• 제목/요약/키워드: total water

검색결과 12,331건 처리시간 0.036초

토양내 총 NAPL과 공기접촉 NAPL의 측정을 위한 분별 NAPL 분배 추적자 기술의 개발

  • 최경민;김헌기
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2004년도 임시총회 및 추계학술발표회
    • /
    • pp.29-32
    • /
    • 2004
  • Gaseous partitioning tracer test has been used for determining the volume and spatial distribution of residual non-aqueous phase liquid (NAPL) in the unsaturated soils. In this study, an experimental method for measuring the content of gas-exposed NAPL as well as that of total NAPL in a sand during air sparging was developed. Two different gaseous phase NAPL-partitioning tracers were used; n-pentane, with very low water solubility, was used as the tracer that partitions into NAPL that is only in contact with the mobile gas, and chloroform, with fairly good water solubility, was selected for detecting total NAPL content in the sand. Helium and difluromethanewere used as the non- reactive tracer and water-partitioning tracers, respectively. Using n-decane as a model NAPL (NAPL saturation of 0.018), 25.6% of total NAPL was detected by n-pentane at the water saturation of 0.68. Oniy 9.1% of total NAPL was detected by n-pentane at the water saturation of 0.84. This result implies that the quantity of gas-exposed NAPL increased about three times when the water saturation decreased from 0.84 to 0.68. At the water saturation of 0.68, more than 90% of total NAPL was detected by chloroform while 65.8% of total NAPL was detected by chloroform at the water saturation of 0.84. Considering that the removal rate of NAPL during air sparging for NAPL-contaminated aquifer is expected to be greatly dependent upon the spatial arrangement of NAPL phase with respect to the mobile gas, this new approach may provide useful information for investigating the mass transfer process during air-driven remedial processes fer NAPL-contaminated subsurface environment.

  • PDF

수질오염총량관리제 시행에 따른 삽교호의 수질변화 예측 (Forecasting of changes in the water quality in Sapgyo-Lake in accordance with implementation of Total Water Pollutant Load Management System)

  • 김홍수;조병욱;박상현;이무규;김창기;최정호
    • 한국물환경학회지
    • /
    • 제35권3호
    • /
    • pp.209-223
    • /
    • 2019
  • Broadly speaking, in order to analyze the water quality improvement effects of the implementation of the Total Water Pollutant Management System in the Sapgy-Lake waterways, a reference was made to the [Plans for implementation of the Total Maximum Daily Load(TMDL)] in 3 cities (Cheonan, Asan, Dangjin). The results of the investigation into the plans to reduce the pollutant load show in that region show that there are plans to reduce pollution for a total of 16 reduction facilities. As for the result of the computation of the reduction in the load, these measurements were computed at the Gokgyo-stream basin and Namwon-stream basin, with BOD and T-P at the Gokgyo-stream basin reduced by 13.9 % and 13.3 %, respectively, while BOD and T-P at the Namwon-stream were reduced by 3.7 % and 3.3 %, respectively. In this way, thus using the results of the water quality forecast of Sapgyo-Lake in measures for the improvement of water quality (in accordance with the implementation of the TMDL), and using the QUAL-MEV model and EFDC model, it is noted that BOD will be improved by 26.4 % from 6.1 mg/L to 4.5 mg/L 0.0 %, T-P by 36.7 % from 0.168 mg/L to 0.107 mg/L and TOC by 26.4 % from 7.7 mg/L to 5.6 mg/L. However, it is forecasted that the targeted standards for the medium influence area will not be achieved. Evidently, Gokgyo-stream and Namwon-stream have been implementing the Total Water Pollutant Management System for the BOD items since January 1, 2019, but the Sapgyo-stream and Muhan-stream were excluded from being designated as subject regions. As such, it is noted now that it is necessary to implement the TMDL for the entire Sapgyo-Lake water systems including Sapgyo-stream and Muhan-stream in order to improve the water quality of Sapgyo-Lake, and likewise the T-P should be designated as the substance subjected to management in addition to BOD.

