• Title/Summary/Keyword: tooth dry

Search Result 77, Processing Time 0.024 seconds

The effect of mandibular position and gantry angle on the evaluation of implant site with implant CT (임플랜트 전산화단층사진에서 하악의 위치와 gantry각의 변화가 임플랜트 매식로 평가에 미치는 영향에 관한 연구)

  • Lee Sul-Mi;An Chang-Hyeon;Choi Hang-Moon;Heo Min-Suk;Lee Sam-Sun;Choi Soon-Chul;Park Tae-Won
    • Imaging Science in Dentistry
    • /
    • v.32 no.1
    • /
    • pp.35-39
    • /
    • 2002
  • Purpose: The altered gantry angle during scanning for some multiplanar reconstruction CT program (CT/MPR) may cause distortion of the image. The aim of this study was to ascertain whether there is a image distortion in a reformatted image when the gantry and the object are equally inclined using ToothPix and DentaScan program. Materials and Methods: A resin block model with four cylindrical holes and a human dry mandible were used. Two MPR software packages, ToothPix and DentaScan program, were used for reformatted panoramic images. The block and the gantry were equally inclined at 0°, 15°, and 30°. Results: With ToothPix program, a resin block model with empty holes and a dry mandible showed inclined images in the reformatted panoramic image. Increasing the gantry angle, the depth and inclination of the holes were increased in the reformatted central panoramic images. However, a resin block model with gutta perch a in its holes and a dry mandible with a wire in its mandibular canal didn't show image distortion. With DentaScan program, image distortion was not seen in any situation. Conclusion: ToothPix program may distort the reformatted image when the gantry angle is not at zero degrees. However, with DentaScan program, the patient may be positioned comfortably and the gantry can be adjusted to the patient positioning.

  • PDF

자가 치아 이식술에 사용되는 Computer Aided Rapid Prototyping model(CARP model)의 실제 치아에 대한 오차

  • Lee, Seong-Jae;Kim, Ui-Seong;Kim, Gi-Deok;Lee, Seung-Jong
    • The Journal of the Korean dental association
    • /
    • v.44 no.2 s.441
    • /
    • pp.115-122
    • /
    • 2006
  • Objective : The purpose of this study was to evaluate the dimensional errors between real tooth, 3D CT image and CARP model. Materials and Methods : Two maxilla and two mandible block bones with intact teeth were taken from two cadavers. Computed tomography was taken either in dry state and in wet state. After then, all teeth were extracted and the dimensions of the real teeth were measured using a digital caliper at mesio-distal and bucco-lingual width both in crown and cervical portion. 3D CT image was generated using the V-works $4.0^{TM}$ (Cybemed Inc., Seoul, Korea) software. Twelve teeth were randomly selected for CARP model fabrication. All the measurements of 3D Ct images and CARP models were made in the same manner of the real tooth group. Dimensional errors between real tooth, 3D CT image model and CARP model was calculated. Results : 1) Average of absolute error was 0.199 mm between real teeth and 3D CT image model, 0.169 mm between 3D CT image model and CARP model and 0.291 mm between real teeth and CARP model, respectively. 2) Average size of 3D CT image was smaller than real teeth by 0.149 mm and that of CARP model was smalier than 3D CT image model by 0.067mm. Conclusion : Within the scope of this study, CARP model with the 0.291 mm average of absolute eror can aid to enhance the success rate cf autogenous tooth transplantation due to the increased accuracy of recipient bone and donor tooth.

  • PDF

In-vitro assessment of the accuracy and reliability of mandibular dental model superimposition based on voxel-based cone-beam computed tomography registration

  • Han, Gaofeng;Li, Jing;Wang, Shuo;Liu, Yan;Wang, Xuedong;Zhou, Yanheng
    • The korean journal of orthodontics
    • /
    • v.49 no.2
    • /
    • pp.97-105
    • /
    • 2019
  • Objective: This study was performed to evaluate the accuracy and reliability of a newly designed method to achieve mandibular dental model superimposition, using voxel-based cone-beam computed tomography (CBCT) registration. Methods: Fourteen dry cadaveric mandibles and six teeth extracted from patients with severe periodontitis were used to establish 14 orthodontic tooth-movement models. The protocol consisted of two steps: in the first step, voxel-based CBCT mandible superimposition was performed; the reference comprised the external portion of the symphysis, extending to the first molar. The laser-scanned dental model image was then integrated with the CBCT image to achieve mandibular dental model superimposition. The entire process required approximately 10 minutes. Six landmarks were assigned to the teeth to measure tooth displacement, using tooth displacement on the superimposed laser-scanned mandibles as the reference standard. Accuracy was evaluated by comparing differences in tooth displacement based on the method and the reference standard. Two observers performed superimposition to evaluate reliability. Results: For three-dimensional tooth displacements, the differences between the method and the reference standard were not significant in the molar, premolar, or incisor groups (p > 0.05). The intraclass correlation coefficients for the inter- and intra-observer reliabilities of all measurements were > 0.92. Conclusions: Our method of mandibular dental model superimposition based on voxel registration is accurate, reliable, and can be performed within a reasonable period of time in vitro, demonstrating a potential for use in orthodontic patients.

