• Title/Summary/Keyword: transducers

Search Result 856, Processing Time 0.026 seconds

Applications of Strain Gages to Farm Machine Elements (농업기계 요소의 스트레인 게이지 응용에 관한 연구)

  • 류관희;정창주;고학균;최재갑;유수남
    • Journal of Biosystems Engineering
    • /
    • v.5 no.2
    • /
    • pp.40-57
    • /
    • 1980
  • The aim of this study was to promote extensive use of strain gage for accurate measurement in the area of farm machinery research. The results are summarized as follows. 1. Although many strain gate transducers commercially available such as load-cells , accelerometers and pressure transducers have been used in the area of farm machinery research, many types of transducers had to be developed due to the inadaptability or high cost commercial transducers, in many instances. 2. A strain -gaged cantilever beam could be used as a good educational material to demonstrate the methods of Wheatstone bridge arrangement, calibration and theoreticval computation. A ring type load-cell and shaft torque transducer also could be used for the same purpose. 3. The torque and angular speed transducers for an auto-feed thresher and the displacement and pressure transducers for a rice whitener were made and gave satisfactory results. 4. Based on the above results, it is possible to develop simple and low-cost transducers to measure displacement, angular speed , torque and pressure of farm machine elements.

  • PDF

Development of Piezoelectric Transducers For Measuring Dynamic Stiffness of Subsurface Materials (지반의 동적 물성치 측정을 위한 압전소자형 계측기 개발)

  • 목영진
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1997.10a
    • /
    • pp.101-108
    • /
    • 1997
  • A pair of piezoelectric transducers was developed for geotechnical site characterization in rock materials. SH-wave measurement capability of the transducers can provide a more complete characterization. The performance of the transducers was tested at a limestone site.

  • PDF

Structural health monitoring using piezoceramic transducers as strain gauges and acoustic emission sensors simultaneously

  • Huo, Linsheng;Li, Xu;Chen, Dongdong;Li, Hongnan
    • Computers and Concrete
    • /
    • v.20 no.5
    • /
    • pp.595-603
    • /
    • 2017
  • Piezoceramic transducers have been widely used in the health monitoring of civil structures. However, in most cases, they are used as sensors either to measure strain or receive stress waves. This paper proposes a method of using piezoelectric transducers as strain gauges and acoustic emission (AE) sensors simultaneously. The signals received by piezoceramic transducers are decomposed into different frequency components for various analysis purposes. The low-frequency signals are used to measure strain, whereas the high-frequency signals are used as acoustic emission signal associated with local damage. The b-value theory is used to process the AE signal in piezoceramic transducers. The proposed method was applied in the bending failure experiments of two reinforced concrete beams to verify its feasibility. The results showed that the extracted low-frequency signals from the piezoceramic transducers had good agreement with that from the strain gauge, and the processed high-frequency signal from piezoceramic transducers as AE could indicate the local damage to concrete. The experimental results verified the feasibly of structural health monitoring using piezoceramic transducers as strain gauges and AE sensors simultaneously, which can advance their application in civil engineering.

Vibration Characteristics of Stacked Piezoelectric Transducers (적층 압전 변환기의 진동 특성)

  • Kim, Dae Jong;Kim, Jin Oh
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.25 no.3
    • /
    • pp.199-206
    • /
    • 2015
  • This paper deals with the vibration characteristics of stacked transducers composed of piezoelectric discs, which are main elements of ultrasonic sensors or actuators. The stacked transducers were devised in the sense of natural frequencies. Two- or three-layer transducers were fabricated with piezoelectric discs of different diameters. The natural frequencies were determined by the finite element analysis and they were verified by comparing them with experimental results. It appeared that the natural frequencies of the stacked piezoelectric transducers include the natural frequencies of the constituent piezoelectric discs and the natural frequencies caused by stacking. Based on these results, it would be possible to predict the vibration characteristics of the stacked piezoelectric transducers in a design process.

In-house calibration of pressure transducers and effect of material thickness

  • Dave, Trudeep N.;Dasaka, S.M.
    • Geomechanics and Engineering
    • /
    • v.5 no.1
    • /
    • pp.1-15
    • /
    • 2013
  • Pressure transducers are increasingly used within soil mass or at soil-structure interface for appraisal of stresses acting at point of installation. Calibration of pressure transducers provides a unique relationship between applied pressure and voltage or strain sensed by transducer during various loading conditions and is crucial for proper interpretation of results obtained from pressure transducers. In the present study an in-house calibration device is used to calibrate pressure transducers and the study is divided into two parts: 1) demonstration of developed calibration device for fluid and in-soil calibration of pressure transducers; 2) effect of soil layer thickness on the earth pressure cell (EPC) output. Results obtained from the present study revealed successful performance of the developed calibration device, and significant effect of sand layer thickness on the calibration results. The optimum sand layer thickness is obtained as 1.5 times the diameter of EPC.