학교 용수 원단위 산정 및 용수 사용량 추정 방법에 관한 연구 (Estimation of water unit factor and water demand of educational institutions)

  • 김태영;허동;박희경
    • 상하수도학회지
    • /
    • 제23권4호
    • /
    • pp.481-489
    • /
    • 2009
  • The objective of this research is to provide more reliable and accurate unit factor of water amount by investigating of informations related to various educational institutions such as elementary, middle, high schools and university. In order to estimate the water demand of educational institutions, first of all, the informations such as building area, site area, total school population, and water amount of various educational institutions are investigated to estimate the water unit factor. In this research, we used the total population of students and teachers to estimate the water demand of educational institutions. The results of unit factors of this research are as follows: 1) The elementary school is $0.027983m^3/person{\cdot}day$, 2) middle school: $0.024106m^3/person{\cdot}day$, 3) high school: $0.041415m^3/person{\cdot}day$, 4) specialized high school (science high school and foreign language high school): $0.156938m^3/person{\cdot}day$ and 5) university: $0.033766m^3/person{\cdot}day$. Finally, these water amounts calculated by unit factors were compared with real water amount of educational institutions.

Global Assessment of Current Water Resources using Total Runoff Integrating Pathways and Global GIS

  • Taikan Oki;Takao Saruhashi;Yasushi Agata;Shinjiro Kanae;Katumi Musiake
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2001년도 학술발표회 논문집(I)
    • /
    • pp.67-75
    • /
    • 2001
  • Anticipated water scarcity in the first half of this century is one of the most concerned international issues. However, even though the issue has an international impact and world wide monitoring is critical, there are limited number of global estimates at present. In this study, annual water availability was derived from annual runoff estimated by land surface models using Total Runoff Integrating Pathways (TRIP) with 0.5 degree by 0.5 degree longitude/latitude resolution globally. Global distribution of water withdrawal for each sector in the same horizontal spatial resolution was estimated based on country-base statistics of municipal water use, industrial water use, and agricultural intake, using global geographical information system with global distributions of population and irrigated crop land area. The total population under water stress estimated for 1995 corresponded very well with former estimates, however, the number is highly depend on how to assume the ratio how much water from outside of the region can be used for water resources within the region. It suggests the importance of regional studies evaluating the possibility of water intake as well as the validity of the investment for water resources withdrawal facilities.

  • PDF

양수장 용수공급 논 지대의 물수지 (Water Balance in a Paddy Field with Pumping Irrigation System)

  • 정운태;이근후;이인영
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 1998년도 학술발표회 발표논문집
    • /
    • pp.1-7
    • /
    • 1998
  • To investigate the water balance in a paddy rice field with the pumping station for irrigation water supply, flow measurements and analysis on various components of water balance were carried out. The investigated area is 103.7 ha, and the irrigation water was supplied for 102 days during the total irrigation period starting from June 1. It was found that the consumption rate was increased as the growing stage was progressed. The variation of evapotranspiration rate was shown same tendency as the consumption rate, while no apparent tendency was found in infiltration rate upon different growing stages. And the ground water input to the area was predominant during the early stage of growing period, while ground water output from the study area was predominant at the end of the growing stage. The range of return flow rate, the ratio of total outflow to total inflow in every decad, was 57.6 to 85.7%. These values are slightly higher than reported values from the other investigation projects.

  • PDF

냉각수 계통의 운전변수가 중앙냉방시스템의 에너지소비량에 미치는 영향 (The Effects of Operational Conditions of Cooling Water System on Energy Consumption for Central Cooling System)

  • 안병천
    • 한국지열·수열에너지학회논문집
    • /
    • 제13권4호
    • /
    • pp.8-13
    • /
    • 2017
  • The effects of operational conditions of cooling water system on energy consumption for central cooling system are researched by using TRNSYS program. Cooling tower water pump flow rate, cooling tower fan flow rate, and condenser water temperature with various dry-bulb and wet-bulb temperatures are varied and their effects on total and component power consumption are studied. If the fan maximum flow rates of cooling tower is decreased, cooling tower fan and total power consumptions are increased. If the cooling tower water pump maximum flow rates is decreased, chiller and total power consumptions are increased. If condenser water set-point temperature is increased, chiller power consumption is increased and cooling tower fan power consumption is decreased, respectively.

