• 제목/요약/키워드: transient conditions

검색결과 1,101건 처리시간 0.033초

접시형 태양열 흡수기의 Transient 열전달 특성에 대한 수치해석 연구 (Analysis of Transient Heat Transfer Characteristics of Dish-Type Solar Receiver System)

  • 이주한;서주현;오상준;이진규;서태범
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2094-2099
    • /
    • 2008
  • A numerical and experimental studies are carried out to investigate the transient heat transfer characteristics of 5kWth dish-type solar air receiver. Measured solar radiation and temperatures at several different locations are used as boundary conditions for numerical simulation. Many parameters' effects (reflectivity of the reflector, the thermal conductivity of the receiver body, transmissivity of the quartz window, etc.) on the thermal performance are investigated. Discrete Transfer Method is used to calculate the radiation heat exchange in the receiver. A transient heat transfer model is developed and the rate of radiation, convection and conduction heat transfer are calculated. Comparing the experimental and numerical results, good agreement is obtained. Using the numerical model, the transient heat transfer characteristics of volumetric air receiver for dish-type solar thermal systems are known and the transient thermal performance of the receiver can be estimated.

  • PDF

필릿 용접 공정에서 온도 분포 예측을 위한 해석적 모델 (Analytical Solution for Transient Temperature Distribution in Fillet Arc Welding)

  • 정선국;조형석
    • Journal of Welding and Joining
    • /
    • 제13권2호
    • /
    • pp.68-81
    • /
    • 1995
  • This paper presents an analytical solution to predict the transient temperature distribution in fillet arc welding. The analytical solution is obtained by solving a transient three -dimensional heat conduction equation with convection boundary conditions on the surfaces of an infinite plate with finite thicknesses, and mapping an infinite plate onto the fillet weld geometry with energy equation. The electric arc heat input on fillet weld and on infinite plate is assumed to have a traveling bivariate Gaussian distribution. To check the validity of the solution, GTA and FCA welding experiments were performed under various welding conditions. The actual isotherms of the weldment cross - sections at various distances from the arc start point are compared with those of simulation result. As the result shows a satisfactory accuracy, this analytical solution can be used to predict the transient temperature distribution in the fiIIet weld of finite thickness under a moving bivariate Gaussian distributed heat source. The simplicity and short calculation time of the analytical solution provides rationales to use the analytical solution for modeling the welding control systems or for an optimization tool of welding process parameters.

  • PDF

Transient effects of tendon disconnection on the survivability of a TLP in moderate-strength hurricane conditions

  • Kim, Moo-Hyun;Zhang, Zhi
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제1권1호
    • /
    • pp.13-19
    • /
    • 2009
  • The primary objective of this paper is to investigate the dynamic stability and survivability of a four-column classic TLP (tension-leg platform) under less-than-extreme storm conditions where one or more tendons have been lost due to damage or disconnect. The transient responses of the platform and tendon tensions at the moment of disconnection are particularly underscored. The numerical simulation is based on the BE-FE hybrid hull-tendon-riser coupled dynamic analysis in time domain. Compared to the common industry practice of checking the system without a failed tendon in the beginning, the maximum tension on the neighboring tendon can be significantly increased at the moment of disconnection due to the snap-like transient effects, which can lead to unexpected failure of the total system. It is also found that the transient effects can be reduced with the presence of TTRs (top-tensioned risers) with pneumatic tensioners. It is also seen that the TLP cannot survive in the 100-yr hurricane condition after losing one tendon.

Transient heat transfer of unidirectional (1D) and multidirectional (2D/3D) functionally graded panels

  • Samarjeet Kumar;Vishesh Ranjan Kar
    • Steel and Composite Structures
    • /
    • 제49권5호
    • /
    • pp.587-602
    • /
    • 2023
  • This article presents the numerical modelling of transient heat transfer in highly heterogeneous composite materials where the thermal conductivity, specific heat and density are assumed to be directional-dependent. This article uses a coupled finite element-finite difference scheme to perform the transient heat transfer analysis of unidirectional (1D) and multidirectional (2D/3D) functionally graded composite panels. Here, 1D/2D/3D functionally graded structures are subjected to nonuniform heat source and inhomogeneous boundary conditions. Here, the multidirectional functionally graded materials are modelled by varying material properties in individual or in-combination of spatial directions. Here, fully spatial-dependent material properties are evaluated using Voigt's micromechanics scheme via multivariable power-law functions. The weak form is obtained through the Galerkin method and solved further via the element-space and time-step discretisation through the 2D-isoparametric finite element and the implicit backward finite difference schemes, respectively. The present model is verified by comparing it with the previously reported results and the commercially available finite element tool. The numerous illustrations confirm the significance of boundary conditions and material heterogeneity on the transient temperature responses of 1D/2D/3D functionally graded panels.

원전 밀림관 열성층의 3 차원 수치해석 (3-Dimensional Numerical Analysis for Thermal Stratification in Surgeline in Nuclear Power Plant)

  • 김영종;김만원;고은미
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.729-734
    • /
    • 2008
  • A thermal stratification may occur in the horizontal parts of the surge line during operating transients of the pressurizer, which produces relatively high fatigue usage factor. Heat-up transient is the most severe case among the transient conditions. In this study, to study the relationship between the magnitude of thermal stratification and the length of vertical part of the surge line, some parametric fluid-structure interaction (FSI) analyses with different length variables of the vertical part of the surge line were performed for plant heat-up transient condition by using 3-dimensional numerical analysis. The conservativeness of the traditional finite element model for thermal stratification analysis based on the conservative assumption in the surge line was also discussed by comparison of the results of 3-dimensional transient FSI analysis of this study. Stresses calculated with 3-dimensional transient model were considerably reduced comparing with the traditional analysis.

