• Title/Summary/Keyword: tooth enamel

Search Result 436, Processing Time 0.023 seconds

A STUDY ON THE ARTIFICIAL INTERPROXIMAL CARIES DETECTION WITH THE DIGITAL RADIOGRAPHY (디지털방사선촬영술을 이용한 인접면 치아우식증 진단에 관한 실험적 연구)

  • Kwon Ki Jeong;Hwang Eui-Hwan;Lee Sang Rae
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.24 no.1
    • /
    • pp.85-94
    • /
    • 1994
  • The purposes of this study were clinical comparison and evaluation between digital radiography and conventional radiography for the detection of artificial interproximal caries. Four freshly extracted, unrestored posterior teeth were obtained and caries was simulated by drilling semicircled defects with variable size at the interproximal surface of each tooth. The experiments were performed with IBM-PC/32 bit-DX compatible, video camera(VM-S8200, Hitachi Co., Japan), and color monitor(Multisync 3D, NEC, Japan). Sylvia Image Capture Board for the ADC(analog to digital converter) was used, and spatial resolution was 512 × 480 with 256 gray levels. The obtained results were as follows: 1. At the condition of under exposure, the radiographs were superior to the digital images in readability. Also, as the size of the artificial lesion was increased, readability of the radiographs was elevated. 2. The digital images were superior to the radiographs in readability especially under over exsposure. 3. As the exposure time and size of lesion was increased, the gray level of region of interest of the digital image was decreased proportionally. 4. As the F-value of average gray level of region of interest at individual exposure time and size of lesion, gray level of the all lesion sizes was decreased in comparison with that of the normal enamel.

  • PDF

Effect of titanium and stainless steel posts in detection of vertical root fractures using NewTom VG cone beam computed tomography system

  • Mohammadpour, Mahdis;Bakhshalian, Neema;Shahab, Shahriar;Sadeghi, Shaya;Ataee, Mona;Sarikhani, Soodeh
    • Imaging Science in Dentistry
    • /
    • v.44 no.2
    • /
    • pp.89-94
    • /
    • 2014
  • Purpose: Vertical root fracture (VRF) is a common complication in endodontically treated teeth. Considering the poor prognosis of VRF, a reliable and valid detection method is necessary. Cone beam computed tomography (CBCT) has been reported to be a reliable tool for the detection of VRF; however, the presence of metallic intracanal posts can decrease the diagnostic values of CBCT systems. This study evaluated and compared the effects of intracanal stainless steel or titanium posts on the sensitivity, specificity, and accuracy of VRF detection using a NewTom VG CBCT system. Materials and Methods: Eighty extracted single-rooted teeth were selected and sectioned at the cemento-enamel junction. The roots were divided into two groups of 40. Root fracture was induced in the test group by using an Instron machine, while the control group was kept intact. Roots were randomly embedded in acrylic blocks and radiographed with the NewTom VG, both with titanium and stainless steel posts and also without posts. Sensitivity, specificity, and accuracy values were calculated as compared to the gold standard. Results: The sensitivity, specificity, and accuracy of VRF diagnosis were significantly lower in teeth with stainless steel and titanium posts than in those without posts. Interobserver agreement was the highest in teeth without posts, followed by stainless steel posts, and then titanium posts. Conclusion: Intracanal posts significantly decreased the VRF diagnostic values of CBCT. The stainless steel posts decreased the diagnostic values more than the titanium posts.

A STUDY ON THE RADIOPACITY OF ESTHETIC DENTAL MATERIALS USING IN THE PEDIATRIC DENTISTRY (소아용 심미수복재의 방사선 불투과성에 관한 연구)

  • Jeong, Tae-Sung;Kim, Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.1
    • /
    • pp.82-86
    • /
    • 2001
  • The aim of this study was to investigate the level of radiopacity of esthetic dental restorative materials and determine the optimum level of radiopacity in pediatric dentistry. Disks of 8 dental restorative material groups as the experimental group, 7mm in diameter and 2mm thick, were radiographed with intact human deciduous teeth and aluminum stepwedge standard. Radiopacity was evaluated with an image analysis program following the digitization of the radiographs using a flatbed scanner with transparency unit. All materials and tooth structure also the significant difference except FP, VB, VM. For the radiopacity of esthetic restorative dental materials to exceed that of enamel, it should be greater than 1.7mm of equivalent thickness of aluminum.

