Immediate Distal Digit Reconstruction with Short Vascular Pedicled Partial Toe Transfer (짧은 혈관경을 가진 부분 족지 전이술을 이용한 수지첨부의 즉시 재건)

  • Park, Sun-Hee;Kim, Hak-Soo;Kim, Seong-Eon
    • Archives of Reconstructive Microsurgery
    • /
    • v.21 no.1
    • /
    • pp.27-33
    • /
    • 2012
  • We studied the results of the immediate microsurgical reconstruction of the distal digit injury with short vascular pedicled partial toe transfer. Thirteen patients with amputation or crush injury of the distal digit who underwent partial toe transfer at the authors' institute over 8-year period were reviewed. Delay between initial injury and reconstruction ranged from 1 to 9 days. All flaps were harvested on a short vascular pedicle, with anastomoses performed at a proximal interphalangeal joint level on the fingers and metacarpophalangeal joint level on the thumbs. Good to excellent cosmetic and functional results were obtained in all cases, with nearly normal-looking fingertip. The mean static two point discrimination was 10 mm. Immediate reconstruction with short vascular pedicled partial toe transfer is an excellent option for the reconstruction of the compostie defect of the distal digit.

  • PDF

A Study for Plastic Toe-Cap of Safety Shoes (안전화 경량화를 위한 플라스틱 Toe-Cap에 관한 연구)

  • 조광수;김인관;강태호;김영수
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1450-1453
    • /
    • 2003
  • Safety-shoes are developed for heavy industry. Nowadays with the development of industry, it is increase on all of industry field. Safety-shoes are to be classfied into using intention. And it's developed not only protect from danger but also more comfort wearing. When wear a safety shoes, in cold weather, serious disease could be occur such as frostbitten and so on. In the study replacees steel toe-cap by polymer. When it replace by polymer, Moreover add keeping warm, light weighting, chemicals-proof. Nowadays plastic material can exchanged from metal, because of rapid growth in engineering plastic and FRP. Prodcts of engineering plastic and FRP goods are equal. So we develop plastic Toe-Cap using plastic technology.

  • PDF

A Model Estimating the Fatigue Crack Growth in Aluminum Alloy A5083-O Considering the Effect of Stress Concentration (응력집중의 영향을 고려한 알루미늄합금 A5083-O의 피로균열전파 특성 예측모델)

  • 조상명;김종호;김영식
    • Journal of Welding and Joining
    • /
    • v.12 no.3
    • /
    • pp.90-100
    • /
    • 1994
  • In this study the fatigue crack growth behavior was investigated for the surface cracks in aluminum alloy A5083-O plate and its weldment. Several kinds of specimens were tested at room temperature. The Eccentric specimens(E1.0, E2.5) subjected to combined stresses(tension+bending) were tested and the welded specimens with weld toes(TOE1, TOE2) were tested in order to verify the method to consider the stress concentration such as weld toe. It was ascertained that the surface crack growth property in the weld toe could be predicted by the corrected Pang's equation proposed in this study.

  • PDF

Analysis on the Fatigue Crack Propagation of Weld Toe Crack through Residual Stress Field (잔류응력장을 전파하는 용접 토우부 균열의 전파해석)

  • 김유일;전유철;강중규;한종만;한민구
    • Journal of Welding and Joining
    • /
    • v.18 no.5
    • /
    • pp.33-40
    • /
    • 2000
  • Fatigue crack propagation life of weld toe crack through residual stress field was estimated with Elber's crack concept. Propagation of weld toe crack is heavily influenced by residual stress caused by welding process, so it is essential to take into account the effect of residual stress on the propagation life of weld toe crack. Fatigue crack at transverse and longitudinal weld toe was studied respectively, which represent typical weld joint in ship structure. Numerical and experimental studies are performed for both cases. Residual stress near weldment was estimated through nonlinear thermo-elasto-plastic finite element method, and residual stress intensity factor with Glinka's weight function method. Effective stress intensity factor was calculated with Newman-Forman-de Koning-Henriksen equation which is based on Dugdale strip yield model in estimating crack closure level U at different stress ratio. Calculated crack propagation life coincided well with experimental results.

