• Title/Summary/Keyword: track circuit current

Search Result 62, Processing Time 0.031 seconds

Study on Design of Rail Level Crossing System for Preventing from Non-Alarming Status Caused by Track Shunting Sensibility Errors (레일 단락감도 불량으로 발생하는 무경보 예방을 위한 건널목보안장치 설계)

  • Jang, Dong-Wan;Jeon, Tae-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.1
    • /
    • pp.160-166
    • /
    • 2010
  • Railroad level crossing systems are used to prevent train from collisions by informing pedestrians and vehicles of approaching trains on the level crossing. The current detection systems mostly use track-based electrical circuits to detect approaching trains. The making and breaking of the circuit when the train wheel passes along the track sends a signal to barriers that restrict access to the track. Unfortunately, this track-based signal system is vulnerable to malfunctions in certain situations. If the rail becomes rusted due to moisture, weather conditions, or infrequent use, the electrical circuit detection system could fail. Such a failure could lead to a train-vehicle or train-pedestrian collision. This paper suggests a replacement of the electrical circuit-based system with an infrared detection system. The research shows that an infrared detection system improves safety by reducing the frequency of detection failure of the alarming circuit to system.

A Train Locating Device Using the Current Phase Difference Upon Magnetic Field Variation (자기장 변화에 따른 전류 위상차를 이용한 열차 위치검지 장치)

  • Choi, Jae Sik;Kim, Baik;Rho, Sung Chan
    • Journal of the Korean Society for Railway
    • /
    • v.15 no.6
    • /
    • pp.604-608
    • /
    • 2012
  • Traditionally, the track circuits have been used for the purpose of train locating. However, the recent train control systems like a CBTC(Communications Based Train Control) do not utilize the track circuits to minimize the amount of ground signal devices. Therefore, there are increasing concerns over the system that can locate the position of train exactly without using the track circuits. Then, the contactless locating methods are added to ensure safety when the shunting sensitivity of the track circuit becomes low for the existing sections equipped with the track circuits. In this paper, a prototype of train locating device has been designed and tested, which utilizes the current phase difference upon magnetic field variation. The results show improved features of this method over the conventional track circuits method.

The Analysis of Trolley-Rail Short Circuit Current in a Single Track AT Feeding System (단선 AT 급전계통의 전차선-레일 단락 고장전류 분석)

  • Cho, Gyu-Jung;Ryu, Kyu-Sang;Lee, Hun-Do;Heo, Seung-Hun;Kim, Chul-Hwan;Kwon, Sung-Il;Kim, Cheol-Hwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.12
    • /
    • pp.1659-1665
    • /
    • 2015
  • In general, AT(Auto-transformer) is used to improve voltage sag and inductive interference in power lines and communication lines in AC electrical railway feeding system. Especially, Korean AT feeding system has different composition compared to other countries like Japan or France, so that it has some special characteristics. However, relays imported from other countries have been used in Korea, and settings of these relays should be modified and reflect distinct characteristics of Korean AT feeding system. Therefore, study about fault analysis based on modeled AT feeding system is important. In this paper, we modeled a single track AT feeding system by using PSCAD and analyzed fault current flow in case of trolley-rail short circuit fault. Finally, we presented current magnitude of each branch expressed by boosting current of AT.

A Study on the Improvement for a Defect Diagnosis of Track Circuit on HSL (고속선 궤도회로 결함진단을 위한 개선방안 연구)

  • Park, Ki-Bum;Lee, Tae-Hoon;Lee, Gi-Chun
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.1656-1664
    • /
    • 2007
  • This paper introduces a study of improvement for a defect diagnosis of the UM71C track circuit using on HSL. The track circuit on HSL has long operation section. Therefore, when the worker maintain, many times and efforts are spent. So, periodically, we have operated a inspection car. However, we don't know exactly the state changed of the inspection data when track circuit has defect. Actually, We fixed a sample area within operation section on HSL and performed the simulations for short circuit current that is reflected characteristic impedance and propagation factor. We compared the measuring data with the result of the simulation. Using verified simulation program, we estimated inspection data as the malfunction number and the change of capacity of compensation capacitor. These study need to secure of the safety as the train operation. Also, It needs to make a criteria of analysis for the maintenance through comparison simulation data and inspection data.

  • PDF

A study on surface resistivity of GFRP reinforced precast slab track (유리섬유보강 슬래브의 표면저항특성 고찰)

  • Moon, Do-Young;Zi, Goang-Seup;Lee, Seung-Jung;Kim, Yoo-Bong;Baek, In-Hyuk
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.2435-2438
    • /
    • 2011
  • Steel bar is used for as a reinforcing material in a concrete slab track. Bacuase the steel re-bar could provide passes for current transition, all the cross points of steel re-bars should be insulated by using plastic materials. This is due to the loss of signal intensity of track-circuit. In this study, GFRP bars are adopted in place of the traditional steel reinforcing bars for a concrete slab track to minimize the loss of the signal intensity. In order to evaluate the replacing effect on eletrical characteristic of slab track, measurements of surface resistivity are conducted on steel and GFRP reinforced precast slab tracks. In the results, the GFRP reinforced slab strack shows the higher resistivity than the steel reinforced slab track.

