• 제목/요약/키워드: transmitted intensity

검색결과 143건 처리시간 0.029초

화상분석 시스템을 이용한 지필도 평가 (Characterization of Sheet Formation by Image Analysis)

  • 원종명
    • 펄프종이기술
    • /
    • 제31권4호
    • /
    • pp.30-40
    • /
    • 1999
  • The possibility of the characterization of sheet formation by image analysis with transmitted light was evaluated. Specific perimenter, average perimeter and variation could not be used to predict the sheet formation because there were no corrleation. Although image analysis method still have a lot of problems , it was found that the contrast intensity obtained by image analysis with transmitted light can be used to predict the sheet formation. In the case of highly filled sheet, the intensity of transmitted light was too low to characterize the sheet formation . However, it was possible to characterize the formation of unfilled heavy weight paper($\leq$200g/㎡).

  • PDF

Measurement of red blood cell aggregation by analysis of light transmission in a pressure-driven slit flow system

  • Shin, S.;Park, M.S.;Jang, J.H.;Ky, Y.H.;Suh, J.S.
    • Korea-Australia Rheology Journal
    • /
    • 제16권3호
    • /
    • pp.129-134
    • /
    • 2004
  • The aggregation characteristics of red blood cells (RBCs) were measured using a newly developed light-transmission slit rheometer. Conventional methods of RBC disaggregation such as the rotational Couette system were replaced with a pressure-driven slit flow system with a vibrational mechanism. Using a vibration generator, one can disaggregate the RBC aggregates stored in the slit. While shear stress decreases exponentially, instantaneous pressure and the transmitted light intensity were measured over time. Applying an abrupt shearing flow after disaggregation caused a rapid elongation of the RBCs followed by loss of elongation with the decreasing shear stress. While the shear stress is further decreasing, the RBCs start to re-aggregate and the corresponding transmitted intensity increases with time, from which the aggregation indices can be obtained using a curve-fitting program.

Development of Light Transmission Fluctuation for Particle Measurement in Solid-Gas Two Phase Flows

  • YANG, Bin;WANG, Zhan-ping;HE, Yuan;CAI, Xiao-Shu
    • 한국입자에어로졸학회지
    • /
    • 제12권1호
    • /
    • pp.21-26
    • /
    • 2016
  • In order to realize In-line and convenient measurement for solid-gas two phase flows, Light Transmission Fluctuation (LTF) based on the random variation of transmitted light intensity, light scattering theory and cross-correlation method was presented for online measurement of particle size, concentration and velocity. The statistical relationship among transmitted light intensity, particle size and particle number in measurement zone was described by Beer-Lambert Law. Accordingly, the particle size and concentration were determined from the fluctuation signal of transmitted light intensity. Simultaneously, the particle velocity was calculated by cross-correlation analysis of two neighboring light beams. By considering the influence of concentration variation in industrial applications, the improved algorithm based on spectral analysis of transmitted light intensity was proposed to improve measurement accuracy and stability. Therefore, the online measurement system based on LTF was developed and applied to measure pulverized coal in power station and raw material in cement plant. The particle size, concentration and velocity of powder were monitored in real-time. It can provide important references for optimal control, energy saving and emission reduction of energy-intensive industries.

표면 인텐시티법을 이용한 건물부위의 음향투과손실 측정 (Measurement of Transmission Loss Using Surface Intensity Method in Building Elements)

  • 김흥식;손장열;오재응
    • 한국음향학회지
    • /
    • 제6권3호
    • /
    • pp.17-22
    • /
    • 1987
  • 새로운 차음성능 측정방법인 표면인텐시티법을 이용하여 실제 건축물의 현장에서 각부위별 차음성능 평가하고. 이를 종래의 음압측정방법과 은향인텐시티법 및 이론계산에 의한 결과 치 와 비교 . 검토하였다. 표면인텐시티법에 의한 건물부위의 차음성능 측정결과치는 음향인 텐시티법 및 이론계산에 의한 결과치와 잘 일치하였으며, 표면 인텐시티법은 음향인텐시티 법과 더불어 종래의 음압측정방법에 비해 측정시 주위 암소음 및 flanking transmission의 영향을 적게 받는 것으로 나타났다.

  • PDF

광시스템에서 maximum 신호 Sensing을 위한 Algorithm 설계 (Design of Algorithm for maximum Signal Sensing by Optical System)

  • 최도순
    • 한국정보전자통신기술학회논문지
    • /
    • 제3권4호
    • /
    • pp.70-75
    • /
    • 2010
  • 이 논문은 광케이블인 optical fiber를 통해 의료용 signal을 전송 할 때 porarization obtain fiber 에서 mono mode fiber로 교체되는 지점에 integrated optic인 wave conductor를 사용하여, optical signal intensity의 maximum를 sensing 하기 위한 Algorithm Brent을 설계하고 이를 검토하였다.

