• 제목/요약/키워드: transfer length method

Search Result 370, Processing Time 0.03 seconds

Design Optimization of Pin-Fin Sharp to Enhance Heat Transfer

  • Li, Ping;Kim, Kwang-Yong
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2005년도 연구개발 발표회 논문집
    • /
    • pp.185-190
    • /
    • 2005
  • This work presents a numerical procedure to optimize the elliptic-shaped pin fin arrays to enhance turbulent heat transfer. The response surface method is used as an optimization technique with Reynolds-averaged Navier Stokes analysis of flow and heat transfer. Shear stress transport (SST) turbulence model is used as a turbulence closure. Computational results for average heat transfer rate show a reasonable agreement with the experimental data. Four variables including major axis length, minor axis length, pitch and the pin fin length nondimensionalized by duct height are chosen as design variables. The objective function is defined as a linear combination of heat transfer and friction-loss related terms with weighting factor. D-optimal design is used to reduce the data points, and, with only 28 points, reliable response surface is obtained. Optimum shapes of the pin-fin arrays have been obtained in the range from 0.0 to 0.1 of weighting factor.

  • PDF

돌출부를 갖는 평행평판의 최적 설계를 위한 층류강제대류 해석 (Analysis of laminar forced convection for optimal design of parallel plates with protrusions)

  • 이관수;박철균
    • 설비공학논문집
    • /
    • 제10권1호
    • /
    • pp.129-136
    • /
    • 1998
  • Pressure drop and heat transfer characteristics of a periodically fully developed flow in the flat channel with protrusions are investigated. The effects of shape and location of protrusion on the pressure drop and heat transfer are numerically analyzed in the present study. Taguchi method is used to optimize these parameters. It is found that the ratio of the height of protrusion to channel height shows larger influence on the pressure drop and heat transfer than the ratio of the length of protrusion to module length. As the height of protrusion increases, pressure drop and heat transfer increase, but if the height of protrusion exceeds 2/3 of the channel height, there is a substantial pressure drop. The results also show that the optimal length and height of protrusion are half of the module length and half of the channel height, respectively.

  • PDF

국내산 7연강선의 트렌스퍼 정착부착 실험 (Transfer Bond test on Domestic Sevenwire Prestressing Strands)

  • 김승욱;김대훈;유재천;유승룡
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 봄 학술발표회 논문집(I)
    • /
    • pp.387-392
    • /
    • 1999
  • The bond performance of prestressing strands is still not well understood and is still in controversy on the validity of the test results up to today, although it is a basic information to desing the prestressed pretensioned concrete beams. Different transfer length has been found for a product of the same company, but of the different production methods and factories in the United States. It is necessary to determine optimum transfer bond length of the domestic stands because the ultimate flexural and shear capacity in a section of prestressed concrete beams are evaluated under the assumption that the anchorage bond failure shall not happen. The transfer lenght of low-relaxation, Gr 270, and 1/2" seven-wire prestressing strands from four domestic companies will be evaluated by the concrete strain method. The recent concept of the 95% Maximum Average Strain Method suggested by Russel et al. will be considered to obtain the transfer length of domestic strands. It will be also evaluated if the domestic strands are conform to ACI 318-95.8-95.

  • PDF

수평격판을 갖는 정사각형 밀폐공간내에서 자연대류 유동 및 열전달 (Natural Convective Flow and Heat Transfer in a Square Enclosure with a Horizontal Partition)

  • 정인기;김점수;송동주
    • 대한기계학회논문집
    • /
    • 제17권9호
    • /
    • pp.2304-2314
    • /
    • 1993
  • Natural convective flow and heat transfer in a two-dimensional square enclosure fitted with a horizontal partition are investigated numerically. The enclosure was composed of the lower hot and the upper cold horizontal walls and the adiabatic vertical walls, and a partition was situated perpendicularly at the one vertical insulated wall. The governing equations are solved by using the finite element method with Galerkin method. The computations were carried out with the variations of length, position and thermal conductivity of the partition, and Rayleigh number based on the temperature difference between two horizontal walls and the enclosure height with water(Pr=4.95). As the results, an oscillatory motion of natural convection is resulted in a sudden rise of overall heat transfer, but the increase of length of partition is significantly restrained the increase of Nusselt number. The maximum heat transfer was shown just before the transition of the direction of oscillating flow. An oscillatory motion of flow was perfectly shown the stability with the decrease of the length of partition and Rayleigh number. Also, the heat transfer was raised with the increase of the thermal conductivity in proportion to the increase of the length of partition. The stability and oscillation of flow are affected by the position of partition.

