• Title/Summary/Keyword: transducer assembly

Search Result 21, Processing Time 0.02 seconds

Development of a Ultrasound Probe for 3-D Ultrasonic Imaging (3차원 의료기기용 초음파진단기 프로브 개발)

  • Park, Jong-Soo;Kim, Seong-Rae;Nam, Yoon-Su
    • Journal of Industrial Technology
    • /
    • v.25 no.A
    • /
    • pp.87-93
    • /
    • 2005
  • Three-dimensional ultrasonic probes being applied to the medical imaging can be grouped into three depending on the scanning methods, which are a mechanical type system, a free-hand system, and 2D phased arrays system. A mechanical type scanner uses a mechanically driven transducer to acquire series of 2D plane images. By integrating these images, a 3-D medical image can be constructed. A motor driving mechanism is a conventional choice for mechanically driving a transducer assembly which picks the raw ultrasonic images up. In this paper we attempt to design a 3D ultrasonic probe which has a operating mechanism of s tilting 3-D scanning. The motion of a transducer assembly of the ultrasonic probe is analytically modelled. We propose a selection procedure for the diameter of a wire rope driving the transducer assembly and the size of torsional spring which gives an initial tension to wire ropes.

  • PDF

A Study on Development of Composite Ultrasonic Transducer Assembly with Drug Transfer Function (약물 이송기능을 갖는 복합구조 초음파 변환기 어셈블리 개발에 관한 연구)

  • Noh, Si-Cheol;Kim, Ju-Young;Yoo, Byeong-Cheol;Jung, Bong-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.5
    • /
    • pp.353-359
    • /
    • 2017
  • The sonophoresis, a representative low-intensity ultrasonic therapy, is a technique for delivering the drugs into the epidermis, dermis and skin appendages by using physical vibration and heat effects of the ultrasonic waves. Sonophoresis could increases the delivering and absorption efficiency of the drugs usually consisting of hydrophilic molecules and macromolecules. In addition, it has the advantage of being effective in delivering drugs with relatively large molecular sizes such as insulin or lipid. In this study, we proposed a multi-structure ultrasonic transducer assembly with a large-size single piezoelectric element and a drug delivery function at the treatment site for efficient sonophoresis treatment. Futhermore, a transducer assembly structure capable of raising and maintaining the temperature of the treatment site was proposed and evaluated for effectiveness. The transducer assembly proposed in this study is expected to improve the efficiency of sonophoresis by providing a constant amount of drug, and assisting drug delivery through heating the treatment site.

Contact Analysis on a Born-Holder Assembly for Wire Bonding (와이어 본더용 Horn-Holder Assembly의 접촉 해석)

  • Jang, Chang-Soo;Ahn, Geun-Sik;Kim, Young-Joon;Kwak, Dong-Ok;Boo, Seong-Woon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.10
    • /
    • pp.2008-2017
    • /
    • 2002
  • Joint structure of a transducer horn-holder assembly fur a wire bonder was examined through FEM contact analysis. A three dimensional modeling and analysis was carried out to survey the internal physics of this structure and to prove the accuracy of a computation compared to a measurement. After validation, a simple two dimensional model was built fur various parametric study considering the efficiency and speed of the computation. Several factors such as boundary conditions, a modeling boundary, mesh density and so on, were considered to obtain consistency with three dimensional analysis. An arc angle and a position of each holder boss were chosen as design parameters. A design of experiment was applied to find out an optimized design of the holder geometry. As a result, a guideline for holder boss design was suggested and main factors and their influence on stress concentration in the transducer horn were surveyed.

