• Title/Summary/Keyword: toxicity monitoring

Search Result 203, Processing Time 0.027 seconds

Toxicity Monitoring of Endocrine Disrupting Chemicals (EDCs) Using Freeze-dried Recombinant Bioluminescent Bacteria

  • Kim, Sung-Woo;Park, Sue-Hyung;Jiho Min;Gu, Man-Bock
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.5 no.6
    • /
    • pp.395-399
    • /
    • 2000
  • Five different freeze-dried recombinant bioluminescent bacteria were used for the detection of cellular stresses caused by endocrine disrupting chemicals. These strains were DPD2794 (recA::luxCDABE), which is sensitive to DNA damage, DPD2540 (fabA::luxCDABE), sensitive to cellular membrane damage, DPD2511 (katG::luxCDABE), sensitive to oxidative damage, and TV1061 (grpE::luxCDABE), sensitive to protein damage. GC2, which emits bioluminescence constitutively, was also used in this study. The toxicity of several chemicals was measured using GC2. Damage caused by known endocrine disrupting chemicals, such as nonyl phenol, bisphenol A, and styrene, was detected and classified according to toxicity mode, while others, such as phathalate and DDT, were not detected with the bacteria. These results suggest that endocrine disrupting chemicals are toxic in bacteria, and do not act via an estrogenic effect, and that toxicity monitoring and classification of some endocrine disrupting chemicals may be possible in the field using these freeze-dried recombinant bioluminescent bacteria.

  • PDF

36hrs Continuous Monitoring Methodology for Effluent and Receiving Water Quality (하천 수질에 대한 36시간 연속 모니터링 기법 연구)

  • 박정규;정홍배;문성환;류태권;류제영;황인영
    • Environmental Analysis Health and Toxicology
    • /
    • v.16 no.4
    • /
    • pp.153-159
    • /
    • 2001
  • The main point source of pollution of the Keumho river in Taegu, Korea, stems from waste from the areas of industrial complexes . Although it is widely accepted that pollutants in waste water negatively effects general water quality, it is difficult to evaluate the effluent effect because of varying conditions in ambient water and inconclusive knowledge of causative pollutants. To analyze the water in relation to the industrial effluent in the area, pH. temperature, conductivity, and Microtox toxicity of various river samples were measured. Water samples were collected every 2 hours for 36 hours from Keumho river and Dalseo stream. Data from continuous monitoring for 36 hours showed that effluent in Keumho river originated from Dalseo stream, which is near adjacent to industrial complexes. Change in toxicity and other factors tested during the 36 hours indicated that continuous monitoring was necessary for a satisfactory effluent toxicity test Furthermore, in addition to water quality monitoring, it was concluded that sediment toxicity also needed to evaluate effluent effects.

  • PDF

Toxicity Monitoring of River Sediments in the Geum River Basin using Daphnia magna and Moina macrocopa (Daphnia magna와 Moina macrocopa를 이용한 금강수계 하천퇴적물 생태독성 모니터링)

  • Cho, Hyeyoon;Yoo, Jisu;Han, Youngseok;Han, Taejun;Kim, Sanghun;Jung, Jinho
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.6
    • /
    • pp.1000-1007
    • /
    • 2010
  • In this study, toxicity monitoring of sediments collected from 25 stations in the Geum river basin was conducted using Daphnia magna and Moina macrocopa. According to the results of acute toxicity tests (immobilization and mortality) of organic extracts of semdiments, Miho stream showed much less toxicity than Gap and Nonsan streams. In particular, significant toxicity was observed in both species for St.15 and St.16 sediment samples that passed through Deajeon city as a branch of Gap stream. For Nonsan stream, St.23 sediment showed high toxicity toward M. macrocopa. This site seemed to be affected by upper agricultural industrial complex. Additionally, M. macrocopa showed a higher sensitivity than D. magna for organic extracts of sediments. In the case of toxicity tests using sediment pore water and aqueous extracts, only pore water of St.27 sediment was toxic against D. magna. Toxicity identification evaluation showed that hydrogen sulfide was likely a major toxicant in the pore water.

