• Title/Summary/Keyword: transmission analysis

Search Result 5,831, Processing Time 0.032 seconds

A Study on Temperature and Tensile Load Analysis of Invar by Flame Exposure on Overhead Transmission Lines (화염노출에 의한 송전선로 인바 강심의 온도 및 인장하중 분석에 관한 연구)

  • Shin, Koo-Yong;Jung, Chae-Kyun;Lee, Sang-Yun;Kang, Ji-Won;Lee, Dong-Il
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.10
    • /
    • pp.1895-1901
    • /
    • 2009
  • This paper describes the conductor temperature and tensile load analysis of invar by flame exposure on STACIR(Super Thermal-resistance Aluminium-alloy Conductors Reinforced) overhead transmission line based on real fault phenomena. Firstly, short-circuit fault by flame exposure is analysed by EMTP/ATP simulation, then the cutting causes of Al layer are also discussed. And then, the conductor temperature is calculated based on IEC 60949 according to 3 kinds of materials including invar, Al conductor and ACSR when same load current respectively flows in 3 kinds of material, they are compared each other. Finally, the tensile load tests are performed with various samples including new invar, used invar for a long time and invar exposed flame.

Analysis of the Harmonic Resonance in Primary Restorative Transmission Systems Using EMTDC (EMTDC를 이용한 시송전계통의 고조파공진 분석)

  • Lee K.S.;Park S.M.;Song I.J.;Lee N.H.;Bai J.C.;Whang B.W.;Lee H.J.
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.4
    • /
    • pp.172-176
    • /
    • 2005
  • Power system restoration following a massive or complete blackout starts with energizing of primary restorative transmission lines. During this primary restoration, inexpected overvoltage may happen due to nonlinear interaction between the unloaded transformer and the transmission system. This is known as the harmonic resonance phenomenon that may cause burning out of transformer or other devices. By now the harmonic resonance is reported in the extra high voltage system. This paper reports the detection of the resonance in Korean power system. Basic analysis and simulation of the harmonic overvoltage is presented using EMTDC.

Probabilistic Reliability Evaluation of Power System using TRELSS II - Focused on Case Studies of IEEE RTS - (TRELSS를 이용한 전력계통의 확률론적 신뢰도 평가 II - IEEE RTS 사례연구를 중심으로 -)

  • Tran, Tungtinh;Kang, Sung-Rok;Choi, Jae-Sok;Jeon, Dong-Hoon;Choo, Jin-Boo
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.67-70
    • /
    • 2003
  • In recent, the importance and necessity of some studies on reliability evaluation of grid come from the recent black-out accidents occurred in the world. The quantity evaluation of transmission system reliability is very important under competitive electricity environment. The reason is that the successful operation of electric power under the deregulated electricity market depends on transmission system reliability management. The various results of many case studies for the IEEE 25buses system using the Transmission Reliability Evaluation for Large-Scale Systems(TRELSS) Version 5_1, a program made in EPRI are introduced in this paper. Some sensitivity analysis has been included. This paper suggests that the some important input parameters of the TRELSS can be determined optimally from this sensitivity analysis for high reliability level operation of a system.

  • PDF

Transmission Electron Microscopy Specimen Preparation for Layer-area Graphene by a Direct Transfer Method

  • Cho, Youngji;Yang, Jun-Mo;Lam, Do Van;Lee, Seung-Mo;Kim, Jae-Hyun;Han, Kwan-Young;Chang, Jiho
    • Applied Microscopy
    • /
    • v.44 no.4
    • /
    • pp.133-137
    • /
    • 2014
  • We suggest a facile transmission electron microscopy (TEM) specimen preparation method for the direct (polymer-free) transfer of layer-area graphene from Cu substrates to a TEM grid. The standard (polymer-based) method and direct transfer method were by TEM, high-resolution TEM, and energy dispersive X-ray spectroscopy (EDS). The folds and crystalline particles were formed in a graphene specimen by the standard method, while the graphene specimen by the direct method with a new etchant solution exhibited clean and full coverage of the graphene surface, which reduced several wet chemical steps and accompanying mechanical stresses and avoided formation of the oxide metal.

