• 제목/요약/키워드: total torque

검색결과 324건 처리시간 0.027초

A comparison of bone bed preparation with laser and conventional drill on the relationship between implant stability quotient (ISQ) values and implant insertion variables

  • Lee, Su-Young;Piao, Chunmei;Heo, Seong-Joo;Koak, Jai-Young;Lee, Joo-Hee;Kim, Tae-Hyung;Kim, Myung-Joo;Kwon, Ho-Beom;Kim, Seong-Kyun
    • The Journal of Advanced Prosthodontics
    • /
    • 제2권4호
    • /
    • pp.148-153
    • /
    • 2010
  • PURPOSE. The aim of this study was to investigate a comparison of implant bone bed preparation with Er,Cr:YSGG laser and conventional drills on the relationship between implant stability quotient (ISQ) values and implant insertion variables. MATERIALS AND METHODS. Forty implants were inserted into two different types of pig rib bone. One group was prepared with conventional drills and a total of 20 implants were inserted into type I and type II bone. The other group was prepared with a Er,Cr:YSGG laser and a total of 20 implants were inserted into type I and type II bone. ISQ, maximum insertion torque, angular momentum, and insertion torque energy values were measured. RESULTS. The mean values for variables were significantly higher in type I bone than in type II bone (P < .01). In type I bone, the ISQ values in the drill group were significantly higher than in the laser group (P < .05). In type II bone, the ISQ values in the laser group were significantly higher than in the drill group (P < .01). In both type I and type II bone, the maximum insertion torque, total energy, and total angular momentum values between the drill and laser groups did not differ significantly (P ${\geq}$ .05). The ISQ values were correlated with maximum insertion torque (P < .01, r = .731), total energy (P < .01, r = .696), and angular momentum (P < .01, r = .696). CONCLUSION. Within the limitations of this study, the effects of bone bed preparation with Er,Cr:YSGG laser on the relationship between implant stability quotient (ISQ) values and implant insertion variables were comparable to those of drilling.

21-68세 남녀 100명의 슬관절 굴근과 신근의 근력에 대한 등속성 평가 (Isikinetic evaluation of the knee flexors and extensors on muscle strength in 100 men and women aged 21 - 68yr)

  • 남형천
    • 대한물리치료과학회지
    • /
    • 제8권2호
    • /
    • pp.967-976
    • /
    • 2001
  • The purpose of the present study was to the investigate the effect of aging in men and women on muscle strength of knee extensor and flexors by using the cybex 6000 isokinetic dynamometer. A total of 100 volunteers participated in this study and were divided into five groups according to their chronological age as follows: 20s, 30s, 40s, 50s, 60s, 10 men and 10 women in each decade respectively. Isokinetic ($60^{\circ}{\cdot}s-l$) knee extensor and flexor peak torque, peak torque to body weight ratio, opposing muscles(flexor/extensor) peak torque ratio, deficit of peak torque between dominant and non-dominant were measured. The results obtained were as follows: 1) In men, While the aged increased. the peak torque of the knee flexor and extensor statistically sig nificant decreased in the dominant and non-dominant side. 2) In women, Statistically significant difference of knee extensor peak torque was found as the aged increased in the dominant and non-dominant side, but significant difference of knee flexor peak torque did not that. 3) In men, No significant difference in the peak torque of knee flexor to body weight ratio was found as the aged increased in the non-dominant side, but statistically significant difference in the peak torque of knee flexor to body weight weight ratio was found as the aged increased in the dominant side. 4) In women. No significant difference in the peak torque of knee flexor to body weight ratio was found as the aged increased in the dominant side, but statistically significant difference in the peak torque of knee flexor to body weight ratio was found as the aged increased in the non-dominant side. 5) In men and women, While the aged increased, statistically significant difference was found the dominant and non-dominant side in the peak torque of knee extensor to body weight ratio. 6) Peak torque of hamstring to quadriceps ratio of dominant and non-dominant side in men and women were not significantly different as the age increases. 7) Mean deficit of peak torque between dominant and non-dominant side in men and women were not significantly different as the age increases. From these results we conclude a proper exercise program is need before 50s decade to preserve in muscle strength of knee flexors and extensors.

