• Title/Summary/Keyword: total viable cell count

Search Result 101, Processing Time 0.024 seconds

Seasonal Variations of Water Quality in the Lower Part of the Nagdong River (낙동강 하류수질의 계절적 변화)

  • KIM Yong-Gwan;SHIM Hye-Kung;CHO Hak-Rae;YOU Sun-Jae
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.17 no.6
    • /
    • pp.511-522
    • /
    • 1984
  • The Nagdong is one of the biggest rivers in Korea, which is very important water source not only for tap water of Pusan city but also for the industrial water. Therefore, authors tried to check the water quality year by year. In this experiment one hundred and twenty water samples collected from August 1983 to July 1984 were analyzed bacteriologically and physiologically. Fifteen sampling stations were established between near Samrangjin and estuary of the river. To evaluate the water quality, temperature, pH, chloride ion, salinity, chemical oxygen demand (COD), electrical conductivity, nutrients, total coliform, fecal coliform, fecal streptococcus, viable cell count and bacterial flora were observed. The variation of water temperature was ranged $-1.5{\sim}29.0^{\circ}C$ (Mean value $13.9{\sim}16.5^{\circ}C$), it in spring was higher as $10{\sim}15^{\circ}C$ about $10^{\circ}C$ than in winter and it in autumm was very stabilized as about $20^{\circ}C$ at each station. The pH variation of the samples was ranged $6.68{\sim}9.15$. The range of concentration of chloride ion and salinity varied $7.4{\sim}l,020.5$ mg/l and $1.05{\sim}33.0\%0$, respectively. Especially, salinity of the 3rd water war was the higher than others as $25.76{\sim}31.58\%0$. COD was ranged $1.45{\sim}14.94$ mg/l and the lower part of the Nagdong River was heavily contaminated by domesitc sewage and waste water from the adjacent factor area. The range of electrical conductivity was $1.360{\times}10^2{\sim}5.650{\times}10^4{\mu}{\mho}/cm$ and that was by far higher the estuary than the upper. Concentration of nutrients were $0.008{\sim}0.040$ mg/l (Mean value $0.019{\sim}0.068$ mg/l) for $NO_2-N,\;0.038{\sim}5.253$ mg/l ($0.351{\sim}2.347$ mg/l) for $NO_3-N,\;0.100{\sim}2.685$ mg/l($0.117{\sim}1.380$ mg/l) for $NH_4-N,\;0.003{\sim}0.084$ mg/l($0.014{\sim}0.065$ mg/l) for $PO_4-P$ and $0.154{\sim}6.123$ mg/l ($1.165{\sim}3.972$ mg/l) for $SiO_2-Si$, respectively. Usually nutrients contents of the water in the upper part(included station 1 to 5) were higher than those of the estuarine area. The bacterial density of the samples ranged 7.3 to 460,000/100 ml for total coliforms, 3.6 to 460,000/100 ml for fecal coliform, $0{\sim}46,000/100ml$ for fecal streptococcus and $<30{\sim}1.2{\times}10^5/ml$ for viable cell count. Composition of coliform was $28\%$ Escherichia coli group, $18\%$ Citrobacter freundii group, $31\%$ Enterobacter aerogenes group and $22\%$ others. Predominant species among the 659 strains isolated from the samples were Pseudomonas spp. ($42\%$), Flavobacterium spp. ($20\%$) and Moraxella spp. ($12\%$).

  • PDF

Rice Fermentation by Korean Amylolytic Bifidobacterium spp. (한국인유래의 Amylolytic Bifidobacterium 에 의한 쌀발효)

  • Park, Jong-Hyun;Song, Hey-Kyung;Ahn, Jun-Bae;Ji, Geun-Eok;Mok, Chul-Kyoon
    • Korean Journal of Food Science and Technology
    • /
    • v.29 no.3
    • /
    • pp.581-587
    • /
    • 1997
  • For bifidus fermentation food, gelatinized rice solution was fermented without liquefaction/saccharification by amylolytic Bifidobacterium spp. isolated from Korean. Eighteen amylolytic Bifidobcterium on the starch agar were isolated from 38 Korean and four strains were finally selected as good amylase producers. The most enzyme-producing strain of Bif. sp. FBD-12 secreted extracellular amylase of 0.17 U/mg and intracelluar amylase of 1.8 U/mg. Three strains of Bif. sp. FBD-12, Bif. sp. FBD-16 and Bif. sp. FBD-17 also showed good growth on pH controlled media by HCI/acetic acid to pH 5.0 while Bif. sp. FBD-6 was not so tolerant that viable cell counts reduced to $10^2\;CFU/mL$ times on the media. Initial cell number of $10^6\;CFU/mL$ for those strains reached to $10^9\;CFU/mL$ on the rice medium supplemented with yeast extract (0.2%) and cysteine (0.05%). Ascorbic acid instead of cysteine was added to the medium for improving off-flavour and the best growth was shown at 0.1% addition. Isolated soybean proteins (ISP) of 3% accelerated the growth of the strains. Maximum count of $10^9\;CFU/mL$ reached within 12 hour fermentation on the rice medium with ascorbic acid and isolated soybean protein instead of 32 hours on the cysteine medium, and total acidity increased from 0.5% to 1% on each media. Reducing sugar in the ascorbic acid/ISP cultures generally increased especially 2 mg/mL to 15.5 mg/mL for Bif. sp. FBD-6. From sensory evaluation, the products showed good acceptability so that it suggested possibility of development of bifidus-fermented rice food.

