• 제목/요약/키워드: transverse shear transfer

검색결과 24건 처리시간 0.017초

A piecewise linear transverse shear transfer model for bolted side-plated beams

  • Li, Ling-Zhi;Jiang, Chang-Jiu;Su, Ray Kai-Leung;Lo, Sai-Huen
    • Structural Engineering and Mechanics
    • /
    • 제62권4호
    • /
    • pp.443-453
    • /
    • 2017
  • The performance of bolted side-plated (BSP) beams is affected by the degree of transverse partial interaction, which is a result of the interfacial slip caused by transverse shear transfer between the bolted steel plates and the reinforced concrete beams. However, explicit formulae for the transverse shear transfer profile have yet to be derived. In this paper, a simplified piecewise linear shear transfer model was proposed based on force superposition principle and simplification of shear transfer profiles derived from a previous numerical study. The magnitude of shear transfer was determined by force equilibrium and displacement compatibility condition. A set of design formulae for BSP beams under several basic load cases was also derived. Then the model was verified by test results. A worked example was also provided to illustrate the application of the proposed design formulae. This paper sheds some light on the shear force transfer mechanism of anchor bolts in BSP beams, and offers a practical method to evaluate the influence of transverse partial interaction in strengthening design.

콘크리트의 전단마찰 내력에 대한 횡보강근 및 압축응력의 영향 (Effect of Shear Reinforcement and Compressive Stress on the Shear Friction Strength of Concrete)

  • 황용하;양근혁
    • 콘크리트학회논문집
    • /
    • 제28권4호
    • /
    • pp.419-426
    • /
    • 2016
  • 이 연구에서는 다양한 콘크리트를 갖는 전단계면에서의 전단마찰거동에 대한 횡보강근 및 압축응력의 영향을 평가하였다. 12개 직접전단실험체로부터 균열진전, 전단하중-상대 미끄러짐 관계, 균열발생시 전단응력, 최대전단내력 및 횡보강근의 전단저항력 등이 측정되었다. 실험결과 동일 전단하중에서 상대 미끄러짐 제어에 대한 횡보강근 배근형상 및 콘크리트 압축강도의 영향은 미미하였다. 작용 압축응력의 증가와 함께 콘크리트의 전단전달력을 증가하는 반면, 횡보강근의 전단전달력은 감소하였는데, 횡보강근의 전단저항은 배근형태에 의해 영향을 받지 않았다. AASHTO-LRFD, Mattock 및 Hwang and Yang의 모델은 콘크리트의 전단마찰내력을 과소평가하였다. 반면, Hwang and Yang의 모델은 실험결과와의 비교에 대한 평균과 표준편차 값이 각각 1.02과 0.23으로서 기존 모델에 비해 다양한 변수의 영향을 적절히 고려하면서 콘크리트의 전단마찰내력을 잘 예측하였다.

직교보를 고려한 RCS구조 보-기둥 접합부의 극한전단강도 (The Ultimate Shear Strength of RCS System Beam-Column Joints Considering the Transverse Beam)

  • 안재혁;박천석
    • 한국안전학회지
    • /
    • 제20권3호
    • /
    • pp.158-163
    • /
    • 2005
  • This paper is focusing on the model to predict the ultimate shear strength on joints of composite system (RCS) with reinforced concrete columns and steel beams considering the transverse beam. It reviews the ratio of experimental shear strength to design strength calculated by existing desist equations which are proposed by Kanno, Wight, Noguchi and the rising of strength by the transverse beams. When the shear strength of joints is estimated, it is necessary to do research work for the stress transfer mechanism considering two concrete strut of inner and outer panel by web of the transverse beam. In order to confirm it requires further experimental and analytical study.

소성 이론에 의한 강섬유 보강 초고성능콘크리트의 전단 마찰 강도식 제안 (Shear Friction Strength based on Limit Analysis for Ultra-High Performance Fiber Reinforced Concrete)