  • PDF

광 투사법을 이용한 슬릿 점도계에서의 적혈구 응집성 및 점도 측정에 관한 연구 (Simultaneous measurements of red blood cell aggregation and blood viscosity in a slit rheometry with light transmission analysis)

  • 박명수;구윤희;신세현;서장수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1678-1681
    • /
    • 2004
  • The light-transmission technique has been applied to a slit rheometer for measuring red blood cell aggregation as well as blood viscosity over a range of shear rates. For measurement of blood viscosity and aggregation, instantaneous pressure and transmit-light intensity are measured with time. Using a precision pressure measurement, one can determine the shear stress and shear rate. In addition, a transmitted light through a blood sample indicates degree of RBC aggregation. With abruptly flowing with high shear rate, RBCs rapidly disaggregate and the intensity of the transmitted light becomes low. When continuously flowing with decreasing shear rate, RBCs tend to re-aggregate and the corresponding transmit-intensity gradually increases with time. The light intensity as a degree of RBC aggregation is plotted against shear rate and compared with blood viscosity. The advantages of this design are dual measurement at a time, simplicity, i.e., ease of operation and no moving parts, low cost, short operating time, and the disposable kit which is contacted with blood sample.

  • PDF

Ir-192 $\gamma$선(線)의 금속(金屬)에 대(對)한 산란분포(散亂分布)에 관(關)한 연구(硏究) (A Study on Scattering Distribution in Metal of Ir-192 Gamma-Ray)

  • 주광태
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제4권1호
    • /
    • pp.63-71
    • /
    • 1981
  • The metal-plates(Aluminium. Copper, Lead) of change the variation thickness have been penetrated by the collimated beam($450mm{\times}4mm{\phi}$) of Gamma-ray from $^{192}Ir$. Then, the scattered $\gamma$-ray dose in variable angle and the directly transmitted $\gamma$-ray dose were measured using the electrometer of ionization chamber. The results were summarized as follows: 1. Obtained the mass attenuation coefficients of $Al;0.0937cm^2g^{-1},\;Cu;0.0937cm^2g^{-1},\;pb;0.244cm^2g^{-1}$. 2. Total intensity of front scattered $\gamma$-ray follow the order of Al>Cu>pb. 3. The scattered $\gamma$-ray intensity with the lager angle of scattering was saturated after increase rapidly, and the scattering angle of the more larger was decreased. 4. The scattered $\gamma$-ray intensity through plates of aluminium or copper was saturated after increase with thicker scatterer, and the intensity was decreased at the more thicker. But the variation of scattered $\gamma$-ray dose in the lead plate made the fewest than Al and Cu. 5. The ratio of the scattered $\gamma$-ray dose and the directly transmitted $\gamma$-ray dose was saturated after increase with the thicker scatterer, and the scatterer of the more thicker was decreased. Degree of total intensity in these ratios was followed the order of Cu>Al>Pb.

  • PDF

Ground-to-air transmitted sound from shallow earthquakes

  • 이병호
    • 한국음향학회지
    • /
    • 제3권1호
    • /
    • pp.3-8
    • /
    • 1984
  • By one dimensional acoustic transmission from ground to air, the author has derived the level of sound caused by earthquakes. He has also tried to assign proper values of ground acceleration to the modified mercalli intensity scale and thence earthquake sound level to the intensity scale has been deduced as L\sub M/ = 79.6+6.0M, dB, where M is the earthquake magnitude in the modified Mercalli intensity scale.

  • PDF

Vibration and Noise Control of Structural Systems Using Squeeze Mode ER Mounts

  • Jeong, Weui-Bong;Yoo, Wan-Suk;Jung, Woo-Jin
    • Journal of Mechanical Science and Technology
    • /
    • 제17권12호
    • /
    • pp.1949-1960
    • /
    • 2003
  • This paper presents vibration and noise control of flexible structures using squeeze mode electro-rheological mounts. After verifying that the damping force of the ER mount can be controlled by the intensity of the electric fild, two different types of ER squeeze mounts have been devised. Firstly, a small size ER mount to support 3 kg is manufactured and applied to the frame structure to control the vibration. An optimal controller which consists of the velocity and the transmitted force feedback signals is designed and implemented to attenuate both the vibration and the transmitted forces. Secondly, a large size of ER mount to support 200 kg is devised and applied to the shell structure to reduce the radiated noise. Dynamic modeling and controller design are undertaken in order to evaluate noise control performance as well as isolation performance of the transmitted force. The radiated noise from the cylindrical shell is calculated by SYSNOISE using forces which are transmitted to the cylindrical shell through two-stage mounting system.

윤활유 오염에 따른 광투과율 변화에 관한 실험적 연구 (An Experimental Study on the Light Transmission Characteristics with Oil Contamination)

  • 조성용;장철주;공호성;윤의성;한흥구
    • Tribology and Lubricants
    • /
    • 제17권6호
    • /
    • pp.482-489
    • /
    • 2001
  • Changes in light transmission characteristics caused by various types of oil contaminations were experimentally measured with a built-in type wear monitoring device. Three kinds of iron powders of different size distribution, carbon duct, two kinds of solutions and grease were used for the test contaminants in this work. Light intensity of the transmitted light was measured with the contamination level. Results showed that the transmitted light intensity decreased linearly with the contamination concentration in the oil and the slope was affected by the size distribution. Light attenuation was also caused greatly by carbon dust, water contamination and poly-meric fibers in terms of the light absorption. As a result, it was proved that the optical measurement device could be applicable effectively for detecting any significant change in lubricating oils.