  • PDF

Biological Applications of White Light Scanning Interferometry (백색광 주사간섭계의 생물학적 응용)

  • Kim, Ki-Woo
    • Applied Microscopy
    • /
    • v.41 no.4
    • /
    • pp.223-228
    • /
    • 2011
  • White light scanning interferometry has been employed to analyze surface features of diverse specimens. Long established in the field of materials engineering, the technique provides quantitative three-dimensional data as well as qualitative morphological images. It uses white light that is split and reflected from a reference mirror and an object. Merged together, the light generates interference patterns representing topographical contours of the object surface. The amplitude of the z-axis data is differentiated by gray scale. The technique allows the rapid, noncontact, and wide-field measurements for morphometry of biological specimens including chondrocytes, tooth enamel, and plant leaves. Quantification of the dimension of surface structures such as width, length, and elevation angle could be achievable by white light scanning interferometry. The light reflection from plant leaves has been assumed to be sufficient for the technique. Without special specimen preparations like conductive metal coating, the technique can be increasingly used for quantitative three-dimensional surface measurements of biological specimens.

MICROLEAKAGE AND MARGINAL ADAPTATION OF POSTERIOR COMPOSITE RESIN RESTORATIONS ACCORDING TO RESTORATIVE TECHNIQUE (수복에 따른 구치부 복합레진 수복물의 변연부 미세누출 및 적합도)

  • Yang, In-Seo;Shin, Dong-Hoo
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.1
    • /
    • pp.334-346
    • /
    • 1997
  • Incidence of using esthetic composite resin in the posterior area is increasing but there were lots of inconsistent reports about their microleakage and marginal adaptation. The purpose of this study was to evaluate the differences of microleakage and marginal adaptation according to restorative techniques. 30 cavities with enamel gingival margin were prepared and restored with 3 types of composite resin [Z-100($Scotchbond^{TM}$ MP), AELITEFIL ($Onestep^{TM}$), Her culite XRV(Fuji BOND LC)] in direct technique and another 30 cavities were restored with preformed CR inlays and 3 different modern resin and resin-modified GI cements (Superbond C&B, Choice, Fuji Duet). Samples were chemically stressed in 75% ethanol for 24 hours and were thermocycled (5-$55^{\circ}C$(500 times. The degree of microleakage through proximal and gingival margins was examined by 1 % MB dye and the degree of marginal adaptation by examining the margins via SEM. The following results were obtained ; 1. In direct groups, Herculite XRV [Fuji BOND LC, 35.13 (15.50) %] group showed statistically different, less microleakage than Z-100 [$Scotchbond^{TM}$ MP, 72.91 (16.91 %] group and AELITEFIL [One-step, 93.73 (13.66) %] group (p<0.05). 2. In indirect groups, the degree of microleakage in Mean(S.D.) were: Super bond C & B [39.00 (24.35) %], Choice [57.19 (33.80) %], Fuji Duet [58.22 (40.36) %]. But there was no significant difference. 3. There was no significant difference between resin cement and resin-modified GI cement. 4. There were gaps at the interface with the tooth structure, but no gap was seen at the interface with restoration in all specimens. 5. In direct groups, Herculite XRV(Fuji BOND LC) group made little gap compared with other groups, but 40-$50{\mu}m$ thickness of bonding agent, Fuji BOND LC, looked like a cement used in indirect technique. 6. All indirect groups showed a variety of cement thickness, from less than $20{\mu}m$ to over $100{\mu}m$ and that dimension of buccal/lingual margin was less than that of gingival margin.

  • PDF

Enamel pretreatment with Er:YAG laser: effects on the microleakage of fissure sealant in fluorosed teeth

  • Memarpour, Mahtab;Kianimanesh, Nasrin;Shayeghi, Bahareh
    • Restorative Dentistry and Endodontics
    • /
    • v.39 no.3
    • /
    • pp.180-186
    • /
    • 2014
  • Objectives: The purpose of this in vitro study was to evaluate the microleakage and penetration of fissure sealant in permanent molar teeth with fluorosis after pretreatment of the occlusal surface. Materials and Methods: A total of 120 third molars with mild dental fluorosis were randomly divided into 6 groups (n = 20). The tooth surfaces were sealed with an unfilled resin fissure sealant (FS) material. The experimental groups included: 1) phosphoric acid etching (AE) + FS (control); 2) AE + One-Step Plus (OS, Bisco) + FS; 3) bur + AE + FS; 4) bur + AE + OS + FS; 5) Er:YAG laser + AE + FS; and 6) Er:YAG laser + AE + OS + FS. After thermocycling, the teeth were immersed in 0.5% fuchsin and sectioned. Proportions of mircoleakage (PM) and unfilled area (PUA) were measured by digital microscope. Results: Overall, there were significant differences among all groups in the PM (p = 0.00). Group 3 showed the greatest PM, and was significantly different from groups 2 to 6 (p < 0.05). Group 6 showed the lowest PM. Pretreatment with Er:YAG with or without adhesive led to less PM than bur pretreatment. There were no significant differences among groups in PUA. Conclusions: Conventional acid etching provided a similar degree of occlusal seal in teeth with fluorosis compared to those pretreated with a bur or Er:YAG laser. Pretreatment of pits and fissures with Er:YAG in teeth with fluorosis may be an alternative method before fissure sealant application.

