• Title/Summary/Keyword: transmission distribution

Search Result 1,550, Processing Time 0.029 seconds

A Study on Discrimination of Watercore Apple using Transmitted Light and Effects of various Factors (투과광을 이용한 밀병 사과의 판별 가능성 및 영향인자 조사)

  • 손미령;정경원;조래광
    • Food Science and Preservation
    • /
    • v.7 no.4
    • /
    • pp.357-361
    • /
    • 2000
  • Watercore influences storage and distribution industry of fruit. Therefore, the technique for nondestructive discrimination of watercore fruit is needed. This work reports about the possibility of watercore discrimination of ante using transmitted light, and the effects of various factors. CCD camera was used to capone images of each apple fruit. An excess watercore apples were higher light transmission score than little watercore apples. The accuracy fur discrimination of watercore apple was about 70% using transmitted light. Peel thickness, anthocyanin layer thickness and density of apple affected the light transmission. Apples having thin peel, thin pigment layer and low density tended to high transmitted light score. Apples of good color degree were more probability of existence watercore than ones of bad color degree. But color distribution of apple peel was not correlated with watercore.

  • PDF

Uncertainty Analysis of Dynamic Thermal Rating of Overhead Transmission Line

  • Zhou, Xing;Wang, Yanling;Zhou, Xiaofeng;Tao, Weihua;Niu, Zhiqiang;Qu, Ailing
    • Journal of Information Processing Systems
    • /
    • v.15 no.2
    • /
    • pp.331-343
    • /
    • 2019
  • Dynamic thermal rating of the overhead transmission lines is affected by many uncertain factors. The ambient temperature, wind speed and wind direction are the main sources of uncertainty. Measurement uncertainty is an important parameter to evaluate the reliability of measurement results. This paper presents the uncertainty analysis based on Monte Carlo. On the basis of establishing the mathematical model and setting the probability density function of the input parameter value, the probability density function of the output value is determined by probability distribution random sampling. Through the calculation and analysis of the transient thermal balance equation and the steady- state thermal balance equation, the steady-state current carrying capacity, the transient current carrying capacity, the standard uncertainty and the probability distribution of the minimum and maximum values of the conductor under 95% confidence interval are obtained. The simulation results indicate that Monte Carlo method can decrease the computational complexity, speed up the calculation, and increase the validity and reliability of the uncertainty evaluation.

Mean wind loads on T-shaped angle transmission towers

  • Guohui Shen;Kanghui Han;Baoheng Li;Jianfeng Yao
    • Wind and Structures
    • /
    • v.38 no.5
    • /
    • pp.367-379
    • /
    • 2024
  • Compared with traditional transmission towers, T-shaped angle towers have long cross-arms and are specially used for ultrahigh-voltage direct-current (UHVDC) transmission. Nevertheless, the wind loads of T-shaped towers have not received much attention in previous studies. Consequently, a series of wind tunnel tests on the T-shaped towers featuring cross-arms of varying lengths were conducted using the high-frequency force balance (HFFB) technique. The test results reveal that the T-shaped tower's drag coefficients nearly remain constant at different testing velocities, demonstrating that Reynolds number effects are negligible in the test range of 1.26 × 104-2.30 × 104. The maximum values of the longitudinal base shear and torsion of the T-shaped tower are reached at 15° and 25° of wind incidence, respectively. In the yaw angle, the crosswind coefficients of the tower body are quite small, whereas those of the cross-arms are significant, and as a result, the assumption in some load codes (such as ASCE 74-2020, IEC 60826-2017 and EN 50341-1:2012) that the resultant force direction is the same as the wind direction may be inappropriate for the cross-arm situation. The fitting formulas for the wind load-distribution factors of the tower body and cross-arms are developed, respectively, which would greatly facilitate the determination of the wind loads on T-shaped angle towers.

Improving Hot Spot Problem in Layer of DL-LEACH

  • LEE, WooSuk;Jin, Seung Yeon;Jung, Kye-Dong;Lee, Jong-Yong
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.9 no.2
    • /
    • pp.64-69
    • /
    • 2017
  • The abstract should summarize the contents of the paper and written below the author information. Use th In Wide-area Wireless Sensor Networks, network lifetime is short due to energy consumption due to transmission distance. To improve this, we divide the sensor field into layers and reduce transmission distance through multi-hop transmission. However, there is a problem in that the transmission rate drops because there is no Cluster Head in the layer, or the transmission distance increases due to the layer, and energy is wasted. There are DL-LEACH and EDL-LEACH as Protocols to improve this. DL-LEACH uses either single-hop transmission or multi-hop transmission depending on the situation. As a result, the transmission distance is optimized, thereby reducing energy consumption. In case of EDL-LEACH, it is proposed to improve the data rate in DL-LEACH. It is the same as DL-LEACH, but the Cluster Head is mandatory for all layers to improve the transmission rate. Although there is no Cluster Head for each layer, the transmission rate is improved, but the network life is shortened. In this paper, we try to improve the network lifetime while maintaining the EDL-LEACH transmission rate. The shortened network lifetime is due to Cluster Head overload near the base station. To improve this, the Cluster Head distribution method is improved and the network lifetime is improved.

