• Title/Summary/Keyword: tomographic images

Search Result 259, Processing Time 0.026 seconds

Imaging Features of Hepatic Adenoma in a Dog with Atypical Computed Tomographic Findings

  • Jin, Hansol;Cheon, Byunggyu;Lee, Gahyun;Park, Seungjo;Lee, Ju-Hwan;Choi, Jihye
    • Journal of Veterinary Clinics
    • /
    • v.35 no.2
    • /
    • pp.53-56
    • /
    • 2018
  • Computed tomography (CT) findings of hepatic adenoma in veterinary medicine are variable and unlike in human medicine, not defined clearly. A 12-year-old neutered male Shih Tzu presented after a seizure, with weight loss, salivation, and cachexia. An abdominal mass was identified on radiography, and ultrasonographic images showed a mixed echo pattern with marked vascularity. CT showed that the mass originated from caudate lobe, was heterogeneously hypoattenuated compared with the hepatic parenchyma, and had irregular margins. Contrast enhanced CT showed that the mass enhanced like the surrounding liver parenchyma. However, it contained unenhanced areas and enhanced vessels were observed in the arterial phase at the periphery of the mass. The margins of mass were more enhanced in the venous phase than the arterial phase and the hypoattenuating regions within the mass were not enhanced. Greater enhancing in the venous phase is seen with adenomas; however, the heterogeneous enhancement pattern, especially the marginal vascular enhancement and internal hypoattenuating regions, is seen with malignancy. Although this is a single case of hepatic adenoma, the atypical enhanced pattern of this case can provide useful information to predict the malignancy of primary liver tumor.

PIV Measurements of Flow and Turbulence Characteristics of Round Jet in Crossflow (횡단류 제트의 유동 및 난류특성치에 대한 PIV 측정)

  • Kim, Kyung-Chun;Kim, Sang-Ki;Yoon, Sang-Youl
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.3
    • /
    • pp.382-389
    • /
    • 2000
  • The instantaneous and ensemble averaged flow characteristics of a round jet issuing normally into a crossflow was studied using a flow visualization technique and Particle Image Velocimetry measurements. Experiments were performed at a jet-to-crossflow velocity ratio, 3.3, and two Reynolds numbers, 1050 and 2100, based on crossflow velocity and jet diameter. Instantaneous laser tomographic images of the vertical center plane of the crossflow jet showed that there exist very different natures in the flow structures of the near field jet even though the velocity ratio is the same. It was found that the shear layer becomes much thicker when the Reynolds number is 2100 due to the strong entrainment of the inviscid fluid by turbulent interaction between the jet and crossflow. The mean and second order statistics were calculated by ensemble averaging over 1000 realizations of instantaneous velocity fields. The detail characteristics of mean flow field, stream wise and vertical r.m.s. velocity fluctuations, and Reynolds shear stress distributions were presented. The new PlV results were compared with those from previous experimental and LES studies.

Efficient crosswell EM tomography for monitoring geological sequestration of $CO_2$

  • Lee, Ki-Ha;Kim, Hee-Joon;Song, Yoon-Ho
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2003.11a
    • /
    • pp.321-327
    • /
    • 2003
  • [ $CO_2$ ] sequestration in oil reservoirs can be one of the most effective strategies for long-term removal of greenhouse gas from atmosphere. This paper presents an advantage of the localized nonlinear approximation of integral equation solutions for inverting crosswell electromagnetic data, which are observed as a part of pilot project of $CO_2$ flooding at the Lost Hills oil field in central California, U.S.A. To monitor the migration of $CO_2$, we have used 2-D cylindrically symmetric and 2.5-D tomographic inversion methods. These two schemes produce nearly the same images if the borehole separation is large compared with the skin depth. However, since the borehole separation is much less than five skin depths in this $CO_2$ injection experiment, the 2.5-D model seems to be more reliable than the 2-D model. In fact, the pre-injection 2.5-D image is more successfully compared with induction logs observed in the two wells than the 2-D model. From the time-lapse crosswell imaging, we can confirm the replacement of brine with $CO_2$ makes a decrease of conductivity.