  • PDF

The IPSec Systems on TOE for Gigabit Network (기가비트 네트워크 지원을 위한 TOE 기반 IPSec 시스템)

  • Shin, Chi-Hoon;Kim, Sun-Wook;Park, Kyoung;Kim, Sung-Woon
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.1035-1038
    • /
    • 2005
  • This paper describes the designs and the implementations of two H/W IPSec Systems, look-aside and inline, on TOE (Transport Offloading Engine). These systems aim for guaranteeing the security of datagram networks while preserving the bandwidth of gigabit networks. The TOE offloads a host CPU from network burdens, so that it makes the gigabit wire speed possible, and then deeper level security architecture of the IPSec guarantees the security of gigabit service network dominated by datagram packets. The focus of this paper is to minimize the TOE's performance degradation caused by the computation-oriented IPSec. The look-aside IPSec system provides a significant improvement in the CPU offload of the IPSec cryptography loads. However, the inline system completely offloads the host CPU from whole IPSec loads, providing significant additional cost saving compared to the look-aside system. In this paper, the implementations of TOE cards including commercial IPSec processors are presented. As the result of performance evaluation with the protocol analyzer, we can get the fact that the inline IPSec system is 8 times faster than the S/W system and 2 times faster than the look-aside system.

  • PDF

Epidemiological Investigation of Onychomycosis and Tinea Pedis in Children (소아의 손·발톱 및 족부백선증에 관한 역학적 조사)

  • Bang, Young-Jun;Kim, Ssang-Young
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.39 no.2
    • /
    • pp.91-95
    • /
    • 2007
  • The number of children patients with tinea pedis and onychomycosis diagnosed on clinical findings and culture at the Catholic Dermatological Clinic in Daegu City were 144,446 for 2 years from January 2005 to December 2006. 120 children were suspected of having clinical onychomycosis or tinea pedis. KOH smears and cultures on the Potato corn meal dextrose agars (PDCA) were done for the suspected toe webs, nails and uninvolved neighbor toe webs. Socks were dusted and cultured to check contamination of clothes. Family infections were checked by questionnaire. The incidence was 92 (0.06%) out of 144,446 outpatients in tinea pedis, 28 (0.02%) in onychomycosis. Trichophyton(T.) rubrums were isolated from all of the 7 cases of onychomycosis. T. mentagrophytes was isolated from 5 cases of the tinea pedis patients and T. rubrum was isolated from 50 (92.5%) cases of the tinea pedis. The right side was predominant for onychomycosis of both toe nails (23 of 25) and finger nails (3 of 3). No fungal elements were detected from normal looking neighbor toe webs by KOH examinations. However, culture on PDCA agars showed T. rubrum isolates from 3 toe webs. 7 showed positive cultures from the socks. From the questionnaire, 94 had family infections.

  • PDF

Relationship between Shoes Wearing by Adult Woman and Foot type (성인 여성의 구두착용과 발 유형과의 관계)

  • 최순복;이원자
    • Journal of the Korean Home Economics Association
    • /
    • v.40 no.10
    • /
    • pp.231-241
    • /
    • 2002
  • This study is for research of relationship between shoes wearing by adult woman and foot type. The research was made through questionnaire sheets of general matters (age, body weight, height & occupation) and shoes wearing status (hill height, toe shape, wearing time) of 216 adult women reside in the metropolitan zone and the foot type was classified from foot measurement and the relationship between shoes wearing and foot type was analyzed. According to the result of analysis it is as follows : 1) In the shoes type prefer for they prefer for lower hill as more ages and were preferring shoes with higher hill as the taller women. 2) The instep height is lower and medial foot angle was increased as their ages are more. Majority of foot type was appeared with standard type and the broad type was indicated more by age of 20s. The classification by toe the square type was indicated by majority and in the age of 30-40s the egyptian type was more 3) As the age and weight get increased he height of arch become lower and indicated to transit to flat-foot. That is to say they prefer for round toe in case of fiat-foot, and for square toe in case of normal and, choice of shoe toe shape it indicated by more impact by the height of arch rather than toe length.

Effects of Wearing Toe Braces of Hallux Valgus on Gait during Virtual Environment Simulation (무지외반증 발가락 교정기 착용 여부가 가상 환경 시뮬레이션 시 보행에 미치는 영향)

