• Title/Summary/Keyword: transmission distribution

Search Result 1,550, Processing Time 0.023 seconds

A study on the Fault Location Technique for Transmission Line System (송전선로의 고장점 표정기법에 관한 연구)

  • Kim, S.R.;Park, C.W.;Shin, M.C.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.255-257
    • /
    • 2001
  • This paper describes an accurate fault location algorithm based on current distribution factors. To prove the effectiveness of proposed method, we used by simulation data from EMTP. The proposed algorithm using the current distribution factors is independent of fault resistance and load flow variation.

  • PDF

A STUDY OF THE STRESS TRANSMISSION OF VARIOUS ARTIFICIAL TEETH AND DENTURE BASE MATERIALS TO THE UNDER-LYING SUPPORTING TISSUES (인공치와 의치상의 재질에 따른 의치상 하부 지지조직에의 응력전달에 관한 연구)

  • Chung, Hyun-Gun;Chung, Moon-Kyu;Lee, Ho-Yong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.27 no.2
    • /
    • pp.79-100
    • /
    • 1989
  • The Purpose of this study was to investigate material differences in stress transmission among various artificial teeth and denture base materials. For this study, a two-dimensional finite element model and a two-dimensional photoelastic model of a mandible with complete denture were made. A resin tooth and a porcelain tooth were used as artificial teeth, and a resin base, a metal lined base, and a soft-liner lined base were used as denture bases. An occlusal load was applied and principal stresses generated in the supporting tissues were compared. To test the impact stress transmission, strain gauge attached to the denture base specimens made of the different materials were made in thick and thin groups. Voltage outputs from hitting the specimen with a steel ball were compared. The results were as follows : 1. In FEM, increasing the mucosal thickness reduced the maximum principal stresses in the supporting tissues, but altering the tooth materials and the base materials induced no difference in the stresses. 2. In photoelastic model study, no difference in fringe order among the specimens were observed, but the thick mucosa group and the soft-liner lined group revealed a more uniform distribution of the load. 3. In strain measuring, the impact force transmission was highest in the soft-liner lined group, and was the lowest in the metal lined group(p<0.01). 4. In the thin group using the resin base, the porcelain tooth showed higher impact stress transmission than the resin tooth(p<0.01), but no difference was observed between them in the thick group. In the soft-liner lined group, the porcelain tooth showed higher impact stress transmission than the resin tooth(p<0.01), but no difference was observed between them in the metal lined group. 5. The thick group showed lower impact stress transmission than the thin group(p<0.01).

  • PDF

Stress Analysis of the S-CVT using Finite Element Method (FEM을 이용한 구체무단변속기의 응력해석)

  • Kim, J.Y.
    • Journal of Power System Engineering
    • /
    • v.12 no.2
    • /
    • pp.41-47
    • /
    • 2008
  • This article deals with the stress analysis of the friction drive, which transmits the power via the rolling resistance on the contract area between the two rotating bodies. On the contact area, friction drives are normally involved with shear stress due to the transmitted force, as well as normal stress. Thus the stress analysis including the shear stress is necessary for the design of the friction drive. Hertzian results can be used to estimate the normal stress distribution and elastic deflection of the contact area, although the shear stress distribution is not well defined. In order to investigate the shear stress distribution and its effects in a friction drive, we have performed the stress analysis of the spherical continuously variable transmission(CVT) using finite element method. The spherical CVT is one of friction drives, which is used in small power applications. The numerical results show that the normal stress distribution is not affected by the transmitted shear force, and the maximal shear stress is increased in small amount along with the shear force.

  • PDF

The Measurement Systme of Vibration using Laser (레이져를 이용한 진동측정장치)

  • 진동희;전병철;조종두;김재도
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1993.10a
    • /
    • pp.357-362
    • /
    • 1993
  • In this study low priced laser measurement system was made, so its reliability was investigated Intensity distribution of laser beam measured by devised system and FFT analyzer and their results were examined for proving reliability of devised system. Transmitted laser beam intensity on photodiode changed by eccentrically rotating of disk cam and motor speed. To get results, photodiode and devised amplifier were used for changing voltage. After that, response signal was calculated by signal analysis program. It was found that the vibration of disk cam could be measured by the intensity distribution of laser beam and the same tendency was obtained by FFT. Change of motor speed effected the distribution of laser beam,which was obtained by devised system. Also linear distribution was got by sensitive balancing switch on amplifier according to the transmission of laser beam on photodide.

  • PDF

Analysis of Pricing Structure of Distribution-Retail Sale Company under Power System Deregulation (전력산업 경쟁체제에서 배전-판매회사의 요금구조 분석)

  • Shon, Hyoung-Suk;Ro, Kyoung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.401-403
    • /
    • 2002
  • Transmission and Distribution(T&D) pricing has been one of keystones of ongoing deregulation and privatization process in power industries. The electricity markel has been established based on open access and nondiscriminatory use of the T&D assets. As T&D business remains as a monopoly, it is necessary to provide economic regulation. This paper focuses on the distribution pricing methods and the analysis of pricing structure of distribution-retail sale company under power system deregulation.