  • PDF

Comparison of Quality Characteristics of Sesame leaf Cleaned with Various Electrolyzed Water during Storage (다양한 전기분해수 세정처리에 따른 깻잎의 저장중 품질특성 비교)

  • Jeong Jin-Woong;Kim Jong-Hoon;Kwon Kee-Hyun
    • Food Science and Preservation
    • /
    • v.12 no.6
    • /
    • pp.558-564
    • /
    • 2005
  • This study was carried out to investigate the cleaning effect of sesame leaf, the sterilization effect and physicochemical properties, treated with various electrolyzed water. Initial physicochemical properties could be kept more than 1 month in electrolyzed oxidizing water(EW-1) of diaphragm type and 15 days in electrolyzed water(EW-2 and EW-3) of non-diaphragm system, there was no significant difference by storage temperature. 4 kinds of microorganism (initial total counts, $10^7\~10^9$ CFU/mL) were sterilized within $0.5\~1$ minutes by electrolyzed water. In fresh sesame leaves, total viable cell count and coliform group in the treatment of electolyzed water were decreased to about $2\~3$ log scale comparing non-treated ones. Especially Bacillus cereus was not detected until 13th day when treated with EW-l. Decaying ratio of sesame leaf appears on day 6 of storage in the untreated but the treatments of electrolyzed water has no sign until day 10 of storage. Change in color difference(${\Delta}E$) during storage was observed the treatments of electrolyzed low-alkaline water(EW-2) and electrolyzed neutral water(EW-3) were very desirable at the level $1\~2$ after day 13 of storage comparative to the untreated Change of Chlorophyll content was biggest decreased to 6.8 $mg\%$ on the untreated and decreased least to 8.35 $mg\%$ on EW-3 treated group on 13th day from initial value of $9.0\~10.3\;mg\%$ The overall sensory evaluation appeared most acceptable in the treatments of EW-2 and EW-3.

Comparison of Ethylene Oxide (E.O.) and Irradiation Treatment on the Sterilization of Spices (향신료(香辛料)의 Ethylene Oxide 처리(處理)와 감마선(線) 조사(照射)와의 살균효과 비교)

  • Cho, Han-Ok;Byun, Myung-Woo;Kwon, Joong-Ho;Lee, Jae-Won;Yang, Jae-Seung
    • Korean Journal of Food Science and Technology
    • /
    • v.18 no.4
    • /
    • pp.283-287
    • /
    • 1986
  • E.O. and gamma irradiation treatment on the sterilization of ground samples of 5 different types of spices(red and black pepper, onion, garlic and ginger) were investigated. Populations of mesophilic bacteria, mesophilic spores, acid tolerant bacteria and fungi in various samples were $10^4-10^6/g,\;10^3-10^5/g,\;10^3-10^5/g\;and\;10^3-10^4/g$, respectively. Coliforms and osmophilic molds were found only in red and black pepper as $10^3-10^4/g$. A radiation dose of 5 to 7 kGy proved sufficient to redure the viable cell count of the total bacteria and fungi to the level of $10^3/g$ and they were sterilized completely by radiation dose of 10 kGy or more. Coliforms, mesophilic spores and acid tolerant bacteria were sterilized at 5,7 and 10 kGy, respectively. In the mean time $D_{10}$ values of each spices ranged from 1.38 to 2.88 kGy. Comparison of E.O. and gamma irradiation treatment showed that E.O. treatment was less effective than radiation in controlling microbial contamination in spices.