  • PDF

슬관절전치환술 환자의 슬관절 신전근 및 굴곡근에 대한 등속성운동 효과 (Isokinetic Effect of the Extensors and Flexors in Total Knee Replacement Patients)

  • 배성수;남건우;이근희
    • The Journal of Korean Physical Therapy
    • /
    • 제13권1호
    • /
    • pp.19-31
    • /
    • 2001
  • The twenty one individuals with total knee replacement who were admitted to Kang-Dong Hospital for comprehensive physical therapy were studied in order to demonstrate the effectiveness of an isokinetic test program using the Cybex 6000 machine. The subjects were divided into three groups with the isometric exercise group receiving isometric exercise. the isokinetic eccentric exercise group, and isokinetic eccentric exorcise group receiving isokinetic exercise(eccentric. concentric) to knee flexors and extensors muscles for a six weeks period using the Cybex 6000. The results were follow :1 . The peak torque was increased significantly in the flexors and extensors of the isokinetic conccentric exorcise among three groups(p<.05). 2. The progress of peak torque was increased significantly in the flexors and extensors of the isokinetic conccentric exercise among three groups(p<.05). 3. The total work was more increased significantly in the flexors and extensors of the isokinetic conccentric exercise among three groups(p<.05). 4. The progress of total work was more increased significantly in the flexors and extensors of the isokinetic conccentric exercise among three groups(p<;.05). 5. The ratio of endurance was not increased significantly in all three groups. 6. The extensors in the peak torque was likely to recover rapidly than the flexors. 7.The average R.O.M in the pre-exercise and post-exercise was not different significantly in all three groups. According to the above results, In the muscle strength recovery for total knee replacement patients, isokinetic concentric exercise group was significantly greater than the isokinetic eccentric and isometric exercise groups after a six weeks training.

  • PDF

Estimation of ultimate torque capacity of the SFRC beams using ANN

  • Engin, Serkan;Ozturk, Onur;Okay, Fuad
    • Structural Engineering and Mechanics
    • /
    • 제53권5호
    • /
    • pp.939-956
    • /
    • 2015
  • In this study, in order to propose an efficient model to predict the torque capacity of steel fiber reinforced concrete (SFRC) beams, the existing experimental data related to torsional response of beams is reviewed. It is observed that existing data neglects the effects of some parameters on the variation of torque capacity. Thus, an experimental research was also conducted to obtain the effects of neglected parameters. In the experimental study, a total of seventeen SFRC beams are tested against torsion. The parameters considered in the experiments are concrete compressive strength, steel fiber aspect ratio, volumetric ratio of steel fibers and longitudinal reinforcement ratio. The effect of each parameter is discussed in terms of torque versus unit angle of twist graphs. The data obtained from this experimental research is also combined with the data got from previous studies and employed in artificial neural network (ANN) analysis to estimate the ultimate torque capacity of SFRC beams. In addition to parameters considered in the experiments, aspect ratio of beam cross-section, yield strengths of both transverse and longitudinal reinforcements, and transverse reinforcement ratio are also defined as parameters in ANN analysis due to their significant effects observed in previous studies. Assessment of the accuracy of ANN analysis in estimating the ultimate torque capacity of SFRC beams is performed by comparing the analytical and experimental results. Comparisons are conducted in terms of root mean square error (RMSE), mean absolute error (MAE) and coefficient of efficiency ($E_f$). The results of this study revealed that addition of steel fibers increases the ultimate torque capacity of reinforced concrete beams. It is also found that ANN is a powerful method and a feasible tool to estimate ultimate torque capacity of both normal and high strength concrete beams within the range of input parameters considered.

Effect of microthreads on removal torque and bone-to-implant contact: an experimental study in miniature pigs

