• 제목/요약/키워드: transparent envelope

검색결과 24건 처리시간 0.018초

투명단열재가 적용된 축열벽 시스템의 최적구성 선정에 관한 연구 (A study on the Optimum Design Configuration of Passive Solar TI-wall system)

  • 김병수;윤종호;윤용진;백남춘
    • KIEAE Journal
    • /
    • 제3권2호
    • /
    • pp.37-44
    • /
    • 2003
  • The aim of this study was to analyze the thermal performance through Test-Cell of TI-wall in domestic climate. This study was carried out as follows: 1) The TI-wall was studied for ability to reduce heat loss through the building envelope and analyzed to TIM properties. 2) Test models of TI-wall were designed through the investigation of previous paper and work, measured for winter and spring, and the thermal effects were analyzed. The type of the TIM used in test model is small-celled(diameter 4mm and thickness 50mm) capillary and cement brick(density $1500kg/m^3$) was used by thermal mass. 3) Test-cell of TI-wall was calibrated from measured data and the dynamic simulation program ESP-r 9.0. In these simulations, the measured climate conditions of TaeJon were used as outdoor conditions, and the simulation model of Test-cell was developed. 4) The sensitivity analysis is executed in various aspects with standard weather files and ESP-r 9.0, and then most suitable system of TI-wall are predicted. Finally, The suitable system of TI-wall was analysed according to sizes of air gap, kinds, thickness, and the surface absorption of therm wall. The result is following. In TI-wall, Concrete is better than cement brick, at that time the surface absorption is 95%, and the most efficient thickness is 250mm. As smaller of a air gap, as reducer of convection heat loss, it is efficient for heating energy. However, ensuring of a air gap at least more than 50mm is desirable for natural ventilation in Summer.

브랜치 도서관디자인의 공공성 표현에 관한 연구 - 미국 마리코파 카운티를 중심으로 - (A Study on the Expression of the Publicness on Public Branch Library Design - Focus on the Maricopa County, USA -)

  • 손광호
    • 한국실내디자인학회논문집
    • /
    • 제21권6호
    • /
    • pp.271-279
    • /
    • 2012
  • Among the community-based cultural facilities, public libraries are places for social and educational purpose that improve the education of the resident, the expansion of the basic cultural education, communication between the members of society, and the accumulations and preservations of the culture. Public libraries should be a local cultural facility that expresses the value of a community. This study aims to analyze the design expression of publicness in a public branch library as a community-based cultural space through the study of branch library in the U.S. This study focused on the most future-oriented and innovative Ten New Landmark Libraries in the United States selected by Library Journal magazine in 2011. Among the selected libraries, three branch libraries which belongs Arizona Maricopa County were included in the study. The results of this study are as follows. First, the sites of the branch libraries vary geographically, but the libraries increase accessibility are caused by unique appearances and design concept of intellectual interest. Second, the floor plan shows the separation of meeting rooms and faculty space from the public space and has visual and spatial open space by high ceiling of the reading room. Third, multi-functional public space for residents are meeting rooms, the external patios for reading, galleries, cafes, libraries-shops which provides a variety of cultural programs, activities, and the opportunity to socialize neighbors. Fourth, branch Libraries have unique designs that harmonizes with nearby places to reflect locality, giving the locals a sense of pride in their community. Fifth, concrete brick and metal panel were used as finishing material for the practicality of maintenance. In particular, transparent glass envelope allows the locals to stay for long time due to openness and brightness of space.

  • PDF

양면형 BIPV 시스템의 설치환경에 따른 발전특성 분석 (Analysis of Generation Characteristics of a Bifacial BIPV System According to Installation Methods)

  • 강준구;김진희;김준태
    • Current Photovoltaic Research
    • /
    • 제3권4호
    • /
    • pp.121-125
    • /
    • 2015
  • BIPV system is one of the best ways to harness PV module. The BIPV system not only produces electricity, but also acts as a building envelope. Thus, it has the strong point of increasing the economical efficiency by applying the PV modules to the buildings. Bifacial solar cells can convert solar energy to electrical energy from both sides of the module. In addition, it is designed as 3 busbar layout which is the same with ordinary mono-facial soalr cells. Therefore, many of the module manufacturers can easily produce the bifacial solar cells without changing their manufacturing equipment. Moreover, bifacial BIPV system has much potential in building application by utilizing glass to glass structure. However, the performance of bifacial solar cells depends on a variety of factors, ranging from the back surface to surrounding conditions. Therefore, in order to apply bifacial solar cells to buildings, an analysis of bifacial PV module performance should be carried out that includes a consideration of various design elements, and reflects a wide range of installation conditions. As a result it found that the white insulation reflector type can improve the performance of the bifacial BIPV system by 16%, compared to the black insulation reflector type. The performance of the bifacial BIPV was also shown to be influenced by inclination angle, due to changes in both the amount of radiation captured on the front face and the radiation transmitted to the rear face through the transparent space. In this study is limited design condition and installation condition. Accordingly follow-up researches in this part need to be conducted.

Structural glass panels: An integrated system

  • Bidini, G.;Barelli, L.;Buratti, C.;Castori, G.;Belloni, E.;Merli, F.;Speranzini, E.
    • Smart Structures and Systems
    • /
    • 제30권3호
    • /
    • pp.327-332
    • /
    • 2022
  • In building envelope, transparent components play an important role. The structural glazing systems are the weak element of the casing in terms of mechanical resistance, thermal and acoustic insulation. In the present work, new structural glass panels with granular aerogel in interspace were investigated from different points of view. In particular, the mechanical characterization was carried out in order to assess the resistance to bending of the single glazing pane. To this end, a special instrument system was built to define an alternative configuration of the coaxial double ring test, able to predict the fracture strength of glass large samples (400 × 400 mm) without overpressure. The thermal and lighting performance of an innovative double-glazing façade with granular aerogel was evaluated. An experimental campaign at pilot scale was developed: it is composed of two boxes of about 1.60 × 2 m2 and 2 m high together with an external weather station. The rooms, identical in terms of size, construction materials, and orientation, are equipped with a two-wing window in the south wall surface: the first one has a standard glazing solution (double glazing with air in interspace), the second room is equipped with the innovative double-glazing system with aerogel. The indoor mean air temperature and the surface temperature of the glass panes were monitored together with the illuminance data for the lighting characterization. Finally, a brief energy characterization of the performance of the material was carried out by means of dynamic simulation models when the proposed solution is applied to real case studies.