• Title/Summary/Keyword: transient information

Search Result 715, Processing Time 0.025 seconds

Development of a Reclosing Scheme for Reduction of Turbine Generator Shaft Torsional Torques: A Decision Method to Achieve Optimal Reactor Capacity

  • Oh, Yun-Sik;Seo, Hun-Chul;Yang, Jeong-Jae;Kim, Chul-Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.4
    • /
    • pp.1145-1153
    • /
    • 2014
  • It is well known that line switching operations like reclosing are able to cause transient power oscillations which can stress or damage turbine generators. This paper presents a reclosing scheme to reduce the shaft torsional torques of turbine generators by inserting an additional reactor. A novel method to determine optimal reactor capacity to minimize the torsional torque generated in a turbine generator is also proposed. In this paper, the turbine generator shaft is represented by a multi-mass model to measure torsional torques generated in the shaft between the turbine and the generator. Transmission systems based on actual data from Korea are modeled to verify the proposed scheme using ElectroMagnetic Transient Program (EMTP) software. The simulation results clearly show the effectiveness of the proposed scheme and torsional torque can be minimized by applying the proposed scheme.

Comparative Study of the System Operational Method for Fault-Tolernace (Fault-Tolerance를 위한 시스템의 동작방식에 대한 비교 연구)

  • 양성현;이기서
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.17 no.11
    • /
    • pp.1279-1289
    • /
    • 1992
  • Fault-tolerant system in improved the reliability and safety by using hardware and software redundancy. Fault mask and detection, identification techniques are conditionally used with system's application areas. Here DMR system is operated with standby and fail-safe module method that has minimal hardware and software redundancy, then its reliablity and safety comparison is presented respectively. Also this paper proposed an effective methods of dealing with transient faults as compared system's MTTFs to transient faults tolerance capabilities of self-diagnosis program.

  • PDF

Critical Conduction Mode Bridgeless PFC Converter Based on a Digital Control (디지털 제어 기반의 경계점모드 브릿지리스 PFC 컨버터)

  • Kim, Tae-Hun;Lee, Woo-Cheol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.12
    • /
    • pp.2000-2007
    • /
    • 2016
  • Generally, in order to implement the CRM(Critical Conduction Mode), the analog controller is used rather than a digital controller because the control is simple and uses less power. However, according to the semiconductor technology development and various user needs, digital control system based on a DSP is on the rise. Therefore, in this paper, the CRM bridgeless PFC converter based on a digital control is proposed. It is necessary to detect the inductor current when it reaches zero and peak value, for calculating the on time and off time by using the current information. However, in this paper, the on-time and off-time are calculated by using the proposed algorithm without any current information. If the switching-times are calculated through the steady-state analysis of the converter, they do not reflect transient status such as starting-up. Therefore, the calculated frequency is out of range, and the transient current is generated. In order to solve these problems, limitation method of the on-time and off-time is used, and the limitation values are varied according to the voltage reference. In addition, in steady state, depending on the switching frequency, the inductance is varied because of the resonance between the inductor and the parasitic capacitance of the switching elements. In order to solve the problem, inductance are measured depending on the switching frequency. The measured inductance are used to calculate the switching time for preventing the transient current. Simulation and experimental results are presented to verify the proposed method.

Color Transient Improvement Algorithm Based on Image Fusion Technique (영상 융합 기술을 이용한 색 번짐 개선 방법)

  • Chang, Joon-Young;Kang, Moon-Gi
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.45 no.4
    • /
    • pp.50-58
    • /
    • 2008
  • In this paper, we propose a color transient improvement (CTI) algorithm based on image fusion to improve the color transient in the television(TV) receiver or in the MPEG decoder. Video image signals are composed of one luminance and two chrominance components, and the chrominance signals have been more band-limited than the luminance signals since the human eyes usually cannot perceive changes in chrominance over small areas. However, nowadays, as the advanced media like high-definition TV(HDTV) is developed, the blurring of color is perceived visually and affects the image quality. The proposed CTI method improves the transient of chrominance signals by exploiting the high-frequency information of the luminance signal. The high-frequency component extracted from the luminance signal is modified by spatially adaptive weights and added to the input chrominance signals. The spatially adaptive weight is estimated to minimize the ${\iota}_2-norm$ of the error between the original and the estimated chrominance signals in a local window. Experimental results with various test images show that the proposed algorithm produces steep and natural color edge transition and the proposed method outperforms conventional algorithms in terms of both visual and numerical criteria.

