• 제목/요약/키워드: total torque

검색결과 324건 처리시간 0.029초

THE ASSESSMENT OF ABUTMENT SCREW STABILITY BETWEEN THE EXTERNAL AND INTERNAL HEXAGONAL JOINT UNDER CYCLIC LOADING

  • Lee, Tae-Sik;Han, Jung-Suk;Yang, Jae-Ho;Lee, Jae-Bong;Kim, Sung-Hun
    • 대한치과보철학회지
    • /
    • 제46권6호
    • /
    • pp.561-568
    • /
    • 2008
  • STATEMENT OF PROBLEM: Currently, many implant systems are developed and divided into two types according to their joint connection: external or internal connection. Regardless of the connection type, screw loosening is the biggest problem in implant-supported restoration. PURPOSE: The purpose of this study is to assess the difference in stability of abutment screws between the external and internal hexagonal connection types under cyclic loading. MATERIAL AND METHODS: Each of the 15 samples of external implants and internal abutments were tightened to 30 N/cm with a digital torque gauge, and cemented with a hemispherical metal cap. Each unit was then mounted in a $30^{\circ}$ inclined jig. Then each group was divided into 2 sub-groups based on different periods of cyclic loading with the loading machine (30 N/ cm - 300 N/cm,14 Hz: first group $1{\times}10^6$, $5{\times}10^6$ cyclic loading; second group $3{\times}10^6$, $3{\times}10^6$ for a total cyclic loading of $6{\times}10^6$) The removal torque value of the screw before and after cyclic loading was checked. SPSS statistical software for Windows was used for statistical analysis. Group means were calculated and compared by ANOVA, independent t-test, and paired t-test with ${\alpha}$=0.05. RESULTS: In the external hexagonal connection, the difference between the removal torque value of the abutment screw before loading, the value after $1{\tims}10^6$ cyclic loading, and the value after $1{\times}10^6$, and additional $5{\times}10^6$ cyclic loading was not significant. The difference between the removal torque value after $3{\times}10^6$ cyclic loading and after $3{\times}10^6$, and additional $3{\times}10^6$ cyclic loading was not significant. In the internal hexagonal connection, the difference between the removal torque value before loading and the value after $1{\times}10^6$ cyclic loading was not significant, but the value after $1{\times}10^6$, and additional $5{\times}10^6$ cyclic loading was reduced and the difference was significant (P < .05). In addition, in the internal hexagonal connection, the difference between the removal torque value after $3{\times}10^6$ cyclic loading and the value after $3{\times}10^6$, and additional $3{\times}10^6$ cyclic loading was not significant. CONCLUSION: The external hexagonal connection was more stable than the internal hexagonal connection after $1{\times}10^6$, and additional $5{\times}10^6$ cyclic loading (t = 10.834, P < .001). There was no significant difference between the two systems after $3{\times}10^6$, and additional $3{\times}10^6$ cycles.

교정용 미니스크류의 디자인에 따른 식립 및 제거 토오크 (Insertion and removal torques according to orthodontic mini-screw design)

  • 차정열;윤태민;황충주
    • 대한치과교정학회지
    • /
    • 제38권1호
    • /
    • pp.5-12
    • /
    • 2008
  • 교정용 미니스크류의 원추 형태가 식립 후 시기별 안정성에 미치는 영향을 알아보기 위해, 시기별 제거 토오크 및 동요도와 조직시편분석을 시행하였다. 성견 6마리의 하악 협측골에 원통형과 원추형 교정용 미니스크류 (Biomaterials Korea, Seoul, Korea) 48개를 식립하고, 식립 시 식립 토오크와 동요도를 측정하고 3주, 12주 동안 교정력을 부여한 후, 제거 시 제거 토오크와 동요도를 측정하였다. 식립 토오크는 원통형 미니스크류에서 13.6 Ncm, 원추형 미니스크류에서 22.3 Ncm 로 원추형 미니스크류에서 높은 식립 토오크가 측정되었다 (p < 0.001). 식립 3주째 제거 토오크는 원통형 미니스크류에서 5.7 Ncm, 원추형 미니스크류에서 9.1 Ncm 로 유의한 차이가 관찰되었다 (p < 0.05). 식립 12주째 원추형 미니스크류의 제거 토오크는 3.6 Ncm 로 유의하게 감소하여 (p < 0.05) 원통형 미니 스크류의 4.2 Ncm 와 유의한 차이를 보이지 않았다. 이상의 결과로 미니스크류의 원추 구조는 식립 토오크를 유의하게 증가시켜 식립 후 3주간 안정성에 도움이 되었으나, 12주 후 안정성에 있어서는 원통형 미니스크류와 유사하였음을 시사한다.

