• Title/Summary/Keyword: trabecular bone

Search Result 310, Processing Time 0.032 seconds

Differential effects of jump versus running exercise on trabecular bone architecture and strength in rats

  • Ju, Yong-In;Choi, Hak-Jin;Ohnaru, Kazuhiro;Sone, Teruki
    • Korean Journal of Exercise Nutrition
    • /
    • v.24 no.1
    • /
    • pp.1-8
    • /
    • 2020
  • [Purpose] This study compared differences in trabecular bone architecture and strength caused by jump and running exercises in rats. [Methods] Ten-week-old male Wistar rats (n=45) were randomly assigned to three body weight-matched groups: a sedentary control group (CON, n=15); a treadmill running group (RUN, n=15); and a jump exercise group (JUM, n=15). Treadmill running was performed at 25 m/min without inclination, 1 h/day, 5 days/week for 8 weeks. The jump exercise protocol comprised 10 jumps/day, 5 days/week for 8 weeks, with a jump height of 40 cm. We used microcomputed tomography to assess microarchitecture, mineralization density, and fracture load as predicted by finite element analysis (FEA) at the distal femoral metaphysis. [Results] Both jump and running exercises produced significantly higher trabecular bone mass, thickness, number, and fracture load compared to the sedentary control group. The jump and running exercises, however, showed different results in terms of the structural characteristics of trabecular bone. Jump exercises enhanced trabecular bone mass by thickening the trabeculae, while running exercises did so by increasing the trabecular number. FEA-estimated fracture load did not differ significantly between the exercise groups. [Conclusion] This study elucidated the differential effects of jump and running exercise on trabecular bone architecture in rats. The different structural changes in the trabecular bone, however, had no significant impact on trabecular bone strength.

Classification and visualization of primary trabecular bone in lumbar vertebrae

  • Basaruddin, Khairul Salleh;Omori, Junya;Takano, Naoki;Nakano, Takayoshi
    • Advances in biomechanics and applications
    • /
    • v.1 no.2
    • /
    • pp.111-126
    • /
    • 2014
  • The microarchitecture of trabecular bone plays a significant role in mechanical strength due to its load-bearing capability. However, the complexity of trabecular microarchitecture hinders the evaluation of its morphological characteristics. We therefore propose a new classification method based on static multiscale theory and dynamic finite element method (FEM) analysis to visualize a three-dimensional (3D) trabecular network for investigating the influence of trabecular microarchitecture on load-bearing capability. This method is applied to human vertebral trabecular bone images obtained by micro-computed tomography (micro-CT) through which primary trabecular bone is successfully visualized and extracted from a highly complicated microarchitecture. The morphological features were then analyzed by viewing the percolation of load pathways in the primary trabecular bone by using the stress wave propagation method analyzed under impact loading. We demonstrate that the present method is effective for describing the morphology of trabecular bone and has the potential for morphometric measurement applications.

Correlation Among Permeability, Apparent Density, And Porosity of Human Lumbar Vertebral Trabecular Bone (인체 요추해면골의 배류계수, 겉보기밀도, 공극비 사이의 상관관계에 관한 연구)

  • 홍정화;강신일
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.4
    • /
    • pp.333-338
    • /
    • 1997
  • Abnormal intraosseous flow and pressure in trabecular bone could cause various pathological conditions such as osteonecrosis and osteoarthritis. Characteristics of intraosseous fluid flow and pressure generation in porous trabecular bone can be significantly affected by the permeability. Factors which determine the permeability could be the porosity and apparent density of trabecular bone. However, there is little data on the permeability and the relationship among the permeability. porosity, and apparent density of trabecular bone. In this study. the permeability. porosity, and apparent density of human lumbar vertebral trabecular bone were experimentally measured. Also, a power relationship among the permeability, porosity, and apparent density was investigated to understand effects of the porosity and apparent density variations on the permeability of trabecular bone based on Kozeny-Carman equation. A near linear relationship between intraosseous fluid flow and time indicated that the fluid phase flowed through the pores in trabecular bone is governed by the permeability. The permeability of trybecular bone was found to have a significant power relationship with the porosity and apparent density (r: 0.84 and $\textit{p}$< 0.0005). The power relationship could be useful to determine the permeability of trybecular bone after measuring the apparent density and porosity.