득량만의 해수 교환 및 물질 순환에 관한 연구 1 . 해수의 수송량 및 교환 시간 (Study on the Water and Material Exchange in Deukryang Bay 1. Volume Transport and Turnover Time of Sea Water)

  • 조규대;이충일
    • 한국환경과학회지
    • /
    • 제7권3호
    • /
    • pp.311-320
    • /
    • 1998
  • The volume transport and turnover time of the Deukryang Bay. located at the southern area of Korea, were calculated based on the current meter(RCM-7,ACM 16M) data observed at the three gateways of the tegrating observed data and then averaging on time. dangdo and Kogumdo. The total water volume transports through three entrances of the bay in May and October were $3.9{\times}10-2Sv, 3.4{\times}10^{-2}Sv(1Sv=10^6m^3s^{-1}$) and turnover time were 0.97day, 1.12day, respectively. Semidiurnal tides were predominant (70~85%). The water volume transports by residual currents were 2~4% of total water volume transports . The average fraction of fresh water calculated by tidal prism method using salinity difference between inflow current and outflow current through three entrances In Deukryang Bay was about 0.06% of total volume and the flushing time of fresh water was estimated as 0.97day.

  • PDF

Estimation of Total Precipitable Water in East Asia Using the MODIS Satellite Data

  • Park, Seon-Ki
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제19권E4호
    • /
    • pp.149-155
    • /
    • 2003
  • In this study. the amounts of the total precipitable water (TPW) in both global and regional scale are estimated from the MODIS instrument, which is on-board the EOS satellites, Terra and Aqua. The estimation is made from the five near-infrared spectral bands, using a technique employing ratios of water- vapor absorbing channels centered at 0.905, 0.936, 0.940 ${\mu}{\textrm}{m}$ with atmospheric window channels at 0.865 and 1.240 ${\mu}{\textrm}{m}$. Through analyses of monthly and eight-days mean TPW, one can monitor characteristics of seasonal variations as well as amount and distribution (i.e., water resources) of TPW at both global and local regions. Long-term monitoring of TPW is essential to understand the regional variations of water resources in East Asia.

Assessment of microbial quality in household water tanks in Dubai, United Arab Emirates

  • Khan, Munawwar Ali;AlMadani, Asma Mohammad Abdulrahman Ahmad
    • Environmental Engineering Research
    • /
    • 제22권1호
    • /
    • pp.55-60
    • /
    • 2017
  • Provision of safe, accessible, and good water quality in the community is an important step towards reducing various waterborne illnesses. However, improving the quality of water should include spreading awareness to the public regarding the importance of cleaning their household water tanks. The aim of this study was to investigate the microbial quality of water of household water tanks in Dubai. The water samples from household water tanks were collected from forty houses, and a questionnaire was given to the residents to determine the history of the water tanks. The membrane filtration technique was used to quantify heterotrophic and total coliform bacteria on plate count agar and the violet red bile agar respectively. The overall results of this study have shown that 18 out of total 40 household water tanks contained different types of bacteria concentration level beyond local and widely accepted international standards. The overall results of this study indicated that there is a lack of awareness among residents regarding the importance of maintaining proper sanitation and hygiene of the household water tanks.

저수조의 효율적 관리를 위한 수질실태에 관한 연구 (A Study on the Water Quality for Efficient Management in the Water Tanks)

  • 박현건;류승철;전수임
    • 한국환경과학회지
    • /
    • 제18권12호
    • /
    • pp.1339-1347
    • /
    • 2009
  • This study tried to investigate and analyze the actual state such as the regional, classified, and material characteristics of the water quality in order to research the several factors by which the filtrated water of the total 250 cases can be polluted in the water tank. The 215 points (86%) clean the water tanks twice a year regularly and J-city has done the best job of cleaning the water tanks. The fifty points (20%) of the total 250 investigation points examine the water quality of the water tanks every year, however, the 175 investigation points (70%) do not execute the inspection of water quality. In the case of the regional characteristics in the water quality, the 23 points (46%) in H-county, the 17 points (34%) in S-county, and the 16 points (32%) in G-city are incongruent in the standard, and the incongruity ratio of the water quality in J-city is the lowest. The result of the classified incongruity shows that total coliforms were found at the 61 investigation points, mesophilic bacteria were found at the 27 points, and turbidity was found at the 12 points. In the case of the material incongruity, concrete was found at the 63 investigation points as the most distinguished factor, and FRP (fiberglass reinforced plastic) at the 23 points, SMC (sheet molding compound) at the 12 points, and stainless steel was found at the 2 points.