일반노인과 비만노인의 대퇴부 근육량과 근력비교연구(Intermuscular fat을 중심으로) (Comparison of the Thigh Composition and its Functional Contractility in Obese and Nonobese Elderly Patients)

  • 최승준;박성모;곽이섭
    • 생명과학회지
    • /
    • 제24권10호
    • /
    • pp.1125-1131
    • /
    • 2014
  • 본 연구는 65세 이상의 비만노인과 일반노인의 대퇴부 근육량과 등속성 근력을 비교하기 위해 수행되었다. 본 연구의 피험자는 65~79세 사이 노인들을 비만군(BMI>25, N=21)과 일반군(BMI<25, N=13)으로 구성하였다. 본 연구의 목적을 달성하기 위해 대퇴부 근육량 및 지방량 측정 등은 CT 촬영을 통해 측정하였고, 대퇴부 등속성 근력은 BIODEX를 이용해 최대 신전력을 측정하였다. 모든 변인은 two-way ANOVA로 검증한 후 유의한 경우 Contrast test를 통해 사후분석을 실시하였다. 그 결과 대퇴부 총 부피는 남녀 모두 그룹간 유의한 차이가 나타났다. 대퇴부 근육 부피는 비만군 남자가 일반군 남자보다 유의하게 높게 나타났으며 비만군에서 남녀 성별간 유의한 차이를 보였다. 피하지방은 그룹간과 그룹내 성별간 유의한 차이가 나타났으며, 근간지방의 경우 비만군과 일반군의 동일 성별간에서만 유의한 차이가 나타났다. 또한 근간지방은 일반군 남자에서 비만인 남자에 비해 유의하게 높게 나타났으며 성별간 유의한 차이도 확인되었다. 이상의 연구 결과를 종합해보면 비만 노인은 일반노인보다 남녀 모두 큰 대퇴부 근육 부피를 가지고 있음에도 불구하고, 단위 체중당 대퇴부 근력은 일반노인이 높은 것으로 나타났다. 이는 비만노인에 비해 일반노인의 근육기능이 생리적으로 더 우수하다는 것을 의미한다.

슬관절의 자세에 따른 족관절 저측굴곡근의 등속성 근력 평가 (Isokinetic Evaluation of Plantarflexors with Knee Position)

  • 배성수;이현옥;이근희
    • The Journal of Korean Physical Therapy
    • /
    • 제12권2호
    • /
    • pp.145-152
    • /
    • 2000
  • 슬관절 자세에 따라 족관절 저측굴곡관의 근력을 비교 분석하기 위하여 건강한 남녀 20명을 대상으로 Cybex 6000을 사용하여 측정한 결과는 다음과 같다. 1. 최대 토오크 값은 양쪽 모두 슬관절 신전상태서 $90^{\circ}$ 굴곡에서보다 높았다. 슬관절 신전상태에 대한 $90^{\circ}$ 굴곡에서의 토오크 값의 비는 운동속도 $30{\circ}/sec$$90{\circ}/sec$에서 각각 $75.7\%\;85.2\%$였다. 2. 최대 토오크는 $30{\circ}/sec\;90^{\circ}/sec$에서 모두 슬관절 신전상태에서 $90^{\circ}$ 굴곡상태에서보다 운동의 초기에서 나타났으나 유의란 차이는 업었다. 3. 저측룰곡근의 총일량은 굴곡보다 신전상태서 높았다. 슬관절 신전상태 대한 $90^{\circ}$ 굴곡에서의 총일량의 비는 운동속도 $30{\circ}/sec$$90{\circ}/sec$에서 각각$81\%,\;89\%$였다. 4 저측굴곡근의 근지구력은 슬관절 신전상태와 $90^{\circ}$ 굴곡상태애서 $78.35\%,\;92.70\%$로 굴곡상태에서 높았다. 5. 일률은 $30{\circ}/sec$에서 슬관절 신전에서 높았다. 위 연구 결과는 족관절 손상환자의 물리치료 시에 배 측굴곡근과 저측굴곡근의 근력 비와 더불어 근재교육에 유용한 자료로 사용될 수 있을 것으로 사료된다. 또한 근력증가를 위한 목적으로 운동치료 시 슬관절 신전상태에서의 저측굴곡운동이 더 효율적인 방법이라 생각된다.

