• Title/Summary/Keyword: tip shape

Search Result 575, Processing Time 0.026 seconds

Modeling and optimal design of monolithic precision XYZ-stage using flexure mechanism (유연기구를 이용한 초정밀 단일체 3축 스테이지의 모델링 및 최적설계에 관한 연구)

  • Shim, Jong-Yeop;Gweon, Dae-Gab
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.22 no.4
    • /
    • pp.868-878
    • /
    • 1998
  • There are recently increasing needs for precision XYZ-stage in the fields of nanotechnology, specially in AFMs(Atomic Force Microscope) and STMs(Scanning Tunneling Microscope). Force measurements are made in the AFM by monitoring the deflection of a flexible element (usually a cantilever) in response to the interaction force between the probe tip and the sample and controlling the force neasyred constant topography can be obtained. The power of the STM is based on the strong distance dependence of the tunneling current in the vacuum chamber and the current is a feedback for the tip to trace the surface topography. Therefore, it is required for XYZ-stage to position samples with nanometer resolution, without any crosscouples and any parasitic motion and with fast response. Nanometer resolution is essential to investigate topography with reasonable shape. No crosscouples and parasitic motion is essential to investigate topography without any shape distortion. Fast response is essential to investigate topography without any undesirable interaction between the probe tip and sample surface ; sample scratch. To satisfy these requirements, this paper presents a novel XYZ-stage concept, it is actuated by PZT and has a monolithic flexible body that is made symmetric as possible to guide the motion of the moving body linearly. PZT actuators have a very fast response and infinite resolution. Due to the monolithic structure, this XYZ-stage has no crosscouples and by symmetry it has no parasitic motion. Analytical modeling of this XYZ-stage and its verification by FEM modeling are performed and optimal design that is to maximize 1st natural frequencies of the stage is also presented and with that design values stage is manufactured.

Various Methods of Reconstruction in Nasal Defect (코 결손 부위에 따른 다양한 재건)

  • Kim, Seok Kwun;Yang, Jin Il;Kwon, Yong Seok;Lee, Keun Cheol
    • Archives of Craniofacial Surgery
    • /
    • v.11 no.1
    • /
    • pp.13-18
    • /
    • 2010
  • Purpose: Nasal defect can be caused by excision of tumor, trauma, inflammation from foreign body reaction. Nose is located in the middle of face and protruded, reconstruction should be done in harmony with size, shape, color, and textures. We report various methods of nasal reconstruction using local flaps. Methods: From March 1998 to July 2008, 36 patients were operated to reconstruct the nasal defects. Causes of the nasal defects were tumor (18 cases), trauma (11 cases), inflammation from foreign body reaction (5 cases) and congenital malformation (2 cases). The sites of the defects were ala (22 cases), nasal tip (8 cases) and dorsum (6 cases). The thickness of the defects was skin only (5 cases), dermis and cartilagenous layer (7 cases) and full-thickness (24 cases). According to the sites and thickness of the defects, various local flaps were used. Most of alar defects were covered by nasolabial flaps or bilobed flaps and the majority of dorsal and tip defects were covered by paramedian forehead flaps. Small defects below $0.25 cm^2$ were covered with composite graft or full-thickness skin graft. Results: The follow-up period was 14 months. Partial flap necrosis was observed in a case, and one case of infection was reported, it was improved by wound revision and antibiotics. Nasal reconstruction with various local flaps could provide satisfactory results in terms of color and texture match. Conclusion: The important factors of nasal reconstruction are the shape of reconstructed nose, color, and texture. Nasolabial flap is appropriate method for alar or columellar reconstruction and nasolabial island flap is suitable for tip defect. The defect located lateral wall could be reconstructed with bilobed flap for natural color and texture. Skin graft should be considered when the defect could not afford to be covered by adjacent local flap. And entire nasal defect or large defect could be reconstructed by paramedian forehead flap.

EFFECT OF THE SHAPE OF IMPINGEMENT PLATE ON THE VAPORIZATION AND FORMATION OF FUEL MIXTURE IN IMPINGING SPRAY

  • Kang, J.J.;Kim, D.W.;Choi, G.M.;Kim, D.J.
    • International Journal of Automotive Technology
    • /
    • v.7 no.5
    • /
    • pp.585-593
    • /
    • 2006
  • The effect of the shape of the side wall on vaporization and fuel mixture were investigated for the impinging spray of a direct injection(DI) gasoline engine under a variety of conditions using the LIEF technique. The characteristics of the impinging spray were investigated under various configurations of piston cavities. To simulate the effect of piston cavity configurations and injection timing in an actual DI gasoline engine, the parameters were horizontal distance from the spray axis to side wall and vertical distance from nozzle tip to impingement plate. Prior to investigating the side wall effect, experiments on free and impinging sprays for flat plates were conducted and these results were compared with those of the side wall impinging spray. For each condition, the impingement plate was located at three different vertical distances(Z=46.7, 58.4, and 70 mm) below the injector tip and the rectangular side wall was installed at three different radial distances(R=15, 20, and 25 mm) from the spray axis. Radial propagation velocity from spray axis along impinging plate became higher with increasing ambient temperature. When the ambient pressure was increased, propagation speed reduced. High ambient pressures tended to prevent the impinging spray from the propagating radially and kept the fuel concentration higher near the spray axis. Regardless of ambient pressure and temperature fully developed vortices were generated near the side wall with nearly identical distributions, however there were discrepancies in the early development process. A relationship between the impingement distance(Z) and the distance from the side wall to the spray axis(R) was demonstrated in this study when R=20 and 25 mm and Z=46.7 and 58.4 mm. Fuel recirculation was achieved by adequate side wall distance. Fuel mixture stratification, an adequate piston cavity with a shorter impingement distance from the injector tip to the piston head should be required in the central direct injection system.