  • Kwon, Yee-Seo;Namgoong, Hee;Kim, Jung-Hoon;Cho, In Hee;Kim, Myung Duk;Eom, Tae Gwan;Koo, Ki-Tae
    • Journal of Periodontal and Implant Science
    • /
    • 제43권1호
    • /
    • pp.41-46
    • /
    • 2013
  • Purpose: The objective of this study was to evaluate the effect of microthreads on removal torque and bone-to-implant contact (BIC). Methods: Twelve miniature pigs for each experiment, a total of 24 animals, were used. In the removal torque analysis, each animal received 2 types of implants in each tibia, which were treated with sandblasting and acid etching but with or without microthreads at the marginal portion. The animals were sacrificed after 4, 8, or 12 weeks of healing. Each subgroup consisted of 4 animals, and the tibias were extracted and removal torque was measured. In the BIC analysis, each animal received 3 types of implants. Two types of implants were used for the removal torque test and another type of implant served as the control. The BIC experiment was conducted in the mandible of the animals. The $P_1-M_1$ teeth were extracted, and after a 4-month healing period, 3 each of the 2 types of implants were placed, with one type on each side of the mandible, for a total of 6 implants per animal. The animals were sacrificed after a 2-, 4-, or 8-week healing period. Each subgroup consisted of 4 animals. The mandibles were extracted, specimens were processed, and BIC was analyzed. Results: No significant difference in removal torque value or BIC was found between implants with and without microthreads. The removal torque value increased between 4 and 8 weeks of healing for both types of implants, but there was no significant difference between 8 and 12 weeks. The percentage of BIC increased between 2 and 4 weeks for all types of implants, but there was no significant difference between 4 and 8 weeks. Conclusions: The existence of microthreads was not a significant factor in mechanical and histological stability.

여자대학축구선수와 일반여자대학생의 슬관절 신전근 및 굴곡근의 등속성 운동 비교연구 (A Study on Comparison of Isokinetic Testing of the Knee Extensors and Flexors for the Woman College Soccer Players and General Waman College Students)

  • 김순영;박종항
    • 대한정형도수물리치료학회지
    • /
    • 제8권2호
    • /
    • pp.31-43
    • /
    • 2002
  • The subjects of this study were 15 woman soccer players and 15 untrained woman students at H-Cheju University. Each subject was measured on the muscle strength and peak torque of knee extensors and knee flexors with isokinetic load ($60^{\circ}$/sec, $180^{\circ}$/sec). The results were as follows: 1. There was no significant difference between right and left leg strength measured isokinetically in each group. 2. The peak torque of knee extensors and flexors was significantly higher in scoccer players than untrainded students (p<0.001). 3. For the angle of knee joint showing the highest peak torque, there was significant difference between soccer players and untrained students in knee extensors(p<0.05) and right flexors (p<0.01). 4. For knee H/Q ratio, there was significant difference between two groups(p<0.05). 5. For the total work and average power at $180^{\circ}$/sec, there was significant difference between two groups in knee extensors(p<0.001) and flexors(p<0.01). 6. In soccer players at $60^{\circ}$/sec, there were significant correlations between peak torque and height and between peak torque and weight.(p<0.001). 7. For the muscular contraction velocity at $60^{\circ}$/sec, there was significant difference between two groups in flexors (p<0.01). 8. For the muscular indurance at $180^{\circ}$/sec in extensors and flexors, there was no significant difference between two groups(p<0.05). In conclusion, there were significantly higher in peak torque, contraction velocity, knee joint's angle with the highest peak torque, H/Q ratio, total work and average power in woman scoccer player than general students. But there was no significant difference in muscular endurance. Soccer performance is based on the various components including muscular endurance that is one of the most important components. So it is necessary that the training method to improve the various components (especially including muscular endurance) should be done.

  • PDF

클러치의 장착이 하악의 비틀림회전운동에 미치는 영향 (Effects of Clutch Adaptation on the Mandibular Rotational Torque Movement)

  • 한경수;이규미;허문일
    • Journal of Oral Medicine and Pain
    • /
    • 제24권2호
    • /
    • pp.207-217
    • /
    • 1999
  • This study was performed to investigate the effects of clutch adaptation on the mandibular rotational torque movement in normal people. 69 dental students were selected for the study. Their mean age were 23.6 years and they did not present any signs and symptoms of temporomandibular disorders. $BioEGN^{(R)}$ with $Rotate^{(R)}$ program was used to observe and record the amount of mandibular rotational torque on protrusion, on right excursion, on left excursion, and on comfortable wide opening movement. The natural tooth contact movement and the movement with clutch were performed in the above four each mandibular movement. Clutch was made by the method used in $Pantronic^{(R)}$ clutch fabrication. Distance of slant frontal which was translatory trajectory in frontal plane and degree of rotational torque in horizontal and in frontal plane were recorded. The data obtained were processed with SPSSWIN program and the results were as follows : 1. Distance of slant frontal in each mandibular movement generally increased with clutch. 2. Degree of rotational torque in horizontal and in frontal plane on protrusion and on lateral excursions did not increase with clutch, but the degree on wide opening increased with clutch. 3. Degree of rotational torque in horizontal plane on protrusion and on lateral excursions did not show any difference between right and left side, but the degree in frontal plane on protrusion and on lateral excursions showed significant difference between right and left side. 4. Total amount of rotational torque from right and left sides on protrusion and lateral excursions were not increased with clutch, but the degree on wide opening movement was increased with clutch. And in this case, degree in horizontal plane was larger than that in frontal plane. 5. Correlation between total amount of rotational torque in horizontal plane and that in frontal plane were highly significant on protrusion and on lateral excursions with or without clutch, but the significant correlation on wide opening without clutch became not significant with clutch.