  • PDF

Estimation of Viscoelastic Properties of Trabecular Bone Using An Inverse Method (역추기법을 이용한 해면골의 점탄성 특성 해석)

  • Kang, Shin-Ill;Lee, Won-Hee;Hong, Jung-Hwa
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.3
    • /
    • pp.211-216
    • /
    • 1997
  • An inverse method with regularization has been developed to determine the viscoelastic properties of trabecular bone. A series of stress relaxation experiments were performed under the condition of uniaxial compression stress state. Optimization has been formulated within the framework of nonlinear least-squares and a modified Gauss-Newton method with a zeroth-order regularization technique. The stress relaxation behavior of trabecular bone was analyzed using a standard viscoelastic model. The present study clearly shows that trabecular bone exhibits typical viscoelastic stress relaxation behavior, and the obtained material parameters well represent the viscoelastic behavior of trabecular bone.

  • PDF

A Study on the trabecular change of Femur according to $17{\beta}-Estradiol$ Dosage in Ovariectomized Rat (난소 절제된 백서에서 에스트로젠 투여용량에 따른 대퇴골주 변화에 대한 연구)

  • Kim, Seong-Joo;Kim, Kyung-Wook;Lee, Jae-Hoon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.22 no.2
    • /
    • pp.155-163
    • /
    • 2000
  • Osteoporosis is the consequence of an imbalance between osteoclastic and osteoblastic activity, coupled with an increased rate of bone turnover observed with menopause. Estrogen is generally considered to maintain bone mass through suppression of bone resorption. The purpose of this study was to evaluate the rat femoral trabecular change not only in the deficiency of estrogen but also in the administration of estrogen following ovariectomy(OVX). 30 female Sprague-Dawley rats were subjected to bilateral OVX or sham surgery(control). Groups of OVX were divided into 4 groups. The first group was injected daily with vehicle alone for 20 days after 20 weeks following OVX. The additional groups of OVX was injected daily with low, medium, or high doses of $17{\beta}-estradiol$(10, 25 or $50{\mu}g/kg$ BW, respectively). All rats were sacrified 23 weeks after OVX, and their femur were processed for H&E, MT stain and histomorphometry. The results were as follows; 1. In the histomorphometric analysis, the trabecular bone volume/tissue volume, trabecular thickness and trabecular seperation were respectively $31.2{\pm}8.3%$, $54.3{\pm}4.8{\mu}m$ and $280.7{\pm}16.4{\mu}m$ in vehicle treated OVX group and $48.6{\pm}7.3%$, $90.4{\pm}4.5{\mu}m$ and $126.3{\pm}5{\mu}m$ in sham operation group, and they showed statistical significance compare to control group. 2. The trabecular bone volume/tissue volume, trabecular thickness and trabecular separation were respectively $44.4{\pm}4.3%$, $109.5{\pm}12.3{\mu}m$ and $94.9{\pm}8.5{\mu}m$ in low doses of $17{\beta}-estradiol$ injected group and they showed statistical significance compare to OVX group. 3. The trabecular bone volume/tissue volume, trabecular thickness and trabecular separation were respectively $44.4{\pm}4.3%$, $109.5{\pm}12.3{\mu}m$ and $94.9{\pm}8.5{\mu}m$ in medium doses of $17{\beta}-estradiol$ injected group and they showed statistical significance compare to OVX group, but they didn't show statistical significance compare to low doses of $17{\beta}-estradiol$ injected group. 4. The trabecular bone volume/tissue volume, trabecular thickness and trabecular separation were respectively $46.4{\pm}4.5%$, $154.4{\pm}13.2{\mu}m$ and $113.7{\pm}12.8{\mu}m$ in high doses of $17{\beta}-estradiol$ injected group and they also showed statistical significance compare to OVX group, but they didn't show statistical significance compare to other experimental groups. From the above results, metaphyseal bone formation was markedly reduced in OVX rate but treatment of OVX rats with $17{\beta}-estradiol$ resulted in normalization of femur trabecular bone volume. But they didn't show statistical significance the effect of bone formation according to the dose dependency.

  • PDF

The Mechanical Characteristics of Osteoporotic Vertebral Trabecular Bone Models and its Hormone Treatment Models using 3D Micro-FE Analysis (3 차원 미세 유한요소모델을 이용한 골다공증 해면골과 호르몬 치료 모델의 기계적 특성 분석)

  • 우대곤;김한성;유용석
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.1278-1281
    • /
    • 2004
  • Several workers reported the relationship between osteoporosis and age-related reductions in the BV/TV (bone volume fraction) of vertebral trabecular bones. However, there were few micro finite element (micro-FE) models to account for the treatments of the osteoporotic trabecular bone. In the present study, micro-FE models of osteoporotic and hormone-treated bone models were constructed to analyze the effect of specimen location and boundary condition on mechanical characteristics of hormone treatment model for osteoporotic trabecular bone. Top and bottom sections of specimens were also investigated individually to study the effect of specimen location. Hormone-treated models were allowed to have the same relative BV/TV (13.4%) as that used in models of previous researchers. The present study reported the elastic and plastic characteristics of the osteoporosis and hormone-treated bone models. In the present study, in-situ boundary condition was applied to the simulated compression tests for in-vivo condition of vertebral trabecular bone. The present study indicated that the hormone therapy was likely to improve the mechanical characteristics of osteoporotic bones and the mechanical characteristics of vertebral trabecular bone specimen were dependent on the captured location and boundary condition.