Biological Evaluation for Characteristics of Leachate Toxicity from Municipal Solid Waste Landfill (생물학적 방법에 의한 도시생활폐기물 매립지의 침출수 독성특성 평가)

  • 황인영;류경무
    • Environmental Analysis Health and Toxicology
    • /
    • v.11 no.1_2
    • /
    • pp.31-39
    • /
    • 1996
  • Leachate from municipal solid waste (MSW) landfill, effluent from leachate treatment plant, and ground water sample from a monitoring well near landfill site were tested for an acute toxicity. Microtox toxicity test was used for testing the acute toxicity of leachate and other samples. EC$_{50}$ values which a concentration of pollutant for reducing 50% light output from luminescent bacteria, Photobacterium phosphoreum were determined to assess the toxicity of pollutants as well as the relative toxicity. In addition, characteristics of leachate were studied and compared to those of phenol and pentachlorophenol (PCP) which are typical aquatic toxic pollutants. For leachate, EC$_{50}$ for 30 min incubation was 10.8%, while for phenol and PCP, 46 ppm and 1.2 ppm, respectively. the relative toxicity of treated leachate by in situ aeration with activated sludge was reduced to more than 75% of toxicity of the untreated leachate. Microtox toxicity test was failed to figure out EC$_{50}$ values for groundwater from a monitoring well since the relative toxicity of the unconcentrated sample was too low to estimate EC$_{50}$. Addition of activated carbon to leachate was reduced the relative toxicity. The reduction Pattern of the relative toxicity of leachate by mechanical aeration was similar to that of PCP, but different from that of phenol. These findings suggest that the toxicity of leachate may come from PCP-like toxic compounds rather than phenol-like one. In conclusion, the process of aeration with activated sludge might be very important to reduce the environmental toxicity of leachate. And Microtox test could be a reasonable bioassay for screening and monitoring the environmental toxicity of leachate from municipal solid waste landfill as well as for determining the reduction efficiency of the leachate toxicity by various treatment processes in leachate treatment plant.

  • PDF

Cadmium Toxicity Monitoring Using Stress Related Gene Expressions in Caenorhabditis elegans

  • Roh, Ji-Yeon;Park, Sun-Young;Choi, Jin-Hee
    • Molecular & Cellular Toxicology
    • /
    • v.2 no.1
    • /
    • pp.54-59
    • /
    • 2006
  • The toxicity of cadmium on Caenorhabditis elegans was investigated to identify sensitive biomarkers for environmental monitoring and risk assessment. Stress-related gene expression were estimated as toxic endpoints Cadmium exposure led to an increase in the expression of most of the genes tested. The degree of increase was more significant in heat shock protein-16.1, metallothionein-2, cytochrome p450 family protein 35A2, glutathione S-transferase-4, superoxide dismutase-1, catalase-2, C. elegans p53-like protein-1, and apoptosis enhancer-1 than in other genes. The overall results indicate that the stress-related gene expressions of C. elegans have considerable potential as sensitive biomarkers for cadmium toxicity monitoring and risk assessment.

Continuous Water Toxicity Monitoring Using Immobilized Photobacterium phosphoreum

  • Kim, Se-Kwon;Lee, Baek-Seok;Lee, Jeong-Gun;Seo, Hyung-Joon;Kim, Eun-Ki
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.8 no.2
    • /
    • pp.147-150
    • /
    • 2003
  • Water toxicity monitoring based on the continuous cultivation of Photobacterium phorphoreum is presented. Normally, after 10 days of operation, a dark variant, which emits no light, appears and dominates the population, resulting in a rapid decrease in bioluminescence. Therefore, to overcome this problem, a fluidized-bed reactor is used in which alginate-immobilized cells are grown and leaking cells are continuously released into the effluent Experimental results revealed that the dominance of dark variants was suppressed inside the immobilized beads, thereby mitigating the rapid loss of bioluminescence. Plus, a high dilution rate (1.2 h$\^$-1/) prevented the occurrence of other microbial contamination in the reactor The concentration and bioluminescence of the released cells were sufficient to measure the water toxicity for more than 4 weeks.