Radiation Pattern of the Vibrox Transducer (자외성 페라이트 진동자의 지향특성에 대하여)

  • 신형일
    • Journal of the Korean Institute of Navigation
    • /
    • v.4 no.2
    • /
    • pp.1-6
    • /
    • 1980
  • Computer simulation results on the radiation pattern of an ultrasonic beam by the plurall arrangement of the transducers were reported by Sin (1979). This paper describes on the measurement of radiation pattern in case of one vibrox transducer and two vibrox transducers by varying the interval between the transducers. The measured results obtained are as follows; 1. Radiation wave of ultrasonic transducer is propagated to diffuse with spherical wave from center of transducer. 2. In case of one vibrox transducer, the greater the length of transducer, the sharper becomes the radiation pattern. 3. In case of two vibrox transducers, the maine lobe is revealed at the center of two transducers, it is shown difficult to make control freely of radiation pattern by varying merely the interval of transducers.

  • PDF

Comparison of Ultrasonic Velocities between Direct and Indirect Methods on 30 mm × 30 mm Spruce Lumber

  • OH, Sei Chang
    • Journal of the Korean Wood Science and Technology
    • /
    • v.48 no.4
    • /
    • pp.562-568
    • /
    • 2020
  • This study investigates the relationship between ultrasonic velocity and density in the direct method, the effect of distance between transducers in the indirect method, and the difference between the direct and indirect methods with transducers placed at a distance of 200 mm in nondestructive ultrasonic testing of spruce lumber. The direct method using 54 kHz ultrasonic transducers was applied to two planes, namely, radial section (LR) and tangential section (LT) of samples. The indirect method measurements were taken using the same transducers. Two velocities were measured at the top and bottom of the LT plane and at the two sides of the LR plane; the two values for each plane were averaged. The relationship between density and ultrasound velocity in the direct method demonstrated a positive correlation between the two variables. The difference between the two planes, LT and LR, was not statistically significant. Moreover, the distance between the transducers in the indirect method affected ultrasound velocity, with the ultrasonic velocity increasing as the distance between the transducers became larger. A transducer distance of 200 mm yielded a close approximation of the direct method results with a ratio of 0.87. Finally, no statistical evidence of a difference between the two planes in the indirect method was found. If the direct method, which requires access to two surfaces, is impractical, the indirect method can be applied.

The Characteristics of Phase Variation by Depth of Water Column and the Correlation between Channels of Vertical Array Receiver at East Sea (동해 천해환경에서 수심에 따라 변화하는 위상 변동의 특성과 상관관계 분석)

  • Choi, Dong-Hyun;Kim, Hyeon-Su;Kim, Nam-Ri;Kim, Seong-Il;Chung, Jae-Hak
    • The Journal of the Acoustical Society of Korea
    • /
    • v.29 no.3
    • /
    • pp.165-172
    • /
    • 2010
  • It is important to determine the communicational method that knows the characteristic of phase variation along transducers formed array within the water column in actual underwater environment and the correlation between transducers. This paper analyzes the characteristic of phase variation that vary on different locations by probe signals that transmitted from a probe source and received along transducers. This paper calculated the theoretical transmission capacities by the analyzation of the correlation between transducers through changing the distance between transducers and the distance between a probe source and transducers.

Electromechanical analysis of 2-2 cement-based piezoelectric transducers in series electrically

  • Wang, Jianjun;Shi, Zhifei
    • Smart Structures and Systems
    • /
    • v.14 no.3
    • /
    • pp.267-284
    • /
    • 2014
  • This paper aims to present the analytical solutions of 2-2 cement based piezoelectric transducers in series electrically based on the theory of piezo-elastic dynamics. The solutions of two different kinds of 2-2 cement based piezoelectric transducers under external harmonic load are obtained by using the displacement method. The effects of electrical connection of piezoelectric layers, loading frequency, thickness and distance of piezoelectric layers on the characteristics of the transducers are discussed. Comparisons with other related experimental investigations are also given, and good agreement is found. The proposed 2-2 cement based piezoelectric transducers have a great potential application in monitoring structural health in civil engineering and capturing mechanical energy or monitoring train-running safety in railway system and traffic safety in road system.

A Study on the Control of the Radiation Pattern of an Ultra-Sonic Beam by the Plural Arrangement of the Transducers (초음파진동자의 복수배열에 의한 지향성가변에 관한 연구)

  • 신형일
    • Journal of the Korean Institute of Navigation
    • /
    • v.3 no.2
    • /
    • pp.21-30
    • /
    • 1979
  • Echo sounder and Doppler sonar are to theultra-sonic transducers for measuring the depth and the ship's speed respectively. To measure the depth and speed with a single transducer, it is required to control the ultra-sonic beam to optional direction. In the past, the direction of the transducer itself is varied, but such a method provoked much problems in the mechanical design of the equipment. This paper deals with the method to control beam direciton by the phase control of the plural arrangement of transducers, and the results are studied by a computer simulation. The remarkable results of the study is condensed as follows; 1. The greater the interval of arrangement between transducers, the sharper the radiation pattern is, but in this case, the level of undesired sidelobe is also increased. 2. The control of radiation pattern up to 60 degree can be achieved by an adequate arrangement of more than 10 transducers. 3. It is shown that a simultaneous measurement of both depth and speed can be achieved by alternating directivity of the pulse by the method proposed in this paper.

  • PDF