  • PDF

파라미터 맵을 이용한 차량용 인휠 전동기의 설계 (Design of In-Wheel Motor for Automobiles Using Parameter Map)

  • 김해중;이충성;홍정표
    • 한국자기학회지
    • /
    • 제25권3호
    • /
    • pp.92-100
    • /
    • 2015
  • 전기자동차는 구동방식에 따라 인휠(in-wheel) 방식과 인라인(in-line) 방식으로 구분될 수 있다. 인휠 방식 전기자동차는 기존의 자동차에서 사용하였던 변속기, 축, 차동기어 등을 제거 할 수 있기 때문에 구조가 간단해지고 차체를 경량화하여 효율을 증대시킬 수 있는 장점이 있다. 본 논문에서는 파라미터 맵(parameter map)을 이용한 차량용 인휠 전동기의 설계 방법을 제시하고, 연속정격 5 kW급 전동기를 설계하여 제작 및 성능 검증을 한다. 우선 차량의 요구 성능을 만족하는 인휠 전동기의 용량을 결정하기 위해 차량의 총무게, 기어 효율, 바퀴의 등가반경, 등판각도 등을 고려한 차량동특성해석을 수행한다. 이것을 통해 전동기 용량을 결정하고, 전동기 형상 및 치수를 결정하기 위한 초기설계를 진행한다. 그리고 요구 성능을 만족하는 전동기 파라미터를 결정하기 위해 파라미터 맵을 이용한 파라미터 설계를 수행한다. 파라미터 맵을 통해 전동기 파라미터를 결정한 후 마지막으로 무부하역기전력의 왜형율(Total Harmonic Distortion, 이하 THD), 코깅토크(cogging torque), 토크리플(torque ripple) 등의 개선을 위해 최적설계를 수행한다. 최종 설계 모델에 대해 제작을 하였으며, 성능 검증 및 제시한 설계방법의 신뢰도 검증을 위해 부하시험을 진행한다.

만성요통 여교사에 대한 운동프로그램의 효과 - 근력, 근지구력, 유연성, 통증, 기능장애, 우울 및 생활만족도를 중심으로 - (The Effect of Exercise Program on Chronic Low Back Pain in Female Teachers of Elementary School)

  • 최순영
    • 여성건강간호학회지
    • /
    • 제7권2호
    • /
    • pp.169-187
    • /
    • 2001
  • This study was performed to probe the effect of exercise program on muscle strength, endurance, flexibility, pain, disability level and life satisfaction in female teachers of elementary school who complain of low back pain. For this study, 44 female teachers aged 30-50 years with mechanical low back pain of 6 months' duration, who had the structural normalities in the lumbar spine, were recruited from April 1 to July 10 1999. Twenty three out of them were assigned to the experimental group and twenty one to the control group. The exercise program consisted of education on right postures, the etiology and diagnosis of low back pain, and exercise intervention such as muscle relaxation, elongation and strengthening. With 8 weeks program, the subjects received two sessions of education and six sessions of group exercise in the 1st week, while three sessions of group exercise and four sessions of individual exercise weekly and two sessions of education during the later 7 weeks. The muscle strength and endurance were measured by Cybex 770, the flexibility by flexibility measurement machine, the intensity of pain by Visual Analogue Scale (VAS), the level of disability by Oswestry low back pain disability scale, depression by Beck depression inventory (BDI), and life satisfaction by Life satisfaction index-Z. Study measurements were taken before and after 8 weeks exercise program. Data were analyzed using paired t-test, t-test, and ANCOVA. The results were as follows ; 1. The flexors and extensors peak torque and flexors peak torque per body weight of experimental group were significantly increased at test velocities $30^{\circ}$/sec, $60^{\circ}$/sec compared with those of control group. There was no significant difference in extensors peak torque per flexors peak torque at $30^{\circ}/sec$, $60^{\circ}/sec$ between experimental and control group. 2. The flexors and extensors total work and flexors total work per body weight of experimental group were significantly increased at $120^{\circ}/sec$, compared with those of control group. 3.The flexibility of lumbar spine in experimental group was significantly increased compared with that of control group. The pains in anterior, posterior, left lateral and right lateral bending and in rotation of experimental group were significantly increased compared with those of control group. 4. The Oswestry disability scores of experimental and control group were significantly decreased, and there was no difference in the Oswestry disability score change between experimental and control group. 5. The scores of BDI of experimental group were significantly decreased compared with those of control group. Life satisfaction index-Z scores of experimental group were not changed, but those of control group were significantly decreased. There was no difference in the score change of Life satisfaction index-Z between experimental and control group. 6. ANCOVA analysis for the data variables of inhomogeneous baseline represented that there was no significant difference in extensors peak torque and extensors total work at $120^{\circ}/sec$ and extensor total work per body weight at $120^{\circ}/sec$ change between experimental group and control group. These findings indicate that the exercise program could be effective in increasing the muscle strength, endurance, flexibility and decreasing pain, improving depression in female teachers of elementary school with chronic low back pain. It is suggested that the exercise program could be an essential factor for the effective nursing intervention to the patients suffered from chronic low back pain.

