• 제목/요약/키워드: transient flow

검색결과 1,138건 처리시간 0.031초

Transient Analysis of Self-Powered Energy-Harvesting using Bond-Graph

  • Makihara, Kanjuro;Shigeta, Daisuke;Fujita, Yoshiyuki;Yamamoto, Yuta
    • International Journal of Aerospace System Engineering
    • /
    • 제2권1호
    • /
    • pp.47-52
    • /
    • 2015
  • The transient phenomenon of self-powered energy-harvesting is assessed using a bond-graph method. The bond-graph is an energy-based approach to describing physical-dynamic systems. It shows power flow graphically, which helps us understand the behavior of complicated systems in simple terms. Because energy-harvesting involves conversion of power in mechanical form to the electrical one, the bond-graph is a good tool to analyze this power flow. Although the bond-graph method can be used to calculate the dynamics of combining mechanical and electrical systems simultaneously, it has not been used for harvesting analysis. We demonstrate the usability and versatility of bond-graph for not only steady analysis but also transient analysis of harvesting.

초음속 디퓨져 천이현상에 대한 수치적 연구 (Numerical study on the transient of supersonic diffuser)

  • 김종록
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2010년도 제34회 춘계학술대회논문집
    • /
    • pp.349-352
    • /
    • 2010
  • 초음속 디퓨져의 유동현상 및 천이구간에 대해서 수치적 기법에 의한 분석을 수행하였다. 수치기법으로는 초음속 디퓨져의 내부유동해석을 위하여 2차원 축대칭 Navier-Stokes equation와 $k-{\epsilon}$ 난류모델을 사용하였으며, 액체 로켓엔진의 연소실의 천이 구간의 압력변화에 따라서 디퓨져 내부의 마하수 및 진공 챔버의 온도분포를 비교 검토하였다.

  • PDF

원자로 냉각재 펌프의 과도 상태의 유동 및 열전달 해석 연구 (Flow and Heat Transfer Analysis of a Reactor Coolant Pump in Transient Conditions)

  • 허남건;김성원;유기풍;김승태
    • 한국유체기계학회 논문집
    • /
    • 제3권2호
    • /
    • pp.24-30
    • /
    • 2000
  • The structural analysis of a reactor coolant pump(RCP) of a nuclear power plant is very important for the safety assessment of the plant. Accurate boundary conditions for the heat transfer coefficient are required for reliable thermal stress analysis of the pump casing, especially in transient operations of the pump since the coolant properties are largely dependent on operational conditions. In the present study, a 3D mixed flow type coolant pump was modeled from the RCP drawings and analyzed in the steady state and number of transient flow conditions by using a commercial code STAR-CD. From the result of the computation, it is seen that the average heat transfer coefficients for the cases considered are found to be the suggested values of the manufacturer, Westinghouse Energy System. The unevenness in local heat transfer coefficients, however, is found to be considerable so that the use of average heat transfer coefficients in all boundaries might not give reliable thermal stress predictions.

  • PDF

과냉비등류에 있어서 동블록을 이용한 과도적 냉각실험 (Transient cooling experiments with a cooper block in a subcooled flow boiling system)

  • 정대인;김경근;김명환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제11권1호
    • /
    • pp.72-79
    • /
    • 1987
  • When the wall temperature is very high, a stable vapor film covers the heat transfer surface. The vapor film creates a strong thermal resistance when heat is transferred to the liquid though it. This phenomenon, called "film boiling" is very important in the heat treatment of metals, the design of cryogenic heat exchangers, and the emergency cooling of nuclear reactors. In the practical engineering problems of the transient cooling process of a high temperature wall, the wall temperature history, the variation of the heat transfer coefficients, and the wall superheat at the rewetting points, are the main areas of concern. These three areas are influenced in a complex fashion such factors as the initial wall temperature, the physical properties of both the wall and the coolant, the fluid temperature, and the flow state. Therefore many kinds of specialized experiments are necessary in the creation of precise thermal design. The object of this study is to investigate the heat transfer characteristics in the transient cooling process of a high temperature wall. The slow transient cooling experiment was carried out with a copper block of high thermal capacity. The block was 240 mm high and 79 mm O.D.. The coolant flowed throuogh the center of a 10 mm diameter channel in the copper block. In the copper block, three sheathed thermocouples were placed in a line perpendicular to the flow. These thermocouples were used to take measurements of the temperature histories of the copper block.

