• 제목/요약/키워드: transmission dynamics

검색결과 234건 처리시간 0.04초

개선된 충격해머의 동역학적 모델 (Improved dynamic model of the impact hammer)

  • Lim, Byoung-Duk;Park, Jung-Hyun;Heo, Joon-Hyeok
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문초록집
    • /
    • pp.372.1-372
    • /
    • 2002
  • Although impact hammer is widely used as a convenient excitation tool in structural modal testing, little is known about the dynamic charateristics of its impulse mechanism. Transmission of the impulsive force to the structure depends on the dynamic properties of the impact hammer as well as the stiffness of the tip. An improved dynamic model of the impact hammer is proposed in this study with numerical simulations based on this model. (omitted)

  • PDF

Dynamic Analysis of Timing Silent Chain System for a V-type Engine of a Vehicle

  • Feng, Zengming;Tang, Lechao;Li, Jun;Jia, Yanhui
    • 대한기계학회논문집 C: 기술과 교육
    • /
    • 제3권2호
    • /
    • pp.89-96
    • /
    • 2015
  • Based on multi-body dynamic software RecurDyn, this paper proposes a modified form of timing silent chain system combing with the existing problem that vibration and chain tension is too large, which is applied for complicated conditions in a V-type engine, such as high speed, variable loads. The analysis of chain drive meshing characteristics is completed. Using the multi-body dynamic soft-ware RecurDyn, the dynamics characteristics of the improved system is studied, including chain tension, transmission error, chain fluctuations, equivalent spring force in different operating conditions. The study results show that chain tension, transmission error, chain fluctuation and equivalent spring force are within the scope of permission, all of them can meet the design requirement. There-fore, the design of this system is reasonable and practicable. The research results will provide a basis for assessing timing silent chain system in a V-type engine and a theoretical reference for designing and optimizing the timing silent chain system.

듀얼클러치 변속기용 습식클러치 체결에 따른 토크 변화에 대한 동적거동 (Characteristic Dynamics Torque Vibration of Behavior in Wet Clutch Engagement for Dual Clutch Transmissions)

  • 조재철;김우정;장재덕;장시열
    • 한국자동차공학회논문집
    • /
    • 제24권2호
    • /
    • pp.183-190
    • /
    • 2016
  • Engine torque is transferred to the transmission where drag torque is minimized improving fuel efficiency. This is particularly true in a wet clutch pack. This study measures slip friction when the wet clutch pack in a DCT (Dual-Clutch Transmission) is disengaged, and the friction pads are slipping. Shudder engagement velocity, and applied forces can be measured under various working conditions through these torque transfer experiments. Test results demonstrate that the design parameters, and engagement conditions of wet clutch packs can be optimized to reduce shudder and frictional vibration during engagement in a dual clutch transmission.

하드디스크 드라이브에 있어서 스핀들모터의 구조적 가진에 따른 시스템의 소음 특성에 관한 연구 (A Study On The Acoustic Noise Characteristics of Hard Disk Drive Due To The Structural Excitation Of Spindle Motor)

  • 손영;황태연;강성우;한윤식;구자춘
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.1549-1554
    • /
    • 2000
  • HDD structure is excited by the dynamic motion of disk-spindle motor components. Those excitations which are generated at stator and magnet rotor, at bearings and from disk dynamics, are transmitted through motor spindle and flange to HDD cover and base. The operational deflection shape measurement can show the structural excitation patterns at the most influent frequency on the acoustic noise level. One of those components is the axial excitation along spindle, and the other is the local orbital excitation at contact area of motor flange and base. To make a reduction of those structural transmission excitations, the structure of spindle motor is modified to the direction of reinforcement at transmission path without change of bearings, magnet and coil. Some excitation of spindle motor component carrying out essential function is unavoidable. So it is the efficient way of HDD noise improvement to control the structural transmission of excitation.

  • PDF

제어기강성이 로봇관절의 진동에 미치는 영향 (The Effects of Controller Stiffness on the Vibration of Robot Joints)

  • 경현태;김재원;김문상
    • 대한기계학회논문집
    • /
    • 제18권2호
    • /
    • pp.260-270
    • /
    • 1994
  • With the prevalent use of robot, the interests in moving speed of robot have been increasing for the purpose of upgrading performance of production. But the faster robot manipulator moves, the worse working accuracies are. And mechanical vibration is more and more serious with the increment of the moving speed of robot. So, the study on the cause and control method of robot vibration is one of the points of issue in robotics. This paper focuses on the vibration of 3 DOF parallel link drive mechanism robot. We assume that links of robot manipulator are `rigid' and joints are `flexible elements'. Governing equations of robot system including controller, servo amplifier, D.C servo motor, transmission with elasticity, and manipulator dynamics are derived. On the basis of modelling, we define `controller stiffness' by the proportional gain of controller and `stiffness of transmission'. Numerical and experimental research is performed to study vibration phenomena of robot induced from the variation of these two defined stiffnesses, and its results are shown.

다이나모 시험용 지게차 변속 및 정속 내구시험 제어기 개발 (A Development of Forklift Shift and Constant Speed Endurance Test Controller for Dynamometer Test)

  • 정규홍;이근호
    • 유공압시스템학회논문집
    • /
    • 제4권3호
    • /
    • pp.13-21
    • /
    • 2007
  • A forklift is a motive machine powered by LPG, diesel engine or electric motors. The internal combustion engine type forklift is equipped with automatic transmission to meet the required drive load as well as the easy operation of the vehicle. This paper deals with the shift control and endurance test controller which is developed for the functional test of the newly designed automatic transmission on a dynamometer test bench. Its major function is to control the proportional solenoid currents, which is directly related to clutch pressures, for the given reference current trajectory during shift and sequential operation of shift schedule designed for the durability test at each gear. It also has the ability to monitor all the necessary test data through RS232 communication and log them to disk files. The current controller of embedded system is designed from the identified dynamics of solenoid coil and the current reference can be easily modified with a user interface software on PC so as to match the shift data by experiments.

