• 제목/요약/키워드: transmission dose

검색결과 218건 처리시간 0.024초

The Lowest Dose for CT Attenuation Correction in PET/CT

  • Kang, Byung-Sam;Son, Jin-Hyun;Park, Hoon-Hee;Dong, Kyung-Rae
    • 대한디지털의료영상학회논문지
    • /
    • 제13권3호
    • /
    • pp.111-115
    • /
    • 2011
  • PET/CT(Positron Emission Tomography/Computed Tomography) is an examination combining morphological and functional information in one examination. The purpose of this study is to see the lowest CT dose for attenuation correction in the PET/CT maintaining good image quality when considering CT scan dose to the patients. We injected $^{18}F$-FDG and water into the cylinder shaped phantom, and obtained emission images for 3 mins and transmission images(140 kVp, 8 sec, 10~200 mA for transmission images), and reconstructed the images to PET/CT images with Iterative method. Data(Maximum, Minimum, Average, Standard Deviation) were obtained by drawing a circular ROI(Region Of Interest) on each sphere in each image set with Image J program. And then described SD according to the CT and PEC/CT images as graphes. Through the graphes, we got the relationships of mA and quality of images. SDs according to CT graph were 16.25 at 10 mA, 7.26 at 50 mA, 5.5 at 100 mA, 4.29 at 150 mA, and 3.83 at 200 mA, i.e. the higer mA, the better image quality was presented. SDs according to PET/CT graph were 1823.2 at 10 mA, 1825.1 at 50 mA, 1828.4 at 100 mA, 1813.8 at 150 mA, and 1811.3 at 200 mA. Calculated SDs at PET/CT images were maintained. This means images quality is maintained having nothing to do with mA of high and low.

  • PDF

DYNAMIC WEDGE의 임상 적용 가능성에 관한 고찰

  • 김영범;정세영;황웅구
    • 대한방사선치료학회지
    • /
    • 제7권1호
    • /
    • pp.103-110
    • /
    • 1995
  • Dynamic wedge system has been introduced to modify the beam profile and to make homogeneous isodose curves in the mass of irregular shape. Before the clinical use of dynamic wedge, several factors such as wedge transmission factor, dose profile, percent depth dose, and wedge angle have to be measured quantitatively. Film dosimetry is used to evaluate these factors in this study. A comparison of the result of the dynamic wedge to physical wedge system is made. A positive result for the application of the dynamic wedge to clinic is derived even though there is a limitation in accuracy of the dosimetry system used. To measure all factors quantitatively, more accurate dosimetry systems are required.

  • PDF

전송선 이론에 의한 적외선 흡수 구조체의 흡수율 모의시험 (Modeling and simulation on an IR absorbing structure with the cascaded transmission line model)

  • 박승만
    • 전기학회논문지
    • /
    • 제62권12호
    • /
    • pp.1725-1729
    • /
    • 2013
  • In this paper, the modeling and simulation of infrared absorption in an infrared absorbing structure with the cascaded transmission line model were carried out. Each layer in the infrared absorbing structure can be modeled as a characteristic impedance of the cascaded transmission line model. The simulation results show that the cavity thickness to get a maximum absorption should be less than a quarter wavelength, which is somewhat different from prevalent thickness. It can be assured that the sheet resistance of an absorbing layer to get a maximum absorption is $377{\Omega}/{\square}$, that the thickness of the absorbing layer dose not affect the spectral characteristics of absorption. It is also shown that the thickness of the active layer is not critical to the IR absorption. It can also be assured that the validation of this modeling is proved in comparison with the previous results from similar absorbing structures.

The Properties of Beam Intensity Scanner(BInS) in IMRT with Phantom for Three Dimensional Dose Verification