  • PDF

Counterfeit Detection Using Characterization of Safety Feature on Banknote with Full-field Optical Coherence Tomography

  • Choi, Woo-June;Min, Gi-Hyeon;Lee, Byeong-Ha;Eom, Jong-Hyun;Kim, Ju-Wan
    • Journal of the Optical Society of Korea
    • /
    • v.14 no.4
    • /
    • pp.316-320
    • /
    • 2010
  • We report an application of full-field optical coherence tomography (FF-OCT) for identifying counterfeit bank notes. The depth-resolved imaging capability of FF-OCT was used for tomographic identification of superficially-identical objects. By retrieving the internal structures of the security feature (cash hologram) of an original banknote, we could demonstrate the feasibility of FF-OCT to identify counterfeit money. The FF-OCT images showed that the hologram consisted of micron scale multi-coated layers including an air gap. Therefore, it is expected that FF-OCT has potential as a new non-invasive tool to discern imitation of currency, and it would find applications in a wide field of counterfeit sciences.

Differentiation of Canine Calcium Oxalate and Canine Struvite Stones using Computed Tomography (개에서 전산화단층촬영을 이용한 Calcium Oxalate결석과 Struvite결석의 감별)

  • Yoon, Young-Min;Lee, Hee-Chun
    • Journal of Veterinary Clinics
    • /
    • v.32 no.1
    • /
    • pp.69-72
    • /
    • 2015
  • This study was performed to differentiate calcium oxalate and struvite canine urinary stones using computed tomography. A total of 38 urinary stones (8 calcium oxalate and 30 struvite) were scanned using a computed tomography scanner. These urinary stones (10-15 mm diameter) extracted surgically without fragmentation were obtained from the different individual patients. The stone's Hounsfield units(HU) values, heterogenicity, and roughness of surface were evaluated to differentiate calcium oxalate and struvite. The HU values of calcium oxalate were significantly higher than those of struvite. A receiver operator characteristic (ROC) curve revealed 1272 as the best threshold value to distinguish calcium oxalate from struvite (ROC curve AUC 0.87, p < 0.0014). The heterogenicity of calcium oxalate and struvite significantly differed on bone and dental window setting (p < 0.0001). There was no significant difference between calcium oxalate and struvite in roughness of surface. On computed tomographic images, bone and dental windows setting were useful for evaluation of heterogenicity between calcium oxalate and struvite. The HU value and heterogenicity are highly promising factor that can distinguish calcium oxalate and struvite with reasonable accuracy.

Three-dimensional symmetry and parallelism of the skeletal and soft-tissue poria in patients with facial asymmetry

  • Kim, Min-Gun;Lee, Jin-Woo;Cha, Kyung-Suk;Chung, Dong-Hwa;Lee, Sang-Min
    • The korean journal of orthodontics
    • /
    • v.44 no.2
    • /
    • pp.62-68
    • /
    • 2014
  • Objective: The purpose of this study was to examine the symmetry and parallelism of the skeletal and soft-tissue poria by three-dimensional (3D) computed tomographic (CT) imaging. Methods: The locations of the bilateral skeletal and soft-tissue poria in 29 patients with facial asymmetry (asymmetric group) and 29 patients without facial asymmetry (symmetric group) were measured in 3D reconstructed models of CT images by using a 3D coordinate system. The mean intergroup differences in the anteroposterior and vertical angular deviations of the poria and their anteroposterior and vertical parallelism were statistically analyzed. Results: The symmetric and asymmetric groups showed significant anteroposterior angular differences in both the skeletal and the soft-tissue poria (p = 0.007 and 0.037, respectively; Mann-Whitney U-test). No significant differences in the anteroposterior and vertical parallelism of the poria were noted ($p{\leq}0.05$; Wilcoxon signed-rank test). Conclusions: In general, the skeletal poria are parallel to the soft-tissue poria. However, patients with facial asymmetry tend to have asymmetric poria.

Assessment of accessory mandibular canal in mandibular third molars using cone-beam computed tomography (콘빔 CT를 이용한 하악 제3대구치부의 부하악관 평가)

  • Cho, Bong-Hae;Jung, Yun-Hoa
    • The Journal of the Korean dental association
    • /
    • v.52 no.12
    • /
    • pp.753-761
    • /
    • 2014
  • Purpose: This study was performed to examine distribution of accessory mandibular canal and its characteristics in mandibular third molars. Materials and methods: A total of 251 subjects (166 males and 85 females) having mandibular third molars bilaterally were included in the study. Cone-beam computed tomographic images were reviewed for bifid or trifid accessory mandibular canal. The prevalence of accessory mandibular canal was evaluated according to gender, side and its branching type. Proximity and crosssectional position of accessory mandibular canal to mandibular third molar was analyzed. Results: Accessory mandibular canals were found in 66 (26.3%) of 251 patients and 86 (17.1%) of 502 hemi-mandibles. Gender and sides showed no statistically significant differences in prevalence. Retromolar canal (46.1%) was the most common branching type. Proximity of accessory canal to mandibular third molars showed mean distance of 2.8 mm from third molar and a statistically significant difference was found among types of accessory canal. Dental canal was the closest to tooth among branching types and closer to tooth than main canal. On cross-sectional view, accessory canal was generally located on buccal side of mandibular third molar. Conclusion: Accessory mandibular canal was common and well detected with cone-beam computed tomography. Their localization is significant in all anesthetic and surgical procedures involving mandibular third molars.

