• Title/Summary/Keyword: transmission line tower

Search Result 134, Processing Time 0.029 seconds

Seismic response control of transmission tower-line system using SMA-based TMD

  • Tian, Li;Zhou, Mengyao;Qiu, Canxing;Pan, Haiyang;Rong, Kunjie
    • Structural Engineering and Mechanics
    • /
    • v.74 no.1
    • /
    • pp.129-143
    • /
    • 2020
  • This study proposes a new shape memory alloy-tuned mass damper (SMA-TMD) and investigates the effectiveness of this damper in reducing and controlling the vibrations of a transmission tower-line system under various seismic excitations. Based on a practical transmission line system and considering the geometric nonlinearity of this system, the finite element (FE) software ANSYS is used to create an FE model of the transmission tower-line system and simulate the proposed SMA-TMD. Additionally, the parameters of the SMA springs are optimized. The effectiveness of a conventional TMD and the proposed SMA-TMD in reducing and controlling the vibrations of the transmission tower-line system under seismic excitations is investigated. Moreover, the effects of the ground motion intensity and frequency ratio on the reduction ratio (η) of the SMA-TMD are studied. The vibration reduction effect of the SMA-TMD under various seismic excitations is superior to that of the conventional TMD. Changes in the ground motion intensity and frequency ratio have a significant impact on the η of the SMA-TMD. As the ground motion intensity and frequency ratio increase, the η values of the SMA-TMD first increase and then decrease. Studying the vibration reduction effects of the SMA-TMD can provide a reference for the practical engineering application of this damper.

Development and Application of Overhead Transmission Line Design Program Using High Spatial Resolution Satellite Imagery (고해상도 위성영상을 이용한 송전선로 경과지 설계 프로그램 개발 및 활용)

  • Lee, Hee-Seon;Park, Byoung-Won
    • Proceedings of the KIEE Conference
    • /
    • 2005.11b
    • /
    • pp.27-29
    • /
    • 2005
  • Overhead transmission line design supporting program using high spatial resolution satellite imagery has been developed recently by Korea Power Engineering Company, The developed program, ITSS(Interactive Tower Spotting System) is purposed to improve the application of satellite imagery with the route selection of overhead transmission line. It is composed of spotting the tower position and designing the tower type and height with DEM(Digital Elevation Model) overlaid with satellite Imagery. To review and confirm the function and work efficiency, ITSS was applied to the pilot project of overhead transmission line design.

  • PDF

A Study on the Voltage Upgrading of Transmission Lines using Polymer Insulation Arm (폴리머 절연암을 이용한 송전선로 전압 승압에 관한 연구)

  • Lee, Won-Kyo;Lee, Jung-Won;Kang, Yeon-Woog;Lee, Dong-Il
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.10
    • /
    • pp.870-878
    • /
    • 2009
  • The large increase in the use of electricity has resulted in an ever-growing electric power demand. It has created the need for the construction of power transmission facility located close to the load centers and it also has to require wide right-of-way and large lots, that are not always available, for especially the installation of the towers. The difficulties in acquiring right-of-way have put pressure on energy companies to either upgrade a line on an existing right-of-way to higher voltage or build a new line on a narrow right-of-way. This paper presents the design of a compact tower with polymer Insulation arm, in order to reduce the separation between phases. the compact tower can be built on a narrow right-of-way. the compact tower can be designed based on 345 kV Tower regarding electrical clearances and right of way, therefore the conventional 154 kV Tower can be upgrading transmission line voltages have moved to 345 kV levels.

Capacity assessment of existing corroded overhead power line structures subjected to synoptic winds

  • Niu, Huawei;Li, Xuan;Zhang, Wei
    • Wind and Structures
    • /
    • v.27 no.5
    • /
    • pp.325-336
    • /
    • 2018
  • The physical infrastructure of the power systems, including the high-voltage transmission towers and lines as well as the poles and wires for power distribution at a lower voltage level, is critical for the resilience of the community since the failures or nonfunctioning of these structures could introduce large area power outages under the extreme weather events. In the current engineering practices, single circuit lattice steel towers linked by transmission lines are widely used to form power transmission systems. After years of service and continues interactions with natural and built environment, progressive damages accumulate at various structural details and could gradually change the structural performance. This study is to evaluate the typical existing transmission tower-line system subjected to synoptic winds (atmospheric boundary layer winds). Effects from the possible corrosion penetration on the structural members of the transmission towers and the aerodynamic damping force on the conductors are evaluated. However, corrosion in connections is not included. Meanwhile, corrosion on the structural members is assumed to be evenly distributed. Wind loads are calculated based on the codes used for synoptic winds and the wind tunnel experiments were carried out to obtain the drag coefficients for different panels of the transmission towers as well as for the transmission lines. Sensitivity analysis is carried out based upon the incremental dynamic analysis (IDA) to evaluate the structural capacity of the transmission tower-line system for different corrosion and loading conditions. Meanwhile, extreme value analysis is also performed to further estimate the short-term extreme response of the transmission tower-line system.

Analysis of system power flow margin on replacement of transmission line to DC line (송전선로 DC화에 따른 융통조류 마진 분석)

  • Hwang, Sungchul;Lee, Jaehyeong;Hwang, Pyungik;Yoon, Minhan;Jang, Gilsoo
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.420-421
    • /
    • 2015
  • Recently construction of new transmission line is getting harder because of social hostility to transmission tower. Howevere, load is converged in metropolitan area and power plants near this area are old and life of generator will end soon. Therefore, power to supply load in this area should be transmitted from east coast area and southern area. For these reasons, securement of transmission capacity without new transmission line construction is important. In this paper, effect of one circuit AC line change to DC transmission at the same transmission tower on the system available transfer capacity is analyzed.

