• 제목/요약/키워드: transient improvement

검색결과 323건 처리시간 0.035초

Fe기 MA956 산화물분산강화합금의 천이액상확산접합에 관한 연구 (Transient-Liquid-Phase Bonding of Fe-Base MA956 ODS Alloy)

  • 강지훈
    • 한국분말재료학회지
    • /
    • 제2권1호
    • /
    • pp.53-62
    • /
    • 1995
  • TLP(Transient-Liquid-Phase) bonding of Fe-base MA956 ODS alloy was performed. As insert metal a commercially available Ni-base alloy(MBF50) and an MA956 alloy with additive elements of 7wt% Si and 1wt% B were used. To confirm the idea that a concurrent use of MA956 powder with Insert metals can enhance the homogenization of constituent elements and thereby reduce the thickness of joint interface, MA956 powder was also inserted In a form of sheet. SEM observation and EDS analysis revealed that Cr-rich phase was formed in the bonded interface in initial stage of isothermal solidification during the bonding process, irrespective of kind of insert metals. Measurement of hardeness in the region of bonded interface and EDS analysis showed that a complete homogenization of composition could not be obtained especially in case of MBF50. Joints using either BSi insert metals only or BSi insert together with MA956 powder interlayer showed, however, a remarkable improvement in a compositional homogenization, even though a rapid grain growth in the bonded interface could not be hindered.

  • PDF

정수장 응집설비의 효율증대 방안연구 (The Efficiency Improvement of Flocculation Facilities in Water Treatment Plants)

  • 전복수;이은웅;임수생;최재영;김홍권
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.952-954
    • /
    • 2000
  • In the cleaning-water treatment process, the flocculation machine is operated by the V.S motor when the coagulation-facility of the coagulation-process is operated. But after the flocculation machine is stopped by an instantaneous power failure, the transient takes place when the coagulation facility is re-started. To improve the transient state, we developed the reinforcement-circuit which had the function of soft-start and adapted to the field. As a result of this study, we reduced the damage of facilities and had the safety in maintaining the quality of water and improved the efficiency in the maintenance and the management.

  • PDF

지중열교환기 성능 향상에 관한 연구 (A Study on Improving the Efficiency of Ground Heat Exchanger)

  • 김욱중;이공훈;김민수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.3142-3147
    • /
    • 2008
  • A simple transient simulation of ground source heat pump system was carried out to investigate the effects of ground thermal conductivity on its performance. The TRNSYS code with a simple water to water heat pump model was used to compare the COP variation of the system. A new ground heat exchanger called by semi-closed loop was proposed and constructed in the real site. The effective thermal conductivity was measured using the test equipment developed by according to the line source model. The simulation results showed that highly efficient thermal conductivity of the grout material could increase the performance of the heat pump system very well. And the new ground heat exchanger showed the increased effective thermal conductivity as the penetration water flow rate(PWFR) was increased. Therefore, the performance improvement of the heat pump system using the proposed ground heat exchanger can be expected.

  • PDF

과도안정도 향상을 위한 직렬콘덴서의 최적화 방안 (An Optimization Method of Series Condenser for Improvement of Transient Stability)

  • 유석구;문병서;김규호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 B
    • /
    • pp.890-892
    • /
    • 1996
  • This paper presents a method for optimal placement of series condenser in order to improve the power system transient stability using genetic algorithms(GAs). In applying GAs, this approach utilizes two kinds of strings, one is coded by a binary finite-length for the selection of lines to install series condenser, the other is coded by a real value for the determination of injected condenser capacitance. For the formulation. this paper considers multi-objective function which is the critical energy as decelerating energy in power systems and the total injected condenser capacitance. The proposed method is applied to 9-bus, 18-line, 3-machine model system to show its effectiveness in determining the locations to install series condenser and the series condenser capacitance to be injected, simultaneously.

