생물막을 이용한 침출수처리수 중의 질소제어에 관한 연구 (A Study on the Nitrogen Control in the Treated Leachate water by Bio-film Module System)

  • 최규철;이규성;정일현
    • 환경위생공학
    • /
    • 제11권1호
    • /
    • pp.71-76
    • /
    • 1996
  • Bio-film module system was applied to the treated leachate water that priorly had been treated with biological nitrification process. The experiments were performed in the laboratory and treated leachate water treatment facility. Experimental results obtained from laboratory conditions and nitrogen removal efficiencies were averaged 90% for 1 hr.

  • PDF

도시폐기물매립지침출수의 병합처리에 관한 연구 (A Study on the Combined Treatment of Municipal Solid Waste Landfill Leachate)

  • 김동민;이병인
    • 환경위생공학
    • /
    • 제11권1호
    • /
    • pp.45-55
    • /
    • 1996
  • An experimental research was conducted in order to study the combined treatment o of municipal landfill leachate and municipal sewage. The landfill leachate was that of Nanjido landfill site, and the municipal sewage was that of Chungnang municipal sewage treatment plant in Seoul. Several sets of bench~scale sequencing batch reactor(SBR) were used as e experimental apparatus. Specially investigated items in this experiment were the removal efficiency of substrate and the influence of treatment time. The experiment lasted for about 2 years. The result are as follows ; 1. The characteristics of leachate were pH 7.5~8.2, BOD 80~336mg/L, COD 908~1,460mg/L, NH3-N 1,409~2,330mg/L, T~P 2.7~7.lmg/L, Cl~3,540~4,085mg/L, a and heavy metals are a very small amount. And the characteristics of sewage were pH 6.9~7.3, BOD 78.4~129.3mg/L, COD 121.2~305.0mg/L, T~N 14.9~36.4mg/L, T-P 2.3~8.9mg/L. 2. The treatability of leachate alone was not treat well. So for the good treatment of leachate, it was necessary to deal with the pretreatment before bi이ogical treatment and a combined treatment of municipal sewage. 3. The various contents of the leachate were 5%, 10%, 30%, and 50%, and the removal efficiency of COD was 86.0%, 82.8%, 60.6%, and 31.7%. The maximum content of the leachate which could be sucessfully treated by SBR in the combined treatment was 10% of that of sewage. And the removal efficiency of COD increased n notably, as its treatment time increased. 4. The various contents of the electrolytic treated leachate were 5%, 10%, 30%, and 50%, and the removal efficiency of COD was 89.9%, 86.1%, 79.2%, and 69.8%. The maximum content of the leachate which could be sucessfully treated by SBR in the combined treatment was 30 % of that of sewage. And the removal efficiency of C COD increased notably, as its treatment time increased.

  • PDF

Removing nitrogenous compounds from landfill leachate using electrochemical techniques

  • Nanayakkara, Nadeeshani;Koralage, Asanga;Meegoda, Charuka;Kariyawasam, Supun
    • Environmental Engineering Research
    • /
    • 제24권2호
    • /
    • pp.339-346
    • /
    • 2019
  • In this research, applicability of electrochemical technology in removing nitrogenous compounds from solid waste landfill leachate was examined. Novel cathode material was developed at laboratory by introducing a Cu layer on Al substrate (Cu/Al). Al and mild steel (MS) anodes were investigated for the efficiency in removing nitrogenous compounds from actual leachate samples collected from two open dump sites. Al anode showed better performances due to the effect of better electrocoagulation at Al surface compared to that at MS anode surface. Efficiency studies were carried out at a current density of $20mA/cm^2$ and at reaction duration of 6 h. Efficiency of removing nitrate-N using Al anode and developed Cu/Al cathode was around 90%. However, for raw leachate, total nitrogen (TN) removal efficiency was only around 30%. This is due to low ammonium-N removal as a result of low oxidation ability of Al. In addition to the removal of nitrogenous compounds, reactor showed about 30% removal of total organic carbon. Subsequently, raw leachate was diluted four times, to simulate pre-treated leachate. The diluted leachate was treated and around 88% removal of TN was achieved. Therefore, it can be said that the reactor would be good as a secondary or tertiary treatment step in a leachate treatment plant.