MARGINAL ADAPTATION OF COMPOSITE RESIN USING GLASS IONOMER CEMENT BASES (Glass ionomer cement를 이장한 Composite resin의 변연 적합성에 관한 연구)

  • Han, Seung-Weon
    • Restorative Dentistry and Endodontics
    • /
    • v.14 no.2
    • /
    • pp.5-19
    • /
    • 1989
  • The purpose of this study was to observe the microleakage of composite resin filling using several glass ionomer cements. The Class V cavities of eighty noncarious human molars were prepared at the cementoenamel juction on the facial and lingual surfaces of each tooth with a No.330 carbide bur in a high speed handpiece. The cavity dimensions were $3.0{\pm}0.5mm$ wide, $2.0{\pm}0.5mm$ high, and $1.5{\pm}0.5mm$ deep and all enamel cavosurface margins were beveled with a No.558 carbide bur in low speed handpiece. The bevel was approximately $45^{\circ}$ and 0.5-1.0mm in width. A total of the 160 cavities was divided into four groups, and then 144 cavities among them were three experimental groups and remaining sixteen cavities were control group. All of the prepared cavities were restored as follows: group 1 : Preparations were restored with there three glass ionomer cements. group 2 : Preparations were restored with a composite resin with three glass ionomer cement bases placed $0.2{\pm}0.1mm$ short of the cavosurface margin. group 3 : Preparations were restored with a composite resin with three glass ionomer cement bases extened to the cavosurface margin. group 4 : As control group, preparations were restored with a composite resin, PALFIQUE. The specimens were then thermocycled in a range of $6^{\circ}C-60^{\circ}C$ and immersed in a bath of 2.0% aqueous basic fuchsin solution for 24 hours. Dye penetration was read on a scale of 0 to 4 by Tani and Buonocore's method. The following conclusions were derived from the results obtained; 1. All groups showed significantly more leakage at the gingival margins than at the occlusal margins(p<0.0005). 2. At the gingival margins, group 1 showed less leakage than group 3(p<0.01) and group 4(p<0.0005), while group 3 exhibited less leakage than group 2(p<0.01) and group 4(p<0.0005). 3. At the occlusal margins, group 4 showed less leakage than group 3(p<0.1) and group 1(p<0.005), while group 3 exhibited less leakage than group 2(p>0.1) and group 1(p<0.025).

  • PDF

Detecting Incipient Caries Using Front-illuminated Infrared Light Scattering Imaging

  • Kim, Ji-Young;Ro, Jung-Hoon;Jeon, Gye-Rok;Kim, Jin-Bom;Ye, Soo-Young
    • Transactions on Electrical and Electronic Materials
    • /
    • v.13 no.6
    • /
    • pp.310-316
    • /
    • 2012
  • A new method for early caries diagnosis was proposed and tested through a home-made optical examination system that used quantitative light fluorescence (QLF) and digital imaging fiber optic transillumination (FOTI) (DIFOTI), with light sources across a wide spectral range, from 350 nm to 1,000 nm. The front-illuminated infrared light scattering image (FIR) showed similar diagnostic abilities to that of DIFOTI. The FIR method was invented based on the observation that caries lesions lose the high transmittance and low scattering properties of benign enamel tissue. There are various methods for the early diagnosis of caries, such as visual examination, exploration, X-ray radiography, QLF, FOTI, and infrared fluorescence (diagnodent). Among them, methods based on optical properties are regarded as having the most potential. A comparative study was performed between the FOTI, QLF, diagnodent, optical coherence tomography, and FIR scattering image methods, using 20 extracted teeth samples with early caries. A scale of lesion measurement based on optical image contrast was proposed. The statistical analysis showed a significant correlation between the DIFOTI and FIR methods (r = 0.35, p < 0.05). However, the QLF and diagnodent methods showed little association with FIR images, as they have different detection principles as compared with FIR. Tomographic images obtained by OCT, using 1,330 nm super luminescent LED as a gold standard of tooth structure, verified that the FOTI and FIR results correctly represented the lack of homogeneity in dental tissue. The newly proposed FIR method attained similar diagnostic results to those of FOTI, but with an easier approach.