  • PDF

수평브릿지만법에 의한 갈륨비소 과도기 성장의 유한요소 해석 (Finite element analysis of transient growth of GaAs by horizontal Bridgman method)

  • 김도현;민병수
    • 한국결정성장학회지
    • /
    • 제6권1호
    • /
    • pp.19-31
    • /
    • 1996
  • 갈륨 비소 반도체 결정을 성장시키는 데 많이 사용되는 수평브렷지만법에 의하여 성장된 갈륨비소 단결정 내에셔 불순물 분포를 알아보기 위하여 액상에서 열전달, 물질전달, 유 체흐름과 고상에서 열전달을 묘사하는 과도기 모탤을 수립하였고 유한요소법과 음함수 척분법 에 의하여 수치모사를 행하였다. 그 결과 Gr이 작은 경우에는 확산조절성장의 특성을 보였으며 G Gr이 1,700 정도만 되어도 농도의 최소값이 계면 근처로 이동하였다. 응고가 진행됨에 따라 계 면의 곡률이 증가하였고, 흐름에 의한 혼합이 안정될 때까지 수직편석이 증가하였다. 수펑편석 은 응고가 진행됨에 따라 증가하였지만 흐름의 강도가 강한 경우에는 곧 일정하게 유지되였다. G Gr이 아주 작거나 큰 경우에는 Smith식과 Scheil식의 경우와 잘 일치하였다.

  • PDF

무용제 도료용 무화 분사시스템 개발(I) - 유압 엑츄에이터의 유동해석 - (Development of Atomization Spraying System for Solvent-free Paint(I) - Flow Analysis of Hydraulic Actuator -)

  • 김동건;김봉환;신선빈
    • 한국기계가공학회지
    • /
    • 제10권2호
    • /
    • pp.61-66
    • /
    • 2011
  • The purpose of this paper is to design a hydraulic actuator to operate under high pressure conditions. The flow characteristics under design conditions of hydraulic actuator were numerically conducted by commercial fluid dynamic code(ANSYS CFX V11). The numerical analysis was performed by transient technique according to the variation of stroke times, which was changed from 0 to 1 second by interval of 0.01. Turbulence model, $k-\omega$ SST was selected to secure more accurate prediction of hydraulic oil flow. The ICEM-CFD 11 and CFXMesher, reliable grid generation software was also adapted to secure high quality grid necessary for the reliable analysis. According to the simulation results, the flow rate which was supplied to the hydraulic actuator was 30.4l/min. These results are in good agreement with design results within 3.5% error.

준-비정상해석 기법을 통한 초음속 유동 내 무딘 물체의 열응답 예측 (Quasi-Transient Method for Thermal Response of Blunt Body in a Supersonic Flow)

  • 배형모;김지혁;배지열;정대윤;조형희
    • 한국전산구조공학회논문집
    • /
    • 제30권6호
    • /
    • pp.495-500
    • /
    • 2017
  • 본 논문에서는 과도한 계산용량이 필요한 초음속 비행체의 비정상 열응답 해석을 수행하기 위한 준-비정상해석 기법을 소개한다. 준-비정상해석 기법은 연성 연계 기법과 복합 열전달 해석기법을 통합한 방법으로 계산시간 단축시키면서 동시에 정확도를 향상시키기 위해 고안되었다. 또한 준-비정상해석 시, 해석 구간을 분할하기 위한 기준시간을 결정하는 알고리즘을 고안하여 준-비정상해석 기법의 정확도를 향상시키고자 하였다. 본 논문에서는 준-비정상해석 기법을 평가하기 위하여 가상의 비행 시나리오에서 열응답 해석을 수행하였으며, 비정상 해석 결과와 비교 검증을 수행하였다. 무딘 물체의 표면 온도 및 정체점의 온도를 통해 각각의 기법의 차이를 도출하였다. 비정상 해석을 통해 도출한 정체점의 온도와 준-비정상 해석을 통해 도출한 정체점의 온도 차이는 11.4% 이내로 높은 정확도를 확보함과 동시에 28배에 가까운 계산시간을 단축시켜 해석 기법의 효율성과 정확성을 확보하였다.

