• Title/Summary/Keyword: total correction

Search Result 756, Processing Time 0.048 seconds

A study On the Switching Technique of Boost Converter for Harmonic Reduction (부스트컨버터의 고조파저감을 위한 스위칭 기법에 관한 연구)

  • Shon, Jin-Geun;Chu, Sun-Nam;Kim, Young-Hyuk;Lee, Sang-Cheol;Lee, Bok-Yong
    • Proceedings of the KIEE Conference
    • /
    • 2000.07e
    • /
    • pp.74-78
    • /
    • 2000
  • In this paper a switching control circuit for shaping the line current and reducing the total harmonics distortion in the boost converter is presented. To solve the problems of performance degradation due to pulse waveform in the input current, the boost converter in which the harmonic distortion in the input current is reduced using a 3th harmonic-injected PWM is proposed. Finally, Simulation and experimental results of boost converter with 5[kHz] switching frequency are presented and correction of power factor and reduction of total harmonic distortion was established.

  • PDF

A Study on the Five - hole Probe Calibration with Non-nulling Method (비영위법에 의한 5공 프로브의 교정에 관한 연구)

  • Jeong, Yang Beom;Sin, Yeong Ho;Park, Ho Dong
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.20 no.2
    • /
    • pp.116-116
    • /
    • 1996
  • This paper is concerned with a method for calibrating five-hole probes of both angle-tube and prismatic geometries to measure local total and static pressures and the magnitude and direction of the mean velocity vector. Descriptions of the calibration technique, the typical calibration data, and an accompanying discussion of the interpolation procedure are included. The flow properties are determined explicitly from measured probe pressures using calibration data. Flow angles are obtained within the deviation angle of 1.0 degree and dynamic pressures within 0.03 with 95% certainty. The variations in the calibration data due to Reynolds number are also discussed. For the range of Reynolds number employed, no effect was detected on the pitch, yaw and total pressure coefficients. However, the static pressure coefficient showed change to cause minor variations in the magnitude of the calculated velocity vector. To account for these variations, average correction factors need to be incorporated into the static pressure coefficient.

A Study on the Five-hole Probe Calibration with Non-nulling Method (비영위법에 의한 5공 프로브의 교정에 관한 연구)

  • 정양범;신영호;박호동
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.20 no.2
    • /
    • pp.48-56
    • /
    • 1996
  • This paper is concerned with a method for calibrating five-hole probes of both angle-tube and prismatic geometries to measure local total and static pressures and the magnitude and direction of the mean velocity vector. Descriptions of the calibration technique, the typical calibration data, and an accompanying discussion of the interpolation procedure are included. The flow properties are determined explicitly from measured probe pressures using calibration data. Flow angles are obtained within the deviation angle of 1.0 degree and dynamic pressures within 0.03 with 95% certainty. The variations in the calibration data due to Reynolds number are also discussed. For the range of Reynolds number employed, no effect was detected on the pitch, yaw abd total pressure coefficients. However, the static pressure coefficient showed change to cause minor variations in the magnitude of the calculated velocity vector. To account for these variations, average correction factors need to be incorporated into the static pressure coefficient.

  • PDF

A Salvage Operation for Total Penis Amputation Due to Circumcision

  • Ince, Bilsev;Gundeslioglu, Ayse Ozlem
    • Archives of Plastic Surgery
    • /
    • v.40 no.3
    • /
    • pp.247-250
    • /
    • 2013
  • Circumcision is one of the most common rituals in Jewish and Islamic cultures. It may also be performed for phimosis correction or the treatment of recurrent balanitis. Although circumcision is considered to be a technically easy and safe surgical procedure with no significant risk, it may lead to severe complications such as necrotizing fasciitis or total penis amputation. In this report, we present a case of penis amputation at two levels occurring with third-degree burns due to electrocautery during circumcision. Although penile replantation was attempted, it was unsuccessful due to burn damage to the veins. After restoration of the functional structures, the penis was buried in the inguinal area by reepithelization to maintain blood circulation. The recovery of the penis was successful. This case is presented as a novel example of groin flap surgery to achieve a functionally and aesthetically acceptable outcome in a salvage operation for a penis with significant traumatic injury, which has not been previously reported in the literature.

