• Title/Summary/Keyword: tissue compliance

Search Result 49, Processing Time 0.026 seconds

Finite Element Analysis of End-to-End Anastomosis of Coronary Artery with Elastic Surrounding Tissue (탄성경계조직을 가진 관상동맥의 end-to-end 문합에 대한 유한요소해석)

  • Han, Geun-Jo;Kim, Tae-Hyung;Ahn, Sung-Chan;Shim, Jae-Joon
    • Proceedings of the KSME Conference
    • /
    • 2001.11a
    • /
    • pp.442-447
    • /
    • 2001
  • A finite element analysis of end-to-end artery/PTFE anastomosis has been presented in this study to evaluate the distribution of compliance in the vicinity of the anastomosis due to any mismatch in compliance characteristics. But, In these studies it was assumed that the artery and PTFE have the simple cylindrical shape representing the fatty tissue surrounding the coronary artery. And the fatty tissue was considered as the elastic surrounding materials in the finite element analysis. The simulation results were obtained as follows : 1. A fatty tissue was effect to reduce the compliance mismatch in the vicinity of a artery/PTFE anastomosis of different material because a hypercompliant zone become narrorw and a compliance discrepancy decrease between the artery and the PTFE about 70%. And radial direction displacement distribution with respect to distance in the vicinity of a artery/PTFE anastomosis was similiar. 2. The variation of PTFE thckness reduce the compliance mismatch in the vicinity of a artery/PTFE anastomosis about 25%.

  • PDF

The study for Compliance Mismatch in the End-to-End Anastomosis of Coronary Artery and PTFE (관상동맥과 PTFE의 End-To-End 문합에서 컴플라이언스 부적합에 관한 연구)

  • Shim,, Jae-Joon;Han, Geun-Jo;Ahn, Sung-Chan
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.1
    • /
    • pp.34-41
    • /
    • 2003
  • Finite element analysis of end-to-end artery/PTFE anastomosis recently have been researched. But, these studies were carried out without the compensation for the error of finite element analysis and assumed the artery and PTFE as the simple cylindrical shape in spite of being the fatty tissue which covers the heart. Therefore, we performed the convergency study with respect to increasing the element numbers and considered the fatty tissue as the elastic foundation in the finite element analysis. The results are as fallow : 1. An anastomosis with the thinner thickness and larger diameter PTFE than artery could reduce the compliance disagreement. 2. A fatty tissue was affected to reduce the compliance mismatch in the vicinity of anastomosis of different material. Therefore a hypercompliant zone become narrorw and a compliance discrepancy decrease between the artery and the PTFE about 70%. And radial displacement with respect to longitudinal direction of an artery and the PTFE anastomosis was similar to a sectional compliance.

The Study on Compliance Mismatch with respect to the Thickness Variation of Elastic Foundation in Anastomosis Using Simplified Suturing Model (단순봉합모델을 이용한 문합에서 탄성경계층의 두께 변화에 따른 컴플라이언스 부적합에 관한 연구)

  • 이성욱;심재준;한동섭;한근조;김태형
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1302-1305
    • /
    • 2003
  • In this paper we analyzed the effect of compliance mismatch with respect to the thickness variation of elastic foundation(fatty tissue) in end-to-end anastomosis. This study considered the preliminary deformed shape induced by suturing in the anastomosis of coronary artery and PTFE with different diameters using simplified suturing model and the fatty tissue surrounding heart and coronary artery for more accurate result using finite element method. Area compliance(C$\sub$A/) was used to analyze the final deformed shape of the anastomotic part with respect to the thickness variation of fatty tissue under mean blood pressure, 100 mmHg(13.3kPa). The results obtained were as follows : 1. When the elastic foundation, assumed to be incompressive material, surrounded the grafts in anastomosis, the compliance mismatch of artery and PTFE was improved by 47∼72%. 2. As the initial diameter ratio(R$\sub$I/) became larger, the higher difference of compliance was induced in spite of elastic foundation surrounding grafts.

  • PDF

A Study on Muscle Architectural and Tissue Compliance of Biceps Brachii in Stroke Patient Based on Elbow Joint Angle (뇌졸중 환자에서 주관절 각도 변화에 따른 상완이두근의 근구조 및 탄성 변화에 관한 연구)