  • PDF

중성점 비접지 UPS시스템의 부동현상에대한 실험적 연구 (Experimental Study of The Floating-Phenomenon on Neutral Ungrounded UPS System)

  • 심해섭
    • 조명전기설비학회논문지
    • /
    • 제25권5호
    • /
    • pp.67-72
    • /
    • 2011
  • In this study we investigate the background of UPS output transformer(${\Delta}-Y$) operation on neutral ungrounded system, and perform field experiment of neutral floating-phenomenon for the inter-locked securing of electric facilities and improvement of neutral floating-phenomenon. Experiment results show that a floating-phenomenon occurs when four-pole input-breaker trip and the neutral to earth voltage occurring concurrently is identified as phantom voltage. And the measures for the transient overvoltage that can occur in floating-state also are investigated. As a result, the risk elements of neutral ungrounded method as well as neutral floating-phenomenon are removed by installation of separate solidly-grounded transformer and switching four-pole input-breaker to three-pole input breaker.

Average 기법에 의한 Visual-TEP의 검출과 DC-Drift 제거에 의한 TEP 신호개선에 관한 연구 (Studies on the Detection of Visual-TEP with Average Method & the Improvement of TEP with DC-Drift Elinination)

  • 배병훈;최정미
    • 대한의용생체공학회:의공학회지
    • /
    • 제15권2호
    • /
    • pp.135-142
    • /
    • 1994
  • This paper presents average method to detect Visual-Transient Evoked Potential from the human scalp electric potential measured by the ElectroEncephaloGram. To confirm the validity of average method, the average-process is performed with both stimulated and no-stimulated potentials respectively, and both results are compared. The specific waveform, which is visual-transient evoked potential, is produced only in the case of stimulated potential. It was found that a dc-drift, due to instrumentation errors and other noises, can produce significant changes in the evoked-potential waveform. This can be removed with a high-pass filter (cut-off frequency=0.5Hz).

  • PDF

후면 덧쌓기에 따른 농업용 저수지 제체의 안정성 평가 (Safety evaluation of agricultural reservoir embankment according to backside extension)

  • 이달원;노재진
    • 농업과학연구
    • /
    • 제39권1호
    • /
    • pp.97-110
    • /
    • 2012
  • This study was carried out for safety evaluation, the practical application and improvement of design method of the agricultural reservoir embankment according to backside extension. Seepage analysis, slope stability analysis and finite element analysis were performed for steady state and transient conditions. Also, the pore water pressure, seepage quantity, safety factor and stress-strain behavior according to high water level and rapid drawdown were compared and analyzed. The pore water pressure at contact region between backside extension and old embankment was kept high after rapid drawdown. Therefore, backside extension is recommended that design method is required to be improved and reinforced more than the others raising embankment. The hydraulic gradients before and after backside extension showed high value at the base of the core, but they showed stable state at the upstream slope and downstream slope. The seepage quantity per 1 day and the leakage per 100 m for the steady state and transient conditions appeared to be safe against the piping. The safety factor of slope stability showed high at the steady state, and transient conditions did not show differences depending on the rapid drawdown. The safety factor was appeared high at the upstream slope before backside extension and downstream slope after extension. The excess pore water pressure for steady state and transient conditions showed negative(-) at the upstream slope, it was small at the downstream slope. The mean effective stress (p') showed high at the base of the core and to be wild distribution after the extension. The displacement after extension showed 0.02-0.06 m in the upstream slope, the maximum shear strain after extension was smaller than that before extension.

