• Title/Summary/Keyword: treatment device

Search Result 1,531, Processing Time 0.031 seconds

Stress Behavior of PSG/SiN Film for Passivation in Semiconductor Memory Device (반도체 소자의 표면보호용 PSG/SiN 절연막의 스트레스 거동)

  • Kim, Yeong-Uk;Sin, Hong-Jae;Ha, Jeong-Min;Choe, Su-Han;Lee, Jong-Gil
    • Korean Journal of Materials Research
    • /
    • v.1 no.1
    • /
    • pp.46-53
    • /
    • 1991
  • The stress of PSG (Phosphosilicate glass), USG (Undoped-silicate grass) and SiN films, which are mainly used as passivation layers in semiconductor memory devices, deposited by CVD methods has been studied as a function of film thickness and holding time in air. The stress of the PSG film or the USG film is increased in tensile state with increasing film thickness. On the other hand the stress level of the SiN film in compressive stress does not change as film thickness changes. The stress of PSG film shows the drastic change from the tensile stress to the compressive stress after the film is left 2 days in air. FTIR spectra indicated that the stress variation was due to the penetration of water molecule. It looks possible to recover the stress of about $2.5{\times}{10^9}dyne/cm^2$ by annealing treatment at $300^{\circ}C$ for 20min. The total stress of multi-layered films having the PSG film is determined mainly by the stress variation of PSG layer with holding time. The total stress of multi-layered film appears to have a functional relationship with the stress in the thickness of each film. The resistance against stress-migration of sputtered Al line increases with increasing the tensile stress for the PSG film or the USG film.

  • PDF

A study on oral health status and oral health behavior practice perceived by workers in part areas (일부 지역의 근로자가 지각하는 구강건강상태와 구강건강행위실천에 관한 연구)

  • Kim, Mi-Jeong
    • Journal of Korean society of Dental Hygiene
    • /
    • v.12 no.1
    • /
    • pp.201-212
    • /
    • 2012
  • Objectives : The purpose of this study was to examine about workers' oral health status and oral health behavior practice. Methods : Questionnaire survey was carried out targeting 331 workers within the industrial complex of Jeonju city in 2011. As a result of surveying and analyzing workers' oral health status, habit related to oral health, activity restriction, which is oral disease phase, and oral health practice level by using SPSSWIN 12.0. Results : 1. Workers' experience of visiting dental hospital(clinic) for the past one year was indicated to be the highest with 64.9% in the working period with 10 years-under 20 years(p<0.001). Experience of scaling was indicated to be averagely 38.8%. 2. The oral health status perceived by workers was the highest with 40.5% in 'having something abnormal'. A problem was the highest with 28.0% in 'dental caries'. A cause was indicated to be 42.6% in 'because of being naturally weak in tooth or the gum.' The biggest reason for having failed to receive the dental treatment at a proper time was indicated to be the highest with 24.8% in 'because of feeling burdensome about dental expense. '3. 58.4% of male workers were smoking. The use of dental hygiene device was the highest with 40.6% in mouth-rinse. 4. Absence caused by oral disease was indicated to be the highest with 13.8% in the household income in more than 3,500,000won, thereby having shown the significant difference(p<0.05). Early leaving was indicated to be the highest 13.9% in more than 50s age, thereby having shown the significant difference(p<0.05). Also, as for factors of absence and early leaving, a pain was the highest with 64.7%. 5. Workers' oral health practice level was the highest with 2.85 points in 'Brushing teeth before going to bed'. Conclusions : Synthesizing these findings, the oral management could be known to be made negligently in the workers with the older age, the lower academic background, and the lower income. The institutional foundation is considered to be necessary for which the oral health education can be efficiently performed in addition to a need of periodic oral examination for these classes.

