• 제목/요약/키워드: total insulation

검색결과 211건 처리시간 0.029초

한국 남성용 단일의복의 앙상블 조합시의 온열특성 변화에 관한 연구 - 무풍, 풍속환경하에서 - (A Study on Changes in Thermal Performances in Ensembles Made up of Single Garments Marketed for Korean Men - In Still and Dynamic Air Conditions -)

  • 송민규;권서윤;정현미
    • 한국의류산업학회지
    • /
    • 제14권4호
    • /
    • pp.660-668
    • /
    • 2012
  • The purpose of this study is to analyze the thermal characteristics of garments marketed for Korean males and to investigate the influence of each garment on ensemble, by measuring their insulation values(clo) using thermal manikins. The results are as follows. The total insulations(clo) of ensembles for S/S seasons are between 1.46 and 2.6 clo, with the mean of 2.12 clo. The insulation in the still air condition is 1.23 clo, which means a decrease of 42% compared to the total insulation of all the component garments. The insulation of ensembles for S/S seasons in the dynamic air condition decreased by 46.8%, compared to the still air condition. The total insulation(clo) of ensembles for F/W seasons is between 3.84 and 7.36 clo with the mean of 4.74 clo. The insulation in the still air condition is 2.26 clo, which means a decrease of 53.6% compared to the total insulation of all the component garments. The insulation of ensembles for F/W seasons in the dynamic air condition decreased by 36.2%, compared to the still air condition. As the clo value of each component garment gets higher, the insulation of ensembles gets higher. Especially, the insulation of ensembles was more influenced by outer wear than inner wear. The insulation of ensembles could be predicted by the insulation of outerwear better.

전력용 변압기 절연유희 비파괴 진단 시험법 비교연구 (A Comparative Study on the Non-Destructive Diagnostic Methods of the insulation Oils in Power Transformer)

  • 이준호;이동영;최종갑;김재철;곽희로;권태원;한민구
    • 대한전기학회논문지
    • /
    • 제40권8호
    • /
    • pp.799-807
    • /
    • 1991
  • The various degradation phenomena, such as the evolution of gases, tan e, moisture content and total acid number in insulation oils of power transformer have been measured and analyzed as a function of aging temperatures and periods. The insulation oils have been degraded at laboratory in the period of 17, 34, and 72 days. We have also extracted the insulation oils from the working power transformers. The dissolved gases (such as CO, CO2, H2, CH4 C2H2---), tane, moisture content and total acid number in laboratory samples and field samples have been measured and characterized. It has been found that gases increase with degradation temperature and tane increases with total acid number while the moisture content does not increase with tane.

  • PDF

한국 성인 여성의 계절별 의복조합과 보온력과의 관련성 - 써멀마네킨 실험에 의한 - (Relationship between Thermal Insulation and the Combinations of Korean Women's Clothing by Season - Using a Thermal Manikin -)

  • 최정화;고은숙
    • 한국의류학회지
    • /
    • 제31권6호
    • /
    • pp.966-973
    • /
    • 2007
  • 본 연구에서는 한국 성인여성의 각 계절별 실제 착용하는 한 벌 의복조합과 보온력간의 상관관계를 알아보고자 하였다. 설문조사한 결과를 토대로, 총 34벌의 한 벌 의복과 이를 구성하는 단일의복 43종을 선정하여 써멀 마네킨을 이용하여 보온력을 측정하였고, 다음과 같은 결과를 얻었다. 한 벌 의복의 보온력은 봄가을(8벌) $0.34{\sim}0.60clo$, 여름(7벌) $0.16{\sim}0.37clo$, 겨울(19벌) $0.89{\sim}1.35clo$였다. 단일의복 보온력의 단순가산치와 한 벌 의복의 보온력간의 상관계수는 0.982(p<0.001)이며, 써멀 마네킨에 의해 측정된 한 벌 의복의 보온력과 상의 착의 매수간의 상관계수는 0.750(p<0.001)이고 의복 총중량과의 상관계수는 0.978(p<0.001), 피복면적과의 상관계수는 0.776(p<0.001)이었다. 한 벌 의복의 보온력과 의복요인과의 상관관계에서 단일의복 보온력의 단순가산치와 의복총중량이 가장 높은 상관을 보였다.

가스량, Tan $\delta$, 수분량, 전산가에 의한 유침 전력 변압기의 열화현상에 관한 연구 (The degradation of insulation oil in power transformers by the evolution of gases, Tan $\delta$, moisture and total acid number)

  • 최종갑;한민구;권태원;윤용범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1989년도 추계학술대회 논문집 학회본부
    • /
    • pp.159-163
    • /
    • 1989
  • The various degradation phenomena, such as the evolution of gases, tan $\delta$, moisture content and total acid number in power transformer insulation oil, have been measured and analyzed. Mineral oil has been degraded at laboratory by the forced thermal stress of $60^{\circ}C$ and $90^{\circ}C$ respectively. Thermal aging oil has been degraded about 17, 34, 72 days. Also, we extracted insulation oil from working transformers. We measured gases dissolved in samples, tan $\delta$, moisture content, total acid number. Activation energy and resistivity is calculated from them. It is found that gases and tan $\delta$ increases as partial discharge and total acid number increases and that conductivity of the sample increases as activation energy increases.

  • PDF

The Effect of Adjustable Garment Closures and Layering on Insulation in Cold Weather

  • Kim, Chil-Soon;McCullough, Elizabeth
    • 한국의류산업학회지
    • /
    • 제3권5호
    • /
    • pp.479-485
    • /
    • 2001
  • This study was to determine the effect of garment closures and layering systems on insulation, using a thermal movable manikin in cold weather conditions. The insulation values of ensembles with opened and closed features were measured, and those of four different layered clothing ensembles were tested while standing and while walking. Our research indicated that when there was an opening involved in design the system, insulation decreased; even a zip-out lining in the armpit affected little. If a light weight jacket and pants are put on over a fleece shirt and pants instead polyester underwear, the amount of insulation increase was 0.43 clo.