  • PDF

Three-dimensional microstructure of human alveolar trabecular bone: a micro-computed tomography study

  • Lee, Ji-Hyun;Kim, Hee-Jin;Yun, Jeong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.47 no.1
    • /
    • pp.20-29
    • /
    • 2017
  • Purpose: The microstructural characteristics of trabecular bone were identified using micro-computed tomography (micro-CT), in order to develop a potential strategy for implant surface improvement to facilitate osseointegration. Methods: Alveolar bone specimens from the cadavers of 30 humans were scanned by high-resolution micro-CT and reconstructed. Volumes of interest chosen within the jaw were classified according to Hounsfield units into 4 bone quality categories. Several structural parameters were measured and statistically analyzed. Results: Alveolar bone specimens with D1 bone quality had significantly higher values for all structural parameters than the other bone quality categories, except for trabecular thickness (Tb.Th). The percentage of bone volume, trabecular separation (Tb.Sp), and trabecular number (Tb.N) varied significantly among bone quality categories. Tb.Sp varied markedly across the bone quality categories (D1: $0.59{\pm}0.22mm$, D4: $1.20{\pm}0.48mm$), whereas Tb.Th had similar values (D1: $0.30{\pm}0.08mm$, D4: $0.22{\pm}0.05mm$). Conclusions: Bone quality depended on Tb.Sp and number-that is, endosteal space architecture-rather than bone surface and Tb.Th. Regardless of bone quality, Tb.Th showed little variation. These factors should be taken into account when developing individualized implant surface topographies.

Feasibility of a Nonlinear Acoustic Method for the Assessment of Bone Status and Osteoporosis in Trabecular Bone

  • Lee, Kang Il
    • Journal of the Korean Physical Society
    • /
    • v.73 no.12
    • /
    • pp.1849-1854
    • /
    • 2018
  • The present study aims to investigate the feasibility of using a simple nonlinear acoustic method for the assessment of bone status and osteoporosis in trabecular bone. Correlations of linear and nonlinear ultrasound parameters with the apparent bone density were obtained in 32 bovine femoral trabecular bone samples. Highly significant positive correlations were observed between the apparent bone density and the two linear ultrasound parameters, the speed of sound (SOS) and the normalized broadband ultrasound attenuation (nBUA), with Spearman's correlation coefficients of r = 0.85 and 0.77. In contrast, the apparent bone density was found to be negatively correlated with the nonlinear ultrasound parameter introduced in the present study, the logarithmic difference between the power spectrum levels of the fundamental frequency and the second harmonic (PSL1-PSL2), with the highest correlation coefficient of r = -0.92. These results suggest that the PSL1-PSL2, in addition to the SOS and the nBUA, may be useful for the assessment of bone status and osteoporosis.

Influence of Cortical Endplates on Ultrasonic Properties of Trabecular Bone (피질골판이 해면질골의 초음파 특성에 미치는 영향)

  • Kim, Yoon Mi;Lee, Kang Il
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.35 no.2
    • /
    • pp.103-111
    • /
    • 2015
  • The present study investigated the influence of thick cortical endplates on the ultrasonic properties of trabecular bone in a femur with a high fracture risk. Twelve trabecular bone samples were prepared from bovine femurs, and acrylic plates with thicknesses of 1.25, 1.80, and 2.75 mm were manufactured to simulate the cortical endplates using acrylic with a density and a sound speed similar to cortical bone. Although the thickness of the acrylic plates attached to the two sides of the trabecular bone increased, high correlations were observed between the speed of sound and the apparent bone density of the trabecular bone, with Pearson's correlation coefficients of 0.80-0.86. High correlations were also observed between the attenuation coefficient at 0.5 MHz and the apparent bone density of the trabecular bone, with Pearson's correlation coefficients of 0.84-0.91. These results suggest that the speed of sound and attenuation coefficient at a specific frequency measured in a femur with relatively thick cortical endplates compared to the calcaneus could be used as indices for predicting the bone mineral density of the femur.