• Title/Summary/Keyword: transmission analysis

Search Result 5,831, Processing Time 0.029 seconds

A Development of the Noise Quality Checking System EOL of the 6th Speed Automatic Transmission in the USA (북미 6속 자동변속기 공장 EOL NVH 시스템 개발에 대한 연구)

  • Lee, Hyun-Ku;Kim, Moo-Suk;Hwang, Seon-Yang;Kang, Koo-Tae;Lee, Tae-Hwi
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.731-732
    • /
    • 2011
  • This paper shows a whole noise quality checking system for the new developed 6th speed automatic transmission manufactured in USA. Due to demand for manufacturing of the high NVH quality transmissions in the mass product line, some special checking system called EOL is adapted. This EOL system is using vibration analysis technologies. Through adapting vibration analysis technologies and functions likewise RMS, Crest Factor, Harmonics, Peak, Band, and Order tracking, various noise problems caused by wear, nick, and deformations could be successfully detected and predicted. Therefore, automatic transmissions manufactured in the USA could get high NVH quality.

  • PDF

The evaluation of vibration contribution about the eccentric rotor system by multiple dimensional spectral analysis (다차원 해석법을 이용한 편심 회전체의 전달 기여도 평가)

  • 조문갑;조용구;김동원;이정윤;오재응
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.298-303
    • /
    • 2003
  • The eccentric rotor system has various problems by vibration of unbalance mass. Specially, it is difficult to analyze vibration problem for the drum washing machine due to correlation of transmission paths. We analyze the mechanical structure by multidimensional spectral density to identify the maximum vibration magnitude at the frequency domain. It estimates the coherence function of the signals to pass the transmission paths. In case of the drum washing machine, because the transmission paths are correlated partially it needs to determinate the priority ranking. And the correlated parts are eliminated using conditioned spectral density function. Finally the shielding effect method confirms the reasonability of the modeling.

  • PDF

Electro-magnetic Field Analysis of 2-Layer HTS Power Transmission Cable Core (2층 고온초전도 전력케이블 코어의 전자장 해석)

  • 조전욱;주진홍;김석환;배준한;김해종;김해준;성기철;홍정표
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.02a
    • /
    • pp.269-271
    • /
    • 2003
  • A typical HTS power transmission cable has multi-layer conductor structure to increase the current capacity. The tapes of the innermost layer are wound on a round former, and adjacent tapes of another layer are separated by a thin insulating film. In steady state, the total current flows in the conductor layer, and consequently there is magnetic field between the inner and outer layer. This paper describes a magnetic field amplitude around the conductor layer and the HTS tape by a transport current. Also, this paper will help for future cable conductor prototypes.

  • PDF

Performance of SC-FDE System in UWB Communications with Imperfect Channel Estimation

  • Wang, Yue;Dong, Xiaodai
    • Journal of Communications and Networks
    • /
    • v.9 no.4
    • /
    • pp.466-472
    • /
    • 2007
  • Single carrier block transmission with frequency domain equalization(SC-FDE) has been shown to be a promising candidate in ultra-wideband(UWB) communications. In this paper, we analyze the performance of SC-FDE over UWB communications with channel estimation error. The probability density functions of the frequency domain minimum mean-squared error(MMSE) equalizer taps are derived in closed form. The error probabilities of single carrier block transmission with frequency domain MMSE equalization under imperfect channel estimation are presented and evaluated numerically. Compared with the simulation results, our semi-analytical analysis yields fairly accurate bit error rate performance, thus validating the use of the Gaussian approximation method in the performance analysis of the SC-FDE system with channel estimation error.

Overvoltage Analysis and Air Clearance Design of 345kV/154kV Transmission Tower (345kV/154kV 계통 과전압 해석과 공기절연간격 산정)

  • Shim, E.B.;Woo, J.W.;Kwak, J.S.;Yoon, S.H.;Kim, K.H.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.449-451
    • /
    • 2001
  • This paper described the switching overvoltage analysis on the 345kV and 154kV transmission system by EMTP(Electromagnetic transient Program) for the enactment of current insulation design standards of KEPCO. The air clearance design of current transmission tower was reviewed and revised by the calculated result, considering swing angle for the each type of insulator string by the wind velocity.