Total Solution System for Applications using DPMS (DPMS 통합 원서 지원 시스템 개발)

  • Park, Chang-Ho;Hwang, Hu-Mor
    • Proceedings of the KIEE Conference
    • /
    • 2001.07d
    • /
    • pp.2678-2680
    • /
    • 2001
  • We develop a total solution system for applications, which is called a data processing module system(DPMS), based on ASP, PDF, JAVA, and MSSQL. The DPMS system provides a realtime telematic guidance in the fields of application, recruiting, and management. The user documents the PDF file on the Web browser and store the file in DB for correction. The DPMS discovered the difficulties in data input due to 2 byte problem of Korean language. This result leads to the usage of Korean language as well as others. Test results through free-charge access confirm that the DPMS outperforms the conventional systems based on ASP with HTML in view of simplicity and confidentiality.

  • PDF

A Wafer Pre-Alignment System Using One Image of a Whole Wafer (하나의 웨이퍼 전체 영상을 이용한 웨이퍼 Pre-Alignment 시스템)

  • Koo, Ja-Myoung;Cho, Tai-Hoon
    • Journal of the Semiconductor & Display Technology
    • /
    • v.9 no.3
    • /
    • pp.47-51
    • /
    • 2010
  • This paper presents a wafer pre-alignment system which is improved using the image of the entire wafer area. In the previous method, image acquisition for wafer takes about 80% of total pre-alignment time. The proposed system uses only one image of entire wafer area via a high-resolution CMOS camera, and so image acquisition accounts for nearly 1% of total process time. The larger FOV(field of view) to use the image of the entire wafer area worsen camera lens distortion. A camera calibration using high order polynomials is used for accurate lens distortion correction. And template matching is used to find a correct notch's position. The performance of the proposed system was demonstrated by experiments of wafer center alignment and notch alignment.

Correction Measures That Take Humidity into Account in Insulating Oil Test Measurement Results (습도를 고려한 절연유 시험 결과의 보정 방안 연구)

  • Wansu Kim;Jae-pil Roh;Seock-gu Kang
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.37 no.5
    • /
    • pp.541-546
    • /
    • 2024
  • Climate conditions, especially transport and storage, are a very important factor in the process of sampling and testing insulation oil in the field. The samples of insulating oil exposed to the atmosphere affect the dielectric strength, total acid number and moisture test value by oxygen and high humidity environment and may also affect the results according to the criteria specified in each test. Therefore, reliable test values for insulating oil testing require consideration of the atmospheric environment of the test site, including oxygen and humidity. In this paper, each test was conducted on insulating oil exposed to various time and humidity environments, and the effect of the atmospheric environment on the test results was analyzed by comparing and analyzing with the first insulating oil.

Surgical and Long Term Results for Double Outlet Right Ventricle by the Type of Ventricular Septal Defect (심실중격결손의 형태에 따른 양대혈관 우심실기시증의 수술 및 장기 결과)