A Contactless Power Conversion System Use a Slinder Ferrite Core (실린더 페라이트 코어를 사용한 무접점 전력 변환 시스템)

  • Lee Seng-Jun;Wooe Ohn Jae
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.638-641
    • /
    • 2001
  • Connectorless power transmission and supply are the power transfer device revealed by resonant inverter or transformer using inductant device. Recently, on power supply have been going on frequently, so several power supply circuit forms are announced. But Compared with the circuit of previous paper, instead of the circuit composed of a simple sylinder Ferrit, I was manufacture in a sylinder that It was a double overlab to a sylinder and I was followed a double flux in inner flux path. Above all, for practicalization, supply circuit operation character analysis and development of controller should be preceded. According to this paper, power transmission and supply analyze characters and design control circuit like the analysis of general resonant inverter for power transmission. They compose the circuit to get sinusoid wave output voltage using pulse width modulation control mode. For Supply, output wave form through power track and power pick-up of magnetic inductance includes ripper component. So I intend to design the controller including filter and regulator, compare analyze theoretical result with real measurement value and then show you their practicality

  • PDF

An efficient Channel Estimation Technique of OFDM-Base Space-Time Coded Wireless LAN Systems

  • Kim, Dong-Ok
    • Journal of information and communication convergence engineering
    • /
    • v.2 no.2
    • /
    • pp.61-66
    • /
    • 2004
  • This paper presents a way to maximize transmission efficiency and reception ability through transmission diversity technology, which can be adapted to wireless multimedia Wireless LAN system. The presented method is a comparative analysis between a case where parameter a for time average is 0.3.1 with consideration of channel presumption with two types of rms delayed spread, which is 50nsec. 150nsec, for the performance analysis of STTC (Space-Time Trellis Code) adopting time-space ciphering method appropriate for MIMO channel, and performance in the case where presumed channel value from long training column section is applied to according frame in a single frame. The result showed that BER brought SNR improvement of l.0dB in $10^{-3}$ when a was 0.3 than adopting only the long training column, and showed increase of general performance improvement for the sake of time average rather than the case without.

Design of Long Span Overhead Transmission Line using Special High-tension Wire (특수 고장력전선을 사용한 장경간 가공송전선로 설계)

  • Na, Sang-Yong;Ji, Pyeong-Shik
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.65 no.3
    • /
    • pp.183-187
    • /
    • 2016
  • Recently, power demand has been increasing every year according to variation of electrical equipments and temperature rise in summer season. So, much more overhead line is being demanded to copy with increasing power demand and operate reliable power system. This paper analysis the characteristics of long span overhead transmission line using special high-tension wire in such as a safety factor, coefficient of elasticity, and the coefficient of linear expansion. Based on the analysis, we proposed the effectiveness of special high-tension wire having much more advantages with respect to height of steel tower and dip compared with conventional ACSR in long span overhead transmission line.

A Criterion using Statistical Analysis for Transmission Line outages and Weather (송전선로 고장실적과 날씨의 통계분석을 통한 날씨기준 설정)

  • Lee, Seung-Hyuk;Shin, Dong-Suk;Kim, Jin-O;Jeon, Dong-Hoon;Choo, Jin-Bu
    • Proceedings of the KIEE Conference
    • /
    • 2004.11b
    • /
    • pp.60-62
    • /
    • 2004
  • Transmission line outage is influenced by several weather factors: wind, rain snow, temperature, cloud and humidity. And most power system reliability studies assume a failure rate. It can be calculated by transmission line outage data and weather data. Also weather is divided into normal weather and adverse weather by failure rate analysis. The effect of failure rate is discussed with both normal weather and adverse weather. It can be used in effective information about system operation and planing.

  • PDF

Dynamic Response of Pneumatic Transmission Lines (공압 전달관의 동적 응답)

  • 박현우;박종호;신필권;심우건
    • Journal of KSNVE
    • /
    • v.9 no.2
    • /
    • pp.285-294
    • /
    • 1999
  • Transient analysis for compressible fluid flow has been performed experimentally and analytically to study the dynamic characteristics of the end volume transmission lines following a sudden pressure change a its entrance. The numerical method was developed based on the method of characteristics. The sudden pressure at its entrance was generated by rupture of diaphragm in a shock tube. The sudden pressure was used to obtain the response, as input signal for the numerical analysis. The response to the sudden pressure at the end volume was measured using a pressure transducer. The experimental result shows good agreements with the numerical result. The effects of tube length, its diameter and end volume magnitude are evaluated on the responses of the pressure and on the damping factor. It is found that the viscous damping effects on the response through the transmission pipeline becomes larger with increasing pi;eline length and decreasing diameter of the pipe and the fluid-elastic stiffness decreases with increasing the terminal volume. The numerical approach presented in this paper can be very useful in designing the instrument and control system.

  • PDF

Development Study on the Power System Analysis in Myanmar (해외 송변전 사업 추진사례(미얀마 전력망 진단 및 분석))

  • Mun B. S.;Bang M. J.;Choi H. J.;Kim J. H.;Kim S. H.;Choi Y. S.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.51-53
    • /
    • 2004
  • KEPCO is now promoting the overseas transmission businesses on the basis of competitive transmission technology. This paper deals with a development study on the power system network analysis in Myanmar which was performed as the first overseas transmission business of KEPCO. The aim of this study is to establish comprehensive and stable power system network plan by analyzing the current and future system in Myanmar.

  • PDF