Design of UWB/WiFi Module based Wireless Transmission for Endoscopic Camera (UWB/WiFi 모듈 기반의 내시경 카메라용 무선전송 설계)

  • Shim, Dongha;Lee, Jaegon;Yi, Jaeson;Cha, Jaesang;Kang, Mingoo
    • Journal of Internet Computing and Services
    • /
    • v.16 no.1
    • /
    • pp.1-8
    • /
    • 2015
  • Ultra-wide-angle wireless endoscopes are demonstrated in this paper. The endoscope is composed of an ultra-wide-angle camera module and wireless transmission module. A lens unit with the ultra-wide FOV of 162 degrees is designed and manufactured. The lens, image sensor, and camera processor unit are packaged together in a $3{\times}3{\times}9-cm3$ case. The wireless transmission modules are implemented based on UWB- and WiFi-based platform, respectively. The UWB-based module can transmit HD video to a computer in resolution of $2048{\times}1536$ (QXGA) and the frame rate of 15 fps in MJPEG compression mode. The maximum data transfer rate reaches 41.2 Mbps. The FOV and the resolution of the endoscope is comparable to a medical-grade endoscope. The FOV and resolution is ~3X and 16X higher than that of a commercial high-performance WiFi endoscope, respectively. The WiFi-based module streams out video to a smart device with th maximum date transfer rate of 1.5 Mbps at the resolution of $640{\times}480$ (VGA) and the frame rate of 30 fps in MJPEG compression mode. The implemented components show the feasibility of cheap medical-grade wireless electronic endoscopes, which can be effectively used in u-healthcare, emergency treatment, home-healthcare, remote diagnosis, etc.

Comparison between QraypenTM Imaging and the Conventional Methods of Visual Inspection and Periapical Radiography for Proximal Caries Detection in Primary Molars: An In Vivo Study (유구치 인접면 우식 병소 진단에 있어 QraypenTM과 시진 및 구내 치근단 방사선의 비교)

  • An, So-Youn;Park, So-Young;Shim, Youn-Soo
    • Journal of dental hygiene science
    • /
    • v.16 no.5
    • /
    • pp.349-354
    • /
    • 2016
  • The purpose of this study was to evaluate the efficacy of the newly-developed $Qraypen^{TM}$ (All In One Bio, Korea) system for the diagnosis of early proximal caries by comparing it with the conventional methods of visual inspection and periapical radiography. This study was carried out from July 2015 to April 2016 targeting 32 children aged 7~12 years who visited Y-Dental Clinic for school oral health examinations. Two investigators selected and examined a total of 153 primary molars that had not undergone restorative treatment. Comparisons were carried out between visual inspections, readings of posterior periapical radiography images, and readings of $Qraypen^{TM}$ images. This study revealed that the percentage of interproximal surfaces of primary molar teeth without caries incidence was 83.7% using $Qraypen^{TM}$ imaging and 84.9% using visual inspection and periapical radiography. The differences between the two methods were not statistically significant. Thus, $Qraypen^{TM}$ is expected to be a useful and convenient auxiliary diagnostic device that can facilitate the detection of hidden proximal caries in primary molars.

Preparation of Chitosan-coated Magnetite Nanoparticles (키토산이 피복된 나노 크기의 자성체 분말 제조)

  • Cho, Jun-Hee;Ko, Sang-Gil;Ahn, Yang-Kyu;Song, Ki-Chang;Choi, Eun-Jung
    • Journal of the Korean Magnetics Society
    • /
    • v.16 no.1
    • /
    • pp.102-106
    • /
    • 2006
  • Magnetic nanoparticles can be used for a variety of biomedical applications. They can be used in the targeted delivery of therapeutic agents in vivo, in the hyperthermic treatment of cancers. in magnetic resonance (MR) imaging as contrast agents and in the biomagnetic separations of biomolecules. We have synthesized magnetite $(Fe_3O_4)$ nanoparticles using chemical coprecipitation technique with sodium oleate as surfactant. Nanoparticle size can be varied from 2 to 8nm by controlling the sodium oleate concentration. Magnetite phase nanoparticles could be observed from X-ray diffraction. Magnetic colloid suspensions containing particles with sodium oleate and chitosan have been prepared. Nanoparticles, both oleate-coated and chitosan-coated, have been characterized by several techniques. Atomic farce microscope (AFM) was used to image the coated nanoparticles. Magnetic hysteresis measurement were performed using a superconducting quantum interference device (SQUID) magnetometer at room temperature to investigate the magnetic properties of the magnetite nanoparticles. The SQUID measurements revealed superparamagnetism of nanoparticles.