  • Yu Song Hyeon;Park Han Ki;Cho Bum Koo;Park Young Hwan
    • Journal of Chest Surgery
    • /
    • v.38 no.3 s.248
    • /
    • pp.181-190
    • /
    • 2005
  • The results of biventricular repair for double outlet right ventricle have been improved in recent series. We studied the surgical and long term results for total correction of double outlet right ventricle by the type of ventricular septal defect. Material and Method: Between November 1979 and December 2003, 126 patients had biventricular repair for double outlet right ventricle. The mean age was 1.8 years (range 1$\~$44) and 86 patients ($68.3\%$) were male. We classified and studied this disease by the type of VSD. Result: The locations of VSD were subaortic in 79 ($62.7\%$), subpulmonary in 17 ($13.5\%$), doubly committed in 16 ($12.7\%$) and noncommitted in 14 ($11.1\%$). 28 patients had palliative operation before total correction and the mean interval to total correction was 41.0$\pm$45.1 months. The methods of total correction were intraventricular baffling in 37 ($29.4\%$), intraventricular baffling with patch enlargement of right ventricular outflow tract in 49 ($38.9\%$), intraventricular baffling with Rastelli procedure in 15 ($11.9\%$), arterial switch operation in 8 ($6.3\%$) and REV procedure in 4 ($3.2\%$), etc. Hospital mortality rate was $10.3\%$ (13 patients) and 25 reoperations were performed in 24 patients ($19.0\%$). The risk factors for hospital mortality and reoperation were cardiopulmonary bypass time (p=0.020) and previous palliative operation (p=0.013), respectively. Follow up was possible in 98 patients and mean follow up period was 118.9$\pm$70.7 months. The percent survival and survival for freedom from reoperation at 15 years were $82.5\%$ and $66.7\%$, respectively. The survival rate was significantly lower (p=0.003) in transposition of great artery type and remote type than in simple ventricular septal defect type and tetralogy of Fallot type, but there was no statistical differences in survival rate for freedom from reoperation. Conclusion: It is thought to be that acceptible surgical and long term results can be obtained with application of appropriate methods of repair for double outlet right ventricle.

Radiologic Evaluation of Change of Ankle Joint after Total Knee Arthroplasty (인공 슬관절 치환술 후 족관절 변화에 대한 방사선학적 연구)

  • Bae, Su-Young;Kim, Hee-Chun;Park, Young-Soo;Lee, Sang-Eun;Lee, Don-Seok
    • Journal of Korean Foot and Ankle Society
    • /
    • v.11 no.2
    • /
    • pp.135-140
    • /
    • 2007
  • Purpose: To evaluate the incidence and describe radiologic pattern of ankle arthritis following change of mechanical loading axis by total knee arthroplasty. Materials and Methods: We reviewed radiographs of 419 cases, 243 patients underwent total knee arthroplasy from January 2002 to October 2006 retrospectively. We described radiologic parameters around the ankle joint and measured the amount of change of knee varus or valgus angle by comparing preoperative and postoperative anteroposterior standing lower extremities AP X-rays. We divided cases into two groups, one with radiologically arthritic change of the ankle joint and the other one without any radiologic change after surgery. We compared two groups in each parameters and analyzed statistically (SPSS v13.0). Results: Three hundred eighty one cases were divided into varus group and 38 cases in valgus group. 125 cases were divided into ankle arthritic change-positive subgroup among the varus group and 251 cases were in negative subgroup. The amount of varus angle correction by total knee arthroplasty showed significant difference between two subgroups. There was no significant difference in each parameters between subgroups within 38 valgus cases. Conclusion: Ankle arthritis can be aggravated after total knee arthroplasty because of the change of mechanical loading axis onto the ankle joint. Therefore it may be needed to evaluate symptoms and function of ankle joints before performing total knee arthroplasties especially in patients with huge varus deformities of knee joints.

  • PDF

Correction of an unusual abnormal buccal frenum by Total Palatal Mucosal Free Graft : A Case Report (Total Palatal Mucosal Free Graft를 이용한 비정상 협소대 치험 1예)

  • Park, Hyung-Sik;Kim, Sun-Yong;Lee, Sang-Hye
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.12 no.3
    • /
    • pp.42-48
    • /
    • 1990
  • This is a case report on an unusual - heavy buccal frenum in young lady which was treated by frenectomy, vestibuloplasty and total-palatal mucosal free graft. The authors noticed that this abnormal condition lead several chronic complications in young patient as like as premature loss of upper molar teeth, early and rapid loss of alveolar bone around insertion of frenum, over - extended eruption of lower molar teeth and abnormal mandibular movements, etc. After frenectomy and surgical extension of buccal vestiblue on both upper and lower posterior regions, we obtained a full - sized palatal mucosal graft and moved it on upper and lower extension area seperately as two pieces of free grafts to offer inherent function of denture - bearing mucogingiva and same color - matching with oral mucosa and to prevent post - operative relapse of vestibular height. We discussed here about unusual abnormality and their complications of unusual buccal frenum and its treatment.

  • PDF