위성과 지상회선에서 파일전송을 위한 확장된 SARA 모델 시뮬레이터 구성 (Construction of a Simulator by Expanded SARA Model for File Transfer via Satellite and Terrestrial Links)

  • 박진양
    • 한국컴퓨터산업학회논문지
    • /
    • 제2권2호
    • /
    • pp.131-140
    • /
    • 2001
  • 본 논문은 지상회선과 위성회선의 파일 전송을 위하여 CSDN 접속의 지상회선 모델인 SARA(System ARchitec’ Apprentice)모델에 위성회선을 추가하여 확장된 시뮬레이터를 제안하고 두 회선의 파일전송 효율에 대하여 해석하였다. 위성전송에서 파일전송의 효율을 평가하기 위하여 해석적 방법과 제안된 시뮬레이터로서 파일전송의 시뮬레이션을 수행하였다. 이때 적용된 전송파라미터는 단위 메시지 길이와 파일의 전송시간, 체인 레코드 수와 전송시간으로 하여 위성회선의 최적 메시지 길이를 평가하였다. 평가 결과는 위성회선에서 단위 메시지 길이를 512바이트 보다 짧게 하면 파일 전송시간은 극단적으로 길게 되며,1024바이트로 했을 때 최소로 되고 2048바이트부터 급격하게 증가되었다. 이 결과에서 최적 단위 메시지길이는 1024바이트 부근이라는 것을 확인할 수 있었다.

  • PDF

다양한 지표면 위에서 총체 전달 방법에 의한 대기 난류 플럭스 추정 (Estimation of Atmospheric Turbulent Fluxes by the Bulk Transfer Method over Various Surface)

  • 김민성;권병혁;강동환
    • 한국환경과학회지
    • /
    • 제23권6호
    • /
    • pp.1199-1211
    • /
    • 2014
  • The momentum flux and the sensible heat flux were measured with the scintillometers and ultrasonic anemometers at 6 sites of which surface characteristics like roughness length and zero-displacement are different each other. We estimated the momentum flux and the sensible heat flux based on the bulk transfer method with the drag coefficient and the heat transfer coefficient calculated from the temperature and wind speed at two heights. The variation of bulk transfer coefficients showed a remarkable difference depending on the atmospheric stability which is less influenced by the zero-displacement than the roughness length. The estimated sensible heat fluxes were in good agreement with those measured at 3 m, showing 23.7 $Wm^{-2}$ of the root mean square error that is less than 10% of its maximum. Since the estimated momentum flux is not only effected by drag coefficient but also by wind speed square, the determination of wind speed in the bulk transfer method is critical.

격판을 가진 밀폐공간내의 자연대류 열전달에 공간 및 격판의 경사가 미치는 영향 (Effects of Inclination of Enclosure and Partition on Natural Convective Heat Transfer in a Partitioned Enclosure)

  • 정인기;송동주;김점수
    • 설비공학논문집
    • /
    • 제6권3호
    • /
    • pp.302-314
    • /
    • 1994
  • The effects of the inclination of enclosure and partition on natural convective flow and heat transfer were investigated numerically. The enclosure was composed of the lower hot and the upper cold horizontal walls and the adiabatic vertical walls, and a partition was positioned perpendicularly at the mid-height of one vertical insulated wall. The governing equations are solved by using the finite element method with Galerkin method. The computations were performed with the variations of the partition length and Rayleigh number based on the temperature difference between two horizontal walls and the enclosure height with water(Pr=4.95). The effects of the inclination angle of enclosure and partition on the heat transfer within an enclosure were also studied. As the results, the increase of the inclination angle of enclosure rapidly raised the heat transfer rate, while the inclination angle for the maximum Nusselt number was retarded with the increase of the partition length and the decrease of the heat transfer rate became larger in proportion to the increase of the partition length. The Nusselt number obtained by the inclination of partition was smaller than that of the inclination of enclosure. However, the difference of the heat transfer rates was considerably decreased at the longer partition lengths and the trends for the variation of the average Nusselt number were more similar with that of the inclination of enclosure. The upward oriented partition increases the convective heat transfer distinctly in contrast to that of the inclination of enclosure as the partition length increases.