  • PDF

Space Charge Behavior of Oil-Impregnated Paper Insulation Aging at AC-DC Combined Voltages

  • Li, Jian;Wang, Yan;Bao, Lianwei
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권2호
    • /
    • pp.635-642
    • /
    • 2014
  • The space charge behaviors of oil-paper insulation affect the stability and security of oil-filled converter transformers of traditional and new energies. This paper presents the results of the electrical aging of oil-impregnated paper under AC-DC combined voltages by the pulsed electro-acoustic technique. Data mining and feature extractions were performed on the influence of electrical aging on charge dynamics based on the experiment results in the first stage. Characteristic parameters such as total charge injection and apparent charge mobility were calculated. The influences of electrical aging on the trap energy distribution of an oil-paper insulation system were analyzed and discussed. Longer electrical aging time would increase the depth and energy density of charge trap, which decelerates the apparent charge mobility and increases the probability of hot electron formation. This mechanism would accelerate damage to the cellulose and the formation of discharge channels, enhance the acceleration of the electric field distortion, and shorten insulation lifetime under AC-DC combined voltages.

UPFC를 포함한 송전성에서의 전류차동 보호 방식의 개선 (Improvement of the Differential Current Relaying Method for Protecting the Transmission Line Equipped with UPFC)

  • 임정욱;권영진
    • 조명전기설비학회논문지
    • /
    • 제19권8호
    • /
    • pp.40-47
    • /
    • 2005
  • 본 논문에서는 대표적인 유연송전기기인 UPFC(Unified Power flow Controller)를 대상으로 UPFC 운전이 송전계통에 미치는 영향을 분석하여 송전선 보호를 위한 전류차동방식을 개선하였다. UPFC가 포함된 송전계통을 대상으로 UPFC의 여러 운전 모드에 대한 동적 해석을 통하여 UPFC 동적 특성이 송전선 보호를 위한 전류차동 계전방식에 미치는 영향을 분석하였다. 이를 바탕으로 UPFC가 운전하고 있을 때의 고장을 효과적으로 판단할 수 있도록 개선된 전류차동 보호방법을 제안하였고, 제안된 방법의 타당성을 시뮬레이션으로 입증하였다.

Response of transmission line conductors under different tornadoes

  • Dingyu Yao;Ashraf El Damatty;Nima Ezami
    • Wind and Structures
    • /
    • 제37권3호
    • /
    • pp.179-189
    • /
    • 2023
  • Multiple studies conducted in the past evaluated the conductor response under one tornado wind field, while the performance of transmission lines under different tornado wind fields still remains unknown. Thus, the objective of this paper is to estimate the variation in the conductor's critical longitudinal and transverse reactions under different tornado wind fields, as well as providing the corresponding critical tornado configurations. The considered full-scale tornadoes are the Spencer, South Dakota, 1998, the Stockton, Kansas, 2005 and the Goshen County, Wyoming, 2009. Computational Fluid Dynamics (CFD) simulations were previously conducted to develop these wind fields. All tornadoes have been rescaled to have a common velocity matching the upper limit of the F2 Fujita scale. Eight conductor systems, each including six spans, are considered in this paper. For each conductor, parametric studies are conducted by varying the location of the three tornado wind fields relative to the tower of interest, therefore the peak reactions associated with each tornado are determined. A semi-analytical closed-form solution, previously developed and validated, is used to calculate the reactions. The study conducted in this paper can be divided into two parts: In the first part, a parametric study considering a wide range of tornado locations is conducted. In the second part, the parametric study focuses on the tornado location leading to the critical tangential velocity on the tower. Based on this extensive parametric study, a critical tornado defined as the Design Tornado and its critical locations, tornado distance R = 125 m, tornado angle 𝜃 = 15° and 30°, are recommended for design purposes.

Behaviour and design of guyed pre-stressed concrete poles under downbursts

  • Ibrahim, Ahmed M.;El Damatty, Ashraf A.
    • Wind and Structures
    • /
    • 제29권5호
    • /
    • pp.339-359
    • /
    • 2019
  • Pre-stressed concrete poles are among the supporting systems used to support transmission lines. It is essential to protect transmission line systems from harsh environmental attacks such as downburst wind events. Typically, these poles are designed to resist synoptic wind loading as current codes do not address high wind events in the form of downbursts. In the current study, the behavior of guyed pre-stressed concrete Transmission lines is studied under downburst loads. To the best of the authors' knowledge, this study is the first investigation to assess the behaviour of guyed pre-stressed concrete poles under downburst events. Due to the localized nature of those events, identifying the critical locations and parameters leading to peak forces on the poles is a challenging task. To overcome this challenge, an in-house built numerical model is developed incorporating the following: (1) a three-dimensional downburst wind field previously developed and validated using computational fluid dynamics simulations; (2) a computationally efficient analytical technique previously developed and validated to predict the non-linear behaviour of the conductors including the effects of the pretension force, sagging, insulator's stiffness and the non-uniform distribution of wind loads, and (3) a non-linear finite element model utilized to simulate the structural behaviour of the guyed pre-stressed concrete pole considering material nonlinearity. A parametric study is conducted by varying the downbursts locations relative to the guyed pole while considering three different span values. The results of this parametric study are utilized to identify critical downburst configurations leading to peak straining actions on the pole and the guys. This is followed by comparing the obtained critical load cases to new load cases proposed to ASCE-74 loading committee. A non-linear failure analysis is then conducted for the three considered guyed pre-stressed concrete transmission line systems to determine the downburst jet velocity at which the pole systems fail.