A Study on Effectively Building Public Safety Network for Provision of Narrowband and Broadband PPDR Services (협대역 및 광대역 PPDR 서비스 제공을 위한 재난통신망의 효율적인 구축 방안 연구)

  • Park, Seong-Gyoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.8
    • /
    • pp.860-872
    • /
    • 2013
  • In this paper, reasonable and effective building strategies of PPDR network is presented through investigating and analysing current policies for PPDR network of Korea and foreign countries. The research result shows that it is necessary PPDR network is designed and implemented considering currently transient status in aspects of PPDR-related technical roadmaps and existing PPDR networks. Also, in the transient period of more than 5 years, mobile broadband- based private PPDR network should be builded and it should be complemented by some commercial networks such as TRS or other mobile broadband networks.

Analysis of Transient Characteristics for Distributed Generations with the Secondary Feeders (저압배전선로에 연계된 분산전원의 과도특성 해석에 관한 연구)

  • Yoon, Gi-Gab;Rho, Dae-Seok;Kim, Eui-Hwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.10
    • /
    • pp.3898-3904
    • /
    • 2010
  • In order to analyze the transient characteristics for distributed generation located with the secondary feeders, this paper constructs a Distributed Generations Filed Test Center which can produce transient characteristics such as voltage sag, swell, interruption, harmonic and so on. And also this paper proposes the test results for the interconnection of distributed generations. The results show the effectiveness for the utility technical guidelines for distributed generations with the secondary feeders.

Features of Transient Overvoltages Observed at 22.9kV Consumer's Substation (22.9kV 수전설비에서 측정된 과도과전압의 특성)

  • Shim, Hae-Sup;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.9
    • /
    • pp.52-59
    • /
    • 2014
  • The aims of this paper are to characterize the transient overvoltages(TOVs) and to evaluate the risk occurring at 22.9kV consumer's substation. The measurements of lightning- and switching-caused TOVs were made during Mar. 2013 and Feb. 2014. As a consequence, 47 events of TOVs were recorded and 4 of them were higher than the input voltage envelope(IVE) of the information technology industry council(ITI) curve. The measured TOVs are characterized by longer front times and longer durations compared to the $1.2/50{\mu}s$ standard impulse voltage waveform, and some of them represent bipolar waves with lower oscillation frequencies. It suggests that the test of non-standard impulse voltage waveforms is needed for effective risk assessments of power apparatus. Lightning- and switching-caused TOVs exceeding IVE of ITI curve are induced at the secondary of 22.9kV potential transformer(PT). We may, therefore, conclude that the surge protection devices should be applied at the secondary of PT and the surge absorbers should be installed at the primary of VCB or PT. The results presented in this paper could be useful to design the reasonable insulation coordination for 22.9kV consumer's substation.

Three-dimensional Modeling of Transient Enhanced Diffusion (과도 증속 확산(TED)의 3차원 모델링)

  • 이제희;원태영
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.35D no.6
    • /
    • pp.37-45
    • /
    • 1998
  • In this paper, we report the first three-dimensional simulation result of the transient enhanced diffusion(TED) of dopants in the ion-implanted silicon by employing our 3D semiconductor process simulator, INPROS system. In order to simulate three-dimensional TED redistribution of dopants in silicon, the dopant distributions after the ion implantation was calculated by Monte Carlo(MC) method, followed by finite element(FE) numerical solver for thermal annealing. Excellent agreement between the simulated 3D profile and the SIMS data has been obtained for ion-implanted arsenic and phosphorus after annealing the boron marker layer at 75$0^{\circ}C$ for 2 hours. Our three-dimensional TED simulation could successfully explain the reverse short channel effect(RSCE) by taking the 3D point defect distribution into account. A coupled TED simulation and device simulation allows reverse short channel effect on threshold to be accurately predicted.

  • PDF

Unconditionally Stable Analysis of Transient Scattering from Conductors Using Time-Domain Combined Field Integral Equations (시간영역 결합적분식을 이용한 도체 과도산란의 무조건 안정된 해석)

  • 정백호;서정훈;이원우
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.40 no.8
    • /
    • pp.340-348
    • /
    • 2003
  • In this paper, we propose a novel formulation to solve a time-domain combined field integral equation (CFIE) for analyzing the transient electromagnetic scattering response from closed conducting bodies. Instead of the conventional marching-on in time (MOT) technique, tile solution method in this paper is based on the moment method that involves separate spatial and temporal testing procedures. Triangular patch vector functions are used for spatial expansion and testing functions for three-dimensional arbitrarily shaped closed structures. The time-domain unknown coefficient is approximated as a basis function set that is derived from tile Laguerre functions with exponentially decaying functions. These basis functions are also used as the temporal testing. Numerical results computed by the proposed method arc stable without late-time oscillations and agree well with the frequency-domain CFIE solutions.