• Title/Summary/Keyword: trace phosphate ion

Search Result 11, Processing Time 0.027 seconds

Flotation-Concentration of Trace Phosphate Ion in Water Samples by $La(OH)_3$ Coprecipitation ($La(OH)_3$ 공침에 의한 물시료 중 흔적량 인산이온의 부선 농축)

  • Kim, Young-Sang;Park, Sang-Wan;Choi, Hee-Seon
    • Analytical Science and Technology
    • /
    • v.5 no.4
    • /
    • pp.425-431
    • /
    • 1992
  • The concentration and determination of trace phosphate ion was studied by $La(OH)_3$ coprecipitaiton. Phosphate ions in 1.0L samples were coprecipitated with lanthanium hydroxide at pH 9.5 adjusted with ammonia solution. The precipitates were floated with the aid of mixed surfactant(1:8 sodium oleate/sodium dodecyl sulfate) and nitrogen gas bubbles. The floated precipitate was collected in suction flask from the solution. The precipitate were washed with dil. ammonia solution and dissolved in sulfuric acid. The phosphate ion in the concentrated solution was finally determinated by UV/VIS spectrophotometry using the molybdenium blue method. The proposed method could be applied to the determination of phosphate ion in tap water and river water.

  • PDF

Fluorimetric Determination of Phosphate in Sea Water by Flow Injection Analysis

  • Motomizu, Shoji;Oshima, Mitsuko;Katsumura, Naoya
    • Analytical Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.843-848
    • /
    • 1995
  • A sensitive method for the determination of trace amounts of phosphate by fluorescence-quenching detection / FIA is proposed. The fluorescence of Rhodamine B(RB) was quenched with the formation of the ion associate of molybdophosphate with RB;${\lambda}_{ex}$ and ${\lambda}_{em}$ were 560nm and 580nm, respectively. A calibration graph was linear over the ranges from $10^{-8}$ to $3{\times}10^{-6}M$ of phosphate (~0.3~93ppb of phosphorus). The relative standard deviation was 1.2% with $8{\times}10^{-7}M$ phosphate solution and sampling rate was 15 samples / h. The proposed method was applied to the determination of phosphate in sea and river water samples.

  • PDF

Determination of Cyanide Ion in the Presence of Sulfide Ion by Differential Pulse Cathodic Stripping Voltammetry (시차펄스 음극벗김 전압전류법에 의한 황화이온의 존재하에서 시안화이온의 정량)

  • Park, Se Yeon;Kwon, Young Soon
    • Analytical Science and Technology
    • /
    • v.6 no.1
    • /
    • pp.47-55
    • /
    • 1993
  • The quantitative determination of trace cyanide ion in the presence of sulfide ion has been studied by addition of cupric ion using differential pulse Cathodic Stripping Voltammetry. The detection limit of cyanide ion in the presence of $5.0*10^{-5}M$ sulfide ion and $1.0*10^{-3}M$ cupric ion was $2.0*10^{-7}M$ in KCI-Phosphate buffer(pH=7.0) at accumulation potential -0.30V and accumulation time 3.0 min.

  • PDF

Development of Open Tubular Capillary Columns for Ion Chromatography (이온 크로마토그래피용 Open Tubular Capillary 컬럼의 개발)

  • Pyo, Dong Jin;Kim, Ho Hyun
    • Journal of the Korean Chemical Society
    • /
    • v.45 no.2
    • /
    • pp.143-148
    • /
    • 2001
  • In this study, open tubular capillary columns for ion charomatography were developed to analyze trace amount of ions in samples. When small I,D. capillary column length is 1.0~5.0 m. The capillary columns were made using fused silica capillary(I.D:50㎛) and DMEOHA latex particles. The new conductivity cell and suppressor were also developed and made for capillary column ion chromatography. When several anions(fluoride, nitrite, nitale,chlorate,phosphte, sulfate) were analyzed using these capillary columns. reproducible and good chromatograms were obtained.

  • PDF

Fe-doped beta-tricalcium phosphate; crystal structure and biodegradable behavior with various heating temperature (Fe 이온 치환 beta-tricalcium phosphate의 하소 온도에 따른 미세구조 및 분해 특성)

  • Yoo, Kyung-Hyeon;Kim, Hyeonjin;Sun, Woo Gyeong;Yoon, Seog-Young
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.30 no.6
    • /
    • pp.244-250
    • /
    • 2020
  • β-Tricalcium phosphate (β-TCP, Ca3(PO4)2) is a kind of biodegradable calcium phosphate ceramics with chemical and mineral compositions similar to those of bone. It is a potential candidate for bone repair surgery. To improve the bioactivity and osteoinductivity of β-TCP, various ions doped calcium phosphate have been studied. Among them, Iron is a trace element and its deficiency in the human body causes various problems. In this study, we investigated the effect of Fe ions on the structural variation, degradation behavior of β-TCP. Fe-doped β-TCP powders were synthesized by the coprecipitation method, and the heat treatment temperature was set at 925 and 1100℃. The structural analysis was carried out by Rietveld refinement using the X-ray diffraction results. Fe ions existed in a different state (Fe2+ or Fe3+) with different heat treatment temperatures, and the substitution sites (Ca-(4) and Ca-(5)) also changed with temperature. The degradation rate was fastest at Fe-doped β-TCP with heated at 1100℃. The cell viability behavior was also enhanced with the substitution of Fe ions. Therefore, the substitution of Fe ion has accelerated the degradation of β-TCP and improved the biocompatibility. It could be more utilized in biomedical devices.

