• Title/Summary/Keyword: treatment device

Search Result 1,531, Processing Time 0.032 seconds

A Study of Efficacy of Physical Water Treatment Devices for Mineral Fouling Mitigation Using Artificial Hard Water (인공 경수를 이용한 미네랄 파울링 저감에 물리적 수처리 기기들의 효과에 관한 연구)

  • Pak, Bock Choon;Kim, Sun Do;Baek, Byung Joon;Lee, Dong Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.11 s.242
    • /
    • pp.1229-1238
    • /
    • 2005
  • The objective of the present study was to investigate the efficacy of physical water treatment (PWT) technologies using different catalytic materials and an electronic anti-fouling device in the mitigation of mineral fouling in a once-through flow system with mini-channel heat exchanger. Effects of flow velocity and water hardness on the effectiveness of PWT technologies were experimentally studied. The artificial water hardness varied from 5.0 to 10 mo1/m$^{3}$ as CaCO$_{3}$. For 10 mo1/m$^{3}$ solution, fouling resistance reduced by 13-40$\%$ depending on flow velocity and types of PWT devices. On the other hand, fouling resistance reduced by 21-29$\%$ depending on the PWT devices for 5 mo11m3 solutions. The PWT device using alloy of Cu and Zn as catalyst (CM2) was slightly more effective than the others. SEM photographs of scale produced from the 10 mol/m$^{3}$ solution at 1.0 m/s indicated that calcium carbonate scales without PWT devices were needle-shaped aragonite, which is sticky, dense and difficult to remove. Scales with the PWT devices showed a cluster of spherical or elliptic shape crystals. Both the heat transfer test results and SEM photographs strongly support the efficacy of PWT technologies using catalytic materials and an electronic anti-fouling device in the mitigation of mineral fouling.

Analysis of the influence degree of each factor on the linkage affecting the lever actuating force in an implant transport device for the treatment of eye diseases (안과질환 처치를 위한 임플란트 수송장치에서 레버 작동력에 영향을 주는 연동장치에 대한 인자별 영향도 분석 )

  • Jeong-Won Lee;Joong-Seob Guk
    • Design & Manufacturing
    • /
    • v.18 no.3
    • /
    • pp.1-8
    • /
    • 2024
  • Macular degeneration is a disease that damages the macula, the center of the retina, and is one of the three major eye diseases along with glaucoma and diabetic retinopathy. The optic nerve and most of the photoreceptor cells are located here, and since this is where images of objects are formed, it is the most important area for vision. The main symptom of macular degeneration is the inability to clearly distinguish the shape of objects or the inability to distinguish colors and light and dark. It is also a serious eye disease that causes black spots in the center of the field of vision. However, it is difficult to distinguish it from the form of vision loss due to presbyopia, so early diagnosis is often missed. The most common treatment for macular degeneration is antibody injection therapy. This treatment requires regular injections once every 1-2 months. When receiving antibody injection therapy, the fear of having to inject directly into the eye and the cost of long-term repeated procedures are a great burden to patients. To overcome these problems, special sustained-release formulations using drug delivery systems are being developed. Since the release speed and release time of the drug can be controlled, the number of times the drug is administered can be drastically reduced. However, the implant (Ø 0.46×6.0mm), which is a sustained-release agent, is manufactured by mixing biodegradable resin (PLGA) and therapeutic agent in a ratio of 4:6, so it is very brittle and there is a high risk of implant damage during handling. In order to safely insert the implant into the eye, a transport device that can be driven with controlled force is required. Therefore, in this study, the lever operating force was measured and analyzed to determine the influence of factors according to the cross-sectional thickness and shape of the linkage produced through injection molding as well as the post-process.

