• Title/Summary/Keyword: transducer design

Search Result 383, Processing Time 0.034 seconds

Verification of Practicality for the SSBL and Pinger Synchronizing Biotelemetry Method and System through the Tracking of Fish (어류의 행동추적에 의한 SSBL · 핑거동기 바이오텔레메터리 방식과 시스템의 실용성 검증)

  • Park, Ju-Sam
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.40 no.1
    • /
    • pp.78-85
    • /
    • 2004
  • The new biotelemetry method and system that the installation and the treatment of equipment is convenient and the instantaneously detailed position of the fish attached a pinger is able to track comparatively easily had been developed, an practicality of it were verified in the water tank and the small sea port through the tracking of fish. The biotelemetry method had been gotten the three dimensional locations of fish to the receiving transducer by combining of the super short base line (SSBL) method to detect the direction of pinger and the pinger synchronizing method to measure the range from receiving transducer to pinger. The receiving system had been designed to realize the high precision or wide detection range by application of the basic design method for receiving system of biotelemetry and the hydrophone array configuration. From tracking test of carp in the water tank, the migration course and the velocity of carp was investigated and the observed migration course was compared with measurement. The measured migration course of carp coincided with the observation in the main and the position of carp was able to track three dimensionally. The velocity of carp measured by the moving average method was 11.2cm/s. From tracking test of yellowtail in the small sea port, the migration course and the velocity of yellowtail was investigated at natural condition. The position of yellowtail was able to track three dimensionally and the velocity of it measured by moving average method was 43.9cm/s.

Use of real-time ultrasound imaging for biofeedback of diaphragm motion during normal breathing in healthy subjects

  • Cho, Ji-Eun;Hwang, Dal-Yeon;Hahn, Joohee;Lee, Wan-Hee
    • Physical Therapy Rehabilitation Science
    • /
    • v.7 no.3
    • /
    • pp.95-101
    • /
    • 2018
  • Objective: To determine if the provision of visual biofeedback using real-time rehabilitative ultrasound imaging (RUSI) enhances the acquisition and retention of diaphragm muscle recruitment during exercise. Design: Two group pretest posttest design. Methods: Thirty healthy subjects were randomly assigned to the verbal feedback group (VG, n=15) or the visual and verbal feedback group (VVG, n=15). The VG performed breathing exercises 10 times with verbal feedback, and the VVG also performed breathing exercises 10 times with verbal feedback and visual feedback with the use of RUSI to measure changes in diaphragm thickness (DT). For DT, the mid-axillary lines between ribs 8 and 9 on both sides were measured in standing, and then the chest wall was perpendicularly illuminated using a linear transducer with the patients in supine to observe the region between rib 8 and 9 and to obtain 2-dimensional images. DT was measured as the distance between the two parallel lines that appeared bright in the middle of the pleura and the peritoneum. After one week, three repetitions (follow-up session) were performed to confirm retention effects. Intra- and between- group percent changes in diaphragm muscle thickness were assessed. Results: In the VVG, the intervention value had a medium effect size compared to the baseline value, but the follow-up value decreased to a small effect size. In the between-group comparisons, during the intervention session, the VVG showed no significant effect on percent change of DT but had a medium effect size compared to the VG (p=0.050, Cohen's d=0.764). During the follow-up session, retention effect did not persist (p=0.311, Cohen's d=0.381). Conclusions: RUSI can be used to provide visual biofeedback and improve performance and retention in the ability to activate the diaphragm muscle in healthy subjects. Future research needs to establish a protocol for respiratory intervention to maintain the effect of diaphragmatic breathing training using RUSI with visual feedback.

A Study on Design and Fabricate of a Intermediate Frequency Band SAW Filter (IF 대역 SAW 필터 설계 및 제작)

  • 유일현;권희두;정양희
    • The Journal of the Acoustical Society of Korea
    • /
    • v.18 no.1
    • /
    • pp.10-15
    • /
    • 1999
  • We have studied a method to design and fabricate the Intermediate Frequency(IF) band pass filter with low shape factor which is used for CDMA base station on the 35°Y-cut X-propagation Quartz substrate. In order to fabricate a device of the low shape factor for the IF SAW filter on this substrate, we employed apodization weighted type interdigital transducer(IDT) as an input and withdrawal weighted type IDT as an output by using impulse modelling method. Also, using the Kaiser-Bessel window function, we have adopted 2200pairs and 1000pairs of input and oueut IDT respectively to minimize the effect of ripple. Furthermore, the width and the space of IDT finger are 3.6 ㎛ and 3.5 ㎛ respectively. Thus, we can have optimal results when the IDT thickness is 6000Å in consideration of the ratio of SAW's wavelength while it's aperture is 2mm for impedance matching. The fabricated SAW filter for CDMA had the property of almost 115.2MHz of a center frequency, less then 1.27MHz of bandwidth, less than 1.3 of shape factor, - l5dB of out band attenuation insertion loss and -45dB of rejection band.