  • PDF

남성에서 두피 전층 결출 손상의 치험례 (A Clinical Experience of Total Scalp Avulsion in a Male)

  • 송제니퍼김;김민욱;황소민;임광열;정용휘;안성민
    • Archives of Reconstructive Microsurgery
    • /
    • 제20권1호
    • /
    • pp.74-77
    • /
    • 2011
  • Total scalp avulsion is rare but a devastating injury. This condition burdens the patient with disfigured cosmetic appearance and permanent psychosocial trauma. Throughout history, this condition has been favored in women working with mechanics since the long hair function as a vector appliance for oblique pull of the hair into a stationary torque. We present our experience of the replantation of the total avulsed scalp in male, first to be reported in Korea. Warm ischemic time was exceeding 16 hours along with severe crushed condition of the detached margin, a relatively satisfactory result was obtained.

  • PDF

20대 남자대학생의 몸통회전에 대한 등속성운동 검사에 관한 연구 (The Study of Isokinetic Exercise Test of Trunk Rotation of 20's Male College Students)

  • 최병옥
    • 대한정형도수물리치료학회지
    • /
    • 제12권2호
    • /
    • pp.21-25
    • /
    • 2006
  • Objective: The purposes of this study are to provide fundamental data and a rehabilitation program in physical therapy. It has been operated by 30 male college students for lumbar isokinetic exercises. Method : Subjects have been carried out in an experiment by Biodex system operating isokinetic torso rotation. This performance was activated by left rotation after right rotation repeatedly. Results: 1. The mean peak torques at $60^{\circ}$/sec were $95.6{\pm}20.62$ (Rt) and $93.84{\pm}18.41$ (Lt). 2. The mean peak torques/body weight at $60^{\circ}$/sec were $69.28{\pm}28.31$ (Rt) and $67.07{\pm}27.04$ (Lt). 3. The total works in right side at $60^{\circ}$/sec and $180^{\circ}$/sec were $492.21{\pm}92.37$, $1294.97{\pm}278.96$ and in left side at $60^{\circ}$/sec and $180^{\circ}$/sec were $515.78{\pm}109.47$, $1443.74{\pm}329.67$. 4. The work to body weight ratio at $60^{\circ}$/sec was $78.30{\pm}32.37$ (Rt) and $79.93{\pm}37.30$ (Lt). 5. The average powers in right side at $60^{\circ}$/sec and $180^{\circ}$/sec were $76.75{\pm}16.69$, $117.19{\pm}29.94$ and in left side at $60^{\circ}$/sec and $180^{\circ}$/sec were $78.54{\pm}18.58$, $125.39{\pm}32.90$. 6. The work fatigue at $180^{\circ}$/sec was $21.76{\pm}14.82$ (Rt) and $19.66{\pm}26.23$ (Lt). Conclusion: In right side and left side, there was no significant difference in peak torque. peak torque/body weight, work to body-weight ratio, average power of trunk rotators at $60^{\circ}$/sec(p<0.05). However there was a significant difference in the total work of trunk rotators at $60^{\circ}$/sec(p>0.05). Also there was a significant difference in the average of trunk rotators at $180^{\circ}$/sec(p>0.05).