  • 이지형;홍성걸
    • 콘크리트학회논문집
    • /
    • 제27권3호
    • /
    • pp.299-309
    • /
    • 2015
  • 강섬유 보강 초고성능 콘크리트(UHPFRC)는 뛰어난 압축 및 인장강도를 가지고 있는 재료이다. 일반 콘크리트는 균열 발생 후 균열에 수직으로 보강된 철근의 구속력을 수직항력으로, 구속력에 의해 발생하는 골재 맞물림 등에 의한 균열면의 거칠기를 마찰 계수로 표현하여 전단 마찰 강도를 정의하고 있다. UHPFRC는 골재 맞물림 현상은 없으나 강섬유의 부착응력에 의한 균열 후 인장력이 상당히 큰 특징이 있으며, 이러한 특징은 전단 마찰 강도에 반영되어야 함이 타당하다. 본 연구에서는 전단면에 횡철근이 보강된 24개의 직접 전단실험체를 제작하여 푸시 오프 실험을 수행하였다. 실험결과는 소성 이론에 의해 분석되었으며 이로부터 전단 마찰 계수와 유효 계수를 도출하였다. 소성 이론에 의한 전단 마찰 강도식은 기존 실험결과 및 기존 전단 마찰 강도식과 비교하여 타당성을 검증하였으며, 최종적으로 UHPFRC의 균열 후 인장강도를 고려한 일체식 구조체의 전단 마찰 강도식을 제안하였다.

Axisymmetrical bending of single- and multi-span functionally graded hollow cylinders

  • Bian, Z.G.;Wang, Y.H.
    • Structural Engineering and Mechanics
    • /
    • 제45권3호
    • /
    • pp.355-371
    • /
    • 2013
  • Single- and multi-span orthotropic functionally graded hollow cylinders subjected to axisymmetrical bending are investigated on the basis of a unified shear deformable shell theory, in which the transverse displacement is expressed by means of a general shape function. To approach the through-thickness inhomogeneity of the hollow cylinder, a laminated model is employed. The shape function therefore shall be determined for each fictitious layer. To improve the computational efficiency, we resort to a transfer matrix method. Based on the principle of minimum potential energy, equilibrium equations are established, which are then solved analytically using the transfer matrix method for arbitrary boundary conditions. Numerical comparisons among a third-order shear deformable shell theory, an exact elastic theory and the present theory are provided for a simply supported hollow cylinder, from which the present theory turns out to be superior in stress estimation. Distributions of displacements and stresses in single- and three-span hollow cylinders with different boundary conditions are also illustrated in numerical examples.

Reinforcing effect of CFRP bar on concrete splitting behavior of headed stud shear connectors

  • Huawen Ye;Wenchao Wang;Ao Huang;Zhengyuan Wang
    • Steel and Composite Structures
    • /
    • 제48권2호
    • /
    • pp.131-143
    • /
    • 2023
  • The CFRP bar was used to achieve more ductile and durable headed-stud shear connectors in composite components. Three series of push-out tests were firstly conducted, including specimens reinforced with pure steel fibers, steel and CFRP bars. The distributed stress was measured by the commercial PPP-BOTDA (Pre-Pump-Pulse Brillouin optical time domain analysis) optical fiber sensor with high spatial resolution. A series of numerical analyses using non-linear FE models were also made to study the shear force transfer mechanism and crack response based on the test results. Test results show that the CFRP bar increases the shear strength and stiffness of the large diameter headed-stud shear connection, and it has equivalent reinforcing effects on the stud shear capacity as the commonly used steel bar. The embedded CFRP bar can also largely improve the shear force transfer mechanism and decrease the tensile stress in the transverse direction. The parametric study shows that low content steel fibers could delay the crack initiation of slab around the large diameter stud, and the CFRP bar with normal elastic modulus and the standard reinforcement ratio has good resistance to splitting crack growth in headed stud shear connectors.

비균열 인장재하 시험체의 압축장 이론에 기반한 전단전달강도 산정모델 (Estimation Model of Shear Transfer Strength for Uncracked Pull-Off Test Specimens based on Compression Field Theory)

  • 김민중;이기열
    • 대한토목학회논문집
    • /
    • 제41권2호
    • /
    • pp.101-111
    • /
    • 2021
  • 전단마찰 시험체는 재하형태에 따라 압축재하와 인장재하 시험으로 구분된다. 인장재하 시험의 경우에는 외력으로 작용하는 수직방향 인장력에 의하여 전단응력 및 수직방향 인장응력이 유발된다. 이 연구에서는 압축장 이론을 이용하여 인장재하 시험체의 전단전달강도를 평가하였으며, 2축-응력 상태의 콘크리트 최대 압축강도의 변화를 고려하기 위하여 수정압축장이론, 연화트러스모델의 구성방정식을 사용하였다. 타당성 검증을 위하여 과거 연구자들에 의해 수행된 직접전단강도 실험값들과 압축장 이론을 이용하여 구한 값들을 비교한 결과, 비균열 인장재하 시험체의 경우 예측값과 실측치가 대체적으로 잘 일치함을 확인하였다. 또한 콘크리트 스트럿의 유효압축강도를 고려한 전단강도 평가식을 제안하고, 기존 문헌에 수록된 실험결과와 비교함으로써 제안식의 적용 가능성을 검증하였다.