Evaluation of antral exostoses in a Korean population (한국인의 상악동 외골증 평가)

  • Cho, Bong-Hae;Jung, Yun-Hoa
    • The Journal of the Korean dental association
    • /
    • v.55 no.3
    • /
    • pp.208-214
    • /
    • 2017
  • Purpose: This study was performed to survey the incidence and imaging characteristics of the antral exostoses in a Korean population. Materials and methods: The cone-beam computed tomographic images of 5,268 patients were reviewed for the presence of antral exostoses. Incidence, location, shape, structure and dimension were evaluated. Gender and side difference were analyzed by chi-squared test. Results: Ninety eight antral exostoses were found in 78 (1.5%) out of 5,268 patients. Gender and sides showed no statistically significant differences. Antral exostoses was often found in the lateral wall and floor of the maxillary sinus, accounting for 58.2% and 38.8% of the exostoses, respectively. Most exostoses had broad base and were composed of spongy bone surrounded by compact bone. The mean dimension was 9.1(W)*4.9(D)*5.3(H) mm. Conclusion: Antral exostoses is not uncommon in a Korean population. The identification of antral exostoses is clinically significant to avoid unnecessary examination and treatment. It also needs to be examined carefully in the implant planning or sinus lift procedure.

  • PDF

Air-coupled ultrasonic tomography of solids: 1 Fundamental development

  • Hall, Kerry S.;Popovics, John S.
    • Smart Structures and Systems
    • /
    • v.17 no.1
    • /
    • pp.17-29
    • /
    • 2016
  • Ultrasonic tomography is a powerful tool for identifying defects within an object or structure. But practical application of ultrasonic tomography to solids is often limited by time consuming transducer coupling. Air-coupled ultrasonic measurements may eliminate the coupling problem and allow for more rapid data collection and tomographic image construction. This research aims to integrate recent developments in air-coupled ultrasonic measurements with current tomography reconstruction routines to improve testing capability. The goal is to identify low velocity inclusions (air-filled voids and notches) within solids using constructed velocity images. Finite element analysis is used to simulate the experiment in order to determine efficient data collection schemes. Comparable air-coupled ultrasonic signals are then collected through homogeneous and isotropic solid (PVC polymer) samples. Volumetric (void) and planar (notch) inclusions within the samples are identified in the constructed velocity tomograms for a variety of transducer configurations. Although there is some distortion of the inclusions, the experimentally obtained tomograms accurately indicate their size and location. Reconstruction error values, defined as misidentification of the inclusion size and position, were in the range of 1.5-1.7%. Part 2 of this paper set will describe the application of this imaging technique to concrete that contains inclusions.

Two Cases of Bronchopulmonary Dysplasia of Similar Appearance in Adult Monozygotic Twin: Pathology and Computed Tomographic Findings

  • Lee, Yoon Pyo;Chun, Eun Mi;Kim, Yoo Kyung;Sung, Sun Hee
    • Tuberculosis and Respiratory Diseases
    • /
    • v.78 no.2
    • /
    • pp.128-132
    • /
    • 2015
  • Bronchopulmonary dysplasia (BPD) is related to decreased lung function throughout life. However, the pathology and radiology pattern of BPD of adults are not documented well yet. In this case report, we present BPD case of an adult monozygotic twin showing nearly identical lesions on chest computed tomography (CT). CT images showed mixed areas of ground-glass and reticular opacities in both lungs. They had common histories of pneumonias requiring mechanical ventilations in period of infants. Pulmonary function test of one patient showed a pulmonary insufficiency with airway obstruction. Pathologic findings showed bronchiolar hyperplasia and peribronchiolar fibrosis which was similar to classic BPD patients. Our twin case report might help provide distinguishing pathology and radiology pattern of an adult pulmonary sequelaes of BPD. It might be reasonable to make close follow-up for BPD patients to evaluate the long-term outcomes of BPD survivors.