  • PDF

The Silicon Type Load Cell with SUS630 Diaphragm (SUS630 다이아프램을 이용한 반도체식 로드셀)

  • Moon, Young-Soon;Lee, Seon-Gil;Ryu, Sang-Hyuk;Choi, Sie-Young
    • Journal of Sensor Science and Technology
    • /
    • v.20 no.3
    • /
    • pp.213-218
    • /
    • 2011
  • The load cell is a force sensor and a transducer that is used to convert a physical force into a electrical signal for weighing equipment. Most conventional load cells are widely used a metal foil strain gauge for sensing element when force being applied spring element in order to converts the deformation to electrical signals. The sensitivity of a load cell is limited by its low gauge factor, hysteresis and creep. But silicon-based sensors perform with higher reliability. This paper presents the basic design and development of the silicon type load cell with an SUS630 diaphragm. The load cell consists of two parts the silicon strain gauge and the SUS630 structure with diaphragm. Structure analysis of load cell was researched by theory to optimize the load cell diaphragm design and to determine the position of peizoresistors on a silicon strain gauge. The piezo-resistors are integrated in the four points of silicon strain gauge processed by ion implantation. The thickness of the silicon strain gauge was polished by CMP under 100 ${\mu}M$. The 10 mm diameter SUS630 diaphragm was designed for loads up to 10 kg with 300 ${\mu}M$ of diaphragm thickness. The load cell was successfully tested, the variation of ${\Delta}$R(%) of four points on the silicon strain gauge is good linearity properties and sensitivity.

A comparison of the implant stability among various implant systems: clinical study

  • Kim, Jae-Min;Kim, Sun-Jong;Han, In-Ho;Shin, Sang-Wan;Ryu, Jae-Jun
    • The Journal of Advanced Prosthodontics
    • /
    • v.1 no.1
    • /
    • pp.31-36
    • /
    • 2009
  • PURPOSE. To determine the change in stability of single-stage, three different design of implant systems in humans utilizing resonance frequency analysis for early healing period(24 weeks), without loading. MATERIAL AND METHODS. Twenty-five patients were included into this study. A total of 45 implants, three different design of implant systems(group A,C,R) were placed in the posterior maxilla or mandible. The specific transducer for each implant system was used. ISQ(implant stability quotient) reading were obtained for each implant at the time of surgery, 3, 6, 8, 10, 12, 24 weeks postoperatively. Data were analyzed for different implant type, bone type, healing time, anatomical locations. RESULTS. For each implant system, a two-factor mixed-model ANOVA demonstrated that a significant effect on ISQ values(group A=0.0022, C=0.017, R=0.0018). For each implant system, in a two-factor mixed model ANOVA, and two-sample t-test, the main effect of jaw position(P > .005) on ISQ values were not significant. CONCLUSIONS. All the implant groups A, C and R, the change patterns of ISQ over time differed by bone type. Implant stability increased greatly between week 0 and week six and showed slow increase between week six and six months(plateau effect).

Design and Implementation of a Micro-Modem for Underwater Acoustic Communications (수중 음향 통신을 위한 초소형 모뎀 설계 및 구현)

  • Jeon, Jun-Ho;Cho, Hun-Chul;Kim, Chang-Hwa;Ryuh, Young-Sun;Park, Sung-Joon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.4B
    • /
    • pp.405-411
    • /
    • 2011
  • As the interest in ocean environment monitoring and ocean development has been increased, the need for researches on underwater wireless sensor network (UWSN) and low power consuming acoustic modem for UWSN has been arisen. In this paper, we design and implement a micro-modem equipped with a tiny and omnidirectional transducer for underwater acoustic communications. In addition, we make experiments in a water tank and a pond in order to verify the performance of the developed modem in terms of supply voltage and communication distance, and analyze the results. According to the outdoor experiments, the modem can send data wirelessly in underwater at a distance of 40 meter with a data rate of 200 bps and a bit error rate of $10^{-5}$ when the supply voltage is 12 V. Due to its small size, low power consumption and omnidirectional property, it is expected that the modem which is implemented in this paper could be utilized for various applications based on UWSN.