Development of the closed-loop Joule-Thomson cryoablation device for long area cooling

  • Lee, Cheonkyu;Park, Inmyong;Yoo, Donggyu;Jeong, Sangkwon;Park, Sang Woo
    • Progress in Superconductivity and Cryogenics
    • /
    • v.15 no.3
    • /
    • pp.40-48
    • /
    • 2013
  • Cryoablation device is a surgical instrument to produce the cooling effect to destroy detrimental biological tissue by utilizing low temperature around 110 K. Usually, this device has the concentrated cooling region, so that it is suitable for concentrated and thick target. Accordingly, it is hard to apply this device for the target which is distributed and thin target. In this study, the design procedure of a closed-loop cryoablation device with multiple J-T expansion part is developed for the treatment of incompetent of great saphenous vein. The developed cyoablation device is designed with the analysis of 1-dimensional (1-D) bio-heat equation. The energy balance is considered to determine the minimum mass flow rate of refrigerant for consecutive flow boiling to develop the uniform cooling temperature. Azeotropic mixed refrigerant R410A and zeotropic mixed refrigerant (MR) of R22 ($CHClF_2$) and R23 ($CHF_3$) are utilized as operating fluids of the developed cryoablation device to form the sufficient temperature and to verify the quality of the inside of cryoablation probe. The experimental results of R410A and the zeotropic MR show the temperature non-uniformity over the range are $244.8K{\pm}2.7K$ and $239.8K{\pm}4.7K$ respectively. The experimental results demonstrate that the probe experiences the consecutive flow boiling over the target range of 200 mm.

Study on the Hydrogen Treatment Effect of Vacuum deposited Pentacene Thin Film Transistors

  • Lee, Joo-Won;Chang, Jae-Won;Kim, Hoon;Kim, Kwang-Ho;Kim, Jai-Kyeong;Kim, Young-Chul;Lee, Yun-Hi;Jang, Jin;Ju, Byeong-Kwon
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.668-672
    • /
    • 2003
  • In order to reach the high electrical quality of organic thin film transistors (OTFTs) such as high mobility and on-off current ratio, it is strongly desirable to study the enhancement of electrical properties in OTFTs. Here, we report the novel method of hydrogen $(H_{2})$ plasma treatment to improve electrical properties in inverted staggered OTFTs based on pentacene as active layer. To certify the effect of this method, we compared the electrical properties of normal device as a reference with those of device using the novel method. In result, the normal device as a reference making no use of this method exhibited a field effect mobility of 0.055 $cm^{2}/Vs$, on/off current ratio of $10^{3}$, threshold voltage of -4.5 V, and subthreshold slope of 7.6 V/dec. While the device using the novel method exhibited a field effect mobility of 0.174 $cm^{2}/Vs$, on/off current ratio of $10^{6}$. threshold voltage of -0.5 V, and subthreshold slope of 1.49 V/dec. According to these results, we have found the electrical performances in inverted staggered pentacene TFT owing to this novel method are remarkably enhanced. So, this method plays a key role in highly improving the electric performance of OTFTs. Moreover, this method is the first time yet reported for any OTFTs

  • PDF

Effect of Using Progesterone Releasing Intravaginal Device with Ovsynch Program on Reproduction in Dairy Cattle during Summer Season

  • Alnimer, M.;Lubbadeh, W.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.16 no.9
    • /
    • pp.1268-1273
    • /
    • 2003
  • Sixty postpartum lactating Friesian cows in 3 treatments at a commercial dairy farm were used to study the effect of using progesterone supplementation with GnRH and PGF2$\alpha$ synchronization with and without timed AI on fertility during summer. Cows in treatment1($Tr_1$) and treatment2 ($Tr_1$) were fitted with progesterone releasing intravaginal device (PRID) device and injected with 10 g GnRH agonist on $51{\pm}3$ d postpartum (pp). Seven days later, PRID was removed and cows received 25 mg PGF2$\alpha$. Two days later, $Tr_1$ cows received another injection of 10 g GnRH and timed AI 16-20 h later. Control cows received only 25 mg PGF2$\alpha$ $58{\pm}3d\;pp$. $Tr_2$ and control cows were AI at detected estrus. Serum progesterone for all cows was determined on days of injection, AI and 21, 23 and 28 d postinsemination. Pregnancy rates from first AI based on serum P4 concentrations on d 21, 23 and 28 postinsemination (50, 40 and 35%) and that based on rectal palpation 40-45 d postinsemination (30, 15 and 15% for $Tr_1$, $Tr_2$ and control cows, respectively) did not differ among the three groups. Whereas, pregnancy rate at 120 d pp for $Tr_1$ (65%) was higher (p<0.05) than that in $Tr_2$ (30%) or control (30%). The overall pregnancy rate was not significantly different (90, 90 and 75% for $Tr_1$, $Tr_2$ and control, respectively). Days open for cows in $Tr_1$ ($100.3{\pm}9$) was less (p<0.03) than that in $Tr_2$ ($130.9{\pm}9$) or control ($135.1{\pm}10$). Results indicate that using PRID device with Ovsynch program had significantly increased pregnancy rate and decreased days open compared to AI at detected estrus after synchronization with GnRH, PRID and PGF2$\alpha$ or synchronization with one injection of PGF2$\alpha$.