  • PDF

Unison U50 직접구동 영구자석 발전기를 기반으로 한 900kW급 동기발전기 설계 및 최적화 (Design and optimization of 900kW class PMSG, based on Unison U50 model)

  • 김태훈;이상우;김동언;정진화;박현철
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 추계학술대회 논문집
    • /
    • pp.423-426
    • /
    • 2009
  • POSTECH Graduate School of Wind Energy is trying to upgrade the PMSG used for Unison U50 to 900 kW class. Intensive optimization efforts are carried out the reduce the axial size and total weight of the generator while increasing the rated output to 900 kW. The generator features 3.32m stator inner radius, 671mm stator length, 84 pole, 25 rated rpm and 31.6kN/$m^2$ shear force density. To reduce the gross weight, the stronger magnetic material is applied with optimal magnet size resulting lowest cogging torque. Also, instead of stator skewing the stator, the magnet position along the circumference is optimized to further reduce the cogging torque. This scheme eliminates the stator skewing procedure and may enhance the productivity. This method also reduces the total harmonic distortion. In this report, upgrade method, no-load line to line voltage and phase voltage, cogging torque, loss calculations and thermal analysis are presented.

  • PDF

Time Switch용 Step Motor 개발 (Development of Step Motor for Time Switch)

  • 김철호;이우석;서영택;오철수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1147-1149
    • /
    • 2005
  • Time switch is widely used to reduce the energy loss by selecting the duration of daily-based operating pattern for the electrical apparatus. Driving force of the time switch is the single-phase step motor which has the starting torque due to the asymmetrical airgap. Cogging and total torque of the tapered-airgap motor is analyzed by finite element method.

  • PDF

Novel Switching Table for Direct Torque Controlled Permanent Magnet Synchronous Motors to Reduce Torque Ripple

  • Arumugam, Sivaprakasam;Thathan, Manigandan
    • Journal of Power Electronics
    • /
    • 제13권6호
    • /
    • pp.939-954
    • /
    • 2013
  • The Direct Torque Control (DTC) technique for Permanent Magnet Synchronous Motors (PMSM) is receiving increased attention due to its simplicity and robust dynamic response when compared with other control techniques. The classical switching table based DTC results in large flux and torque ripples in the motors. Several studies have been reported in the literature on classical DTC. However, there are only limited studies that actually discuss or evaluate the classical DTC. This paper proposes, novel switching table / DTC methods for PMSMs to reduce torque ripples. In this paper, two DTC schemes are proposed. The six sector and twelve sector methodology is considered in DTC scheme I and DTC scheme II, respectively. In both DTC schemes a simple modification is made to the classical DTC structure. The two level inverter available in the classical DTC is eliminated by replacing it with a three level Neutral Point Clamped (NPC) inverter. To further improve the performance of the proposed DTC scheme I, the available 27 voltage vectors are allowed to form different groups of voltage vectors such as Large - Zero (LZ), Medium - Zero (MZ) and Small - Zero (SZ), where as in DTC scheme II, all of the voltage vectors are considered to form a switching table. Based on these groups, a novel switching table is proposed. The proposed DTC schemes are comparatively investigated with the classical DTC and existing literatures through theory analysis and computer simulations. The superiority of the proposed DTC method is also confirmed by experimental results. It can be observed that the proposed techniques can significantly reduces the torque ripples and improves the quality of current waveform when compared with traditional and existing methods.