• Title/Summary/Keyword: transmission potential

Search Result 809, Processing Time 0.032 seconds

Examination with Transmission Line Distance Relay Setting Rule Considering Error (오차를 고려한 송전선 보호 거리계전 정정룰에 대한 고찰)

  • Cho, Seong-Jin;Choi, Myeong-Song;Hyun, Seung-Ho;Kim, Joung-Wook;Lee, Joo-Wang;Cho, Bum-Sub;Yoo, Young-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.12-15
    • /
    • 2002
  • Korea Power System Protection Setting Rule was used from the rectify 1990's. Thereafter transmission voltage is raised the voltage into 765kV, and introduction to new technology of Power System, and was many of variation but, it is using. The present is using Digital type distance relay for 765kV transmission line protection. If impedance value of transmission line were to value lower than setting, this would be operating and relay setting rule is for 85% into Zone 1 self section, and Zone 2 is a 125%, Zone 3 is a 225%. Which's $15{\sim}25%$ include current transformer error 5%, potential transformer 5%, relay calculation error 5% and margin factor from the field experience. This paper is discussed transmission protective relay and relay setting rule of high voltage power system and we verify the correctness relay setting rule with distance relay using Matlab simulation.

  • PDF

Radiation and Underwater Transmission Characteristics of a High-luminance Light-emitting Diode as the Light Source for Fishing Lamps (집어등 광원으로서 고휘도 발광 다이오우드의 방사 및 수중투과 특성)

  • Choi, Sok-Jin
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.39 no.6
    • /
    • pp.480-486
    • /
    • 2006
  • The radiation characteristics of a high-luminance light-emitting diode (LED) light source were studied to evaluate its potential as an energy-saving light source for fishing lamps. The angle of the LED light source with 50% illuminance was $8-15^{\circ}$, and it had strong directional characteristics. The wavelengths at which the radiance and irradiance were maxima were 709, 613, 473, 501, 525, and 465 nm for red, orange, blue, peacock blue, green, and white light, respectively. The underwater transmission characteristics of the LED light source were superior in the order blue, white, peacock blue, and green in optical water type I: blue, peacock blue, white, and green in optical water type II; and blue, peacock blue, green, and white in optical water type III. Setting the underwater transmission characteristics of the LED light source in optical water type I at 100%, the transmission of water types II and III decreased to 67 and 17%, respectively. Based on the underwater transmission characteristics calculated in optical water types I-III, the blue and peacock blue LED light sources can be used as an energy-saving light source for fishing lamps.

Bio-Medical Data Transmission System using Multi-level Visible Light based on Resistor Ladder Circuit (저항 사다리 회로 기반의 다중레벨 가시광을 이용하는 의료 데이터 전송 시스템)

  • An, Jinyoung;Chung, Wan-Young
    • Journal of Sensor Science and Technology
    • /
    • v.25 no.2
    • /
    • pp.131-137
    • /
    • 2016
  • In this study, a multilevel visible light communication (VLC) system based on resistor ladder circuit is designed to transmit medical data. VLC technology is being considered as an alternative wireless communication due to various advantages such as ubiquity, license free operation, low energy consumption, and no radio frequency (RF) radiation characteristics. With VLC even in places where traditional RF communication (e.g., Wi-Fi) is forbidden, significant bio-medical signal including the electrocardiography (ECG) and photoplethysmography (PPG) data can be transmitted. More lives could be saved anywhere by this potential advantage of VLC with a fast emergency response time. A multilevel transmission scheme is adopted to improve the data capacity with keeping simplicity, where data transmission rate can increase by log2m times (m is the number of voltage levels) than that of conventional VLC transmission based on on/off keying. In order to generate multi-amplitudes, resistor ladder circuit, which is a basic principle of digital to analog convertor, is employed, and information is transferred through LED (Light-Emitting Diode) with different voltage level. In the receiver side, multilevel signal is detected by optical receiver including a photo diode. Then, the collected data are analyzed to serve the necessary medical care to the concerned patient.