Anomalous Effect of Hydrogenation on the Optical Characterization $In_{0.5}Ga_{0.5}As$ Quantum Dot Infrared Photodetectors (MBE로 성장된 $In_{0.5}Ga_{0.5}As/GaAs$ 양자점 원적외선 수광소자의 수소화 처리가 광학적 특성에 미치는 특이영향)

  • Lim J.Y.;Song J.D.;Choi W.J.;Cho W.J.;Lee J.I.;Yang H.S.
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.2
    • /
    • pp.223-230
    • /
    • 2006
  • We have investigated the characteristics of hydrogen (H) plasma treated quantum dot infrared photodetectors (QDIPs). The structure used in this study consists of 3 stacked, self assembled $In_{0.5}Ga_{0.5}As/GaAs$ QD layer separated by GaAs barrier layers that were grown by molecular beam epitaxy. Optical characteristics of QDIPs, such as photoluminescence (PL) spectra and photocurrent spectra, have been studied and compared with each other for the as grown and H plasma treated QDIPs. H plasma treatment, resulted in the splitting of PL peak, which can be attributed to the redistribution of the size of QDs. The activation energies estimated from the temperature dependence of integrated PL intensity for as grown and H plasma treated QDIPs are found to be in good agreement with those determined from corresponding peaks of photocurrent spectra. It is also noted that photocurrent is detected up to 130 K for the H plasma treated QDIP, suggesting the future possibility for the development of infrared photodetectors with high temperature operation.

Credibility of a Newly Developed Sham Moxibustion (피부 열전도 온도에 근거를 둔 거짓 뜸 개발 및 평가 연구)

  • Jang, Min-Ki;Yoon, Eun-Hye;Jung, Chan-Yung;Byun, Hyuk;Kim, Eun-Jung;Kim, Kyung-Ho;Kim, Kap-Sung;Lee, Seung-Deok
    • Journal of Acupuncture Research
    • /
    • v.27 no.1
    • /
    • pp.117-127
    • /
    • 2010
  • Background : To demonstrate the efficacy of moxibustion therapy, randomized controled trials are required. But, clinical trials of moxibustion had limitations due to the absence of a sham moxibustion model for an appropriate placebo. Objectives : To develop a new sham moxibustion model based on the thermal characteristics of commercial indirect moxibustion, especially temperature, and to evaluate whether it could be applied in clinical trials. Methods : By applying heat insulation, we created a sham moxibustion device that was indistinguishable from a real one with the naked eye. It also stimulated heat but had inert remedial value. A clinical trial was performed on subjects to test double blinding. The subjects were randomly assigned into two groups, a treatment group and a sham group. Acupoint Zusanli($ST_{36}$) was used in each group for 3 times. A sham acupuncture credibility questionnaire was modified into a moxibustion credibility questionnaire and was filled out after treatment. Results : No major difference was detected in the subjects' baseline data. Most subjects and practitioners could not distinguish the sham moxibustion device from the real one. But, subjects who had experience of moxibustion therapy more likely to distinguish the sham moxibustion device from the real one than subjects who didn't have experience of moxibustion therapy. The treatment group showed a significant difference in the VAS(Visual Analog Scale) for intensity of sensation during treatment than that of the sham group. Conclusions : The sham moxibustion device in this study is proved sufficient and credible to be applied in investigations of the effect of moxibustion. But it is more appropriate for the people who don't have experience of moxibustion therapy.