Optimization of solid phase extraction and simultaneous determination of trace anions in concentrated hydrofluoric acid by ion chromatography (불산 중 극미량 음이온 분석을 위한 고상 추출법 및 이온크로마토그래프를 이용한 동시분석법 확립)

  • Yoon, Suk-Hwan;Jo, Dong-ho;Kim, Hyun-Ji;Shin, Ho-Sang
    • Analytical Science and Technology
    • /
    • v.29 no.5
    • /
    • pp.219-224
    • /
    • 2016
  • 불산 중 극미량 음이온의 고상추출과 이온크로마토그래프를 이용한 고감도 분석법이 개발되었다. 불산 중 불소이온이 고상에 의해 제거하였고 이어서 음이온 (F, CH3COO, Cl, Br, NO3, PO43−, SO42−)들이 이온크로마토그래프를 이용하여 연속적으로 분리하였다. 고상 추출법에 영향을 주는 각 인자들 (흡착제의 선택, 시료의 부피 및 pH, 용출 용액과 용출용액의 부피)을 결정하였으며 그 결과 흡착제로서 Oasis WAX 컬럼이 가장 우수하였고 1.0 mL의 시료부피, 용출용액으로 50 mM 초산암모늄염 5 mL가 분리능에서 가장 우수하였다. 개발한 방법에 의한 음이온 (Cl, Br, NO3, PO43−, SO42−)들의 방법검출한계는 25 % 불산용액 (w/w) 중에 0.04~0.30 µg/L의 범위를 보였고 정밀도는 20.0와 40.0 µg/L의 농도에서 5 % 이내를 보였다. 한 제조회사에 의한 25 % 불산 중 음이온의 4.2에서 47.5 µg/L의 범위로 모두 검출되었다. 이 방법은 시험절차가 간단하고, 재현성 및 감도가 좋아서 반도체회사에서 불산 중 음이온 불순물을 정도 관리하는데 매우 유용한 방법이 될 것으로 판단된다.

The Study on Secondary Pollutants of $PM_{10}$ in Pocheon (포천지역에서 측정한 $PM_{10}$중 2차 생성입자에 관한 연구)

  • Park Tae-Sool
    • Journal of environmental and Sanitary engineering
    • /
    • v.20 no.4 s.58
    • /
    • pp.9-20
    • /
    • 2005
  • The purpose of the study was characteristics of secondary pollutants of $PM_{10}$ collected in pocheon between August 2002 and June 2003. The ambient concentrations of $PM_{10}$ mass, 9 water-soluble anions and cations, and 13 bulk composition trace elements were determined from filter samples collected by $PM_{10}$ high volume air sampler(UV-15H, Graseby-Anderson Co., USA). During this period average $PM_{10}$ mass concentration was $83.8{\mu}g/m^3(49.8{\mu}g/m^3\~111.6{\mu}g/m^3)$ in Pocheon. Mechanism for transformation of secondary pollutants by soluble ion components is divided into two categories; $NaNO_3$ type by the reaction of sea salt and $HNO_3$ in the atmosphere, and nitrate salt or phosphate salt type such as $(NH_4)_2SO_4,\;NH_4NaSO_4,\;and\;(NH_4)_2SO_4(2NH_4O_3)$.

Studies on Analysis of Gallium and Indium in Zinc Ores by Inductively Coupled Plasma Atomic Emission Spectrometry (유도결합 플라즈마 원자방출 분광법에 의한 아연광 중 Ga 및 In의 분석에 관한 연구)

  • Hwang, Youn-Ok;Sim, Sang-Kwon;Sung, Hack-Je;Yang, Myung-Kwon
    • Analytical Science and Technology
    • /
    • v.6 no.1
    • /
    • pp.131-139
    • /
    • 1993
  • The separation of gallium and indium from the matrix elements such as zinc and other ions, especially form Fe(III) ion was studied for the determination of trace level of them in zinc ores and zinc blendes by inductively coupled plasma atomic emission spectrometry(ICP-AES). Gallium and indium were extracted from the sample solution with a solvent of tributyl phosphate(TBP). The type and concentration of acid, interferences of other ions, the ratio of aqueous phase to organic phase, TBP concentration, sripping efficiency were optimized for the effective extraction. Gallium and indium were separated from other ions in the 5N hydrochloric acid solution of the samples by the extraction with 100% TBP. In this time, Fe(III) was reduced to Fe(II) with hydroxylamine hydrochloride to prevent its coextraction prior to the main extraxtion. After stripped from organic phase by the back-extraction with 0.02N HCl, they were determined in the aqueous phase by ICP-AES. This method was known to be quantitative from the overall extraction of more than 95%.