  • PDF

Wind Power Grid Integration of an IPMSG using a Diode Rectifier and a Simple MPPT Control for Grid-Side Inverters

  • Ahmed, Tarek;Nishida, Katsumi;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • v.10 no.5
    • /
    • pp.548-554
    • /
    • 2010
  • In this paper, a 1.5 kW Interior Permanent Magnet Synchronous Generator (IPMSG) with a power conditioner for the grid integration of a variable-speed wind turbine is developed. The power-conditioning system consists of a series-type 12-pulse diode rectifier powered by a phase shifting transformer and then cascaded to a PWM voltage source inverter. The PWM inverter is utilized to supply sinusoidal currents to the utility line by controlling the active and reactive current components in the q-d rotating reference frame. While the q-axis active current of the PWM inverter is regulated to follow an optimized active current reference so as to track the maximum power of the wind turbine. The d-axis reactive current can be adjusted to control the reactive power and voltage. In order to track the maximum power of the wind turbine, the optimal active current reference is determined by using a simple MPPT algorithm which requires only three sensors. Moreover, the phase angle of the utility voltage is detected using a simple electronic circuit consisting of both a zero-crossing voltage detecting circuit and a counter circuit employed with a crystal oscillator. At the generator terminals, a passive filter is designed not only to decrease the harmonic voltages and currents observed at the terminals of the IPMSG but also to improve the generator efficiency. The laboratory results indicate that the losses in the IPMSG can be effectively reduced by setting a passive filter at the generator terminals.

A Study on the improvement of Track Circuit measurement equipment for High speed Line (고속선 궤도회로 검측설비 개량을 위한 방안 연구)

  • Kwak, Woo-Hyun;Kim, Yong-Kyu;Lee, Jong-Woo
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.832-837
    • /
    • 2006
  • ATC facility manipulates ground-on-board information, which transmits speed limit, varying as wayside environments - safety facility, track gradient, inclination, bridge and tunnel and other factors, installed for safe operation of trains on wayside. Efficientiation and automatification of operation and maintenance is being realized, by measuring if there are any erroneous information, using a measuring car. In this paper, we study in priority the methods for measuring accurately distinctive properties of internal malfunctions of track circuits, the performance decrease of condensers, and the unbalance of return cables, which are actually required for functionality improvement of high-speed line signal measure facilities, by measuring the unbalance of return current given because of damaged factors of external track circuits.

  • PDF

Contact-less Power Supply Using Series-Parallel Rasonant Converter ($\cdot$병렬 공진형컨버터를 이용한 비접촉전원)

  • Kim E. S.;Goo D. H.;Kim J. M.;Kang D. H.;Shin B. C.;Kong Y. S.;Yang S. C.
    • Proceedings of the KIPE Conference
    • /
    • 2002.11a
    • /
    • pp.103-107
    • /
    • 2002
  • A contact-less power supply system (CPS) allows electrical energy to supply to mobile consumers without any electrical or mechanical contact. CPS works in the same principle as a transformer, with the track litz cable forming the primary circuit and the pickup as the secondary. The track power supply generates the high frequency alternating current in the track cable. The captured AC magnetic field generated by the track conductors produces electrical energy in the pickup coil and the pickup rectifier converts the high frequency AC power to DC while regulating the power to the load. This paper presents the theoretical analysis, simulation and experiment리 results of the series-parallel resonant converter working as contact-less power supply system.

  • PDF

A Study on the Effect of Cab Signal through Unbalance of the Traction Return Current (귀선전류의 불평형에 따른 차상신호에 미치는 영향에 관한 연구)

  • Lee, Tae-Hoon;Park, Ki-Bum;Sung, Soon-Uk
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.1694-1700
    • /
    • 2007
  • In the electrified section, both of return current and signal current are flowing in the same rail in common. But signal current shall be allowed to flow in the specific track circuit and not in the other circuit while the traction return current shall come back to power sub-station. This paper presents measuring system that use both sensor and antenna. The aim of the system is to achieve the difference in current between the two rails and the presence of trimming capacitors. In order to improve the transmission level, trimming capacitors are connected between the two rails at constant spacing. To maintain the balance of traction return current, rails of both sides may be jointed by the so-called SVPMM. The traction return current is sometimes unbalanced owing to the ill-contact of SVPMM. In this paper, we propose a diagnosis method based on a short-circuited current(Icc), trimming capacitors and traction return current measured by Korail inspection vehicles. Whether Icc is good or bad depends not only on the presence of trimming capacitors but also on the unbalance of the traction return current.

  • PDF

Effect Analysis of Classical Line TI-21 type Audio Frequency Track Circuit from KTX Sancheon Return Current Harmonics (KTX산천 귀선전류고조파가 일반선 TI-21형 AF궤도회로에 미치는 영향분석)

  • Choi, Jae Sik;Kim, Hie Sik;Park, Ju Hun;Kim, Bun Gon
    • Journal of the Korean Society for Railway
    • /
    • v.19 no.1
    • /
    • pp.38-45
    • /
    • 2016
  • The power transformation system of High Speed rolling stocks like KTX-Sancheon has shown excellent control capacities in the areas of riding comfortability, switching efficiency, safety and energy consumption due to technical developments in power-electronics, high speed & large scale integrated semiconductors and microprocessors. However, harmonics from IGBT, a high speed switching device used in the Convertor & Invertor equipment of rolling stocks have given rise to various problems in transformer substations, signaling systems, data transmission systems and facility monitoring systems. Especially, TI21 non-insulated track circuits have malfunctioned due to the influence of returning current harmonics which were generated at around of integer times of the number of power transformation equipment in the frequency domain. This paper, measures and analyzes various schemes to analyze the traveling path of the returning current harmonics generated due to the relationship between the rolling stocks and track circuits on site. Ultimately, theseschemes will be used to design high speed rolling stocks, AF track circuits and a common grounding network.