  • PDF

열응력 및 기계응력이 작용하는 균열배관의 하중조건에 따른 천이 크리프 조건 C(t)-적분 평가 (Estimation of C(t) -Integral Under Transient Creep Conditions for a Cracked Pipe Subjected to Combined Mechanical and Thermal Loads Depending on Loading Conditions)

  • 오창영;송태광;김윤재
    • 대한기계학회논문집A
    • /
    • 제35권6호
    • /
    • pp.609-617
    • /
    • 2011
  • 최근 효율을 높이기 위한 플랜드의 환경이 고온, 고압으로 변화함에 따라 열하중과 기계하중을 동시에 반영한 균열 평가는 플랜트의 건전성을 위하여 반드시 필요하다. C(t)-적분은 고온 균열 평가에 있어서 천이 크리프 상태의 균열을 평가하는 중요한 요소이다. 열하중과 기계하중이 동시에 작용하는 환경에서의 C(t)-적분을 예측하는 것은 복잡하며 하중조건이 달라지는 경우에는 더욱더 복잡해진다. 본 논문에서는 열하중과 기계하중의 하중조건이 달라지는 여러 조건에 대한 C(t)-적분 평가식을 제시하였다.

일시적 혈류 제한과 함께 수행한 저강도 운동 후 알파운동신경원의 변화 (Changes of α-Motor Neuron Excitability after Low-Intensity Exercise with Transient Restriction of Blood Flow)

  • 김종순
    • 대한물리의학회지
    • /
    • 제10권1호
    • /
    • pp.63-69
    • /
    • 2015
  • PURPOSE: Low-intensity exercise with transient restriction of blood flow to muscle could be an alternative rehabilitation method which avoids the problems associated with conventional high-intensity exercise. However, the mechanism of low-intensity exercise with transient restriction of blood flow is not clearly known. Thus, the purpose of this study was to investigate the mechanism of improvement of muscular function after low-intensity exercise with transient restriction of blood flow using H-reflex analysis. METHODS: Twenty one healthy young adults with no medical history of neurological or musculoskeletal disorder voluntarily participated in this study. The ${\alpha}$-motor neuron excitability of the triceps surae was assessed using the H-reflex. The amplitude of the M-wave and H-reflex were measured across three conditions: rest, after low-intensity exercise without restriction of blood flow and after low-intensity exercise with restriction of blood flow. The subjects performed low-intensity ankle plantar flexion exercise at their own pace for one minute without or with transient restriction of blood flow achieved by a sphygmomanometer cuff on popliteal fossa at a pressure of 120mm of mercury(120 mmHg). RESULTS: No significant changes of the excitability of the ${\alpha}$-motor neuron were obtained across three different conditions. CONCLUSION: This study found that low-intensity exercise with transient restriction of blood flow did not influence to ${\alpha}$-motor neuron excitability of the triceps surae. From the results, I could come to the conclusion that further study will be required.

Boundary condition coupling methods and its application to BOP-integrated transient simulation of SMART

  • Jongin Yang;Hong Hyun Son;Yong Jae Lee;Doyoung Shin;Taejin Kim;Seong Soo Choi
    • Nuclear Engineering and Technology
    • /
    • 제55권6호
    • /
    • pp.1974-1987
    • /
    • 2023
  • The load-following operation of small modular reactors (SMRs) requires accurate prediction of transient behaviors that can occur in the balance of plants (BOP) and the nuclear steam supply system (NSSS). However, 1-D thermal-hydraulics analysis codes developed for safety and performance analysis have conventionally excluded the BOP from the simulation by assuming ideal boundary conditions for the main steam and feed water (MS/FW) systems, i.e., an open loop. In this study, we introduced a lumped model of BOP fluid system and coupled it with NSSS without any ideal boundary conditions, i.e., in a closed loop. Various methods for coupling boundary conditions at MS/FW were tested to validate their combination in terms of minimizing numerical instability, which mainly arises from the coupled boundaries. The method exhibiting the best performance was selected and applied to a transient simulation of an integrated NSSS and BOP system of a SMART. For a transient event with core power change of 100-20-100%, the simulation exhibited numerical stability throughout the system without any significant perturbation of thermal-hydraulic parameters. Thus, the introduced boundary-condition coupling method and BOP fluid system model can expectedly be employed for the transient simulation and performance analysis of SMRs requiring daily load-following operations.

온도 변화에 따른 NPT-IGBT의 과도 특성 (Transient Characteristics of NPT-IGBT with different temperatures)

  • 류세환;황광철;안형근;한득영
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집
    • /
    • pp.292-295
    • /
    • 2002
  • In this work, transient characteristics of NPT(Non Punch Through)-IGBT(Insulated Gate Bipolar Transistor) have been studied with different temperatures analytically. Power losses are caused by heat generated in MIT-IGBT for steady state and transient state conditions. We therefore have focused on the analysis of excess carrier concentration and excess charge injected into N-drift layer with different temperatures and have obtained anode voltage drop during turn-off with lifetime of 2.4[${\mu}$s].

  • PDF

Simplified Technique for 3-Dimensional Core T/H Model in CANDU6 Transient Simulation

  • Lim, J.C.
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 1995년도 춘계학술발표회 초록집
    • /
    • pp.113-116
    • /
    • 1995
  • Simplified approach has been adopted for the prediction of the thermal behavior of CANDU reactor core during power transients. Based on the assumption that the ratio of mass flow rate for each core channel does not vary during the transient, quasy-steady state analysis technique is applied with predicted core inlet boundary conditions(total mass flow rate and specific enthalpy). For restricted transient case, the presented method shows functionally reasonable estimation of core thermal behavior which could be implemented in the fast running reactor simulation program.

  • PDF