  • Bae, Sea-Hyun;Jeong, Chan-Joo;Kim, Kyung-Yoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.12
    • /
    • pp.5867-5874
    • /
    • 2012
  • The aim of this study was to find on muscle architectural and tissue compliance of biceps brachii in stroke patient based on elbow joint angle. The subjects of this study were twelve hemiplegic adults after stroke with passive range of motion in the elbow from $10^{\circ}$ to $90^{\circ}$ and Modified Ashworth Scale score 1 to 3 were recruited. Ultrasonography and Myotonometer was used to measure biceps brachii muscle pennation angle, fascicle length, and tissue compliance at the rest condition and pennation angle, fascicle length, and tissue compliance of the biceps brachii muscle were measured in the affected and unaffected sides of people after stroke at 9 different elbow angles ranging from $10^{\circ}$ to $90^{\circ}$ at the rest condition. The results of this study, comparisons found that the pennation angles of the affected biceps brachii muscle were significantly larger(p<.05) than the unaffected muscle in the most extended positions($<40^{\circ}$), whereas the affected fascicle lengths were significantly shorter(p<.05) than the unaffected muscle in most flexed positions($>20^{\circ}$), and the affected tissue compliance were significantly lower(p<.05) than the unaffected muscle in most extended positions($<50^{\circ}$) Therefore, pennation angles, fascicle lengths, and tissue compliance were found to be joint-angle-dependent in both the affected and unaffected sides at the rest condition. Suggest that, the results data can be used as a muscle architectural changes and clinical treatment research in stroke patients.

The Study on the Mechanical Behavior of the Anastomosis with respect to the Thickness Variation of Elastic Foundation Using Simplified Suturing Model (단순봉합모델을 이용한 문합에서 탄성경계층의 두께 변화에 따른 기계역학적 거동에 관한 연구)

  • 이성욱;한근조;심재준;한동섭;김태형
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.8
    • /
    • pp.188-195
    • /
    • 2004
  • In this paper we analyzed the mechanical behavior with respect to the thickness variation of elastic foundation(fatty tissue) in end-to-end anastomosis. This study considered the preliminary deformed shape induced by suturing in the anastomosis of coronary artery and PTFE with different diameters using simplified suturing model and the fatty tissue surrounding heart and coronary artery for more accurate result using finite element method. Area compliance(CA) was used to analyze the final deformed shape of the anastomotic part with respect to the thickness variation of fatty tissue under mean blood pressure, 100mmHg(13.3㎪). And Equivalent and circumferential stresses in the anastomosis were also analyzed with respect to the change of initial diameter ratio( $R_1$) and fatty tissue thickness( $T_{F}$). The results obtained were as follows : 1 When the elastic foundation, assumed to be incompressive material, surrounded the grafts in anastomosis, the compliance mismatch of artery and PTFE was reduced by 47 -72%. 2. As the initial diameter ratio( $R_1$) became larger, the higher difference of compliance was induced in spite of elastic foundation surrounding grafts. 3. The maximum nondimensional circumferential stress is twice or three times as high as the maximum nondimensional equivalent stress in the anastomotic part.t.

Antispastic Effects of Electroacupuncture, TENS and NMEs in Stroke Patient (중풍경직에 전침, TENS 및 신경근 자극기의 효과에 대한 연구)

  • Kim, Yong-suk
    • Journal of Acupuncture Research
    • /
    • v.17 no.2
    • /
    • pp.209-220
    • /
    • 2000
  • Spasticity, an abnormal increase in resting muscle tone, is one of the most common symptoms of stroke, and its management is becoming a major issue in rehabilitation. The aims of this study are to determine the effects of electroacupuncture(EA), TENS and neuromuscular electric stimulation(NMES) on spasticity, as well as the possibility of tissue comliance method as a spasticity scale. 45 stroke patients participated in a study of the effects on hemiplegic spasticity of EA, TENS and NMES. Spasticity was measured by modified Ashworth scale on the upper extremity and tissue compliance measurement, penetration mm/kg, on Susamni(LI10) area at just before and after stimulation, and 30 minutes, 1 hour, 2 hours and 24 hours after stimulation. The acupuncture points were applied to Kokchi(LI11), Susamni(LI10), Hapkok(LI4) and Oegwan(TE5) of the affected limb. The electrodes were placed unilaterally on LI11 to LI10 and TE5 to LI4. EA with biphasic wave, 60Hz, 0.4 msec pulse duration and low intensity was applied continuously for 20 minutes. TENS with high frequency, low intensity was applied. NMES was applied with spasticity program for 20 minutes. Each electric stimulation was done on extensor muscles group of forearm for 20 minutes. EA and NMES groups were found to produce a statistically significant decrease(p〈0.05) of spasticity and these effects lasted up to 30 minutes after stimulation. There was no definite correlation between the modified Ashworth scale and tissue compliance measurement. But tissure compliance method was found to be possible as a quantitative measurement on spasticity. There was no significant correlation between the effects of EA and NMES and the characteristics of patient, but significant correlation between the effects of EA and NMES and the modified Ashworth scale.