  • PDF

Portable Calibration System for Displacement Measuring Sensors

  • Eom, Tae-Bong;Lee, Jae-Yun;Kim, Jae-Wan;Joon, Lyou
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제7권2호
    • /
    • pp.56-59
    • /
    • 2006
  • A vibrational model of powder transfer equipment based on the lumped parameter method was developed, in which the operating motion consists of surging, bouncing, and pitching. After decoupling the equation of motion, the vibrational excitation source of the pitching motion was removed. So the designers are able to plan the optimum design to adjust the motion trajectory of the powder transfer equipment. That is, a procedure to adjust the motion trajectory of powder transfer equipment by changing design specifications such as the installation position, the direction of the motor, the driving speed, the mass unbalance, the stiffness coefficient, and the installation position of the support spring, is presented in this paper. The powder transfer equipment manufactured according to the results of this study did not suffer fatigue destruction, since the maximum stress on the basket structure was sufficiently small.

차폐막이 있는 밀폐공간 내에서의 난류 자연대류 - 복사열전달에 관한 연구 (A Study on the Turbulent Natural Convection - Radiative Heat Transfer In a Partitioned Enclosure)

  • 박경우;이주형;박희용
    • 대한기계학회논문집
    • /
    • 제18권10호
    • /
    • pp.2738-2750
    • /
    • 1994
  • The Effects of radiative heat transfer on turbulent flow in a partitioned enclosure is studied numerically. The enclosure is partially divided by a thin, poorly conducting vertical divider projecting from the ceiling of the enclosure. The low Reynolds number $k-{\epsilon}$ model is adopted to calculate the turbulent flow field. The solutions to the radiative transfer equations are obtained by the discrete ordinates method(DOM). This method is based on control volume method and is compatible with the SIMPLER algorithm used to solve the momentum and energy equations. The effects of optical thickness and Planck number on the flow, temperature fields and heat transfer rates are investigated for a moderate Rayleigh number($=10^9$). The changes in buoyant flow fields and temperature distributions due to the variation of baffle length are also analyzed. From the predictions, radiant heat exchange between the baffle and the sidewalls strongly influences the temperature distribution in the baffle and its vicinity and total heat transfer increases as the optical thickness and the baffle length decrease. It is possible to neglect the radiative heat transfer effect when Planck number is over one.

에폭시 코팅 처리된 PS강선의 정착부착성능 실험 (Tests on Transfer Bond Performance of Epoxy Coated Prestressing Strands)

  • 유승룡
    • 콘크리트학회지
    • /
    • 제6권1호
    • /
    • pp.89-100
    • /
    • 1994
  • 프리스트레스 프리텐숀 보의 전달길이를 위하여 콘크리트의 변형율에 의하여 부착력을 계측하는 간접적인 방법을 일반적으로 사용하여 왔다. 이 트랜스퍼 실험은 실제 보에서 행하여지므로, 실제 상태의 정착부착력을 계측할 수 있다는 장점이 있으나, 최대 정착부착응력과 부착강비를 구하기 난해하며, 그 결과가 매우 분산되어 있으므로, 구조 설계자가 안전한 적정기준을 이해하고 선택하기 어렵다. 콘크리트의 변형을 측정하지 않아도 PS 강선의 정착부착 성능을 얻을 수 있는 대안을 소개하였다. 실제 보에서 PS강재의 긴장을 풀 때와 유사한 상황에서 정축부착 응력을 직접 구하였다. 하중재하부에서 풀려진 PS강선의 긴장력은 하중재하부쪽 강선의 단면증가를 가져오고, 콘크리트 블록에 정착부착력을 발생시키며, 다른 방향(고정부 쪽)으로 슬립을 유발시킨다. 두 개의 중공 로드셀로 양단하중을 최대 부착응력 또는 전면슬립이 일어날 때까지 계측하였다. 프리텐션 콘크리트보의 정착부착 길이를 구하기 위하여 이 방법을 기존의 트랜스퍼 실험방법과 병행하여 사용할 것을 제안한다.