목편살수여상 침출액비와 어분, 골분, 게껍질 혼합액을 이용한 상추의 수경재배 (Hydroponic Culture of Leaf Lettuce Using Mixtures of Fish Meal, Bone Meal, Crab Shell and the Pig Slurry Leachate of Woodchip Trickling Filter)

  • 류종원
    • 한국축산시설환경학회지
    • /
    • 제16권3호
    • /
    • pp.215-226
    • /
    • 2010
  • 본 연구는 목편살수여상 pilot 장치를 설치하여 스크레파 축사에서 배출되는 뇨오수를 원수로 사용하여 가동한 후 침출액비를 공시재료로 하여 상추 양액재배 시험을 실시하였다. 처리구는 침출액비 (SL) 단독처리구, 침출 액비+어분 (SL+FM), 침출액비+골분 (SL+BM), 침출액비+게껍질 (SL+CS) 혼합처리구. 침출 액비+부산물 (SL+FM+BM+CS) 혼합처리구, 대조구로 원예연 상추양액 (NS) 처리구 등 6개 처리구를 두었다. 침출액비와 부산물 혼합처리 후 전기전도도와 pH를 조정하여 상추의 양액재배를 실시한 결과를 요약하면 다음과 같다. 1. 목편살수여상 처리 과정중 pH는 처리 시작전 7.3에서 처리 후 8.5로 상승하였다. 전기전도도 (EC)는 처리전 17.05 mS/cm에서 처리 후 30일에는 9.7 mS/cm로 낮아졌다. 2. 침출액비는 부유물질 (SS)이 낮아 수경 재배시 관배수의 막힘문제 없이 활용이 가능하였다. 침출액비는 양분조성에서 칼륨함량이 높고 인산 함량이 낮았다. 3. 침출액비시용구 (SL)의 상추수량은 원예 연 표준양액재배 대비 75%를 나타내어 25% 수량저하를 나타내었다. 침출액비을 어분. 골분. 게껍질을 혼합한 처리구는 대조구 대비 85%. 79%. 80% 수량을 나타내어 어분의 첨가 효과가 가장 높았다. 침출액비와 어분 혼합액은 침출액비 단독처리구 보다 10% 증수를 나타내어 유기양액의 대체 원료로 사용이 가능 할 것으로 보인다.

침출수 처리 응용 펄스전원 시스템 (Pulsed Power System for Leachate Treatment Application)

  • 장성록;안석호;류홍제;임근희
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2010년도 하계학술대회 논문집
    • /
    • pp.246-247
    • /
    • 2010
  • This paper deals with the water treatment of the leachate from sewage filled ground by a pulsed power technology. Leachate from sewage filled ground should be treated below regulation level of COD in order to prevent environmental pollution and usually treated by a chemical method. Among the pollutants mixed in the leachate, chemical compounds of benzene series are known to be difficult to break down, and need to use high cost treat methods. The treatment of the benzene compounds by high power pulsed power supply was studied. For the high-rate, cost-effective treatment of leachate, pulsed power supply should have high repetition rates and require switching devices of long lifetime. In order to meet the demands of the above condition, pulsed power generator based on semiconductor switches using IGBTs as primary switches were developed. The experimental results verified that benzene compounds can be treated effectively by high voltage electric pulses, and this fact indicates that the treatment method by pulsed power source is a promising substitute.

