Design of a wideband cymbal transducer array (광대역 심벌 트랜스듀서 배열 설계)

  • Kim, Donghyun;Roh, Yongrae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.39 no.3
    • /
    • pp.170-178
    • /
    • 2020
  • Cymbal transducers are often used as an array rather than single because they have a high quality factor and low energy conversion efficiency. When used as an array, there occurs a big change in the frequency characteristics of the array due to the interaction between constituent transducers. In this study, we designed the structure of a cymbal transducer array to have ultra-wideband characteristics using this property. First, cymbal transducers with specific center frequencies were designed. Then, a 2×2 planar array was constructed with the designed transducers, where the cymbal transducers were arranged to have same or opposite polarization directions. For this structure, we analyzed the effect of the difference in the center frequency of and the spacing between the constituent transducers on the acoustical characteristics of the array. Based on the analysis, we designed the structure of the cymbal transducer array to have the widest possible bandwidth.

Transducer analysis and signal processing of PMSF with embedded bluff body

  • Yan, Xiao-Xue;Xu, Ke-Jun;Xu, Wei;Yu, Xin-Long;Wu, Jian-Ping
    • Nuclear Engineering and Technology
    • /
    • v.52 no.2
    • /
    • pp.296-307
    • /
    • 2020
  • Permanent magnet sodium flowmeter (PMSF) have been used to measure the sodium flow in fast breeder reactors. Due to the effects of irradiation, thermal cycling, time lapse, etc., the magnetic flux density of the PMSF will decrease after being used in the reactor for a period of time. Therefore, it must be calibrated regularly. But some flowmeters that immersed in sodium cannot be removed for an off-line calibration, so the on-line calibration is required. However, the best online calibration accuracy of PMSF using cross-correlation analysis method was 2.0-level without considering the repeatability. In order to further improve this work, the operational principle of the transducer in PMSF is analyzed and the design principle of the transducer is proposed. The transducers were tested on the sodium flow loop to collect the experimental data. The signal characteristics are analyzed from the time and frequency domains, respectively. The cross-correlation analysis method based on biased estimation is adopted to obtain the flow rate. The verification experimental results showed that the measurement accuracy is 1.0-level when the flow velocity is above 0.5 m/s, and the measurement accuracy is 3.0-level when the flow velocity is in the range of 0.2 m/s to 0.5 m/s.

Unequal Distance Sampling Technique to Design Velocity-Type Respiratory Air Flow Transducer (속도 계측형 호흡기류센서 설계를 위한 비균등 샘플링 기법)

  • 김경아;이태수;차은종
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.5
    • /
    • pp.351-359
    • /
    • 2004
  • Velocity-type repisratory air flow transducer measures dynamic pressure converted from air velocity based on the we1l-known Bernoulli's principle. It requires multiple velocity sampling holes on the flow plane. Measurement error theoretica1ly estimated by computer simulation was demonstrated to significantly reduce by unequally locating the velocity sampling holes. The flow plane was divided into multiple equi-area rings and the sampling holes were located on the circles also equally dividing each ring's area, which decreased measurement error down to 1/5 of the simple equi-radius ring division method. Also, less than 1 % relative error was estimated with 4 or more sampling holes. The present technique was less sensitive by <1/2 to the velocity profile change compared to the euqi-radius sampling. Therefore, the present unequal distance velocity sampling technique should be of great use to design the structure of the velocity-type respiratory air flow transducer.