An Analysis of Fall Incidence Rate and Its Related Factors of Fall in Inpatients (입원환자 낙상 발생 실태와 원인에 관한 분석 연구)

  • Kim, Chul-Gyu;Suh, Moon-Ja
    • Quality Improvement in Health Care
    • /
    • v.9 no.2
    • /
    • pp.210-228
    • /
    • 2002
  • Background: The purpose of this research was to examine the fall incidence rate and its related factors of fall in inpatients. Methods: The data were collected from the 138 fall incident reports in one tertiary hospital in Seoul from April 1st 1999 to September 30th 2001. The Fall Incident Report Form was originally developed based on that of Massachusetts General Hospital revised in 1995. And this was modified for this survey by the collaborating work of QI team including researcher and department of nursing service of this particular hospital. The contents of Fall Incident Form were general characteristics of patient. factors related to fall. types and places of fall. circumstances, nursing interventions. and outcome. Results: 1) The incidence rate of fall was 0.08% of total discharged patients and 0.081 per 1000 patient-day. This incidence rate is much lower than that of several hospitals in USA. This finding might result from the different incidence report system of each hospital. 2) The characteristics of fall-prone patient were found as follows. They were mostly over 60 years old, in alert mental status, ambulatory with some assistance, and dependent on ambulatory device. The types of diseases related high incidence rate were cerebrovascular disease(3.2), hypertension(1.6), cardiovascular disease(1.4), diabetes(1.3) and liver disease(0.6). 3) The majority of fall events usually occurred m bed. bedside(walking or standing) and bathroom in patient room. Usually they were up on their own when they fell. And there were more falls of elderly occurred during night time than day or evening. 4) 63.8% of fall events resulted in physical injuries such as fracture and usually the patients had diagnostic procedures and some treatment(ex. suture) which caused additional cost to the patients and their families. 5) The found risk factors of fall were drugs(antihypertensive drug, diuretics) and environmental factors like too high bed height, long distance of bedside table and lamp switch, and slippery tile of bathroom floor. Conclusion: Considering these results, every medical and nursing staff should be aware of the risk factors of patients in hospital, and should intervene more actively the preventive managements, specially for the elderly patients during night. Therefore, it is recommended that the development of Fall Prevention Programs based on these results.

  • PDF

Analysis of Local Resident'S Perception on 'Rainwater for Drinking' Project in Developing Countries : Focusing on Vietnam Case Studies (개발도상국의 빗물식수화시설 사업에 대한 지역주민의 인식 분석 : 베트남 사례를 중심으로)

  • Lee, Minju;Han, Mooyoung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.1
    • /
    • pp.1-8
    • /
    • 2017
  • Drinking water deficiency is prevalent in developing countries due to contamination of surface and ground water, difficulties of water treatment, and lack of water infrastructures. 'Rainwater For Drinking (RFD)' projects are emerging as one of the effective solutions globally since RFD systems provide safe drinking water from rainwater. In RFD projects, perception of local residents toward RFD project is essential as local residents must manage their RFD systems on their own after the project finishes. This research performed survey and interview to 209 local residents, who use RFD systems, and analyzed their general perception, expected effects and feared factors toward RFD projects. Through the research, it was shown that the most of the local residents have positive perception towards RFD projects' effectiveness (41.9%) and are willing to participate (58.9%). The top three expected effect factors of the RFD projects were 'supply of safe water source', 'vitalization of local community', and 'expansion of RFD system'. The top three feared factors were 'quality of rainwater', 'technical factors of RFD system', and 'maintenance of RFD system'. The research findings indicate that development of simple water quality measuring device and education of the local residents about RFD system is necessary for better maintenance of the RFD system after the project finishes.

Study on High Degree of Efficiency Chemical Reactor for Air Purification Using the Glow Discharge (글로우 방전을 이용한 고효율 공기 정화용 화학 반응기의 특성관찰에 관한 연구)

  • Kim, Gi-Ho;Bu, Min-Ho;Lee, Sang-Cheon
    • Journal of the Korean Chemical Society
    • /
    • v.50 no.1
    • /
    • pp.14-22
    • /
    • 2006
  • the basic model of chemical reactor using glow discharge, we used cathode discharge cell with vacant cavity in the middle. Currently glow discharge is widely studied as a radiation source or atomization device in atomic spectroscopy and remarkable technological achievements are made through the graft with other analysis devices such as microanalysis and steel analysis.1 Additionally, as the characteristics of basic glow discharge and radiation have been reviewed many times, those results could be used in this experiment.2-3 In 1993, an article regarding the treatment of poisonous gas in the air using low temperature plasma was published. According to this article, if DC Glow Discharge is used under continuous atmospheric flow, poisonous gases such as SO2 and NO can be removed.4 Based on those findings, we designed highly efficient reactor where stable air plasma is composed and all air flow pass the negative glow area passing through the tube. It was observed that the cathode tube type glow discharge developed in this study would be economical, easy to use and could be used as radiation source as well.

