• Title/Summary/Keyword: total ankle joint prosthesis

Search Result 2, Processing Time 0.016 seconds

Surface Tribology of Total Ankle Joint Replacement (인공발목관절의 표면 마모 특성)

  • Jeong, Yong-Hoon;Jung, Tae-Gon;Yang, Jae-Woong;Park, Kwang-Min;Lee, Su-Won
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2016.11a
    • /
    • pp.117-117
    • /
    • 2016
  • Total ankle replacement (TAR) is a visible option in the surgical treatment of degenerative or inflammatory diseases of ankle joint. it is attributed to the current TAR which has improvements in surgical technique, uncemented implant fixation and minimally constrained articulation. In the clinical result, they can show promised surgical result when compared to earlier attempts in TAR. However, TAR is still not as successful as total knee replacement (TKR) or total hip replacement (THR), it needs to be note that there are limitations in concerning of long term performance of TAR, the high failure rate still associated with wear of the PE (polyethylene) component that has related with their material property and surface roughness. The aim of this study was to introduce the tribology characteristics of total ankle joint prosthesis with one of TDR model which was fabricated to try multi-axis wear test as a region of motion in ankle joint. The wear specimen of TDR was prepared with Ti-6Al-4V alloy and UHMWPE (ultra-high molecular weight polyethylene) for tibia-talus and bearing component, respectively. A wear test was carried out using a Force 5 (AMTI, Massachusetts, US) wear simulator which can be allowed to move in three axis to flexion-extension ($+3^{\circ}{\sim}-6^{\circ}$), internal-external axial rotation (${\pm}5^{\circ}$), as well as sinusoidal compressive load (1.6 kN, R=10). All tests were performed following standard ISO 14243, wear rate was calculated with weight loss of UHMWPE bearing while the specimen has tested at certain cycles. As based on the preliminary results, wear rate of UHMWPE bearing was $7.9{\times}10^{-6}mg/cycles$ ($R^2=0.86$), calculated loss weight until $10^7cycles$ was 79 mg, respectively.

  • PDF

Ankle Salvage Procedure without Internal Fixation for Large Bone Defect after Failed Total Ankle Arthroplasty: A Case Report (실패한 족관절 인공관절 치환술 후 큰 골결손에서 내고정 없이 시행한 족관절 구제술: 증례 보고)

  • Park, Man-Jun;Eun, Il-Soo;Jung, Chul-Young;Ko, Young-Chul;Yoo, Chong-Il;Kim, Min-Woo;Hwang, Keum-Min
    • Journal of Korean Foot and Ankle Society
    • /
    • v.18 no.2
    • /
    • pp.76-79
    • /
    • 2014
  • In treatment of failure in ankle joint replacement therapy, talar avascular necrosis with massive bone defect, talus fracture with severe comminution and bone defect and ankle dislocation, treatment of large bone defects is considerably important for ankle joint stability and union, therefore, the choice of treatment for large bone defects is use of femoral head or iliac crest bone graft and rigid internal fixation. Because first generation total ankle arthroplasty performed for the first time using a cemented fixation technique requires a large amount of bone resection during re-surgery and there is some possibility of a larger bone defect after removal of implants, in cases where prosthesis for the defect is needed, performance of palliative femoral head or iliac crest bone graft and rigid internal fixation can be difficult. We report on a case of a 48-year-old woman who had experienced ankle pain for 25 years since undergoing total ankle arthroplasty. Because the patient had little ankle motion and rigid soft tissue despite a large bone defect caused by aseptic loosening, a good outcome was obtained only for the femoral cancellous bone graft using allo femoral head without internal fixation.