  • PDF

A Study on the Radiation Characteristics of Noise from HV AC Transmission Lines Using a Gap Noise Generator (인공잡음 발생장치를 이용한 초고압 시험선로의 잡음 방사특성 연구)

  • Shin, K.Y.;Lee, D.I.;Kim, S.B.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2041-2043
    • /
    • 1999
  • In order to investigate the radiation characteristics of unmixed line noise from overhead high voltage AC transmission lines, a gap noise generator was manufactured. Disk size which decides capacitance between the noise generator and earth was selected through preliminary indoor experiments and analysis by charge simulation method. The capacitance is one of principal parameters related to inject a proper noise current into lines. The field experiments were performed with the noise generator installed in Kochang 765 kV full scale test line. As the results, the useful data which can be used to analysis the radiation characteristics of noise from transmission lines was obtained. Those are lateral profiles the directivity of antenna toward lines, frequency spectra and so on.

  • PDF

A analysis result on the application of HSGS to the 765 kV transmission line according to it's length (765 kV 계통의 송전선로 거리에 따른 HSGS 적용에 관한 연구)

  • Woo, J.W.;Shim, E.B.;Kim, J.H.;Kim, B.J.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2069-2072
    • /
    • 1999
  • The extended 765 kV system may have severe electrical transients according to the interconnection of transmission lines and have long transmission line over 250 km. So we need to analyze the transient phenomena to confirm the insulation coordination which is designed for 765 kV project step I. In particular, this paper shows the analysis results of secondary arc extinction by HSGS (high speed ground switch) application. The EMTP/MODELS were used to simulation study of secondary arc phenomena. We had confirmed the TRV(transient recovery voltage) and rated current of HSGS which will be used in the KEPCO 765 kV system.

  • PDF

A Simulation of Lightning Faults Reducing Effects on the 154 kV Transmission Tower by Auxiliary Grounding (보조접지선 시공에 의한 송전선로의 내뢰성 향상효과 모의)

  • Kwak, Joo-Sik;Shim, Jeong-Woon;Shim, Eung-Bo;Choi, Jong-Gi
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1843-1846
    • /
    • 1997
  • This paper describes the fault reducing effects of the 154 kV transmission tower by auxiliary grounding from the top of the tower to ground. The grounding surge impedance of the auxiliary grounding system is calculated by CDEGS(:Current Distribution Electromagnetic Interference Grounding and Soil Structure Analysis), and the critical lightning back flashover current and arcing horn dynamic characteristics are simulated by EMTP/TACS(:Electromagnetic Transient Program/Transient Analysis of Control Systems). The calculated results of total LFOR(Lightning Flashover Rate) shows that the LFOR can be reduced from 5.2(count/100km. year) to 3.4 by auxiliary grounding on the 154 kV transmission tower with one ground wire shielding system.

  • PDF

Axial Stiffness Analysis of a Clutch Diaphragm Spring in Passenger Cars (승용차용 클러치 다이아프램 스프링의 축방향 강성해석)

  • Kim, J.Y.;Kim, J.G.;Yoon, H.J.
    • Journal of Power System Engineering
    • /
    • v.14 no.6
    • /
    • pp.35-40
    • /
    • 2010
  • This article deals with the numerical analysis results of stiffness of diaphragm spring used in the clutch of a manual transmission. In order to investigate the relationship of the force and displacement in a diaphragm spring, we have established a numerical model of diaphragm spring using a well-known analytic model of Belleville spring and a cantilever beam model for the finger part of diaphragm spring. Using the stress and strain relations of Belleville spring and cantilever beam, we propose the analytic equation of motion of diaphragm spring for the use of a clutch automated actuator in an automated manual transmission. The proposed analytic model represents the typical dynamic characteristics of diaphragm spring along with the release bearing travel. And it is characterized in a closed-form equation, therefore it can be used for the further study of development of actuator and control law of clutch automating mechanism.

Feasibility Study of Multi-regional Transmission Main Stabilization for Sustainable Water Supply (수돗물 공급 안정화를 위한 광역상수도 관로 안정화 타당성 연구)

  • Lee, Jae Bum;Yi, Choong Sung;Jung, Kwan Sue
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.3
    • /
    • pp.395-404
    • /
    • 2013
  • The risk of pipe-bursting in multi-regional transmission mains consisting of 89 % of singled pipeline is so high that pipeline stabilization project is required such as renewal and replacement, pipe paralleling, emergency ties. Pipeline stabilization projects could be postponed at the step of initial decision-making because effect of this project is intangible benefit like activation of economic, improvement of welfare related to water. This study is to suggest quantified economical feasibility model for intangible benefit presumption to solve above problem. Cost reduction of emergency water supply, leakage, burst restore and energy efficiency improvement was altered and applied. As a result of economic analysis taking into account estimated benefit and cost under discount rate 5.5 %, service life 40 years, sufficient economic feasibility analyzed with B/C 2.45, NPV 317,700 million won, IRR 9.09 %.