanging data to other devices and transmitting information of medical device to server. In this paper, currently the mobile platform based on the PXA255 such as a powerful microprocessor which connected the WLAN for guaranteeing a mobility and a speed transmits medical information to hospital server. It put an importance in providing the system for an efficient service.

  • PDF