Forward-Looking Ultrasound Imaging Transducer : I. Analysis and Design (전향 초음파 영상 트랜스듀서 : I. 해석 및 설계)

  • Lee, Chan-Kil
    • The Journal of the Acoustical Society of Korea
    • /
    • v.14 no.2E
    • /
    • pp.73-86
    • /
    • 1995
  • The transducer section of the forward-looking ultrasound imaging catheter (FLUIC) consists of a circular piezoelectric element as a vibrator and a conical acoustic mirror as a perfect reflector. A small diameter piezoelectric transducer element is mounted on the side of a catheter's rotating shaft. The unique design of FLUIC provides the capability to form a two-dimensional image of a cross-section of vessel in front of the catheter, which is lacking in the present generation of intravascular ultrasound (IVUS) transducers, as well as a conventional side view image. The mirror configuration for the transducer section of the FLUIC is designed using an approximated ray tracing techniques. The diffraction transfer function approach [1] developed for the field prediction from primary sources is generalized and extended to predict the secondary diffraction characterstics from an acoustic mirror. The extended model is verified by simulation and experiment through a simple plane reflector and employed to analyzed the field characteristics of a FLUIC.

  • PDF

Design of Tightly Coupled INS/DVL/RPM Integrated Navigation System (강결합 방식의 INS/DVL/RPM 복합항법시스템 설계)

  • Yoo, Tae-Suk;Kim, Moon-Hwan;Yoon, Seon-Il;Kim, Dae-Joong
    • Journal of Ocean Engineering and Technology
    • /
    • v.33 no.5
    • /
    • pp.470-478
    • /
    • 2019
  • Because the global positioning system (GPS) is not available in underwater environments, an inertial navigation system (INS)/doppler velocity log (DVL) integrated navigation system is generally implemented. In general, an INS/DVL integrated system adopts a loosely coupled method. However, in this loosely coupled method, although the measurement equation for the filter design is simple, the velocity of the body frame cannot be accurately measured if even one of the DVL transducer signals is not received. In contrast, even if only one or two velocities are measured by the DVL transducers, the tightly coupled method can utilize them as measurements and suppress the error increase of the INS. In this paper, a filter was designed to regenerate the measurements of failed transducers by taking advantage of the tightly coupled method. The regenerated measurements were the normal DVL transducer measurements and the estimated velocity in RPM. In order to effectively estimate the velocity in RPM, a filter was designed considering the effects of the tide. The proposed filter does not switch all of the measurements to RPM if the DVL transducer fails, but only switches information from the failed transducer. In this case, the filter has the advantage of being able to be used as a measurement while continuously estimating the RPM error state. A Monte Carlo simulation was used to determine the performance of the proposed filters, and the scope of the analysis was shown by the standard deviation ($1{\sigma}$, 68%). Finally, the performance of the proposed filter was verified by comparison with the conventional tightly coupled method.

Design of A Narrow-Band Orthomode Transducer Operating at Ku-Band (Ku-대역 협대역 직교모드 변환기 설계)

  • Li Jun-Wen;Kim Jin-Young;Ko Han-Woong;Park Dong-Hee;Ahn Bierng-Chearl
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.12 s.91
    • /
    • pp.1123-1130
    • /
    • 2004
  • In this paper, a technique is presented f3r the design of a structurally simple narrow-band orthomode transducer (OMT) operating at 12/14 GHz frequency bands. The proposed OMT has such a structure that a horizontally polarized wave incident on the circular waveguide of the common port is directed to the rectangular waveguide of the straight port, while the vertically polarized wave is directed to the rectangular waveguide of the side port. Firstly methods are developed f3r designing individual parts of the OMT based on the waveguide theory and the theory of impedance matching. Secondly based on developed methods the whole OMT structure is designed using a commercial electromagnetic field analysis software. The validity of the proposed design technique is confirmed by fabricating and testing the designed OMT.

