• 제목/요약/키워드: transmission line model

검색결과 531건 처리시간 0.022초

PCF법을 이용한 왕복동압축기의 진동원 및 진동전달경로 규명 (The Identification of Vibration Source and Its Transmission Paths In Compressor Using PCF Method)

  • Lee, Dae-Sung;Hwang, Won-Gul;Lee, You-Yub;Im, Hyung-Eun
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문초록집
    • /
    • pp.386.1-386
    • /
    • 2002
  • It is necessary to determine the vibration source and its transmission paths in order to develop a low-noise compressor Through the use of multiple-input/single-output(MISO) model, the transmission paths of vibration within a reciprocating compressor have been investigated. In order to identify the transmission path, we measure the accelerations of the block and transverse vibrations of the line discharge tube. (omitted)

  • PDF

AC/DC 하이브리드 선로의 전기환경특성 예측을 위한 축소모델 개발 (A Development of Reduced-scale Model to Predict of Environmental Characteristics of AC/DC Hybrid Overhead Transmission Line)

  • 최인혁;신구용;이동일;임재섭;김영홍;맹종호;주문노
    • 전기학회논문지
    • /
    • 제61권5호
    • /
    • pp.676-682
    • /
    • 2012
  • To review application of HVDC (High Voltage Direct Current) transmission line to HVAC T/L in operation, reduced-scale model was designed and manufactured. The arms of model were designed to change height and interval of conductors. Electrical environmental interferences were estimated by various configuration of AC 345kV and DC 250kV T/L. The interferences such as electric field intensity and ion current density were measured and converted reduced-scale factor to full-scaled. Additionally, effects between AC and DC T/L were studied.

축소모델을 이용한 STATCOM의 제어효과 및 계통응답 분석 (Analysis of Control and Performance Response of System using Scaled Model for STATCOM)

  • 유현호;한영성;박상태;오관일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.199-201
    • /
    • 2000
  • This paper describes the theory and experimental result of scaled model of STATCOM. The STATCOM, a solid-state voltage source inverter coupled with a transformer, is tied to a transmission line. A STATCOM inject an almost sinusoidal current of variables magnitude, at the pont of connection. This injected current is almost in quadrature with the line voltage, thereby emulating an inductive or capacitive reactance at the point of connection with the transmission line.

  • PDF

주기구조가 결합된 전송선로의 특성 임피던스 계산 (Calculation of the Characteristic Impedance of Transmission Lines with Periodic Structures)

  • 임종식;이재훈;이 준;한상민;안 달
    • 한국산학기술학회논문지
    • /
    • 제11권7호
    • /
    • pp.2541-2548
    • /
    • 2010
  • 본 논문에서는 결함접지구조와 포토닉 밴드갭과 같은 주기구조가 삽입된 전송선로의 특성 임피던스 계산에 대하여 기술한다. ${\lambda}$/4 전송선로 이론을 이용한 계산하는 종래 방법을 고찰하고, 이 방법에 의한 계산 결과가 주파수 의존성이 커서 신뢰도가 낮다는 문제점을 제시한다. 균일한 유전체 기판에 구현된 전송선로의 특성 임피던스 계산에 적용되는 해석적인 방법을 주기구조가 결합된 전송선로에서도 적용될 수 있음을 보인다. ${\lambda}$/4 전송선로 방법과 대신 해석적 방법으로 특성 임피던스를 구하고, 후자의 결과가 주파수에 관계없이 비교적 고정된 값을 가짐을 제시한다. 또한 종래에 특성 임피던스 계산 사례가 없었던 PBG 구조를 지닌 전송선로에 대해서도 특성 임피던스를 계산한다. 시뮬레이션뿐만 아니라 직접 제작하여 측정한 S-파라미터로부터 각각 특성 임피던스를 계산하고 서로 비교하여 상당히 유사함을 보인다. 그리고 이를 통하여 해석적 방법에 의한 특성 임피던스의 결정 방법이 DGS와 PBG와 같은 주기구조가 결합된 전송선로의 특성 임피던스 계산에 잘 적용될 수 있음을 보인다.

765 kV 송전선로 보호를 위한 아크사고 시뮬레이션 및 적응적 자동재폐로 대책 (The Arcing Faults Simulation and Adaptive Autoreclosure Strategy for 765 kV Transmission Line Protection)

  • 안상필;김철환
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권11호
    • /
    • pp.1365-1373
    • /
    • 1999
  • In many countries including Korea, in order to transmit the more electric power, the higher transmission line voltage is inevitable. So, a rapid reclosing scheme is important for EHV/UHV transmission lines to ensure requirements for high reliability of main lines. A critical aspect of reclosing operation is the extinction of the secondary arc since it must extinguish before successful reclosure can occur. Therefore the accurate simulation techniques of arcing faults are of importance. And successful reclosing switching can be accomplished by adopting a proper method such as HSGS and hybrid scheme to reduce the secondary arc extinction time. First of all, this paper discusses a suggested arc model, which have time dependent resistance for primary arc and piecewise linear approximated arc model for secondary arc. And this simulation technique is applied to Korean 765 kV transmission lines. Also hybrid scheme is simulated and evaluated for the purpose of shortening dead time. For adaptive reclosing scheme, variable dead time control algorithm is suggested. Two kinds of algorithm are tested. One is max tracking algorithm and the other is rms tracking algorithm. According to simulation results, rms tracking has less errors than max tracking. Therefore rms tracking is applied to Korean 765 kV transmission lines with hybrid scheme.