  • PDF

인조골에서 식립 방법이 교정용 미니 임플란트의 기계적 안정성에 미치는 영향에 대한 예비연구 (The effects of different pilot-drilling methods on the mechanical stability of a mini-implant system at placement and removal: a preliminary study)

  • 조일식;추혜란;김성균;신윤섭;김덕수;김성훈;정규림;존황
    • 대한치과교정학회지
    • /
    • 제41권5호
    • /
    • pp.354-360
    • /
    • 2011
  • Objective: To investigate the effects of different pilot-drilling methods on the biomechanical stability of self-tapping mini-implant systems at the time of placement in and removal from artificial bone blocks. Methods: Two types of artificial bone blocks (2-mm and 4-mm, 102-pounds per cubic foot [102-PCF] polyurethane foam layered over 100-mm, 40-PCF polyurethane foam) were custom-fabricated. Eight mini-implants were placed using the conventional motor-driven pilot-drilling method and another 8 mini-implants were placed using a novel manual pilot-drilling method (using a manual drill) within each of the 2-mm and 4-mm layered blocks. The maximum torque values at insertion and removal of the mini-implants were measured, and the total energy was calculated. The data were statistically analyzed using linear regression analysis. Results: The maximum insertion torque was similar regardless of block thickness or pilot-drilling method. Regardless of the pilot-drilling method, the maximum removal torque for the 4-mm block was statistically higher than that for the 2-mm block. For a given block, the total energy at both insertion and removal of the mini-implant for the manual pilot-drilling method were statistically higher than those for the motor-driven pilot-drilling method. Further, the total energies at removal for the 2-mm block was higher than that for the 4-mm block, but the energies at insertion were not influenced by the type of bone blocks. Conclusions: During the insertion and removal of mini-implants in artificial bone blocks, the effect of the manual pilot-drilling method on energy usage was similar to that of the conventional, motor-driven pilot-drilling method.

새로운 타이타늄 구성요소를 사용한 내부연결 임플란트용 지르코니아 지대주의 동적하중 후 나사 제거력 (Removal torque of a two-piece zirconia abutment with a novel titanium component in an internal connection implant system after dynamic cyclic loading)

  • 이주희
    • 대한치과보철학회지
    • /
    • 제55권2호
    • /
    • pp.151-155
    • /
    • 2017
  • 목적: 이 연구의 목적은 새로운 타이타늄 구성요소를 가진 지르코니아 지대주의 나사 제거력의 변화에 대해 알아보는 것이다. 내부연결 임플란트를 위한 새로운 지르코니아 지대주의 동적하중 후 지대주 나사의 제거력을 기존의 타이타늄 지대주와 비교하여 분석하였다. 재료 및 방법: 내측연결 임플란트와 타이타늄 지대주, 타이타늄 구성요소를 가진 지르코니아 지대주를 준비하였다. 12개의 내부연결형 임플란트에 6개의 타이타늄 지대주를 연결하고(대조군), 6개의 타이타늄 구성요소를 가진 지르코니아 지대주(실험군)를 30 Ncm의 토크로 연결한 후 동적하중 전후의 나사 제거력을 측정하였다. 동적 만능재료시험기를 사용하여 연결체의 장축과 30도 각도를 이루도록 하고 300 N 하중크기로 100만번의 하중이 가해졌다. 동적하중 전후의 지대주 나사 제거력을 t검정을 통해 신뢰구간 95%로 통계적 유의성을 검증하였다. 결과: 두 그룹 모두에서 동적하중 후 나사 풀림을 보이지 않았다. 동적 하중 전후의 나사 제거력은 두 그룹 모두에서 통계적으로 유의한 차이가 있게 나타났다(P < .05). 동적 하중 전후의 나사 제거력 차이는 대조군에서 $-7.25{\pm}1.50Ncm$, 실험군에서 $-7.33{\pm}0.93Ncm$ 로 나타났다. 통계분석 결과 두 군간에 나사 제거력 차이에서는 유의한 차이를 보이지 않았다(P > .05). 결론: 이 실험의 결과에 한하여 타이타늄 구성요소를 사용한 지르코니아 지대주의 동적하중 후 지대주 나사 제거력의 변화는 타이타늄 지대주와 통계학적으로 유의한 차이를 보이지 않았다.