  • Dong-Su Kim;Da-Eun Lee;Hyun-A Shin;Ji-Won Jeon;Young-Keun Woo
    • PNF and Movement
    • /
    • v.21 no.1
    • /
    • pp.27-35
    • /
    • 2023
  • Purpose: Hallux valgus (HV) is one of the most common chronic foot disorders, occurring when the first toe deviates laterally toward the other toe. HV impairs muscle strength and affects gait function (postural sway and gait speed). Thus, this study aims to investigate using the FDM system the effect of wearing braces on gait while wearing a virtual reality (VR) device. Methods: This study was conducted on 28 healthy adults with HV of 15 degrees or more. To compare differences in walking, depending on whether a toe brace can be worn, the subject walked without wearing anything, walked after wearing the VR device, and walked after wearing the VR device and the toe brace, and the FDM system was used for the gait ability measurement analysis. Results: As a result of a one-way repeated analysis of variance, the walking speed-related variables (cadence, velocity, etc.) in the HV group were higher during comfortable walking. In addition, walking while wearing a VR device and walking while wearing a VR device and a toe brace demonstrated more significant values in terms of six gait parameters (double stance phase, loading response, stage, stage, stage, and stage). The maximum pressure of the forefoot was significantly reduced when walking while wearing a VR device and a toe brace compared to comfortable walking, but in all variables, there was no statistically significant difference between walking while wearing a VR device and walking while wearing a VR device and a toe brace. Conclusion: Orthosis with a VR device during gait (OVG) and gait with a VR device (GVR) affect gait in HV patients. However, there was no significant difference between GVR and OVG. Thus, it is necessary to conduct experiments on various HV angles and increase the duration of wearing the toe brace.

Range of Motion of Great Toe after Sesamoidectomy: A Cadaveric Study (종자골 절제 후 족무지 관절의 운동 변화)

  • Chung, Hyun-Wook;Kim, Jin-Goo;Lee, Woo-Chun;Moon, Jeong-Seok;Suh, Jin-Soo
    • Journal of Korean Foot and Ankle Society
    • /
    • v.13 no.2
    • /
    • pp.138-141
    • /
    • 2009
  • Purpose: Regardless of potential and actual complications, the sesamoidectomy either tibial side or fibular side or both, had been used as a surgical option for various pathologic conditions. The objective of this cadaveric study was to identify the changes of range of motion of great toe after sesamoidectomy. Material and Methods: Eight fresh cadaver legs were used. The angular changes of the hallucal articulations were measured by traction of the flexor hallucis longus tendon at the proximal border of fibro-osseous tarsal tunnel and by traction of the extensor hallucis longus tendon at the superior border of inferior extensor retinaculum. The measurement started at neutral position and proceeded to the maximum for respective tendons. After sesamoidectomy either partial or total, same procedures were repeated and the angular changes were measured. Results: In flexion of great toe, there were significant metatarsophalangeal angular differences at 1 cm traction in total sesamoidectomy and lateral sesamoidectomy. In extension of great toe, there were significant metatarsophalangeal angular differences at more than 2 cm traction in total sesamoidectomy. In other measurements, there were no significant angular changes of the hallucal articulations. Conclusion: The sesamoidectomy resulted in change of motion of great toe. Statistical analysis showed that the significant increases in the initial flexion and maximal extension occurred with total sesamoidectomy and the significant increase in the initial flexion occurred with lateral sesamoidectomy.

  • PDF

Optimum Design of Front Toe Angle Using Design of Experiment and Dynamic Simulation for Evaluation of Handling Performances (실험계획법을 이용한 전륜 토우각의 최적설계 및 조종 안정성능 평가 시뮬레이션)

  • 서권희;민한기;천인범
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.8 no.2
    • /
    • pp.120-128
    • /
    • 2000
  • At the initial design stage of a new vehicle, the chassis layout has the most important influence on the overall vehicle performance. Most chassis designers have achieved the target performances by trial and error method as well as individual knowhow. Accordingly, a general procedure for determining the optimum location of suspension hard points with respect to the kinematic characteristics needs to be developed. In this paper, a method to optimize the toe angle in the double wishbone type front suspension of the four-wheel-drive vehicle is presented using the design of experiment, multibody dynamic simulation, and optimum design program. The handling performances of two full vehicle models having the initial and optimized toe angle are compared through the single lane change simulation. The sensitive design variables with respect to the kinematic characteristics are selected through the experimental design sensitivity analysis using the perturbation method. An object function is defined in terms of the toe angle among those kinematic characteristics. By the design of experiment and regression analysis, the regression model function of toe angle is obtained. The design variables which make the toe angle optimized ae extracted using the optimum design program DOT. The single lane change simulation and test of the full vehicle model are carried out to survey the handling performances of vehicle with toe angle optimized. The results of the single lane change simulation show that the optimized vehicle has the more improved understeer tendency than the initial vehicle.

  • PDF