Application of Particle Swarm Optimization to the Reliability Centered Maintenance Method for Transmission Systems

  • Heo, Jae-Haeng;Lyu, Jae-Kun;Kim, Mun-Kyeom;Park, Jong-Keun
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.6
    • /
    • pp.814-823
    • /
    • 2012
  • Electric power transmission utilities make an effort to maximize profit by reducing their electricity supply and operation costs while maintaining their reliability. The development of maintenance strategies for aged components is one of the more effective ways to achieve this goal. The reliability centered approach is a key method in providing optimal maintenance strategies. It considers the tradeoffs between the upfront maintenance costs and the potential costs incurred by reliability losses. This paper discusses the application of the Particle Swarm Optimization (PSO) technique used to find the optimal maintenance strategy for a transmission component in order to achieve the minimum total expected cost composed of Generation Cost (GC), Maintenance Cost (MC), Repair Cost (RC) and Outage Cost (OC). Three components of a transmission system are considered: overhead lines, underground cables and insulators are considered. In regards to aged and aging component, a component state model that uses a modified Markov chain is proposed. A simulation has been performed on an IEEE 9-bus system. The results from this simulation are quite encouraging, and then the proposed approach will be useful in practical maintenance scheduling.

Short-term activation of synaptic transmission by acute KCl application significantly reduces somatic A-type K+ current

  • Song, Jung-Yop;Kim, Hye-Ji;Jung, Sung-Cherl;Kang, Moon-Seok
    • Journal of Medicine and Life Science
    • /
    • v.15 no.2
    • /
    • pp.62-66
    • /
    • 2018
  • A-type $K^+$ ($I_A$) channels are transiently activated in the suprathreshold membrane potential and then rapidly inactivated. These channels play roles to control the neuronal excitability in pyramidal neurons in hippocampi. We here electrophysiologically tested if regulatory functions of $I_A$ channels might be targeted by acute activation of glutamatergic synaptic transmission in cultured hippocampal neurons(DIV 6~8). The application of high KCl in recording solutions(10 mM, 2 min) to increase presynaptic glutamate release, significantly reduced the peak of somatic $I_A$ without changes of gating kinetics. This indicates that neuronal excitation induced by the enhancement of synaptic transmission may process with distinctive signaling cascades to affect voltage-dependent ion channels in hippocampal neurons. Therefore, it is possible that short-lasting enhancement of synaptic transmission is functionally restricted in local synapses without effects on intracellular signaling cascades affecting a whole neuron, efficiently and rapidly enhancing synaptic functions in hippocampal network.

Dynamic Thermal Rating of Overhead Transmission Lines Based on GRAPES Numerical Weather Forecast

  • Yan, Hongbo;Wang, Yanling;Zhou, Xiaofeng;Liang, Likai;Yin, Zhijun;Wang, Wei
    • Journal of Information Processing Systems
    • /
    • v.15 no.4
    • /
    • pp.724-736
    • /
    • 2019
  • Dynamic thermal rating technology can effectively improve the thermal load capacity of transmission lines. However, its availability is limited by the quantity and high cost of the hardware facilities. This paper proposes a new dynamic thermal rating technology based on global/regional assimilation and prediction system (GRAPES) and geographic information system (GIS). The paper will also explore the method of obtaining any point meteorological data along the transmission line by using GRAPES and GIS, and provide the strategy of extracting and decoding meteorological data. In this paper, the accuracy of numerical weather prediction was verified from the perspective of time and space. Also, the 750-kV transmission line in Shaanxi Province is considered as an example to analyze. The results of the study indicate that dynamic thermal rating based on GRAPES and GIS can fully excavate the line power potential without additional cost on hardware, which saves a lot of investment.