  • PDF

다공성 Media가 조여된 반응조를 이용한 매립지 침출수의 호기성 생물학적 처리시 미소생물상의 특성 (Characteristics of Microfauna in Biological Treatment of Landfil Leachate with Reactor Including Porous Media)

  • 홍성철;박연규
    • 한국환경과학회지
    • /
    • 제5권1호
    • /
    • pp.61-69
    • /
    • 1996
  • The combined wastewater of municipal landfill leachate and municipal sewage was treated using several sets of bench-scale aerated circulating system including porous media. Investigated items in this experiment were the dominant protozoa and metazoa in this system, the variation of microfauna relationship between operating condition and dominant genera. Also considered the factors determining dominant genera and their role. The outcome of this research is as follows; 1. Aspidisca, Vorticella, Truhellophyllum, Lecane, Philodina, Cyclops were mainly appeared prior to combinding leachate, while Trachelocerca, Bodo, Glaucoma were the dominant genera after combinding leachate. 2. As to metazoa, Nematode and Philodina were not influenced by 5oA leachate mixing ratio, meanwhile Crustacea has high sensitivity for increased leachate mixing ratio and it was not appeared in 5% leachate mixing ratio. 3. The appropriate treatability could'nt be expected at the above 10% leachate mixing ratio. Especially, in the condition of 20% leachate mixing ratio, all of the microfauna were affected damage seriously on their existence. Meanwhile hydraulic retention time, substrate loading rate and slut자e production rate didn't give notable influence on increasing the number of microfauna. 4. As to protozoa, saprozoic and holozoic species were appeared commonly and polysaprobic species were dominent. 5. Filamentous organsms were nearly not affected by leachate mixing. It seems that they could live without any trouble at the 10% leachate mixing ratio, if the substrate is sufficient. 6. Diversity of microfauna had a reducing trernd as the sewage was mixed with leachate.

  • PDF

분말활성탄 접촉-응집에 의한 생활폐기물 및 산업폐기물 매립지 침출수의 처리 (Treatment of Leachate from Municipal Landfill and Industrial Landfill by PAC Adsorption-Coagulation)

  • 김수영;장덕;김영태
    • 상하수도학회지
    • /
    • 제11권4호
    • /
    • pp.110-117
    • /
    • 1997
  • Performances of combined adsorption and coagulation were evaluated as one of the options for pre-treatment or post-treatment of MSW landfills leachate and industrial landfill leachate. The COD and color removals of leachate from an old MSW landfill were 35% and 33% at an alum dose of 300mg/L with preceding PAC(powdered activated carbon) dose of 200mg/L, respectively. The COD and color removals of leachate from an young MSW landfill were 58% and 25% at an alum dose of 700mg/L and PAC dose of 500mg/L, respectively. The COD and color of biologically treated leachate from an industrial waste landfill were removed up to 32% and 68%, respectively, with pH control at addition of 500mgAlum/L and 1,000mgPAC/L. Adsorption and coagulation process with pH control showed better COD and color removals than the process without pH control for biologically treated leachate from an industrial waste landfill. The color removal was influenced greatly by pH control, while COD removal was not significant. No difference in removal efficiency was observed between adsorption-coagulation and coagulation-adsorption process. The COD removal was accomplished mainly by adsorption, while coagulation was a key mechanism of color removal. However, the mechanism of COD removal was obscure, when BOD/COD ratio was high. Maximum net increases in COD and color removals by the adsorption-coagulation process were respectively 45% and 46% compared with the unit process of adsorption or coagulation, although those removals depended on leachate characteristics. Thus, adsorption-coagulation process was considered to be effective for pre- and post-treatment of landfill leachate, and has distinct features of simple, flexible, stable and reliable operation against fluctuation leachate quality and flowrate.

  • PDF

생성 기원에 따른 용존 자연유기물질 분자량별 형광특성 비교 (Fluorescence Properties of Size Fractions of Dissolved Organic Matter Originated From Different Sources)

  • 허진;박민혜
    • 한국물환경학회지
    • /
    • 제23권4호
    • /
    • pp.482-489
    • /
    • 2007
  • Fluorescence properties and carbohydrate content were investigated using ultrafiltrated size fractions of dissolved organic matters (DOM) originated from different sources. The materials included a treated sewage, an algal organic matter, and a soil leachate, all of which are major constituents of dissolved organic matter in a typical urban river. Four different size fractions were separated from the three sources of each DOM. The size distribution demonstrated that a higher molecular weight fraction was more present in soil leachate compared to two other source DOMs. A higher content of carbohydrates was observed in the following order - algal DOM > treated sewage > soil leachate. A wide range of specific UV absorbance was observed from size fractions of a single source DOM, indicating that aromatic carbon structures are heterogeneously distributed within one source of DOM. The structural heterogeneity was the most pronounced for the soil leachate. The fluorescence index ($F_{450}/F_{500}$) of the treated sewage was similar to that (2.0) typically obtained from autochthonous DOM, suggesting that the treated sewage exhibited autochthonous organic matter-like properties. No protein-like fluorescence intensities were observed for all of the soil leachate size fractions whereas they were observed with two other source DOMs. Based upon the fluorescence peak ratios from fluorescence excitation-emission matrix (EEM), two discrimination indices could be suggested to distinguish three different source DOMs. It is expected that the suggested discrimination indices will be useful to predict the sources of DOM in a typical urban river affected by treated sewage.