  • Young W. Vahc;Park, Kwangyl;Byung Y. Yi;Park, Kyung R.;Lee, Jong Y.;Ohyun Kwon;Park, Kwangyl;Kim, Keun M.
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2003년도 제27회 추계학술대회
    • /
    • pp.64-64
    • /
    • 2003
  • Objectives: Patient dose verification is clinically the most important parts in the treatment delivery of radiation therapy. The three dimensional(3D) reconstruction of dose distribution delivered to target volume helps to verify patient dose and determine the physical characteristics of beams used in intensity modulated radiation therapy(IMRT). We present Beam Intensity Scanner(BInS) system for the pre treatment dosimetric verification of two dimensional photon intensity. The BInS is a radiation detector with a custom made software for relative dose conversion of fluorescence signals from scintillator. Methods: This scintillator is fabricated by phosphor Gadolinium Oxysulphide and is used to produce fluorescence from the irradiation of 6MV photons on a Varian Clinac 21EX. The digitized fluoroscopic signals obtained by digital video camera will be processed by our custom made software to reproduce 3D relative dose distribution. For the intensity modulated beam(IMB), the BInS calculates absorbed dose in absolute beam fluence, which are used for the patient dose distribution. Results: Using BInS, we performed various measurements related to IMRT and found the followings: (1) The 3D dose profiles of the IMBs measured by the BInS demonstrate good agreement with radiographic film, pin type ionization chamber and Monte Carlo simulation. (2) The delivered beam intensity is altered by the mechanical and dosimetric properties of the collimating of dynamic and/or static MLC system. This is mostly due to leaf transmission, leaf penumbra, scattered photons from the round edges of leaves, and geometry of leaf. (3) The delivered dose depends on the operational detail of how to make multileaf opening. Conclusions: These phenomena result in a fluence distribution that can be substantially different from the initial and calculative intensity modulation and therefore, should be taken into account by the treatment planing for accurate dose calculations delivered to the target volume in IMRT.

  • PDF

Real-time monitoring of ultra-high dose rate electron beams using bremsstrahlung photons

  • Hyun Kim;Dong Hyeok Jeong;Sang Koo Kang;Manwoo Lee;Heuijin Lim;Sang Jin Lee;Kyoung Won Jang
    • Nuclear Engineering and Technology
    • /
    • 제55권9호
    • /
    • pp.3417-3422
    • /
    • 2023
  • Recently, as the clinically positive biological effects of ultra-high dose rate (UHDR) radiation beams have been revealed, interest in flash radiation therapy has increased. Generally, FLASH preclinical experiments are performed using UHDR electron beams generated by linear accelerators. Real-time monitoring of UHDR beams is required to deliver the correct dose to a sample. However, it is difficult to use typical transmission-type ionization chambers for primary beam monitoring because there is no suitable electrometer capable of reading high pulsed currents, and collection efficiency is drastically reduced in pulsed radiation beams with ultra-high doses. In this study, a monitoring method using bremsstrahlung photons generated by irradiation devices and a water phantom was proposed. Charges collected in an ionization chamber located at the back of a water phantom were analyzed using the bremsstrahlung tail on electron depth dose curves obtained using radiochromic films. The dose conversion factor for converting a monitored charge into a delivered dose was determined analytically for the Advanced Markus® chamber and compared with experimentally determined values. It is anticipated that the method proposed in this study can be useful for monitoring sample doses in UHDR electron beam irradiation.

유방암 환자에서 가상 쐐기모양 보상체의 선량분포 특성에 대한 연구 (A Study on Dose Distribution using Virtual Wedge in Breast Cancer)

  • 윤상모;김성규
    • 한국의학물리학회지:의학물리
    • /
    • 제18권1호
    • /
    • pp.7-12
    • /
    • 2007
  • 유방암 환자의 방사선치료에서 유방의 모양에 따른 윗부분과 아랫부분의 두께의 차이 때문에 적절한 선량분포를 얻기 위해서는 쐐기모양 보상체가 필수적으로 이용된다. 유방보존절제술을 시행한 유방암 환자들을 방사선치료 할 때 일반적으로 비껴방향 치료방법으로 치료를 한다 비껴방향 치료방법에서 중심 쪽에서 가장자리 쪽으로 치료하는 빔에서는 쐐기모양 보상체에 빔이 일차적으로 부딪칠 때 저에너지의 방사선이 발생하여 피부에 영향을 미치게 된다. 이 때 피부에 조사되는 저 에너지 방사선을 최소화하기 위하여 가상 쐐기모양 보상체를 사용할 수 있다. 본원이 보유하고 있는 Eclipse 치료계획장치에는 가상 쐐기모양 보상체로 치료계획을 할 수 있도록 장착되어 있다. 저자들은 본원이 갖고 있는 실제 쐐기모양 보상체 15도, 30도, 45도, 60도와 가상 쐐기모양 보상체 15도, 30도, 45도, 60도의 선량분포 특성을 비교하여 유방암 환자에서 가상 쐐기모양 보상체의 임상 적용 타당성을 살펴본 결과 치료면적 $10{\times}10cm$의 대칭도의 비교에서 쐐기의 각도에 따른 차이가 없음을 알 수 있었으며, 치료면적의 크기에 따른 각각의 쐐기 각도에 대한 투과율의 특성에서 대칭도의 비교는 거의 선형적으로 변함을 볼 수 있어 가상 쐐기의 임상적용이 적합함을 알 수 있었다.