Bandwidth Improvement of a Multi-resonant Broadband Acoustic Transducer (다중 공진 광대역 음향변환기의 대역폭 개선)

  • Lee, Dae-Jae
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.50 no.5
    • /
    • pp.605-615
    • /
    • 2017
  • A multi-resonant broadband acoustic transducer with six Tonpilz elements operating at different resonant frequencies in a transducer assembly was fabricated, tested, and analyzed. A compensated transducer, modified by adding series inductance to the developed multi-resonant broadband transducer, was shown to provide improved bandwidth performance with a relatively more uniform frequency response compared with the uncompensated transducer. By controlling the series inductance, flat frequency response characteristics at two frequency bands were obtained over the range 38-52 kHz with 1.1 mH inductance and 50-60 kHz with 0.4 mH inductance. These results suggest that the operating frequency of the developed multi-resonant broadband transducer in a chirp echo sounder can be shifted to a different frequency band that is optimized according to the environment for more effective echo surveys of fishing grounds.

Development of smart transducer with embedded sensor for automatic process control of ultrasonic wire bonding

  • Or, Siu Wing;Chan, Helen Lai Wa;Liu, Peter Chou Kee
    • Smart Structures and Systems
    • /
    • v.1 no.1
    • /
    • pp.47-61
    • /
    • 2005
  • A ring-shaped lead zirconate titanate (PZT) piezoceramic sensor has been integrated with the Langevin-type piezoceramic driver of an ultrasonic wire-bonding transducer to form a smart transducer for in-situ measurement of three essential bonding parameters: namely, impact force, ultrasonic amplitude and bond time. This sensor has an inner diameter, an outer diameter and a thickness of 12.7 mm, 5.1 mm and 0.6 mm, respectively. It has a specifically designed electrode pattern on the two major surfaces perpendicular to its thickness along which polarization is induced. The process-test results have indicated that the sensor not only is sensitive to excessive impact forces exerted on the devices to be bonded but also can track changes in the ultrasonic amplitude proficiently during bonding. Good correlation between the sensor outputs and the bond quality has been established. This smart transducer has good potential to be used in automatic process-control systems for ultrasonic wire bonding.

마이크로 컴퓨터를 이용한 신경근 차단 감시장치의 개발에 관한 연구

  • 전계록;조진호
    • Journal of Biomedical Engineering Research
    • /
    • v.11 no.2
    • /
    • pp.257-268
    • /
    • 1990
  • A system has been developed for monitoring the effect of neuromuscular blocking frugs and the neuromuscular function during anesthesia and surgery. This system is composed of software and hardware, the latter are nerve stimulator, force transducer, interface board(preamplifier, filter, peripheral input/output) and personal computer (apple ll) , the former are programmed in ASSEMBLY and BASIC language. The nerve stimulator which is controlled by personal computer is capable of delivering single shocks at o.)Hz, train of four at 2Hz and tetanic stimulation at 30, 100, 200Hz. The response, adduction of the thumb, is sensed by the force transducer. The output of the force transducer Is amplified, filtered, converted digital signal and then processed by the per- sonal computer. The personal computer quantia4es twitch and traln of four tesponse and calculates the 74 ratio (Ta/Tl )between the first and fourth response of train of four. This ratio is used to estimate the level of the neuromuscular block. This system has reaserch potential for determining the effect of newer neuromuscular blocking drugs for comparlsion with presently used drugs of alternatively, for delerminig the effects of blocking drugs in altered physilogical states.

  • PDF

An Experimental Study on PWR Nuclear Fuel Assembly Vibration (경수로 핵연료집합체 진동의 실험적 고찰)

  • 장영기;김규태;조규종
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.82-87
    • /
    • 2003
  • Nuclear fuel with a big slenderness ratio is susceptible to flow-induced vibration under very severe conditions of high temperature, high flow and exposure to irradiation in nuclear reactor. The fuel assembly should, therefore, be designed to escape any resonance due to the vibration during the reactor operation, in particular, in case of the design changes. In addition, the amplitudes due to the grid vibration, the fuel rod vibration and the fuel assembly vibration should be minimized to reduce the grid-to-rod fretting wear. Fuel assembly vibration tests in air at room temperature and in water at high temperature have been performed to investigate fuel vibration behaviors. The frequency and damping during the test in air have been compared to those in water. Through the hydraulic test, the advanced assembly has been evaluated not to be susceptible to any resonance. In addition, the test data from the tests can be used to make fuel model and to evaluate grid-to-rod fretting wear.

