• Title/Summary/Keyword: transmission anode target tube

Search Result 4, Processing Time 0.018 seconds

Characteristics of the X-ray Fluorescence by the 40kV transmission anode x-ray tube (40kV용 투과양극형 x-ray tube에 의한 X-ray 형광 특성)

  • Kim, Sung-Soo;Kim, Do-Yun
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.3
    • /
    • pp.247-252
    • /
    • 2008
  • By using the transmission anode x-ray tube developed to apply to the hand-held XRF equipment, we carried out XRF experiment and evaluated the influences of the x-ray tube on XRF spectra. XRF data, which is measured using the W-target and Rh-target tube, were good agreements with the known results. FWHM of Fe $K_{\alpha}$-line measured by W-target tube with the 35 kV-tube voltage and the $40{\mu}A$-tube current was 180 eV. This result reveals that our XRF equipment using the transmission anode x-ray tube is enough for a qualitative analysis of materials. By comparison XRF data with the integrated intensity of x-ray tube, it was confirmed that Rh-target tube is better than W-target tube for application to the hand-held XRF equipment.

Development and Characteristics of the x-ray transmission anode tube for the thickness measurement of film (필름 두께 측정용 투과 양극형 x-ray tube의 개발 및 특성)

  • Kim, Sung-Soo;Kim, Do-Yun
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.3
    • /
    • pp.240-246
    • /
    • 2008
  • The x-ray transmission anode Ag-target tube was developed to apply for the thickness measurement of film in the thickness range of several tens$\sim$several hundreds ${\mu}m$ and its characteristics were evaluated. The energy distribution and dose of x-ray from Ag-target tube was investigated at the tube voltage near 10 kV, and discussed in comparition with that from W-target tube. The energy distribution and dose of x-rays passing through film were measured with various thickness of Ny and PP film. From these results, it was confirmed that our x-ray tube can be applied for the thickness measurement of film.

Development and its Characteristics of the 40kV x-ray transmission anode target tube (40kV용 투과 양극형 x-ray tube의 개발 및 특성분석)

  • Kim, Sung-Soo;Kim, Do-Yun
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.3
    • /
    • pp.234-239
    • /
    • 2008
  • Tungsten and rhodium target tube for a 40 kV x-ray transmission anode was developed to apply to the hand-held XRF(X-Ray Fluorescence) apparatus and its characteristics were evaluated. From the measurement of the energy distribution and dose of x-ray, it was confirmed that our results were good agreements with the known ones. The optimum thickness of metal film deposited on Be window to extract the maximum dose were $2.6{\mu}m$ and $2.7{\mu}m$ in case of W-target tube and Rh-target tube, respectively. When it was continuously worked during 30 min. at 40 kV in tube voltage and at $60{\mu}A$ in tube current, the temperature at target did not exceed $50^{\circ}C$. Our results reveals that the 40 kV x-ray transmission anode tube can be applied to the hand-held XRF apparatus.

Quasi-monochromatic Parallel Radiography Achieved with a Polycapillary Plate

  • Sato, Eiichi;Komatsu, Makoto;Hayasi, Yasuomi;Tanaka, Etsuro;Mori, Hidezo;Kawai, Toshiaki;Ichimaru, Toshio;Takayama, Kazuyoshi;Ido, Hideaki
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.418-421
    • /
    • 2002
  • Fundamental study on quasi-monochromatic parallel radiography using a polycapillary plate and a plane-focus x-ray tube is described. The x-ray generator consists of a negative high-voltage power supply, a filament (hot cathode) power supply, and an x-ray tube. The negative high-voltage is applied to the cathode electrode, and the transmission type target (anode) is connected to the ground potential. The maximum voltage and current of the power supply were -100 kV (peak value) and 3.0 mA, respectively. In this experiment, the tube voltage was regulated from 20 to 25 kV, and the tube current was regulated by the filament temperature and ranged from 1.0 to 3.0 mA. The exposure time is controlled in order to obtain optimum film density, and the focal spot diameter was about 10 mm. The polycapillary plate is J5022-21 made by Hamamatsu Photonics Inc., and the outside and effective diameters are 87 and 77 mm, respectively. The thickness and the hole diameter of the polycapillary are 1.0 mm and 25 ${\mu}$m, respectively. The x-rays from the tube are formed into parallel beam by the polycapillary, and the radiogram is taken using an industrial x-ray film of Fuji IX 100 without using a screen. In the measurement of image resolution, we employed three brass spacers of 2, 30, and 60 mm in height. By the test chart, the resolution fell according to increases in the spacer height without using a polycapillary. In contrast, the resolution slightly fell with corresponding increases in the height by the polycapillary. In angiography, fine blood vessels of about 100 ${\mu}$m are clearly visible.

  • PDF