• 제목/요약/키워드: top-flange beam splice connection

검색결과 2건 처리시간 0.014초

Ductile capacity study of buckling-restrained braced steel frame with rotational connections

  • Mingming Jia;Jinzhou He;Dagang Lu
    • Steel and Composite Structures
    • /
    • 제46권3호
    • /
    • pp.417-433
    • /
    • 2023
  • The maximum ductility and cumulative ductility of connection joints of Buckling-Restrained Braced Frames (BRBF) are critical to the structural overall performance, which should be matched with the BRB ductility. The two-story and one-span BRBF with a one-third scale was tested under cyclic quasi-static loading, and the top-flange beam splice (TFBS) rotational connections were proposed and adopted in BRBF. The deformation capacity of TFBS connections was observed during the test, and the relationship between structural global ductility and local connection ductility was studied. The rotational capacity of the beam-column connections and the stability performance of the BRBs are highly relevant to the structural overall performance. The hysteretic curves of BRBF are stable and full under large displacement demand imposed up to 2% story drift, and energy is dissipated as the large plastic deformation developed in the structural components. The BRBs acted as fuses and yielded first, and the cumulative plastic ductility (CPD) of BRBs is 972.6 of the second floor and 439.7 of the first floor, indicating the excellent energy dissipation capacity of BRBs. Structural members with good local ductility ensure the large global ductility of BRBF. The ductile capacity and hysteretic behavior of BRBF with TFBS connections were compared with those of BRBF with Reduced Beam Section (RBS) connections in terms of the experimental results.

콘크리트채움 U형합성보-H형강기둥 십자형 합성접합부의 내진성능 (Cyclic Seismic Testing of Cruciform Concrete-Filled U-Shape Steel Beam-to-H Column Composite Connections)

  • 박창희;이철호;박홍근;황현종;이창남;김형섭;김성배
    • 한국강구조학회 논문집
    • /
    • 제23권4호
    • /
    • pp.503-514
    • /
    • 2011
  • 본 연구에서는 콘크리트채움 U형 합성보와 H형강 기둥 십자형 합성접합부의 내진상세를 제시하고, 2개의 실물대 실험체를 설계/제작하여 강구조내진기준의 표준실험절차에 따라 내진성능을 평가하였다. 주요 실험체 구성요소는 춤 450mm(실험체 A) 및 550mm(실험체 B) U형 강재보, 두께 165mm의 골데크플레이트 위에 타설된 콘크리트 바닥슬래브, U형보의 완전합성작용을 하기 위한 전단스터드, 부모멘트 전달을 위한 4개의 주철근 및 H형강 기둥에 정착을 위한 용접커플러 그리고 접합부 보강을 위한 보강판으로 구성된다. 순수 강재 보-기둥 접합부와 상이한 U형 합성접합부의 독특한 특성을 고려하여, 지진하중 하에서 내진성능에 결정적 영향을 미치는 보-기둥 접합부의 용접부 취성파단, 강판의 국부좌굴, 주철근의 휨좌굴, 콘크리트 압괴 등의 한계상태가 적절히 제어되도록 실험체를 설계하였다. 강구조내진기준의 지진하중 가력프로그램에 따른 실험결과, 설계에서 의도한 바와 같이 여러 한계상태가 적절히 제어되어 실험체 A 및 B는 각각 6% 및 6.8% 라디안에 이르는 매우 뛰어난 층간변형능력을 발휘하였다. 이는 특수모멘트골조에 요구되는 4% 라디안 수준을 충분히 상회하는 만족스런 층간변형능력이다. 특히 접합부 강화전략에 의해 제안된 합성접합부 상세는 설계에서 의도한 것과 같이 소성힌지를 보강단부로서 밀어냄으로서 취약할 수 있는 보-기둥 용접접합부를 효과적으로 보호하였다. 실험체 A의 최종 파괴모드는 6.0% 층간변위에서 발생한 보강단부에 인접한 냉간성형 코너부의 점진적 저사이클피로에 의한 하부플랜지의 파단에 의해 발생하였다. 한편, 실험체 B는 8.0%의 높은 수준의 층간변위에서 발생한 볼트이음부 파단에 의해 내력을 상실하였다.