Autonomous Transmission Power Adjustment Strategy for Femtocell Base Station

  • Alotaibi, Sultan
    • International Journal of Computer Science & Network Security
    • /
    • v.22 no.4
    • /
    • pp.367-373
    • /
    • 2022
  • Femtocells have recently been recognized for their potential to boost network capacity, improve end-user QoS and throughput, and do so at a cheap cost and with ease of implementation. The use of femtocells in indoor environments, such as residential buildings with neighboring homes, is becoming more popular. Femtocells are subject to interference from other femtocells, and the unwanted effects of interference are amplified when femtocells are deployed in close proximity to one another. As a consequence, the network's overall performance is degraded to a significant degree. One of the strategies that is thought to be effective in reducing the impact of interference is altering the transmission power of the femtocells. In this paper, a dynamic downlink transmission power of femtocells is suggested. In accordance with the observed cost function unit, each femtocell automatically changes its transmission power. If a femtocell causes too much interference for its neighbors, its transmission power level will be limited by that interference's rate. A simulation experiment is conducted to validate the effectiveness of the suggested system when compared with other schemes. When compared to previous schemes, which are addressed in this study, the numerical results show that the proposed strategy could provide more capacity while also ideally mitigating the influence of interference among co-channel deployed femtocells.

A Study on Separation Distance Calculation Model for Limitation of Earth Potential Rise Nearby Tower Footings (송전철탑 부근의 대지전위 억제를 위한 이격거리 산정모델 연구)

  • Choi, Jong-Kee;Cho, Hwan-Gu;Kim, Tai-Young;Lee, Dong-Il
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.2
    • /
    • pp.179-183
    • /
    • 2008
  • In case of a line-to-ground fault at transmission lines, a portion of fault current will flow into the earth through the footings of the faulted tower causing electrical potential rise nearby the faulted tower footings. In this situation, any buried pipelines or structures nearby the faulted tower can be exposed to the electrical stress by earth potential rise. Although many research works has been conducted on this phenomena, there has been no clear answer of the required separation distance between tower footings and neary buried pipeline because of its dependancy on the soil electrical charactersics of the concerned area and the faulted system. In this paper, an analytical formula to calculate the requried sepeartion distance from the faulted tower has been derived.

Determination of stress intensity factor by means of ACPD technique for ferromagnetic materials (교류전위차법에 의한 강자성체의 응력확대계수 결정)

  • Lee, Jeong-Hee
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.9
    • /
    • pp.1392-1399
    • /
    • 1997
  • In order to determine the Mode I stress intensity factor ($K_1$) experimentally by means of the alternating current potential drop(ACPD) technique, the change in potential drop due to load for a ferromagnetic material containing a two-dimensional surface crack was examined. The cause of the change in potential drop and the effect of the magnetic flux on the change in potential drop were clarified by using the measuring systems with and without removing the magnetic flux from the circumference of the specimen. To remove the magnetic flux, a new measuring system was made by utilizing the characteristic of coaxial transmission line. The change in potential drop in the case without magnetic flux in the air was caused by the change in electromagnetic properties near the crack tip due to magnetization. The relationship between the change in potential drop and the change in $K_I$ was linealized by demagnetization and was found to be independent of the crack length.

Transmission Line Analysis of Accumulation Layer in IEGT

  • Moon, Jin-Woo;Chung, Sang-Koo
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.6
    • /
    • pp.824-828
    • /
    • 2011
  • Transmission line analysis of the surface a cumulation layer in injection-enhanced gate transistor (IEGT) is presented for the first time, based on per-unit-length resistance and conductance of the surface layer beneath the gate of IEGT. Lateral electric field on the accumulation layer surface, as well as the electron current injected into the accumulation layer, is governed by the well-known wave equation, and decreases as an exponential function of the lateral distance from the cathode. Unit-length resistance and conductance of the layer are expressed in terms of the device parameters and the applied gate voltage. Results obtained from the experiments are consistent with the numerical simulations.