내재적 유전자에 의한 어류난자에서의 hEGE 단백질 생산을 위한 기술개발 (Development of Transgenic Fish for the Production of Human EGF Protein)

  • 황창남;송기철;이재현;윤종만;김기동;이상호;박홍양
    • 한국가축번식학회지
    • /
    • 제25권3호
    • /
    • pp.277-286
    • /
    • 2001
  • 기존의 미세주입 및 정자 electroporation에 의한 보다 효율적인 유전자 도입방법을 개선하여 간단하고 고효율성의 유전자 변환기술을 위한 유전자 도입장치의 시제품 개발로 다수의 난자를 전기적으로 단순화할 수 있는 상업화의 가능성을 보여주었다. 도입된 유전자는 모든 초기배에서 발현됨을 보여 주었다. 특히 난황내의 합포체세포(syncytium)에서의 transient성의 강한 발현은 전기자극에 의해 많은 수의 난자에 유전자를 도입하고 100% 발현되는 체계를 이용하여 transient 시기에서 인간 유용단백질 생산의 가능성을 타진할 수 있는 결과를 보여 주었다. 어류유전자 발현의 작동되는가를 검색하기 위해 신경세로조직특이 tubulin promoter 를 이용한 결과 gfp의 발현이 뇌주변과 척추를 중심으로 체내 전반의 신경세포내에 발현이 강하게 나타남을 보여 주었다. 한편 reporter 유전자 이외에 간세포로부터 전체 RNA를 분리시켜 vitellogenin의 분해산물인 phosvitin cDNA의 길이와 promoter지역인 1.6 kb에 대한 primer쌍들을 선정한 상태에서 PCR에 의해 각각 cDNA와 gDNA로부터 cloning 중에 있으며 human factor Ⅶ과 epidermal growth factor, vitellogenin의 3종의 target 단백 질유전자를 구축 및 검정 화인 중에 있다.

  • PDF

임펄스전류에 의한 토양의 종류별 이온화 특성 (Ionization Behaviors in Various Soils Subjected to Impulse Currents)

  • 이복희;김회구;박건훈;백영환
    • 조명전기설비학회논문지
    • /
    • 제22권12호
    • /
    • pp.87-94
    • /
    • 2008
  • 이 논문은 뇌 임펄스전류에 의한 접지시스템의 과도적 특성에 관련된 토양의 이온화 현상과 파라미터를 기술하였다. 몇 가지 토양에서 발생하는 이온화 특성을 실험적으로 조사하였다. 절연파괴 임계전계강도와 이온화 반경을 용이하게 분석하기 위하여 원주형 실험기를 사용하였다. 전압과 전류 파형을 기초로 토양의 절연파괴 임계전계강도, 임피던스의 임펄스 전류 크기에 대한 의존성, V-I곡선과 과도임피던스를 검토하였다. 이온화 과정과 비선형 특성은 토양 종류에 매우 의존적이며, 포장용수량의 토양에서 2개의 전류피크는 나타나지 않았다. 본 연구 결과는 토양의 이온화를 고려하여 임펄스전류의 영향을 받는 접지시스템의 과도적 성능의 향상에 유용한 정보가 될 것이다.

육상전원공급장치(AMP) 이용한 선내 전원 공급 시 계통 안정도 분석 (Transient Stability Analysis of Vessel Power System Using Alternative Marine Power)

  • 강승표;김장목;조현준
    • 해양환경안전학회지
    • /
    • 제29권2호
    • /
    • pp.215-222
    • /
    • 2023
  • 세계적 선박 배출가스 저감에 대한 규제로 인해 항만 및 부두에서 육상전원공급장치(AMP, Alternative Marine Power)가 지속적으로 사용되고 있다. 국내 또한 항만 대기질 개선 특별법에 따라 AMP의 사용이 의무화되고 있고, 다양한 친환경선박과 연계하여 활용하도록 지속적인 시도를 하고 있다. 본 논문에서는 AMP를 통해 선내 전력을 공급하는 상황을 모델링 하여 AC Load Flow Analysis를 수행하였다. 이를 통해 선박에 전력이 공급될 때의 전기적 파라미터와 손실 등에 대해서 분석할 수 있다. 아울러 Transient Stability Analysis를 통해 계통의 사고 발생 시 선내 발전기를 통한 무정전전환에 대한 HSGT(High Speed Generation Transfer)의 한계값을 도출하고 이를 적용하였을 경우 결과에 대해 검토하였다.