Flow characteristics analysis and test in the Pelton turbine for pico hydro power using surplus water (잉여 유출수를 이용한 소수력발전용 수차의 유동특성 해석 및 시험)

  • Jeong, Seon Yong;Lee, Kye Bock
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.4
    • /
    • pp.325-331
    • /
    • 2016
  • Computational fluid numerical analysis using the commercial code CFX was performed to develop a Pelton turbine for a pico hydro power generator using the circulating water of a cooling tower in a large building. The performance of the Pelton turbine was examined for different design factors, such as the bucket shape, in which the Pelton wheel was connected in an appropriate manner to the pipe section, and the number of buckets in order to find the optimal design of Pelton turbine for a pico hydro power using surplus water. A benchmark test was carried out on the manufactured small scale Pelton turbine to validate the design method of the Pelton turbine by numerical analysis. The results obtained by comparing the flow characteristics and power output measured using the ultrasonic flowmeter, the pressure transducer and the oscilloscope with the numerical results confirmed the validity of the analytical design method. The possibility of developing Pelton turbines for kW class pico hydro power generators using surplus water with an average circulation velocity of 1.2 m/s for the chosen bucket shape and number of buckets in a 30 m high building was confirmed.

Design and Experimental Results for Cooling Tubes of Ultrasonic Bonding Equipment of Ultrasonic Bonding Equipment (초음파 접합 장치의 냉각관 설계 및 접합강도 실험)

  • Lee, DongWook;Jeon, EuySick
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.4
    • /
    • pp.1879-1884
    • /
    • 2014
  • Recently, the micro bonding technology comes into the spotlight as the miniaturization of the electronic product. The micro bonding technique can classify by way of laser welding and ultrasonic bonding and etc. However, the research on the micro bonding is much lacks. In this paper, carried out the cooling analysis of the 60 [kHz] ultrasonic bonding equipment to know heat effect of the piezoelectric element when the ultrasonic bonding equipment was operated. The ultrasonic horn having the natural frequency with 60 [kHz] for the dissimilar material bonding of the glass and solder tried to be designed. The parameters and response was set through the basic experiment. The dissimilar material bonding strength analysis using the 60 [kHz] ultrasonic bonding equipment was done. We carried out the bonding for improving bonding strength to using the silver paste. air thightness of bonding surface was confirmed by analysis of bonding interfaces.

Design of an Energy Harvesting Circuit Using Solar and Vibration Energy with MPPT Control (MPPT 제어기능을 갖는 빛과 진동 에너지를 이용한 에너지 하베스팅 회로 설계)

  • Yoon, Eun-Jung;Hwang, In-Ho;Park, Jong-Tae;Yu, Chong-Gun
    • Journal of IKEEE
    • /
    • v.16 no.3
    • /
    • pp.224-234
    • /
    • 2012
  • This paper describes an energy harvesting circuit using solar and vibration energy with MPPT(Maximum Power Point Tracking) control for micro sensor nodes. The designed circuit employs MPPT control to harvest maximum power available from a PZT vibration element and an integrated solar cell. The harvested energies are simultaneously combined and stored in a storage capacitor, and then managed and transferred into sensor node by PMU(Power Management Unit). MPPT controls are implemented using the linear relationship between the open-circuit voltage of an energy transducer and its MPP(Maximum Power Point) voltage. The proposed circuit is designed in a CMOS 0.18um technology and its functionality has been verified through extensive simulations. The designed energy harvesting circuit and integrated solar cell occupy $2.85mm^2$ and $8mm^2$ respectively.

Evaluation of Fatigue Damage of Metal Matrix Composite by LFB Acoustic Microscopy (Line-Focus-Beam 초음파 현미경을 이용한 금속복합재료의 피로손상에 관한 연구)

  • Lee, Joon-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.13 no.2
    • /
    • pp.40-47
    • /
    • 1993
  • Composites composed of a precipitation harden 2124 alloy matrix reinforced by SiC whiskers, which are fabricated by powder metallugy, are suscepttible to fatigue damage due to the pile-up of moving dislocation and the microcrack initiation along SiC-Al interfaces, especially at the external surfaces of a body. The initial process, such as pile-up of dislocation or microcrack, that corresponds to the stage I during fatigue failure process are too small to be detected and characterized by conventional ultrasonic technique. This paper describes the applicability of an acoustic microscope with Line-Focus-Beam(LFB) lens of 225MHz to evaluate fatigue damage of SiC whiskers reinforced Al alloy. The specimens which were 6.6mm thick, 13mm wide, and 105mm long in the gage section were fatigued in tension-tension under load control. The velocity of leaky surface and leaky pseudosurface acoustic waves are obtained by FFT analysis technique from V(z) curve which is a record of output of piezoelectric transducer. These results are discussed with the change of number of fatigue cycles. The result obtained by acoustic microscope is compared with that by ultrasonic technique generated at 5MHz with conventional surface wave transducers.

  • PDF