Self-management techniques and subsequent changes in pain and function in patients with chronic low back pain (만성 요통 환자의 자가 관리 요법에 따른 통증 및 기능의 변화)

  • Choi, Jun Hyun;Kim, Eun-Shil;Yoon, Yong-Soon;Kim, Ka-Eun;Lee, Mi-Hyun;Jang, Hong-Young
    • Journal of Digital Convergence
    • /
    • v.18 no.10
    • /
    • pp.547-555
    • /
    • 2020
  • To investigate the effects of self-management programs for chronic low back pain (LBP), 63 subjects were assigned to three groups; self-exercise group (SEG), hot pack and low-frequency electrical stimulation group (HEG), and thermo-massage group (TMG). Parameters were the pain numeric rating scale (PNRS), Oswestry Disability Index (ODI), Roland Morris Disability Questionnaire (RMDQ) and Relapse frequency (RF). PNRS, ODI and RMDQ of SEG and TMG sustained effectiveness, however, PNRS, which improved after treatment in HEG, worsened in 6 month. Between the groups, all parameters were better in SEG and TMG compare to HEG. Exercise and thermo-massage can be considered as useful self-management performed at home to prevent the relapse of chronic LBP.

A SHEAR BOND STRENGTH OF RESIN CEMENT BONDED TO HUMAN UNCUT ENAMEL, CUT ENAMEL, AND DENTIN IN VITRO

  • Lee Jong-Yeop
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.3
    • /
    • pp.319-324
    • /
    • 2003
  • Statement of problem. Adhesives in dentistry playa major role in the success of restorative treatments. In the treatment of all ceramic restoration it is needed to find the adequate bond strength between enamel and dentin. Purpose. The purpose of this study was to evaluate shear bond strength of resin cement bonded to extracted human uncut enamel, cut enamel, and dentin in vitro. Material and methods. Ten freshly extracted anterior teeth without any previous restorative treatments were chosen. The extracted teeth were embedded in PMMA cold acrylic in the shape of a cylinder, 25 mm in diameter by 25 mm in height. The bonding system used was as follow: Uni-Etch (32% phosphoric acid), One-Step adhesive, Duolink resin cement. The specimens were acid etched and rinsed with water. Two layers of One-Step adhesive were coated with a disposable brush on the uncut enamel. VIP curing light at $500mV/cm^2$ was used to cure the adhesive. For cut enamel shear bond test, the specimen used for uncut enamel was further reduced approximately $0.3{\sim}0.5mm$ using a laminate preparation diamond bur (0.3 mm in depth). The specimens were subsequently treated with 320-grit SiC paper followed by 600-grit SiC paper and cleaned with distilled water. The bonding procedure on the cut enamel was same as uncut enamel bonding procedure. For dentin bonding test, the specimen used for cut enamel was further reduced approximately $0.5mm{\sim}1.0mm$ using a laminate preparation diamond bur (0.5 mm in depth of diamond cutting). The amount of reduction was evaluated with the silicone mold. The specimens were subsequently treated with 320-grit SiC paper followed by 600-grit silicon carbon paper and cleaned in distilled water. The bonding procedure on the dentin was same as uncut enamel bonding procedure. All samples were mounted and secured on the Ultradent shear bond test sample holder, and Ultradent restricted shear bond testing device was used with Universal Instron machine until fracture. Analysis of variance (ANOVA) test was performed comparing the result at P<0.05. Multiple comparison (Tukey) was used to compare each groups. Result. The result showed that the mean value in shear bond strength of resin cement bonded to uncut enamel, cut enamel and dentin were 27.04 Mpa, 30.25 Mpa and 26.39 Mpa with respect. Conclusion. Within the limitation of this study, the mean value of the shear bond strength of cut enamel was higher than those of uncut enamel or dentin. However there existed no statistical differences between three different human dentition substrates due to increased adhesive characteristics.