Remediation capabilities of pilot-scale wetlands planted with Typha aungstifolia and Acorus calamus to treat landfill leachate

  • Bhagwat, Rohit V.;Boralkar, Dilip B.;Chavhan, Ram D.
    • Journal of Ecology and Environment
    • /
    • 제42권4호
    • /
    • pp.191-198
    • /
    • 2018
  • Improper management and unsanitary approaches are implemented in disposal of leachate, which has resulted in groundwater pollution at village Uruli Devachi, Pune, India. Various physico-chemical treatment methods are commercially available for leachate treatment. However, the application of biological methods viz. phytoremediation to the municipal solid waste landfill leachate has been limited. We report the remediation ability of Typha aungstifolia and Acrorus calamus that is capable of reducing hazardous constituents from the landfill leachate. After 96 h of hydraulic retention time (HRT), it was observed that T. aungstifolia-treated sample showed high reduction potential in reducing biochemical oxygen demand, chemical oxygen demand, hardness, total dissolved solids, Na, Mg, Ca and Ni whereas A. calamus showed greater reduction capacity for alkalinity, Cl, Cu, Zn and Cr. Furthermore, it was also observed that T. aungstifolia withstood longer HRT than A. calamus. In situ application of T. aungstifolia and A. calamus for remediation of landfill leachate carries a tremendous potential that needs to be further explored.

생물학적 방법에 의한 도시생활폐기물 매립지의 침출수 독성특성 평가 (Biological Evaluation for Characteristics of Leachate Toxicity from Municipal Solid Waste Landfill)

  • 황인영;류경무
    • Environmental Analysis Health and Toxicology
    • /
    • 제11권1_2호
    • /
    • pp.31-39
    • /
    • 1996
  • Leachate from municipal solid waste (MSW) landfill, effluent from leachate treatment plant, and ground water sample from a monitoring well near landfill site were tested for an acute toxicity. Microtox toxicity test was used for testing the acute toxicity of leachate and other samples. EC$_{50}$ values which a concentration of pollutant for reducing 50% light output from luminescent bacteria, Photobacterium phosphoreum were determined to assess the toxicity of pollutants as well as the relative toxicity. In addition, characteristics of leachate were studied and compared to those of phenol and pentachlorophenol (PCP) which are typical aquatic toxic pollutants. For leachate, EC$_{50}$ for 30 min incubation was 10.8%, while for phenol and PCP, 46 ppm and 1.2 ppm, respectively. the relative toxicity of treated leachate by in situ aeration with activated sludge was reduced to more than 75% of toxicity of the untreated leachate. Microtox toxicity test was failed to figure out EC$_{50}$ values for groundwater from a monitoring well since the relative toxicity of the unconcentrated sample was too low to estimate EC$_{50}$. Addition of activated carbon to leachate was reduced the relative toxicity. The reduction Pattern of the relative toxicity of leachate by mechanical aeration was similar to that of PCP, but different from that of phenol. These findings suggest that the toxicity of leachate may come from PCP-like toxic compounds rather than phenol-like one. In conclusion, the process of aeration with activated sludge might be very important to reduce the environmental toxicity of leachate. And Microtox test could be a reasonable bioassay for screening and monitoring the environmental toxicity of leachate from municipal solid waste landfill as well as for determining the reduction efficiency of the leachate toxicity by various treatment processes in leachate treatment plant.