  • PDF

Measurement of Biomechanical Property of Chondrocyte (연골세포의 기계적 물성치 측정)

  • ;Daehwan Shin
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.154-157
    • /
    • 2002
  • A cyto-indentation technique was used to obtain the biomechanical compressive compliance property of an chondrocyte cell attached to glass surface, which was tried to generate joint cartilage by tissue engineering. Piezo-transducer system and dual photo-diode system were used to conduct mechanical indentation through displacement-controlled testing and the measurement of corresponding cell reaction force. The Poisson's ratio of 0.37 was quoted from other report. The compressive compliance of chondrocyte, that was determined by elastic contact theory, was 1.38${\pm}$0.057 kPa. This value is 30% higher than that of MG63 osteoblast-like cell. The cyto-indentation technique employed in this study is so precise that it can quantify the biomechanical property of single cell.

  • PDF

Knowledge and Compliance with Cough Etiquette among Elderly in the Community (지역사회 거주 노인의 기침예절에 관한 지식과 실천도)

  • Song, Min Sun;Yang, Nam Young
    • Journal of Korean Academic Society of Home Health Care Nursing
    • /
    • v.24 no.1
    • /
    • pp.52-60
    • /
    • 2017
  • Purpose: This study sought to identify the relationship between knowledge and compliance with cough etiquette among elders in the community. Methods: Participants were 186 olders. Data were collected December 2016 and analyzed using descriptive statistics, t-test, ANOVA, Pearson correlation coefficients, and stepwise multiple regression. Results: Mean scores for knowledge and compliance relating to cough etiquette were above average. Several factors were related to significant differences in level of knowledge: education level, use of items to cover a cough, Carrying a handkerchief or tissue, daily frequency of hand washing, awareness of cough etiquette, and prior education on cough etiquette. Compliance differed according to use of items to cover a cough, awareness of cough etiquette, and prior education on cough etiquette. Significant correlations were found between knowledge and compliance with cough etiquette. Awareness of cough etiquette and knowledge of cough etiquette were predictors of cough etiquette compliance. Conclusion: These findings indicate that publicity and education taking into account the characteristics of the elderly are required to improve compliance with cough etiquette among olders. The results of the study can be utilized in health promotional programs for this population.

Development of the Pulsatile Pump System for a Perfusion Bioreactor (관류형 바이오리액터를 위한 박동 펌프 시스템 개발)

  • Kim, Hak-Jun;Kim, Sun-Hong;Chung, Ho-Yun;Yun, Won-Soo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.4
    • /
    • pp.526-533
    • /
    • 2011
  • This research is about the pulsatile pump system utilized in the perfusion bioreactor for the in vitro human tissue culture. A pulsatile pump system which can be applied to the culture of the vascular tissues including blood vessel is developed by using the idea of human heart's blood pumping into organs as followings: culture chamber, a pressurizing device which generates laminar pulsatile flow by controlling the x-sectional area of the culture media delivering tubing, a compliance chamber which supplies the pressuring device with a constant pressure, and a peristaltic pump which circulates the culture media in a circuit ranging from the culture chamber to the compliance chamber. The developed pulsatile pump system shows that a physiology of the human heart's blood pumping including pulsatile pressure waveform of systolic-diastolic pressure is well represented. Not only time domain but also frequency domain characteristics of pulsatile pump system which are necessary for the vascular tissue culture such as pulsatile pressure waveform's shape, the frequency, and the magnitude can be easily generated and manipulated by using the proposed system.

Tactile Response Characteristics of Haptic Displays based on Magneto-Rheological Fluids (MR 유체를 이용한 햅틱 디스플레이의 질감 반응 특성)

  • Jang, Min-Gyu;Choi, Jea-Young;Lee, Chul-Hee
    • Tribology and Lubricants
    • /
    • v.26 no.3
    • /
    • pp.184-189
    • /
    • 2010
  • In this paper, tactile response characteristics in medical haptic interface are investigated to characterize the feeling of contact between the finger skin and the organic tissue when a finger is dragged over tissue. In order to represent the tactile feeling, a prototype tactile display incorporating Magneto-Rheological (MR) fluid has been developed. Tactile display devices simulate the finger's skin to feel the sensations of contact such as compliance, curvature and friction. Thus, the tactile display provides the surface information of organic tissue to the surgeon using different actuating mechanisms ranging from the conventional mechanical motor to the smart material actuators. In order to investigate the compliance feeling of human finger's touch, vertical force responses of the tactile display under the various magnetic fields have been assessed. Also, frictional resistive force responses of the tactile display are investigated to simulate the action of finger's dragging. From the results, different tactile feelings are observed as the applied magnetic field is varied and arrayed magnetic poles combinations. This research gives a smart technology of tactile displaying.