  • PDF

Removal of Alkali Metal Ion using Inorganic Ion Exchanger (무기이온교환제를 이용한 알카리 금속이온 제거)

  • Ha, Ji-Won;Yi, Kwang Bok;Lee, Si Hyun;Rhee, Young-Woo;Kim, Jong-Nam
    • Korean Chemical Engineering Research
    • /
    • v.46 no.2
    • /
    • pp.423-429
    • /
    • 2008
  • Currently, Ash-free clean coal producing process by solvent extraction is under development. The produced ash-free clean coal can be directly combusted in a gas turbine which results in substantial improvement of power generation efficiency. However, the clean coal produced by the solvent extraction still contain trace amount of alkali metal which may cause corrosion on turbine blades during the direct combustion. In present work ${\alpha},{\beta}$-metal (Zr and Ti) phosphates and H-Y zeolite were synthesized and their ion exchange characterizations were investigated for the application on alkali metal removal for clean coal production. $Na^+$ ion removal capacities of the metal phosphates and H-Y zeolite were measured and compared in both aqueous solution (100 ppmw, $Na^+$) and coal dissolved N-methyl-2-pyrrolidone (NMP, 12 ppmw $Na^+$) at elevated temperature. In aqueous solution, the ${\beta}$ form metal phosphates showed very high ion exchange capacities compared to ${\alpha}$ form. ${\beta}$ form metal phosphates also showed higher $Na^+$ removal capacities than H-Y zeolite. In ion exchange medium of NMP, all the ${\alpha}$ form metal phosphates showed over 90% of $Na^+$ ion removal efficiency in the temperature range of 200 to 400 while that of H-Y zeolite decreased as a half when the temperature was over 350. In addition, the regenerated metal phosphates by acid treatment showed no sign of degradation in $Na^+$ removal efficiency. Among the metal phosphates used, $Zr_{0.75}Ti_{0.25}(HPO_4)_2$ showed the best performance in $Na^+$ removal and is expected to be the most suitable inorganic ion exchanger for the alkali metal removal process.

Analysis of Methamphetamine and Amphetamine in Oral Fluid of Eleven Drug Abusers (마약남용자 11명의 타액 중 메스암페타민의 분석)

  • Kim, Eun-Mi;Lee, Ju-Seon;Choi, Hye-Young;Choi, Hwa-Kyung;Chung, Hee-Sun
    • YAKHAK HOEJI
    • /
    • v.52 no.6
    • /
    • pp.419-425
    • /
    • 2008
  • A qualitative and quantitative analytical method was developed for detection of methamphetamine (MA) and its main metabolite amphetamine (AM) in oral fluid. Oral fluids of eleven drug abusers were provided by Police, specimens were collected by stimulation with a cotton swab treated with 20 mg of citric acid ($Salivette^{(R)}$; Sarstedt, USA). As the preliminary test, oral fluid samples were screened for amphetamines by Fluorescence Polarization Immunoassay (TDxFLx, Abbott Co.). Extraction for MA was performed using solid-phase extraction (SPE) by $RapidTrace^{TM}$ (Zymark, USA) with mixed mode cation exchange cartridge, CLEAN $SCREEN^{(R)}$ (130 mg/3 ml, UCT) after dilution with phosphate buffer. Samples were evaporated and derivatized by pentafluoropropionic acid anhydride (PFPA). Quantitation of MA and AM was performed by gas chromatography-mass spectrometry (GC-MS) using selective ion monitoring (SIM), the quantitation ions were m/z 204 (MA), 208 (MA-$D_5$), 190 (AM) and 194 (AM-$D_5$). The selectivity, linearity of calibration, limit of detection (LOD) and quantification (LOQ) within- and between day precision, accuracy and recoveries were examined as parts of the method validation. All oral fluid samples gave positive results to immunoassay for MA (cut-off level, 50 ng/ml as d-amphetamine). Concentrations of MA and AM by GC-MS in eleven samples were ranged 104.2${\sim}$4603.3 ng/ml and 32.4${\sim}$268.6 ng/ml, respectively. Extracted calibration curves of MA and AM were linear over the two concentration range of 1${\sim}$100 and 50${\sim}$1000 ng/ml with correlation coefficient of above 0.999. LOQ of MA and AM was 1 and 3 ng/ml, respectively. The intraand inter-day run precisions (CV) for MA and AM were less than 10%, and the accuracies (bias) for MA and AM were also less than 10% at the two different concentrations 5 and 100 ng/ml at low calibration range, 50 and 1000 ng/ml at high calibration range. The absolute recoveries of MA and AM at low and high calibration ranges were more than 82% and 75%, respectively. In this study the qualitative and quantitative analytical method of MA in oral fluid was established. Oral fluid testing may detect drug use in past hours because of its shorter detection window than urine, and be useful in post-accident situations. So oral fluids will be most useful for testing drug abuse in the driving under the influence of drug (DUID) as the alternative specimens of urine.