A Design of Transducer Interface Protocol for Context-aware Middleware (상황인식 미들웨어를 위한 트랜스듀서 인터페이스 프로토콜 설계)

  • Jang, Dong-Wook;Sohn, Surg-Won;Han, Kwang-Rok;Sun, Bok-Keun
    • Journal of the Korea Society of Computer and Information
    • /
    • v.16 no.9
    • /
    • pp.45-55
    • /
    • 2011
  • Context awareness technologies are based on efficient sharing of environment information of ubiquitous sensors in everyday life, and users require this awareness technologies to get quality of services. However, the application has been restricted due to its varieties of sensors and many different methods of communications. Therefore, IEEE 1451 standard has been published to interface between sensors and network layer. But it does not connect to a middleware because IEEE 1451 is for transducer standards. This paper presents a transducer and application interface protocol which connect to the context-aware middleware by defining a protocol to obtain context information using XML. We have implemented a bridge health monitoring system and railroad monitoring system in which different sensors and users' application are used to prove the efficacy of proposed interface protocols.

Design and Construction of the Acoustic Horn for Magnetostrictive Ultrasonic Transducer (자왜형 초음파 트랜스듀서용 도파봉의 설계 및 제작)

  • 강국진;노용래
    • The Journal of the Acoustical Society of Korea
    • /
    • v.20 no.6
    • /
    • pp.57-65
    • /
    • 2001
  • In this paper, we designed the acoustic horn for magnetostrictive ultrasonic transducers in a theoretical manner, and validity of the analysis was verified through comparison with the results of finite element analysis. Results of the two analysis methods showed good agreement with each other. The theoretical method can fairly quickly determine the horn length that satisfies given frequency specification, but also has the drawback that it is applicable only to the frequency range over the cut-off frequency. According to the results, the catenoidal horn can provide larger amplification than the exponential horn. It was also found that it is more desirable for the region having the catenoidal curvature to be as short as possible to achieve larger amplification of the transducer deformation. Based on the analysis results, a magneto-strictive transducer sample was fabricated and its performance was evaluated experimentally. The transducer has the resonance frequency of 19.3 ㎑ as well as the maximum SPL of 199 dB, and shows the omni-directional radiation pattern.

  • PDF

Piezoelectric Transducer for Ultrasonic Flaw Detector with High Performance (고성능 초음파 결함탐상기를 위한 압전변환기)

  • Jung, Jun Hwan;Jun, Ho Ik;Kim, Hyun-Sik;Kang, Seog Geun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.7
    • /
    • pp.1645-1652
    • /
    • 2013
  • In this paper, a new piezoelectric transducer for high performance ultrasonic flaw detector used in non-destructive test (NDT) is implemented. Here, the goals for some major characteristics such as piezoelectric strain constant and electro-mechanical coupling factor are fixed in advanced. Then, the parameters obtained by finite element analysis (FEA) are exploited to design and implement the piezoelectric transducer. As a result of experiments using manufactured samples, it is proved that the new PZT ceramics satisfy the goals very well. It has much improved impedance characteristic at the resonant frequency and generation of ultrasonic signals. In addition, ultrasonic flaw detector with the new transducer provides increased flaw detecting gain than the conventional one. Thus, it is considered that the new flaw detector contributes significantly to improve reliability of the NDT.

Design and Implementation of a Vibration Transducer based on PZT Multi-layered Actuator for Implantable Middle Ear Hearing Devices (PZT 적층 압전체 기반의 인공중이용 트랜스듀서 설계 및 구현)

  • Park, I.Y.;Jung, E.S.;Seong, K.W.;Kim, M.W.;Cho, J.H.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.1 no.1
    • /
    • pp.29-36
    • /
    • 2007
  • Recently, implantable middle ear hearing devices (IMEHDs) have been developed to overcome the problems of conventional hearing aids. In this paper, a piezoelectric floating mass transducer (PFMT) based on a PZT multi-layered actuator has been designed and implemented using the approximated mechanical vibration modeling for the PFMT and the analysis of vibration characteristics through the transformation into the equivalent electrical model. The implemented PFMT has been attached to the ossicle of a human cadaver's temporal bone and the in-vitro experiment has been performed. Through the experimental results, it has been verified that the PFMT applied into our developed implantable middle ear hearing device can be used for an IMEHD transducer.

  • PDF