  • PDF

Optimization approach of insulation thickness of non-vacuum cryogenic storage tank

  • MZAD, Hocine;HAOUAM, Abdallah
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제22권1호
    • /
    • pp.17-23
    • /
    • 2020
  • Cryogenic insulation systems, with proper materials selection and execution, can offer the highest levels of thermal performance. Insulations are listed in order of increasing performance and, generally, in order of increasing cost. The specific insulation to be used for a particular application is determined through a compromise between cost, ease of application and the effectiveness of the insulation. Consequently, materials, representative test conditions, and engineering approach for the particular application are crucial to achieve the optimum result. The present work is based on energy cost balance for optimizing the thickness of insulated chambers, using foamed or multi layered cryogenic shell. The considered insulation is a uniformly applied outer layer whose thickness varies with the initial and boundary conditions of the studied vessel under steady-state radial heat transfer. An expression of the optimal insulation thickness derived from the total cost function and depending on the geometrical parameters of the container is presented.

An Experimental Study on the Evaluation of Fastening Unit Insulation Developed for the Insulation of Curtain Wall

  • Kim, Bong-Joo;Kim, Kyeong-A
    • 한국건축시공학회지
    • /
    • 제12권2호
    • /
    • pp.243-256
    • /
    • 2012
  • This study is the experimental study to improve the insulation of the fastening unit system, which has the most vulnerable insulation in the curtain walls. The Fastening Units were designed and fabricated to minimize the connection part of mullions. In addition, slight movements were taken into account and the performance of the middle layer was evaluated by forming an insulation layer with the vibration-proof rubber and the silicon to satisfy the mechanical and thermal performance criteria. A total of 10 experiments were performed under various conditions, such as indoor-outdoor temperature difference, type of insulation material, thickness of insulation material, and others. using the fabricated Fastening Units. As a result, the vibration-proof rubber insulation showed the temperature difference of $2.2^{\circ}C-5.0^{\circ}C$, and the silicon insulation showed the temperature difference of $2.8^{\circ}C-4.5^{\circ}C$, compared to the non-insulated Fasteniirature difference, typesng Units. When these results were compared with the psychometric chart graph, the insulated Fastening Unit designed in this study can be considered to prevent the dew condensation.

Influence of Electrical Aging on Space Charge Dynamics of Oil-Impregnated Paper Insulation under AC-DC Combined Voltages

  • Wang, Yan;Li, Jian;Wu, Sicheng;Sun, Peng
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권6호
    • /
    • pp.1512-1519
    • /
    • 2013
  • Oil-impregnated paper is a major type of insulation used in oil-filled converter transformers for both traditional and new energy systems. This paper presents and analyzes the results of the experiment conducted on the electrical aging of oil-impregnated paper under AC-DC combined voltages using the pulsed electro-acoustic (PEA) technique. The formation and dynamics of space charge affected the performance of insulation material. The electrical aged oil-paper insulation was obtained through electrical aged experiments under the voltages. Based on the PEA technique, measurements were carried out when the oil-paper insulation system was subjected to different stressing and aging times. The space charge dynamics in the bulk of the oil-paper insulation system with different aging times were measured and analyzed. Characteristic parameters such as the total charge injection amount, the total charges of fast moving and slow moving, and the distortion factor of electric field were calculated and discussed. Results show that the longer electrical aging time, the more charges trapped in the bulk of aging sample. It leads to larger distortion factor of electric field in the bulk of aging samples and accelerate degradation of oil-paper insulation under AC-DC combined voltages.

공동주택에서의 창호성능에 따른 건물에너지 효율등급 평가 연구 (A Study on the Evaluation of Building Energy Rating considering the Insulation performance of the Window in Apartment houses)

  • 김치훈;안병립;홍성희;장철용
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 춘계학술발표대회 논문집
    • /
    • pp.291-295
    • /
    • 2009
  • As a reasonable energy policy has become required because of consuming substantial amounts of oil than others, the studies on energy consumption are in work for energy savings of buildings that spend up to 24% of total energy consumption. However, there aren't basic data on energy consumption and installationregulations for effective equipments in energy guzzled buildings. The best plan to reduce the building energy consumption is that the insulation performance should be improved because the insulation and airtight of building envelopes have an effect on the energy consumption basically. Thus, we should prepare the alternatives to improve insulation performance of envelopes and the efficiency of insulation performance of the window for reducing energy consumption.

  • PDF

남부지역 주거건물의 외피단열변화에 따른 에너지소비량 예측 (Prediction of the Amount of Energy Consumption by Variation in Envelope Insulation on a Detached House in Southern Part of Korea)

  • 문진우;한승훈;오세규
    • 한국주거학회논문집
    • /
    • 제22권1호
    • /
    • pp.115-122
    • /
    • 2011
  • This study aimed at quantifying the impact of envelope insulation on energy consumption for thermal controls in residential buildings in southern part of Korea. A series of parametric simulations for a range of R-values of walls, roof, floor, and windows were computationally conducted for a prototypical Korean detached house. Analysis revealed that the total amount of heat gain was larger than that of heat loss, while the amount of energy for cooling was smaller than that for heating due to the difference of system efficiency; the envelope heat transfer was more significant for the heat loss, thus, the increase of the envelope insulation was more effective to reduce heating load; and there were certain levels of envelope insulation after which the energy saving effect was not significant. These findings are expected to be a fundamental database for the decision of proper insulation level in Korean residential buildings.