Analysis of Sequence Impedances of 345kV Cable Transmission Systems (실계통 345kV 지중송전선 대칭좌표 임피던스의 해석)

  • Choi, Jong-Kee;Ahn, Yong-Ho;Yoon, Yong-Beum;Oh, Sei-Ill;Kwa, Yang-Ho;Lee, Myoung-Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.7
    • /
    • pp.905-912
    • /
    • 2013
  • Power system fault analysis is commonly based on well-known symmetrical component method, which describes power system elements by positive, negative and zero sequence impedance. In case of balanced fault, such as three phase short circuit, transmission line can be represented by positive sequence impedance only. The majority of fault in transmission lines, however, is unbalanced fault, such as line-to-ground faults, so that both positive and zero sequence impedance is required for fault analysis. When unbalanced fault occurs, zero sequence current flows through earth and skywires in overhead transmission systems and through cable sheaths and earth in cable transmission systems. Since zero sequence current distribution between cable sheath and earth is dependent on both sheath bondings and grounding configurations, care must be taken to calculate zero sequence impedance of underground cable transmission lines. In this paper, conventional and EMTP-based sequence impedance calculation methods were described and applied to 345kV cable transmission systems (4 circuit, OF 2000mm2). Calculation results showed that detailed circuit analysis is desirable to avoid possible errors of sequence impedance calculation resulted from various configuration of cable sheath bonding and grounding in underground cable transmission systems.

Harmonic Distortion Contribution for the Transmission Loss Allocation in Deregulated Energy Market: A New Scheme for Industry Consumer

  • Nojeng, Syarifuddin;Hassan, Mohammad Yusri;Said, Dalila Mat;Abdullah, Md.Pauzi;Hussin, Faridah
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.1-7
    • /
    • 2015
  • The industry has rapidly growth and energy supply technology advanced are become main factor which to contribute of the harmonic losses. This problem is one aspect that may affect the capability of the transmission line and also to the efficiency of electricity. This paper proposes a new scheme to allocate the cost pertaining to transmission loss due to harmonics. The proposed method, called as Generalized Harmonic Distribution Factor, uses the principle of proportional sharing method to allocate the losses among the transmission users especially for industry consumers. The IEEE 14- and 30 bus test system is used to compare the proposed method with existing method. The results showed that the proposed method provided a scheme better in allocating the cost of transmission loss, which could encourage the users to minimize the losses.

Acoustic Study of light weight insulation system on Dash using SEA technique (SEA 기법을 이용한 저중량 대시판넬 흡,차음재 성능에 대한 연구)

  • Lim, Hyo-Suk;Park, Kwang-Seo;Kim, Young-Ho;Kim, In-Dong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.51-55
    • /
    • 2007
  • In this paper Statistical Energy Analysis has been considered to predict high frequency air borne interior noise. Dash panel Insulation is major part to reduce engine excitation noise. Transmission loss and absorption coefficient are considered to predict dash insulation performance. Transmission lose is derived from coupling loss factor and absorption coefficient is derived from internal damping loss factor. Material Biot properties were used to calculate each loss factors. Insulation geometry thickness distribution was hard to measure, so FeGate software was used to calculate thickness map from CAD drawing. Each predicted transmission losses between conventional insulation and light weight insulation were compared with SEA. Transmission loss measurement was performed to validate each prediction result, and it showed good correlation between prediction and measurement. Finally interior noise prediction was performed and result showed light weight insulation system can reduce 40% weight to keep similar performance with conventional insulation system, even though light weigh insulation system has lower sound transmission loss and higher absorption coefficient than conventional system.

  • PDF

A New Physical Layer Transmission Scheme for LPI and High Throughput in the Cooperative SC-FDMA System

  • Li, Yingshan;Wu, Chao;Sun, Dongyan;Xia, Junli;Ryu, Heung-Gyoon
    • Journal of Communications and Networks
    • /
    • v.15 no.5
    • /
    • pp.457-463
    • /
    • 2013
  • In recent days, cooperative diversity and communication security become important research issues for wireless communications. In this paper, to achieve low probability of interception (LPI) and high throughput in the cooperative single-carrier frequency division multiple access (SC-FDMA) system, a new physical layer transmission scheme is proposed, where a new encryption algorithm is applied and adaptive modulation is further considered based on channel state information (CSI). By doing so, neither relay node nor eavesdropper can intercept the information signals transmitted from user terminal (UT). Simulation results show above new physical layer transmission scheme brings in high transmission safety and secrecy rate. Furthermore, by applying adaptive modulation and coding (AMC) technique according to CSI, transmission throughput can be increased significantly. Additionally, low peak-to-average power ratio (PAPR) characteristic can still be remained due to the uniform distribution of random coefficients used for encryption algorithm.

System Phase Noise Spectrum of the Transmission and Receiving System for COMS Sensor Data (통신해양기상위성 센서 데이터 송수신 시스템의 시스템 위상 잡음 스펙트럼)

  • Kim, Young-Wan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.7
    • /
    • pp.1247-1253
    • /
    • 2007
  • The system phase noise spectrum distribution for COMS sensor data transmitter and receiver system was proposed in this paper. On the basis of the analyzed design parameter to reduce the phase noise effect in a receiver, the optimal system phase noise were proposed for raw, IRIT and HRIT data transmission that are sensor data, respectively. The proposed system phase noise provides the qualified transmission performance of sensor data and reduces the performance degradation due to phase noise generating in the transmission channel. Also the system phase noise spectrums are utilized in the design of frequency generation source for sensor data transmission and receiver system.

Design and Implementation of Audio Transmission System Based on AoIP (AoIP 기반 음향전송시스템의 설계 및 구현)

  • Kang, Min-Soo;Sung, Kil-Young;Park, Yeoun-Sik
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.8
    • /
    • pp.1415-1419
    • /
    • 2008
  • In this paper, we investigate various Audio Transmission Systems to implement Audio Transmission System based on AoIP of Internet transmission technology TCP/IP Network and we design and implement a Audio transmission system based on AoIP by adopting the most efficient one. The implemented system can be applied for various professional audio systems with large-scale audio distribution network as well as small-scale PA systems. Moreover, this can be applied in various fields which need audio transmission.