  • PDF

Prevention of Discoloration and Storage Stability in Canned Ark Shell (새고막 통조림 변색방지 및 저장중 품질변화)

  • 배태진;김귀식
    • The Korean Journal of Food And Nutrition
    • /
    • v.11 no.2
    • /
    • pp.243-248
    • /
    • 1998
  • Ark shell was known as shellfish that had hemoglobin as blood pigment and the action of mecidine, was consumed the great part of it as raw material, though it was produced about 13,000 M/T per year. Ark shell was processed the infinitesimal quantity as conned product, bout canned ark shell had problem that occurrenced discoloration after heat treatment during processing and storage. This discoloration mechanism during processing and storage was not cleared. This study was carried out to understand characteristics of the hemoglobin as blood pigment and carotenoid as meat pigment in ark shell and management of proper processing conditions for prevention of oxidation and discoloration by thermal treatment. When treated by digestion of 0.1% BHA, 0.1% Tenox-II, 0.5% Na2EDTA, 0.05% NDGA and 3% salt soln., 0.1% BHA solution was most suitable for stability of carotenoid that the retention ratio of carotenoids were 63.1% after heating to 116$^{\circ}C$ for 120 minutes. In preparation of canned ark shell and storage at 37$\pm$1$^{\circ}C$ for 60 days, the chemical composition, pH and salinity ere stable. And contents of total carotenoid were decreased slightly from 0.83mg% to 0.727mg%. The viable cell count were 6.92$\times$103 cfu/ml at raw ark shell, after processed and storage were not detected. The predominant amino acids in the raw ark shell were glutamic acid(19.7%), arginine(16.0%), glycine(12.6%), alanine(12.2%) and aspartic acid(7.6%). When 60 days stored, the contents of amino acid were stable. And the predominant nuclotide and their related compounds in the raw ark shell were hypoxanthine(2.14$\mu$mol/g), IMP(1.94$\mu$mol/g) and ATP(0.87$\mu$mol/g), and storage at 37$\pm$1$^{\circ}C$ for 60 days, the quantity order were same as raw material.

  • PDF

Studies on Food Preservation by Controlling Water Activity III. Quality Changes of Fish Meat during Drying and Storage (식품보장과 수분활성에 관한 연구 3. 어육의 건조 및 저장중의 품질)

  • HAN Bong-Ho;LEE Jong-Gab;BAE Tae-Jin
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.16 no.3
    • /
    • pp.181-189
    • /
    • 1983
  • A study on the qualify changes of fish meat during drying and storage has been carried out with filefish meat. Filefish meat was dried in a forced air dryer at 40 and $55\%$ for 20 hours with an air velocity of 0.4 m/sec under different conditions of relative air humidities in the range of 10 to $50\%$. The dried fish meat was stored at $30^{\circ}C$ in chambers with constant relative humidities controlled by the use of conditioned air stream passing through the saturated salt solutions. The qualify of filefish meat was evaluated with the brown color densities developed by lipid oxidation and Maillard reaction. Changes of viable cell count during drying and storage were also discussed. The predominant reaction for the brown color developed during the study period was the lipid oxidation. The lipid oxidation rate during drying at constant temperature was appreciably affected by water activities at the drying surfaces of filefish meat during the falling drying rate period. The lipid oxidation rate was the slowest under the condition of the relative air humidity of around $30\%$. In samples stored at water activity of 0.33, the lipid oxidation rate was retarded remarkably in comparison with the samples with lower or higher water activities. The addition of $1\%$ table salt, $1.5\%$ D-sorbitol and $6\%$ sucrose slightly lowered the water activity with the slowest lipid oxidation rate. Such additives resulted the increase of the water soluble brown color densities, which seemed due to the increase of mobility of the water soluble substances by the result of the increase of equilibrium water content. Microflora of the samples immediately after drying consisted of ca. $30\%$ of coccus types, ca. $65\%$ of rod types and ca. $5\%$ of molds and yeasts. During the storage of the samples with a water activity of 0.76, the ratio of the coccus types to the total microflora was increased remarkably while that of the Gram negative non-spore rod types was decreased. The ratios of the Gram positive rod types, molds and yeasts during the storage were nearly constant.

  • PDF

Quality Changes of Minimally Processed Sliced Deodeok (Codonopsis lanceolata) during Storage by Packaging Method (포장방법 차이에 따른 신선편이 슬라이스 더덕의 저장 중 품질 변화)

  • Choi, Duck-Joo;Lee, Yun-Jung;Kim, Youn-Kyeong;Kim, Mun-Ho;Choi, So-Rye;Park, In-Seon;Cha, Hwan-Soo;Youn, Aye-Ree
    • Food Science and Preservation
    • /
    • v.19 no.5
    • /
    • pp.626-632
    • /
    • 2012
  • In this study, the changes that occurred in the quality of minimally processed sliced Deodeok (Codonopsis lanceolata) in relation to the packing method during storage at $7^{\circ}C$ were investigated. The storage tests were conducted for seven days using PE sealing, but PP sealing and vacuum packaging preserved the Deodeok for 14 days. On the seventh day, the vinyl-packaged Deodeok showed a remarkable fall in quality with 4.5 °Brix, but the PP-sealed and vacuum-packaged Deodeok showed slight falls with 6.4 and $6.8^{\circ}Brix$, respectively. The PE- and PP-sealed Deodeok did not show significant differences in texture and moisture content for two days, and the moisture content was highest in the vacuum-packaged Deodeok during storage. In relation to the total viable cell and the coliform count, the vacuum-packaged Deodeok showed the lowest rate of increment during storage, followed by the others. Thus, the bubble-washed and vacuum-packaged minimally processed sliced Deodeok was found to have the best quality.