  • PDF

Integrated Optimization of Combined Generation and Transmission Expansion Planning Considering Bus Voltage Limits

  • Kim, Hyoungtae;Kim, Wook
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권4호
    • /
    • pp.1202-1209
    • /
    • 2014
  • A novel integrated optimization method is proposed to combine both generation and transmission line expansion problem considering bus voltage limit. Most of the existing researches on the combined generation and transmission expansion planning cannot consider bus voltages and reactive power flow limits because they are mostly based on the DC power flow model. In this paper the AC power flow model and nonlinear constraints related to reactive power are simplified and modified to improve the computation time and convergence. The proposed method has been successfully applied to Garver's six-bus system which is one of the most frequently used small scale sample systems to verify the transmission expansion method.

765 kV 교류 2회선 송전선 하의 인체 및 자동차에 유도되는 전압, 전류 계산 (Calculation of the induced voltage and current for a human and a car close to 765 kV AC double circuit transmission line)

  • 민석원;김응식;명성호;이병윤;박종근
    • 대한전기학회논문지
    • /
    • 제45권2호
    • /
    • pp.301-309
    • /
    • 1996
  • This paper estimates the electric field effect near 765[kV] AC double transmission line with numerical data. The induced voltage and current of a human and car under who kinds of phase arrangement are calculated when each of two objects is insulated or grounded. When the calculated results of the low-reactance and superposition phase arrangement are compared, it is proved that the induced voltage and current of the former are about 30 [%] smaller than that of the latter. The induced current of a human and car are less than 0.5[mA] which is about 10[%] less than that of the American National Standard Code. Also the induced voltage and current of dead lines by other live lines are calculated. Finally the effective number and position of shield wires to reduce the field in ground level are considered. charge simulation method and surface charge method are used to simulate the 2 or 3 dimensional transmission line model respectively.

  • PDF

SSSC를 이용한 전력조류제어에 관한 연구 (A Study of the Power Flow Control Using SSSC)

  • 나완기;정재길;이인용;정인학;이홍주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.239-241
    • /
    • 2000
  • This paper describes a modeling of a FACTS(Flexible AC Transmission System) device, namely, SSSC(Static Synchronous Series Compensator) model. The SSSC, a solid-state voltage source inverter coupled with a transformer, is connected in series with a transmission line. SSSC provides controllable compensating voltage, which is in quadrature with the line current, over an capacitive and an inductive range, independently of the magnitude of the line current. This SSSC model is obtained from the injection model for series connected VSC(Voltage Source Converter) by adding a constraint that the injected voltage should be in quadrature with the line current. The paper discusses the basic operating and performance characteristics of the SSSC, and power flow control in power system.

  • PDF

송전선로의 고장점 표정 알고리즘 (An Algorithm of fault Location Technique for Long Transmission Line)

  • 박철원;김삼룡;신명철;남시복;이복구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.145-147
    • /
    • 2002
  • In this paper, the improved fault locating method using distributed parameter which calculating the reduced voltage and current according to the ground capacitance in long transmission line was proposed. For the purpose of the fault locating algorithm non influenced source impedance, the loop method was used in the system modeling analysis. To enhance the fault locating, zero sequence of the fault current which is variable according to ground capacitance was not used but positive and negative sequence. System model was simulated using EMTP software. To verify the accuracy of proposed method, in different cases 64 sampled data per cycle was used and 160km and 300km long transmission line has fault resistance $0{\Omega}\;and\;100{\Omega}$ respectively was compared.

  • PDF

전송선로 모델을 이용한 마이크로스트립 슬롯 배열 안테나 설계 (Microstrip Slot Array Antenna Design by Using Tansmission Line Model)

  • 한석진;박익모;신철재
    • 한국전자파학회논문지
    • /
    • 제11권4호
    • /
    • pp.610-618
    • /
    • 2000
  • 본 논문은 T-모양 급전션을 갖는 마이크로스트립 슬롯 안테나를 전송선로 모델로 해석을 하였다. 마이크로스 트립 선로와 슬롯 선로의 접합변을 트랜스포머로 모델링을 하였으며 실험적인 방법으로 트랜스포머의 turn ratio 를 유도하였다. 전송선로 모델을 이용하여 단일 안테나뿐만 아니라 $1\times2,l\times4$ 배열 안테나를 해석하여 설계하 였고 제착하여 전송선로 모델로 계산한 반사손실 값과 측정값의 비교를 통해 전송선로 모텔이 안테나 설계에 유 용함을 입증하였다. 측정한 단일 안테나, $1\times2,l\times4$배열 안테나의 대역폭은 VSWR $\leq2$를 기준으로 하여 각각 2 28.5%, 47.8% 50.9% 였고 $1\times4$배열 안테나의 E-명변에서 주빔의 3dB 빔폭은 약$27^{\circ}$ 이득은 7.97 dBi 였다.

  • PDF