  • PDF

An Application of Enhanced Genetic Algorithm to solve the Distribution System Restoration Problem (배전계통 사고복구 문제에 갠선된 유전 알고리즘 적용)

  • Lee, Jung-Kwan;Mun, Kyeong-Jun;Hwang, Gi-Hyun;Seo, Jeong-Il;Lee, H.S.;Park, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1123-1125
    • /
    • 1999
  • This paper proposes an optimization technique using Genetic Algorithm(GA) for service restoration in the distribution system. Restoration planning problem can be treated as a combinatorial optimization problem. So GA is appropriate to solve the service restoration problem in the distribution network. But searching capabilities of the GA can be enhanced by developing relevant repairing operation and modifying GA operations. In this paper, we aimed at finding appropriate open sectionalizing switch position for the restoration of distribution networks after disturbances using enhanced GA with repairing operation and modified mutation. Simulation results show that proposed method found the open sectionalizing switches with less out of service area and minimize transmission line losses and voltage drop.

  • PDF

A GEOSENSOR FILTER FOR PROCESSING GEOSENSOR QUERIES ON DATA STREAMS

  • Lee, Dong-Gyu;Ryu, Keun-Ho
    • Proceedings of the KSRS Conference
    • /
    • 2008.10a
    • /
    • pp.119-121
    • /
    • 2008
  • Pattern matching is increasingly being employed in various researches as health care service, RFID-based system, facility management, and surveillance. Geosensor filter correlates a data stream to match specific patterns in distribution environments. In this paper, we present a geosensor query language to represent efficiently declarative geosensor query. Geosensor operators are proposed to use for fast query processing in terms of spatial and temporal area in distribution environments. We also propose a geosensor filter to match new query predicates into incoming stream predicates. Our filter can reduce the volume of transmission data and save power consumption of sensors. It can be utilized the stream data mining system to process in real-time various data as location, time, and geosensor information in distribution environments.

  • PDF

UPFC Performance Control in Distribution Networks for DG Sources in the Islanding

  • Fandawi, Ahmed;Nazarpour, Daryoosh
    • Transactions on Electrical and Electronic Materials
    • /
    • v.18 no.5
    • /
    • pp.303-309
    • /
    • 2017
  • The flexible AC transmission system (FACTS) provides a new advanced technology solution to improve the flexibility, controllability, and stability of a power system. The unified power flow controller (UPFC) is outstanding for regulating power flow in the FACTS; it can control the real power, reactive power, and node voltage of distribution networks. This paper investigates the performance of the UPFC for power flow control with a series of step changes in rapid succession in a power system steady state and the response of the UPFC to distribution network faults and islanding mode. Simulation was carried out using the MATLAB's simulink sim power systems toolbox. The results, which were carried out on a 5-bus test system and a 4-bus multi-machine electric power system, show clearly the effectiveness and viability of UPFC in rapid response and independent control of the real and reactive power flows and oscillation damping [6].

Avoiding Energy Holes Problem using Load Balancing Approach in Wireless Sensor Network

  • Bhagyalakshmi, Lakshminarayanan;Murugan, Krishanan
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.8 no.5
    • /
    • pp.1618-1637
    • /
    • 2014
  • Clustering wireless sensor network is an efficient way to reduce the energy consumption of individual nodes in a cluster. In clustering, multihop routing techniques increase the load of the Cluster head near the sink. This unbalanced load on the Cluster head increases its energy consumption, thereby Cluster heads die faster and create an energy hole problem. In this paper, we propose an Energy Balancing Cluster Head (EBCH) in wireless sensor network. At First, we balance the intra cluster load among the cluster heads, which results in nonuniform distribution of nodes over an unequal cluster size. The load received by the Cluster head in the cluster distributes their traffic towards direct and multihop transmission based on the load distribution ratio. Also, we balance the energy consumption among the cluster heads to design an optimum load distribution ratio. Simulation result shows that this approach guarantees to increase the network lifetime, thereby balancing cluster head energy.

Reliability Evaluation of Distributed Generation and Distribution System Using Load Duration Curve (Load Duration Curve를 이용한 분산전원과 배전계통의 신뢰도 산출)

  • Bae, In-Su;Kim, Jin-O
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.11
    • /
    • pp.518-524
    • /
    • 2005
  • This paper presents an analytical method for the reliability evaluation of distribution system, including the distributed generations. Unlike the large sized generations of transmission system, the distributed generations have complexities in analyzing and determining the operation. In the process of evaluate reliability, it can be shown that the analytical method is simpler than the Monte-Carlo simulation and the method using Load Duration Curve model is more accurate than that using peak load model. The modeling of distributed generation to analysis distribution system reliability using LDC is proposed in this Paper, and is compared with the MCS method as a result of case studies.