  • PDF

Stability behavior of the transmission line system under incremental dynamic wind load

  • Sarmasti, Hadi;Abedi, Karim;Chenaghlou, Mohammad Reza
    • Wind and Structures
    • /
    • v.31 no.6
    • /
    • pp.509-522
    • /
    • 2020
  • Wind load is the principal cause for a large number of the collapse of transmission lines around the world. The transmission line is traditionally designed for wind load according to a linear equivalent method, in which dynamic effects of wind are not appropriately included. Therefore, in the present study, incremental dynamic analysis is utilized to investigate the stability behavior of a 400 kV transmission line under wind load. In that case, the effects of vibration of cables and aerodynamic damping of cables were considered on the stability behavior of the transmission line. Superposition of the harmonic waves method was used to calculate the wind load. The corresponding wind speed to the beginning of the transmission line collapse was determined by incremental dynamic analysis. Also, the effect of the yawed wind was studied to determine the critical attack angle by the incremental dynamic method. The results show the collapse mechanisms of the transmission line and the maximum supportable wind speed, which is predicted 6m/s less than the design wind speed of the studied transmission line. Based on the numerical modeling results, a retrofitting method has been proposed to prevent failure of the tower members under design wind speed.

Behavior of self supported transmission line towers under stationary downburst loading

  • Darwish, Mohamed M.;El Damatty, Ashraf A.
    • Wind and Structures
    • /
    • v.14 no.5
    • /
    • pp.481-498
    • /
    • 2011
  • During the past decade, many electrical transmission tower structures have failed during downburst events. This study is a part of a research program aimed to understand the behaviour of transmission lines under such localized wind events. The present study focuses on assessing the behaviour of self supported transmission line towers under downburst loading. A parametric study is performed to determine the critical downburst configurations causing maximum axial forces for various members of a tower. The sensitivity of the internal forces developing in the tower's members to changes in the downburst size and location was studied. The structural behaviour associated with the critical downburst configurations is described and compared to the behaviour under 'normal' wind loads.

Investigation on the failure type of tower segments under equivalent static wind loads

  • Li, Yue;Xie, Qiang;Yang, Zheng
    • Wind and Structures
    • /
    • v.34 no.2
    • /
    • pp.161-171
    • /
    • 2022
  • This paper presents a failure type assessment curve method to judge the failure type of transmission tower segments. This novel method considers the equivalent static wind load characteristics and the transmission tower members' load-bearing capacities based on numerical simulations. This method can help judge the failure types according to the relative positions between the actual state points and the assessment curves of transmission tower segments. If the extended line of the actual state point intersects with the horizontal part's assessment curve, the segment would lose load-bearing capacity due to the diagonal members' failure. Another scenario occurs when the intersection point is in the oblique part, indicating that the broken main members have caused the tower segment to fail. The proposed method is verified by practical engineering case studies and static tests on the scaled tower segments.

A Safety Analysis of Electric Detonator for Stray Currents by Domestic Transmission Network System (국내 송전계통별 미주전류에 의한 전기뇌관의 안전성 분석)

  • Park Hyun-Sik;Kim Young-Seok;Kang Choo-Won
    • Tunnel and Underground Space
    • /
    • v.15 no.4 s.57
    • /
    • pp.296-304
    • /
    • 2005
  • This study is to observe stray currents generated around the steel tower by domestic transmission network system and analysis stability of electric detonator. It is measured the stay current of each ten place at steel tower of 765 kV, 345 tV, 154 tV transmission line among domestic transmission network system. Stay currents measured a total of 40m at intervals of 4m toward a line direction and a line vertical direction centering around steel tower. Temperature of the surface, EC, water content also are measured. Although stay currents show the highest values, that is 12 percent of at 4m and less than 1 percent of 40m with Institute of Makers of Explosives(IME) regulations. It is shown correlation between stay currents and water content$\cdot$EC$\cdot$temperature of the surface. Stay currents measured at line direction and line vertical direction were little different and the shape of diminution was also shown a similar aspect.

Geospatial analysis of wind velocity to determine wind loading on transmission tower

  • Hamzah, Nur H.;Usman, Fathoni
    • Wind and Structures
    • /
    • v.28 no.6
    • /
    • pp.381-388
    • /
    • 2019
  • This paper described the application of Geospatial Analysis in determining mean wind speed, $V_h$ for wind load calculation imposed to electrical transmission tower structural design. The basic wind speed data on available station obtained from Malaysian Meteorology Department is adjusted by considering terrain and ground roughness factor. The correlation between basic wind speed, terrain factor and ground roughness stated in EN-50341-1 is used to obtain the $V_h$ for overhead transmission line elements 50 m above ground. Terrain factor, $k_r$ and ground roughness, $z_0$ in this study are presented by land use types of study area. Wind load is then calculated by using equation stated in design code EN-50341-1 by using the adjusted mean wind speed. Scatter plots of $V_h$ for different $k_r$and $z_0$ are presented in this paper to see the effect of these parameters to the value of $V_h$. Geospatial analysis is used to represent the model of $V_h$. This model can be used to determine possible area that will subject to wind load which severe to the stability of transmission tower and transmission line.