  • PDF

고에너지 방사선치료용 on-line 선량측정시스템을 위한 알고리즘의 개발 (Development of the Algorithm for On-line Dosimetry System for High Energy Radiation Treatment)

  • 우홍균;하성환
    • Journal of Radiation Protection and Research
    • /
    • 제22권3호
    • /
    • pp.207-218
    • /
    • 1997
  • 목적 : 고에너지 방사선치료용 on-line 선량측정시스템의 개발의 일부로서, 측정된 투과선량을 이용하여 종양선량을 계산하는데 필요한 알고리즘의 개발이 목적이다. 방법 첫번째로 다양한 크기의 조사야 (FS), 다양한 두께의 phantom (Tp), 다양한 거리의 phantom to chamber distance (PCD)에서 6 MV 및 10 MV X-선에 대하여 특수 제작한 water phantom을 대상으로 phantom의 후방에서 투과선량을 측정하여 기본적인 beam data를 얻었다. 선원-측정기간 거리는 150cm으로 고정시켰다. 측정은 0.125cc ion chamber를 이용하였다. 두번째로 노출환경 (조사야의 크기, phantom의 두께, PCD)과 측정치와의 상관관계에 대한 알고리즘을 개발하고, 마지막으로 측정치와 알고리즘에 의한 예상치를 비교하여 알고리즘의 정확성을 평가하였다. 결과 : 측정데이터를 이용하여 회귀분석을 시행해서 두가지 알고리즘을 개발하였다. 알고리즘 1은 PCD에 대한 2차 함수와 A/P (area-perimeter ratio)에 대한 3차 함수로 이루어져 있으며, 알고리즘 2는 log(A/P)에 대한 3차 함수와 PCD에 대한 3차 함수로 이루어져 있다. 알고리즘 1에서는 측정치와 예상치의 오차가 1.0% 미만이었고, 알고리즘 2에서는 측정치와 예상치의 오차가 거의 0.5% 미만이었다. 또한 알고리즘 2는 알고리즘 1을 사용할 때보다 적은 data를 가지고서도 더욱 정확하게 fitting 할 수 있었다. 따라서 fitting 상수들을 구하는데 필요한 측정시간을 알고리즘 1을 사용할 때보다 반으로 줄일 수 있었다. 결론 : phantom의 후방에서 측정한 투과선량을 이용하여, 임의의 Tp, PCD, FS에서 투과선량을 정확하게 예측할 수 있는 두가지의 알고리즘을 개발하였다. 향후 보조 장치에 의한 영향, 조사야 차폐의 영향, 신체조직의 조직특성 (불균일도, inhomogeneity), 신체 형태의 굴곡에 대한 연구를 완성하면 매치료시마다 종양에 흡수된 방사선량을 확인할 수 있는 on-line dosimetry가 가능할 것이다.

  • PDF

Vacuum Cushion 사용시 표면선량과 투과율 평가 (Surface Dose and Transmission Factor for Vacuum Cushion)

  • 김미화;이병용;전미선
    • 한국의학물리학회지:의학물리
    • /
    • 제13권2호
    • /
    • pp.74-78
    • /
    • 2002
  • 환자 치료시 환자의 위치고정과 매번 치료에서 환자 치료 자세의 재현을 위해 사용하는 고정물(immobilizer)중 Vacuum cushion을 사용시 Vacuum cushion으로 인해 예상되는 표면선량 또는, 투과량의 변화들을 측정하여 Vacuum cushion의 특성을 평가하였다. 광자선 에너지 4 MV (Varian 4/100, 미국), 6MV, 15 MV (Varian CL2100C/D, 미국)에 대해서 조사면의 크기를 5$\times$5, 10$\times$10, 20$\times$20, 30$\times$30, 40$\times$40 $\textrm{cm}^2$로, Vacuum cushion의 두께는 12, 32, 48 mm, 그리고 스티로폼이 없이 진공 봉지만 있는 경우로 변화해가며 Vacuum cushion에 대해 팬톰 표면에서 d$_{max}$까지의 선량을 측정하였다. 그 결과 vacuum cushion 두께에 대한 투과율은 0.9953-1.0043의 분포로 거의 차이가 없었다. 그리고 vacuum cushion의 두께가 두꺼워질수록, 환자가 받는 표면 선량은 증가하였다. 에너지, 조사면 크기에 대해 Vacuum cushion의 두께에 따라 표면 선량의 변화가 있었으나 6 MV와 15 MV에 대해 알려진 aquaplast의 데이타와 가장 두꺼운(48mm) vacuum cushion의 표면선량 증가율을 비교시 aquaplast보다 대략 16, 12% 낮아 임상에 적용하는데 무리가 있을 만큼 심각한 문제가 아니었다.

  • PDF