시공줄눈이 있는 콘크리트 경계면의 전단마찰 내력에 대한 보강철근의 영향 (Effect of Transverse Reinforcement on the Shear Friction Capacity of Concrete Interfaces with Construction Joint)

  • 황용하;양근혁
    • 콘크리트학회논문집
    • /
    • 제28권5호
    • /
    • pp.555-562
    • /
    • 2016
  • 이 연구의 목적은 부드러운 면의 시공줄눈을 가지는 콘크리트 경계면에서의 횡보강근의 전단전달력을 평가하는 것이다. 횡보강근의 배근은 전단마찰 면에 수직으로 배근한 그룹(V-type)과 $45^{\circ}$의 X형으로 교차배근 한 그룹(X-type)으로 나누었다. 전단마찰면에서 횡보강근비는 V형 철근배근의 경우 0.0045~0.0135로, X형 철근의 경우 0.0064 및 0.0045이다. 소성론의 상계치 이론(upper-bound theorem)을 기반으로 한 일체화된 콘크리트의 전단마찰모델을 수정하여, 부드러운 면의 시공줄눈을 갖는 콘크리트의 전단마찰내력을 평가하였다. 실험결과, 시공줄눈이 있는 두 부재사이의 전단마찰 내력에 대한 콘크리트 단위용적중량의 영향은 미미하였다. 시공줄눈에서 상대 미끄러짐 제어 및 전단마찰내력에 대해서는 X형 배근이 V형 배근에 비해 다소 유리하였다. 부드러운 면을 갖는 시공줄눈의 전단마찰내력에 대한 실험결과와 제안모델에 의한 예측값의 비들의 평균과 표준편차는 각각 1.07과 0.14로 나타났다.

Push-out tests on stud shear connectors with constrained structure of steel-concrete composite beams

  • Qi, Jingjing;Xie, Zuwei;Cao, Hua;Huang, Zhi;Lv, Weirong;Shi, Weihua
    • Structural Engineering and Mechanics
    • /
    • 제83권6호
    • /
    • pp.789-798
    • /
    • 2022
  • The stud shear connector is the main force transfer member in the steel-concrete composite member, and the mechanical behavior is very complicated in the concrete. The concrete around the stud is subjected to the pry-out local pressure concentration of the stud, which can easily produce splitting mirco-cracks. In order to solve the problem of pry-out local splitting of stud shear connector, a kind of stud shear connector with constraint measure is proposed in this paper. Through the push-out test, the interface shear behavior of the new stud shear connector between steel and concrete flange plate was studied, and the difference between the new stud shear connector and the traditional stud connector was compared. The results show that the stud shear connector with constraint measure can effectively avoid the adverse effect of local pressure splitting by relying on its own constraint measure. The shear stiffness of the interface between steel and concrete flange plates is greatly improved, which provides a theoretical basis for the design of strong connection coefficient of steel-concrete composite structures.

Interfacial properties of composite shotcrete containing sprayed waterproofing membrane

  • Park, Byungkwan;Lee, Chulho;Choi, Soon-Wook;Kang, Tae-Ho;Kim, Jintae;Choi, Myung-Sik;Jeon, Seokwon;Chang, Soo-Ho
    • Geomechanics and Engineering
    • /
    • 제16권4호
    • /
    • pp.385-397
    • /
    • 2018
  • This study evaluates the interfacial properties of composite specimens consisting of shotcrete and sprayed waterproofing membrane. Two different membrane prototypes were first produced and tested for their waterproofing ability. Then composite specimens were prepared and their interfacial properties assessed in direct shear and uniaxial compression tests. The direct shear test showed the peak shear strength and shear stiffness of the composites' interface decreased as the membrane layer became thicker. The shear stiffness, a key input parameter for numerical analysis, was estimated to be 0.32-1.74 GPa/m. Shear stress transfer at the interface between the shotcrete and membrane clearly emerged when measuring peak shear strengths (1-3 MPa) under given normal stress conditions of 0.3-1.5 MPa. The failure mechanism was predominantly shear failure at the interface in most composite specimens, and shear failure in the membranes. The uniaxial compression test yielded normal stiffness values for the composite specimens of 5-24 GPa/m. The composite specimens appeared to fail by the compressive force forming transverse tension cracks, mainly around the shotcrete surface perpendicular to the membrane layer. Even though the composite specimens had strength and stiffness values sufficient for shear stress transfer at the interfaces of the two shotcrete layers and the membrane, the sprayed waterproofing membrane should be as thin as possible whilst ensuring waterproofing so as to obtain higher strength and stiffness at the interface.