Implant overdenture using milled bar and attachment in partially edentulous mandible: a case report (하악 부분 무치악 환자에서 Milled Bar와 부착장치를 이용한 임플란트 피개의치 수복 증례)

  • Kim, Min-Jung;Huh, Jung-Bo;Jeong, Chang-Mo;Yun, Mi-Jung;Lee, So-Hyoun;Jo, Yong-Bum
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.1
    • /
    • pp.71-79
    • /
    • 2022
  • Excessive crown height space increases can cause crestal bone loss and screw loosening after prosthesis is placed. Milled bar and implant overdenture can be used as a treatment method for partially edentulous patients who have severe alveolar bone loss and excessive crown height space. Milled bar can provide primary splinting effect and stability between implants. Also, milled bar with additional retention device such as Advanced Dental Device-Treatment Of Choice (ADD-TOC) and magnet can provide additional retention force for implant overdenture. In this case, the patient has a partially edentulous mandible that has severe alveolar bone loss and multiple number of teeth loss after excision due to leiomyosarcoma. Because of the long-term loss of mandibular molars, the opposing teeth were extruded. Maxillary left molars were corrected to the occlusal plane through molar intrusion, and mandibular left molar region were treated with implant overdenture, using milled bar with ADD-TOC and magnet after implant placement. The clinical result was satisfactory on the aspect of esthetic and masticatory function.

Daily check device manufacture and efficiency Evaluation for daily Q.A (일일 정도관리를 위한 Daily check device 의 제작 및 효율성 평가)

  • Kim Chan Yong;Je Yeong Wan;Lee Je Hui;Park Heung Deuk
    • 대한방사선치료학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.19-22
    • /
    • 2005
  • Introduction: Daily Q.A is the important step which must be preceded in a radiation treatment. Specially, radiation output measurement and laser alignment, SSD indicator related to a patient set-up recurrence must be confirmed for a reasonable radiation treatment. Daily Q.A proceeds correctness and a prompt way, and needs an objective measurement basis. Manufacture of the device which can facilitate confirmation of output measurement and appliances check at one time was requested. Methods and Materials: Produced the phantom formal daily check device which can confirm a lot of appliances check (output measurement and laser alignment, field size, SSD indicator) with one time of set up at a time, and measurement observed a linear accelerator (4 machine) for four months and evaluated efficiency. Result: We were able to confirm an laser alignment, field size, SSD indicator check at the same time, and out put measurement was possible with the same set up, so daily Q.A time was reduced, and were able to confirm an objective basis about each item measurement. As a result of having measured for four months, output measurement within ${\pm}\;2\%$, and measured laser alignment, field size, SSD indicator in range within ${\pm}\;1mm$. Conclusion: We can enforce output measurement and appliances check conveniently and time was reduced and was able to raise efficiency of business. We were able to bring n cost reduction by substitution expensive commercialized equipment. Further It is necessary to makes a product as strong and slight materials, and improve convenience of use.

  • PDF

Study on the Improvement of Adhesion between Cu Laminate and PSR (동박과 PSR간의 접합력 향상에 관한 연구)

  • 김경섭;정승부;신영의
    • Journal of Welding and Joining
    • /
    • v.17 no.2
    • /
    • pp.61-65
    • /
    • 1999
  • Because of the need for packages which accommodate high pin count, high density and high speed device, PBGA(plastic ball grid array) package gets more spotlight. But the substrate material which is used for PBGA package is in nature susceptible to moisture penetration. The objective of the study is to find out the path of delamination in the stacked structure of substrate. To increase the adhesion between the cooper laminate and PSR(photo solder resist) which is the weakest part, experiments were performed by changing parameters of printing pre-treatment and post-treatment process. As a result of experiments, the factor effects on the adhesion between the cooper laminate and PSR is caused by all of the pre-treatment and post-treatment condition. A considerable change was observed depending on the amount of UV irradiation after thermal cure which is typical of printing post-treatment condition rather than pre-treatment condition.

  • PDF