THE STUDY OF APICAL CHANGES ON THE ORTHOPANTOMOGRAPH (Orthopantomograph에 있어서 치근부 상의 변화에 관한 연구)

  • Ahn Hyung Kyu
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.9 no.1
    • /
    • pp.19-23
    • /
    • 1979
  • A study was made primarily to investigate vertical and horizontal distortion of the image at the apical region of the dental roots in orthopantomographs. The subjects consisted of two dry skulls with radiopaque materials attached to root surface. Measuring of the width and length of each predetermined point at 23 teeth was performed in dry skulls and radiographic films. The results obtained were as follows; 1. There was overall magnification of image in the vertical dimension. And anterior portion had greater magnification rate than posterior portion, while lower anterior portion had less magnification rate than upper anterior portion. 2. There was reduction of the image in the horizontal dimension of the teeth, because of the position relation between dry skull and image layer of the orthopantomograph. 3. There was a significant difference in distortion rate between the oposite teeth. 4. Cervical portion of the tooth had more decreased rate of horizontal distortion than apical portion.

  • PDF

TREATMENT OF COMPOSITE RESIN RESTORATION WITH THE AIR ABRASIVE TECHNIQUE (Air abrasive technique을 이용한 복합레진 수복 증례)

  • Lee, Chang-Woo;Jang, Ki-Taeg;Lee, Sang-Hoon;Hahn, Se-Hyun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.24 no.4
    • /
    • pp.763-770
    • /
    • 1997
  • The air abrasive technique is a non-mechanical method by which teeth are treated before restoration and stains and calculi are removed from tooth surfaces using the kinetic energy of small particles. The air abrasive technique in dentistry was first introduced in the 1950's with as instrument called 'Airdent'. But, as the main restorative materials of the period were amalgam and gold, and the instrument's inability to control the flow of particles caused the particles to be spread throughout the clinics, widespread use was not possible. In the 1990's, as these techincal problems were solved and more interest in new restorative materials rose in an effort to preserve sound tooth structure, new developements took place in instruments related to the air abrasive technique. The air abrasive technique produces less pressure, vibration and heat that might cause patient discomfort and facilitates the preservation of sound tooth structure. It also reduces the need for anesthesia and is less harmful to the pulp. Other advantages include increase in dentin bonding strength of composite resin, lower possibility of saliva contamination and maintenance of a dry field. But there is not direct contact between the nozzle and the tooth, the operator cannot use his or her tactile sense and must rely solely upon visual input. Other disadvantages are: the tooth preparation depends on the operator's ability; alpha-alumina particles, after bouncing off the tooth surface, cause damage to dental mirrors; the equipment is expensive and takes up a certain amount of space in the clinic. The author conducted case report using the air abrasive technique on patient visiting the Department of Pediatric Dentistry at Seoul National University Dental Hospital and arrived at the following conclusions. 1. The tooth preparation capability of different air abrasive devices varied widely among manufacturers. 2. It was more effective in treating early caries lesions and stains compared to lesions where caries had already progressed to produce soft dentin. 3. The cold stream and noise caused by the evacuation system was a major cause of discomfort to pediatric patients. 4. As there is no direct contact with tooth surface when using the air abrasive technique for tooth preparation, considerable experience and skill is required for proper tooth preparation.

  • PDF

A Case Report on Facial Nerve Palsy after Tooth Extraction and Korean Medical Treatments (발치 후 병발한 안면마비 환자에 대한 한의학적 치료 사례 보고)

  • Kim, Dae Hun;Kim, Yu Ri;Bae, Ji Min;Hong, Seung Pyo;Koo, Bon Kil;Kim, Jae Kyu;Lee, Byung Ryul;Yang, Gi Young
    • Journal of Acupuncture Research
    • /
    • v.33 no.2
    • /
    • pp.211-220
    • /
    • 2016
  • Objectives : Facial nerve palsy is a rare but well-known complication that occurs after a tooth extraction. The paralysis follows the injection of a local anesthetic, but patients typically recover after a few hours. However, there are a number of reports of delayed paralysis, and the cause of delayed facial palsy remains uncertain. This study is the first case report detailing how Korean medicine can be used to treat facial nerve palsy following tooth extraction. This study reports our experience of a patient's favorable recovery. Methods : A 25-year-old male patient experienced acute facial palsy after four premolar teeth were extracted. He was hospitalized in the Pusan National University Korean Medical Hospital. We provided complex Korean traditional medical treatments such as acupuncture, cupping, use of a hot water steamer, and herbal medicine for 18 days. Results : Using the Yanagihara Grading Score, we found improvements in the patient's voluntary facial movement as his score increased from 22 to 34. Furthermore, his accompanying symptoms, such as dry eye and facial pain, disappeared. However, the patient reported transient pain around acupoints after the acupuncture intervention. Conclusion : Our study suggests that Korean medical treatments might be effectively used to treat facial nerve palsy after tooth extraction, although further research should be conducted due to the limited number of cases in this area.