  • PDF

A Study on the Characteristics of the Tube-to-Support Dynamic Impact Force Measurement Facility (튜브와 지지대 사이의 동적상호 충격력 측정장치 특성규명에 관한 연구)

  • 김일곤;박진무
    • Journal of KSNVE
    • /
    • v.5 no.1
    • /
    • pp.95-106
    • /
    • 1995
  • Flow-induced vibration in heat exchanger (or fuel rod) in nuclar power plant can cause dynamic interactions between tubes and tube supports resulting in fretting-wear. To increase the reliability and design life of heat exchanger components, design criteria that establish acceptable limits of vibration and minimize fretting wear are necessary. The fretting-wear rate is dependent upon material combination, contact configuration, environmental conditions and tube-to tube support dynamic interaction. It is demostrated that the fretting -wear rate correlates well with tube-to-support contact force or work rate. The tube-to-support dynamic interaction, which consists of dynamic contact forces and tube motion, is used to relate single-span wear data to real heat exchanger configurations consisting of multi-span tube bundles. This paper describes the test facility to measure tube-to-support dynamic impact force and reports its dynamic characteristics through the four impact tests - a force transduces independent and external impact tests, central ring inside impact test and additional cylinder impact test. Through the tests the impact parameter change dependent upon the material difference of impacting ball is studied, and the impact parameters of Force Transducer Assembly components are measured. And also the dynamic behavior of Force Transducer Assembly is analyzed. The force measurement technique herein is shown to provide a reasonable measure of dynamic contact forces.

  • PDF

Design of electromagnetic type transducer to drive round window with high efficiency (고효율 전자기형 정원창 구동 트랜스듀서의 설계)

  • Lee, Jang-Woo;Kim, Dong-Wook;Kim, Myoung-Nam;Cho, Jin-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.6
    • /
    • pp.449-455
    • /
    • 2010
  • Implantable middle ear hearing devices(IMEHDs) have being actively studied to overcome the problems of conventional hearing aids. Vibration transducer, an output devices of IMEHDs, is attached on the ossicular chain and transmits mechanical vibration to cochlea. This approach allows us to hear more clear sound because mechanical vibration is effective to transfer high frequency acoustics, but occurs some problems such as fatigue accumulation to ossicular chian and reduction of vibration displacement caused by mass loading effect. Recently, many studies for the round window stimulation are announced, because it does not cause such problems. It have been studied by older transducers designed for attaching on ossicular chain. In this paper, we proposed a new electromagnetic transducer which consists of two magnets, three coils and a vibration membrane. The magnet assembly, magnet coupled in opposite direction, were placed in the center of three coils, and the optimum length of each coil generating maximum vibrational force was calculated by finite element analysis(FEA). The transducer was implemented as the calculated length of each coil, and measured vibration displacement. From the results, it is verified the vibration displacement can be improved by optimizing the length of coils.

A Study on the Modeling and Control of High-Speed/High-Accuracy Position Control System (고속/정밀 위치제어시스템의 모델인 및 제어에 관한 연구)

  • Park, Min-Gyu;Han, Chang-Soo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.7 no.5
    • /
    • pp.399-406
    • /
    • 2001
  • This paper presents a dynamic modeling and a sliding mode controller for the high-speed/high-accuracy position control system. The selected target system is the wire bonder assembly which is used in the semiconductor assembly process. This system is a reciprocating one around the pivot point that consists of VCM(voice coil motor) as an actuator and transducer horn as a bonding tool. For the modeling elements, the sys-tem is divided into electrical circuit, magnetic circuit and mechanical system. Each system is modeled using the bond graph method and united into the full system. Two major aims are considered in the design of the controller. The first one is that the horn must track the given reference trajectory. The second one is that the controller must be realizable by using the DSP board. Computer simulation and experimental results show that the designed sliding mode controller provides better performance than the PID controller.

  • PDF