근접장착식 촉매장치의 유동분포 측정 및 해석에 관한 연구 (A Study of Measurement and Analysis of Flow Distribution in a Close-Coupled Catalytic Converter)

  • 조용석;김득상;주영철
    • 대한기계학회논문집B
    • /
    • 제25권4호
    • /
    • pp.533-539
    • /
    • 2001
  • In this study, results from an experimental and numerical study of flow distribution in a close-coupled catalytic converter (CCC) are presented. The experiments were carried out using a glow measurement system. Flow distribution at the exit of the first monolith in the CCC was measured using a pitot tube under steady and transient flow conditions. Numerical analysis was done using a CF D code at the same test conditions, and the results were compared with the experimental results. Experimental results showed that the uniformity index of exhaust gas velocity decreases as Reynolds number increases. Under the steady flow conditions, flow through each exhaust pipe concentrates on a small region of the monolith. Under the transient flow conditions, flow through each exhaust pipe with the engine firing order interacts with each other to spread the flow over the monolith face. The numerical analysis results support the experimental results, and help explain the flow pattern in the entry region of the CCC.

CFD/RELAP5 coupling analysis of the ISP No. 43 boron dilution experiment

  • Ye, Linrong;Yu, Hao;Wang, Mingjun;Wang, Qianglong;Tian, Wenxi;Qiu, Suizheng;Su, G.H.
    • Nuclear Engineering and Technology
    • /
    • 제54권1호
    • /
    • pp.97-109
    • /
    • 2022
  • Multi-dimensional coupling analysis is a research hot spot in nuclear reactor thermal hydraulic study and both the full-scale system transient response and local key three-dimensional thermal hydraulic phenomenon could be obtained simultaneously, which can achieve the balance between efficiency and accuracy in the numerical simulation of nuclear reactor. A one-dimensional to three-dimensional (1D-3D) coupling platform for the nuclear reactor multi-dimensional analysis is developed by XJTU-NuTheL (Nuclear Thermal-hydraulic Laboratory at Xi'an Jiaotong University) based on the CFD code Fluent and system code RELAP5 through the Dynamic Link Library (DLL) technology and Fluent user-defined functions (UDF). In this paper, the International Standard Problem (ISP) No. 43 is selected as the benchmark and the rapid boron dilution transient in the nuclear reactor is studied with the coupling code. The code validation is conducted first and the numerical simulation results show good agreement with the experimental data. The three-dimensional flow and temperature fields in the downcomer are analyzed in detail during the transient scenarios. The strong reverse flow is observed beneath the inlet cold leg, causing the de-borated water slug to mainly diffuse in the circumferential direction. The deviations between the experimental data and the transients predicted by the coupling code are also discussed.

모세관내 과도유동현상을 이용한 비뉴턴유체의 점도측정 (Viscosity Measurement of Non-Newtonian Fluids Using the Transient Flow Phenomena in the Capillary Tube)

  • 조민태;서상호;유상신
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집E
    • /
    • pp.738-741
    • /
    • 2001
  • The purpose of the present study is to measure the viscosity of liquid in the capillary tube viscometer using the unsteady flow concept. The capillary tube viscometer is consisted of a small cylindrical reservoir, capillary tubes, and the mass flow rate measuring system interfaced with computer. Two capillary tubes with 1.152 and 3.002 mm I.D. are used to determine the diameter effects on the viscosity measurements. The instantaneous shear rate and gravitational driving force in the capillary tube are determined by measuring the mass flow rate through the capillary tube instantaneously. The measured viscosities of water and aqueous Separan solution are in good agreement with the reported experimental data.

  • PDF