EXPERIMENTAL STUDY OF THE CENTER OF RESISTANCE OF A MAXILLARY CANINE USING LASER SPECKLE INTERFEROMETRY AND HOLOGRAPHIC INTERFEROMETRY (상악 견치의 저항 중심에 관한 Laser speckle interferometry와 holographic interferometry볼 이용한 실험적 연구)

  • Lee, Soo Ryong
    • The korean journal of orthodontics
    • /
    • v.18 no.2
    • /
    • pp.289-308
    • /
    • 1988
  • The center of resistance is a important determining factor of tooth movement pattern. Laser speckle interferometry, recently developed for noninvasive measurement of small displacements (microns), was used to detect the center of resistance of a maxillary canine which has normal tooth axis and distal curved root in dry human skull. Laser holographic interferometry was used to verify the results of laser speckle interferometry The following result were obtained; 1. In measurement of the degree of rotation, center of resistance was localized when the traction line passed 4.4/18.0 level from alveola crest to root apex. 2. In measurement of the degree of tipping, center of resistance was localized when the traction line passed 4.6/18.0 level from alveola crest to root apex. 3. In holographic determination, the center of resistance was observed when the traction line passed between 3mm to 6mm level from alveola crest to root apex, therefore the results using laser speckle interferometry was coincided with holographic results.

  • PDF

A RADIOGRAPHIC STUDY ON THE ARTIFICIALLY INDUCED LESIONS INVOLVING LAMINA DURA (실험적 치조백선 병소부에 관한 방사선학적 연구)

  • Kim Young-Jin;Kim Jae-Duk
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.21 no.1
    • /
    • pp.83-89
    • /
    • 1991
  • This study was performed to simulate various sizes of periapical lesions and condensing osteitis in bone and to clarify that condensing osteitis would give a greater radiographic contrast because of the more radiopacity immediately adjacent to the lesion and what the lamina dura on radiogram is in bone. For this study, two dry and wet human adult mandible and a cadaver were used. Each mandible was sectioned longitudinally to split lingual and buccal cortical plates to gain better access to the apex of tooth. Lesions were gradually enlarged and bordered with tooth ash that burned out at 950℃ for the reproduction of condensing osteitis in sequence. The serial radiograms were taken under the constantly maintained condition and compared with the actual lesions.

  • PDF

WATER INDUCED MECHANICAL EFFECT ON THE DENTAL HARD TISSUE BY THE SHORT PULSED LASER

  • Kwon,Yong-Hoon;Kim, You-Young
    • Journal of Photoscience
    • /
    • v.5 no.1
    • /
    • pp.33-37
    • /
    • 1998
  • One macroscopic effect in the free-running Er:YAG laser is an accumulation of microscopic effects. Understanding of the exogenous water induced mechanical effect on the dental hard tissue by the Qswitched Er:YAG laser has an important impact on the further understanding of the free-running Er:YAG laser ablation on the dental hard tissue. The Q-switched Er:YAG laser (1-$\mu$s-long pulse width) was used in the recoil pressure measurement with an aid of water-jet system and a pressure transducer. The amplitude of the recoil pressure depends on the tooth surface conditions (dry and wet) and the volume of the water upon it. Wet surfaces yielded higher recoil pressure than that of dry, surface, and as the volume of the exogenous water drop increased, the amplitude of the recoil pressure increased also.

  • PDF

Wear Characteristics of Plastic Pinion Against Steel Gear (플라스틱기어의 마멸특성에 관한 고찰)

  • 김충현;김영민;안효석;정태형
    • Tribology and Lubricants
    • /
    • v.16 no.5
    • /
    • pp.324-331
    • /
    • 2000
  • Wear characteristics of Plastic and Nylon pinions against steel gear were studied to gain a better understanding of their tribological behaviors. Wear tests were conducted with power circulating gear test rig under dry contact conditions. Specific wear rates were measured as a function of applied load and the number of revolution. The worn teeth surfaces were examined with a profile projector and a camera. Nylon pinion showed lower specific wear rates than acetal pinion, but suffered teeth breakage under high load per unit tooth width. The dominant wear mechanisms found were adhesion and abrasion.