Gene Expression Profiling in the Nematode Caenorhabditis elegans, as a Potential Biomarker for Soil Ecotoxicology (잠재적 생체지표 발굴을 위한 토양선충 Caenorhabditis elegans에서의 유전자 발현 연구)

  • Roh, Ji-Yeon;Choi, Jin-Hee
    • Environmental Analysis Health and Toxicology
    • /
    • v.25 no.1
    • /
    • pp.1-10
    • /
    • 2010
  • Monitoring toxicity levels in specific biological compartments is necessary to evaluate the ecotoxicological risk associated with soil environmental pollution. Gene expression, as potential biomarker, is increasingly used as rapid early warning systems in environmental monitoring and ecological risk assessment procedures. Various representative species are currently used for the purpose of assessing soil toxicity, however, investigations on toxicological assessments using endpoint based on gene-level have been limited. In this review, we will present the current trends in organisms and endpoints used in soil toxicity study and report gene expression related to toxicity using soil organism, and C. elegans as promising organisms for this approach.

Application of a Microbial Toxicity Assay for Monitoring Treatment Efficiency of Pentachlorophenol in Water using UV Photolysis and $TiO_2$ Photocatalysis

  • Kim, Jung-Kon;Cho, Il-Hyung;Zoh, Kyung-Duk;Choi, Kyung-Ho
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2004.06a
    • /
    • pp.146-150
    • /
    • 2004
  • Degradation efficiency of pentachlorophenol (PCP) by using direct UV photolysis and $TiO_2$ photocatalysis was evaluated with both chemical analyses and acute toxicity assessment employing luminescent bacteria Vibrio fischeri. PCP was chosen as a target compound in this study because of its wide application as fungicide, bactericide, insecticide and wood preservative in agriculture and many industries, in addition to its well-known environmental consequences. The acute toxicity to the microbe was reduced by >60% when applying UV alone, and was completely removed when treated with $UV-TiO_2$ combinations. Toxicity reduction pattern determined with the Microtox Assay generally corresponds with the chemistry data: However, it should be noted that toxicity was greater than expected by the chemistry data. Formation of TCBQ, a toxic byprodut, could not explain observed microbial toxicity. These observations are probably due to the presence of unidentified toxic PCP byproducts, which may include polychlorinated dibenzodioxins and polychlorinated dibenzofurans. When Microtox results were compared between different exposure time, i.e.,5 min and 15 min, an interesting pattern was noted with $UVA-\;TiO_2$ treatment. While no microbial toxicity was observed with 5 min exposure, an EC50 value of 45.4% was estimated with 15 min exposure, which was not observed in $UVB-\;TiO_2$ exposure. This result may suggest the presence of unidentified toxic degradation products generated in the later stage of treatment. Based on this study, $TiO_2$ photocatalyst, together with UVB photolysis could improve the removal of both PCP and its toxic derivatives in more efficient way. The Microtox Assay is promising and economical method for monitoring efficiency of wastewater treatment processes.

  • PDF

Environmental Risk Assessment of Cadmium using National Monitoring Data (수질 및 토양오염 모니터링 결과를 이용한 카드뮴의 환경위해성평가)

  • Park Kwangsik;Shin Dong-chun
    • Environmental Analysis Health and Toxicology
    • /
    • v.19 no.1
    • /
    • pp.65-72
    • /
    • 2004
  • Environmental risk assessment of cadmium compounds was conducted using national monitoring data of aquatic and terrestrial compartments of local area. Aquatic and terrestrial toxicities of cadmium compounds on algae, daphnid, fish, earthworm, springtails and other species were evaluated. The toxicity data evaluated in this study were mainly from ECOTOX database provided by US EPA. Assessment factors were determined according to the EU technical guidance document and/or OECD proposal. Predicted no effect concentration (PNEC) values of aquatic and terrestrial toxicity were 25$\mu\textrm{g}$/L and 0.2 mg/kg, respectively and they were compared with cadmium exposure data of several local areas, which were used as Predicted exposure concentration(PEC) values. Most of the local area were found to be not risky. However, the risk values (PEC/NEC) of some metropolitan areas were greater than 1 when the most conservative PNEC value was applied.