THE EFFECT OF CAVITY CONFIGURATION ON MARGINAL LEAKAGE OF CLASS 5 RESTORATION (와동형태가 5급 와동 수복물의 변연누출에 미치는 영향)

  • Park, Jeong-Kil;Hur, Bock;Lee, Hee-Ju
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.2
    • /
    • pp.162-170
    • /
    • 2001
  • The purpose of this study was to investigate the effect of cavity configurations on the marginal leakage of class 5 glass ionomer cement and composite resin restorations. Four types of cavities such as saucer shape. notch shape. combined shape(notch shape occlusally and saucer shape gingivally). and U shape were prepared on the buccal and lingual surfaces of 80 extracted premolars(40 cavities for each shape). Occlusal cavity margins were placed at enamel and cervical margins were placed at dentin. 10 cavities of each shape were restored with Ketac Fil as a conventional glass ionomer cement. Fuji II LC improved as a resin modified glass ionomer cement, Z 100 as a hybrid composite resin. and Tetric Flow as a flowable composite resin (40 cavities for each material). After thermocycling, teeth were immersed in 5% basic fuchsin solution for 6 hours and sectioned longitudinally in a buccolingual direction through the center of the restoration. The dye penetrations at the tooth restoration interface were examined by stereomicroscope. The Result were as follows 1. In saucer shape, notch shape and combined shape, composite resin restorations showed lesser leakage than glass ionomer restorations(p<0.05) and in U shape. Tetric Flow showed the least marginal leakage and others were decreased as Z 100. Fuji II LC improved, Ketac Fil in that order. There were statistically significant difference between Tetric Flow and Fuji II LC improved. Ketac Fil and between Z 100 and Ketac Fil(p<0.05). 2. In Ketac Fil restoration group, saucer shape showed the highest marginal leakage and U shape showed the least marginal leakage and others were decreased as notch shape, combined shape in that order. There were statistically significant difference between saucer shape and combined shape, U shape and between notch shape and U shape(p<0.05). 3. In Fuji II LC improved restoration group, U shape showed the least marginal leakage. There were statistically significant difference between U shape and other three shapes(p<0.05). 4. The cavity configuration had no significant effect on marginal leakage of composite resin restorations(p>0.05).

  • PDF

INFLUENCE OF ARTIFICIAL SALIVA CONTAMINATION ON BONDING OF DENTIN ADHESIVES TO DENTIN (인공타액 오염이 수종 상아질접착제와 상아질간의 결합에 미치는 영향)

  • Ryu, Mee-Ae;Yang, Kyu-Ho;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.17 no.2
    • /
    • pp.383-397
    • /
    • 1992
  • The purpose of this study was to evaluate the influence of artificial saliva contamination on bonding of several dentin adhesives to dentin. Sixty - three human molar teeth extracted within a month were used. Each tooth was sectioned longitudinally in a buccolingual direction to obtain 126 specimens. These specimens were randomly divided into three groups and were treated by Scotchbond 2, Gluma and All bond. Each group was subdivided into three subgroups; normal group not contaminated with artificial saliva, contaminated with artificial saliva and dried group, and contaminated with artificial saliva and washed and dried group. Enamel/dentin bonding agent(Dental Adhesive of Scotchbond 2) was applied and light cured on the treated dentin surfaces. Thereafter P - 50 were cured on them, and specimens were stored in $37^{\circ}C$ artificial saliva for 24 hours before measuring shear bond strength. Shear bond strengths were determined using an universal testing machine with cross head speed 1mm/min and SEM examinations were conducted to evaluate the resin - dentin interface and degree of penetrating resin string into the dentinal tubules. The following results were obtained. 1. Normal groups not contaminated with artificial saliva showed greater shear bond strength than any other group contaminated with artificial saliva(P<0.01). 2. The shear bond strengths showed no significant difference between washed groups with distilled water and not washed groups after contamination with artificial saliva(P>0.05). 3. In normal groups, the shear bond strength of A group was significantly greater than in any other group(P<0.01). 4. In Sand G groups, fractures after shear bond strength tests occured adhesively on resintooth interface in all specimens. But in A groups, fracture of the normal group occured cohesively in dentin and fracture of the contaminated groups occured adhesively and cohesively. 5. On SEM examination, the number of resin strings penetrated into dentinal tubules were the greatest in normal groups, followed by, in descending order, washed groups and not washed groups after contamination with artificial saliva.

  • PDF