Physicochemical properties and oxidative stabilities of chicken breast jerky treated various sweetening agents (당침지 처리된 닭 가슴살 육포의 이화학적 특성 및 산화안정성)

  • Nam, Dong-Geon;Jeong, Beom-Gyun;Chun, Jiyeon
    • Food Science and Preservation
    • /
    • v.24 no.1
    • /
    • pp.84-92
    • /
    • 2017
  • Chicken breast jerky (CJ) was prepared by drying chicken breast at $50^{\circ}C$ for 9 hrs after marinating it in a various sweetening sauce including white sugar (WS), brown sugar (BS), rice syrup (RS), fructooligosaccharide (FO), pineapple concentrate (PC), Rubus coreanus extract (RCE), or honey (H), and its physicochemical and sensory properties were investigated. The CJ was found to contain 22.5-25.0% moisture, 41.0-46.6% protein, and 0.4-1.0% fat, which indicates that it could serve as a high-protein and low-fat snack. The type of sweeteners significantly affected the yield, pH, total viable cell count, and water activity of the CJ, showing ranges of 40.9-50.1%, 5.2-5.9, $2.5-6.2{\times}10^4CFU/g$, and 0.74-0.81, respectively. Both the water activity and pH were the lowest in CJ-RCE where of the highest in CJ-WS. The cohesiveness, springiness, and chewiness of the CJ significantly differed depending on the type of sweeteners (p<0.05). CJ-RCE showed the best taste and overall acceptability in a sensory test. After storage at $50^{\circ}C$ for 2 weeks, thiobarbituric acid reactive substance (TBARS) content (58.3 malondialdehyde (MDA) mg/kg) of CJ-RCE was much lower than those of control beef (75.6 MDA mg/kg) and pork jerky (98.0 MDA mg/kg), showing the good oxidative stability of CJ-RCE. Overall, marination in RCE sauce was suitable for the preparation of CJ with good quality in terms of its water activity, fat and protein contents, sensory property and oxidative stability.

Food Quality Characterization and Safety of Imported Fish Roe (Japanese flyingfish roe, Capelin roe and Pacific herring roe) (수입 어란(날치 알, 열빙어 알 및 청어 알)의 품질 특성과 안전성)

  • Lee, Jong-Soo;Kim, Jin-Soo;Kim, Jeong-Gyun;Oh, Kwang-Soo;Choi, Byeong-Dae;Park, Kwon Hyun;Choi, Jong-Duck
    • Journal of agriculture & life science
    • /
    • v.45 no.6
    • /
    • pp.95-108
    • /
    • 2011
  • The food quality characterization and safety Japanese flying fish roe (JFF-R), capelin roe (C-R), Pacific herring roe (PH-R) were investigated. The size of JFF-R was 1.48-1.93 mm, which was longer than those of C-R and PH-R. The moisture content of JFF-R imported from Peru (JFF-R-P) was 70.3%, which was higher than that of JFF-R imported from China (JFF-R-C) (67.4%), while was lower than that of JFF-R imported from Indonesia (JFF-R-I) (83.3%). However, the salinity of JFF-R-P was 13.6%, which was lower than that of JFF-R-C, while was higher that of JFF-R-I (1.8%). The moisture contents and salinities of the other fish roes were 80.4% and 3.2%, respectively, for capalin roe, and 65.4% and 20.0%, respectively, for Pacific herring roe. According to the results of pH, volatile basic nitrogen content, heavy metal content, viable cell count and coliform group, the fish roes could be used as sanitary sources for preparation of seasoned JFF-R. The major fatty acids of fish roes were 16:0 (27.8-30.5%), 18:1n-9 (7.2-8.0%), 20:5n-3 (5.6-8.2%) and 22:6n-3 (22.0-25.6%) in JFF-R, and 16:1n-7 (6.7-9.3%) as well as these fatty acids in C-R and PH-R. Total amino acid contents of fish roes ranged from 9.44 g/100 g to 10.39 g/100 g and their major amino acids were aspartic acid, glutamic acid, leucine and lysine. The mineral content of JFF-R were higher than those of the other fish roes expected for zinc of JFF-R-I. According to the results of sensory evaluation, the color and texture of JFF-R-P were superior to those of the other fish roes. No difference was, however, found in flavor, among JFF-R-P and the other fish roes.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF