• 제목/요약/키워드: torque harmonics

검색결과 140건 처리시간 0.023초

퍼지 가변스위칭 섹터기법를 이용한 유도전동기의 직접토크 제어 (Direct Torque Control for Induction Motors Using Fuzzy Variable Switching Sector)

  • 윤인식;서영민;류지수;이기상;홍순찬
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.233-233
    • /
    • 2000
  • Direct torque control (DTC) scheme provides a very quick torque response without the complex field-orientation block and inner current regulation loop. DTC is known as an appropriate scheme for high power induction motet drives because it can be used at lower switching frequency. There are two major drawbacks with the application of DTC schemes : one is large current harmonics due to flux drooping in a low speed range, the other is that the inverter switching frequency is varying according to motor parameters and operating speed. Switching devices in the power electronics drives should be supported for relatively high switching frequency. In this paper, a P-type fuzzy controller to realize the variable switching sector scheme and a PID-type fuzzy switching frequency regulator are adopted. A meaningful contribution of this paper is to propose a simple realization scheme of the fuzzy switching frequency regulator. Simulation results show the effectiveness of those propositions.

  • PDF

전기추진선박의 토크 및 속도변화에 따른 전력변환장치의 고조파 분석 (Harmonic Analysis of Power Conversion System for Torque and Speed Changing of Electric Propulsion Ship)

  • 김종수;김성환
    • 해양환경안전학회지
    • /
    • 제17권1호
    • /
    • pp.83-88
    • /
    • 2011
  • 근래에 전기추진선박의 필요성이 대두되고 있으며 특수선박을 시작으로 건조가 증가되고 있는 실정이다. 하지만 선박은 운항 환경에 따라 추진기의 출력 토크 및 속도의 변동이 심하므로 전기추진시스템에 큰 영향을 미친다. 대표적으로 출 입항시, 정상상태의 대양 항해시, 황천 항해시에 선박 추진시스템의 토크 및 속도 변동이 짧지만 빈번하게 변동하게 되므로 전기추진시스템의 전력변환장치에서 전류 및 전압파형에 고조파가 크게 포함되어 발전기, 변압기, 컨버터, 인버터 및 추진전동기에 손실의 증가, 기기의 열화 및 토크 맥동 발생 등의 좋지 않은 영향을 미치게 된다. 본 연구에서는 선박의 운항 환경에 따른 추진시스템의 전류 및 전압파형에 포함되는 고조파 함유율을 분석하였다. 분석 결과 저속 영역에서의 잦은 속도 및 부하 변동에 따라서 전동기에 공급되는 전류 및 전압 파형에 포함된 총 고조파 왜형율과 전동기의 토크 맥동이 증가됨을 확인할 수 있었다.

하이브리드형 스텝모터의 모델링 및 디텐트 토크 고조파 분석 (Modeling and Detent Torque Hormonic Analysis of Hybrid Type Step Motor)

  • 윤신용;백수현;김용;김철진
    • 조명전기설비학회논문지
    • /
    • 제16권5호
    • /
    • pp.14-21
    • /
    • 2002
  • 본 논문은 4상과5상 하이브리드형 스텝모터의 모델링, 특성해석 및 디텐트 토크에 대한 고조파 저감을 대상으로 연구하였다. 이를 위하여 기계적인 모델링을 도출하였으며 자계해석을 위해서 퍼미언스법을 이용하였다. 이러한 해석 결과 본 모델에 대한 디텐트 토크를 얻을 수 있었다. 또한 두 모델 구조에 대한 상차의 특성해석 비교를 통하여, 본 모델에 대한 디텐트 토크를 유도해 낼 수 있었다. 이때 5상 스텝모터는 4상 스텝모터에 비하여 디텐트 토크의 감소와 스텝응답이 개선됨을 알 수 있었다. 해석결과 퍼미언스분포의 크기는 평균토크의 발생에 영향을 미치며, 고조파성분의 크기가 토크 리플의 크기를 발생함을 알 수 있었다.

5상 유도전동기의 속도응답특성 개선을 위한 직접토크제어 시스템 (A Direct Torque Control System for Improving Speed Response of Five-Phase Induction Motor)

  • 김민회;최성운
    • 조명전기설비학회논문지
    • /
    • 제26권1호
    • /
    • pp.66-74
    • /
    • 2012
  • This paper propose a improved direct torque control(DTC) system for improving operation of five-phase squirrel-cage induction motor(IM). A five-phase IM drives present unique characteristics due to the additional degrees of freedom and also drives possess many others advantage compared with the traditional three-phase motor drive system, such as reducing a amplitude of torque pulsation and increasing the reliability. In order to maximize the torque per ampere, the proposed motor has concentrated windings and the produced back-electromotive force(EMF) is almost trapezoidal, and the motor is supplied with the combined sinusoidal plus third harmonic of currents, there is necessary to controlled 3rd harmonic current. Also a DTC method is advantageous when it is applied to the five-phase IM, because the five-phase inverter provides 32 space vectors in comparison to 8 space voltage vectors into the three-phase inverter drive system. For presenting the superior performance of the proposed DTC, experimental results of speed control are presented using a 32-bit fixed point TMS320F2812 DSP with 1.5[hp] IM.

Selection of Voltage Vectors in Three-Level Five-Phase Direct Torque Control for Performance Improvement

  • Tatte, Yogesh N.;Aware, Mohan V.
    • Journal of Power Electronics
    • /
    • 제16권6호
    • /
    • pp.2162-2172
    • /
    • 2016
  • This paper presents a Direct Torque Control (DTC) strategy for the five-phase induction motor driven by a three-level five-phase inverter in order to improve the performance of the five-phase induction motor. In the proposed DTC technique, only 22 voltage vectors out of 243 available voltage vectors in a three-level five-phase inverter are selected and are divided in 10 sectors each with a width of $36^{\circ}$. The four different DTC combinations (DTC-I, II, III and IV) for a three-level five-phase induction motor drive are investigated for improving the performance of five-phase induction motor. All four of the DTC strategies utilize a combination of the same large and zero voltage vectors, but with different medium voltage vectors. Out of these four techniques, DTC-II gives the best performance when compared to the others. This DTC-II technique is analyzed in detail for improvements in the performance of five-phase induction motor in terms of torque ripple, x-y stator flux and Total Harmonics Distortion (THD) of the stator phase current when compared to its two-level counterparts. To verify the effectiveness of the proposed three-level five-phase DTC control strategy, a DSP based experimental system is build. Simulation and experimental results are provided in order to validate the proposed DTC technique.

역률개선과 고효율을 위한 스위치드 릴럭터스 전동기의 구동 시스템 (Energy-efficient C-dump Converter for SRM Drives with Power Factor correction)

  • 윤용호;이태원;송상훈;김연충;원충연
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2004년도 전력전자학술대회 논문집(1)
    • /
    • pp.214-218
    • /
    • 2004
  • Switched Reluctance Motor (SRM) offers the advantages of simple and robust motor construction, high speeds and high efficiencies over a wide operating range of torque and speed, excellent controllability. However, SRM has the disadvantages of high current harmonics, and low power factor because of a capacitor filter is inserted in the power converter and inductance of SRM is high, it has pulse waveform of current. This paper deals with an energy efficient converter fed SRM system with the reduced harmonics and improved power factor and with higher efficiency. The validity of the proposed scheme is verified via experiment. We are implemented the proposed control system using 80C196KC micro-controller.

  • PDF

스위치드 릴럭턴스 전동기를 위한 구동시스템의 역률개선과 고효율에 관한 연구 (The Study for Power Factor Correction and High Efficiency of Switched Reluctance Motor Drive System)

  • 한대희;최준혁;윤용호;정동효;김도균;원충연
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 전력전자학술대회 논문집
    • /
    • pp.11-15
    • /
    • 2002
  • Switched Reluctance Motor (SRM) offers the advantages of simple and robust motor construction, high speeds and high efficiencies over a wide operating range of torque and speed, excellent controllability. However, SRM has the disadvantages of high current harmonics, and low power factor because of a capacitor filter is inserted in the power converter and inductance of SRM is high, it has pulse waveform of current. This paper deals with an energy efficient converter fed SRM system with the reduced harmonics and improved power factor and with higher efficiency. The validity of the proposed scheme is verified via experiment. We are implemented the proposed control system using 80C196KC micro-controller.

  • PDF

고주파자속을 고려한 단순상유도전동기의 해석 (Analysis of Single-phase Induction Motor Having Space Harmonics in Its Magnetic Field)

  • 오긍렬
    • 전기의세계
    • /
    • 제22권3호
    • /
    • pp.25-34
    • /
    • 1973
  • In this paper, the characteristics of a single phase induction motor which is considered the space harmonic flux by the double revolving field theory is analysed. As the rotor resistance for the fundamental flux is separated from the resistance for the rotor bar and end-ring, and the rotor leakage reactnace is separated from the skew leakage reactance and the other, so the circuit constants for the space harmonic flux is expressed by the circuit constants for the fundamentals. As the ratio of the circuit constants for the magnetizing reactance is used, the generalized equivalent circuit is made up. the characteristic equation which is able to analysis the subdivided characteristics by the above circuit is induced. The ratio of the circuit constants and the skew angle being changed, the variations of the torque-speed characteristics for the fundamentals and harmonics is examined by this equation.

  • PDF

저압 시스템에서 비선형 부하의 사용에 따른 고조파 전류 해석 (Analysis of harmonics current using non-linear load at low voltage system)

  • 김종겸;이은웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.13-16
    • /
    • 2001
  • This paper describes the problems associated with the use of PWM ASDs to drive induction motors. A major effect of harmonic voltages and currents in induction motors is increased heating due to iron and copper losses at harmonic frequencies. The harmonic components thus affect the motor efficiency, and can also affect the torque developed. In order to investigate the effect of harmonics which is caused by using of nonlinear load at the low voltage system, we fixed up simple load model and measured the voltage and current. Measurement. results show that additional operation of linear load at the parallel bus in using nonlinear load such as ASD is helpful to the reduction of harmonic current.

  • PDF

Comparative Study of Field-Oriented Control in Different Coordinate Systems for DTP-PMSM

  • Zhang, Ping;Zhang, Wei;Shen, Xiaofeng
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제2권3호
    • /
    • pp.330-335
    • /
    • 2013
  • This paper performs two kinds of Field-Oriented Control (FOC) for dual three phase permanent magnet synchronous motor (DTP-PMSM).The first is based on vector space decomposition to study the effect of current harmonics on electromechanical energy conversion. And the second presents the coupling relations between two sets of windings using two d-q transformation. And then this paper has deeply studied the differences between these two strategies, the different effect on the control of harmonic current and the reason for these differences. MATLAB-based Simulation studies of a 3KW DTP-PMSM are carried out to verify the analysis of differences between the two FOC strategies.