Electro-fatigue Characteristic of Shape Memory Alloy Applied to the Electrosurgical Knee Wand of Variation of Wand Head Angle in Electrosurgical Knee Surgeries (헤드각이 변화하는 Electrosurgical Knee Wand에 적용된 형상기억합금 스프링의 전기적 피로특성)

  • An, Jae-Uk;Kim, Cheol-Woong;Lee, Ho-Sang;Wang, Joon-Ho;Oh, Dong-Joon
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1547-1552
    • /
    • 2008
  • The tip of these catheter with straight needles is not able to reach in the vicinity of the disc bulging, which are the cause of the low back pain and because the far indirect radio-frequency treatment results in the decompression, the nucleoplasty has the limit. Many incurable diseases has not been solved due to the unexistence of the advanced technique for the MIS human body catheter device. To increase the possibility of nucleoplasty, the needle tip should be located at the closest area of the lesion. For this reason, the best way to increase the success rate of the operation is that the needle tip should access 3-dimensionally to the operating field as soon as possible. To achieve this aim, our studies are restricted as follows: 1) the SMA catheter design to control the 3-dimensional direction, 2) the security of the immediate response by the positive control of the SMA element thermal distribution using Peltier thermoelectric elements, 3) the aquisition of the control data by monitoring the relationship between the temperature of SMA element and the displacement, and 4) the design of the controller to guarantee the accurate location.

  • PDF

The Alar Extension Graft for Retracted Ala (Alar Extension Graft를 이용한 콧방울뒤당김의 교정)

  • Kim, Hyun soo;Roh, Si Gyun
    • Archives of Plastic Surgery
    • /
    • v.36 no.1
    • /
    • pp.66-74
    • /
    • 2009
  • Purpose: The importance of the deformities in alar - columellar complex has been underestimated in Asian ethnic groups for the last decades. Fortunately, with increasing familiarity of the open rhinoplasty techniques, the anatomic details of the nasal tip have been pointed up. Definitely, having an interest and demand for improving the sub - normal relationship between the alar rim and columella are indebted for such growing of knowledge about nasal tip anatomy. However, it is true that any single procedure is not settled as versatile and fully confident modality to correct the retracted notching of the alar rim. With this article, I should like to propose another useful option for treating retracted ala. Methods: The author has tried to correct alar rim retraction by means of: (1) Triangular onlay septal cartilage graft on the lower lateral cartilage with the medial end fixed to the anterior surface of the lateral crus(Alar extension graft), (2) Inserting lateral end of the alar extension graft to the vestibular skin pocket in the form of a finger - in - groove, (3) using the vestibular skin in the form of an advancement flap, and (4) using the soft shield graft to prevent possible visible step - off of the alar margin. Results: The author applied an alar extension graft to 16 patients in order to correct a retracted ala for the last 27 months (August, 2003 - October, 2005). The distances from alar rim to long axis of nostril were improved to be within 2 mm in all of the cases, and also the shape of the alar rim changed to a round form. Nostril asymmetry (6%) in one case, temporary palpable step - off (18%) in three cases, temporary visible step - off (6%) in one case, and temporary paresthesia of the tip (25%) in four cases were observed. Conclusion: The alar extension graft is simple and efficacious. It does not need donor sites other than the operative field, and its results are predictable. In particular, since it may give structural intensity to a weak lower lateral cartilage, it may be preferentially used for the correction of a retracted ala that arises from hypoplastic lower lateral cartilage. Moreover intensified lower lateral cartilage also improves the esthetic shape of lobule.

Tip Clearance Effects on Inlet Hot Streaks Migration Characteristics in Low Pressure Stage of a Vaneless Counter-Rotating Turbine

  • Zhao, Qingjun;Wang, Huishe;Zhao, Xiaolu;Xu, Jianzhong
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.03a
    • /
    • pp.25-34
    • /
    • 2008
  • In this paper, three-dimensional multiblade row unsteady Navier-Stokes simulations at a hot streak temperature ratio of 2.0 have been performed to reveal the effects of rotor tip clearance on the inlet hot streak migration characteristics in low pressure stage of a Vaneless Counter-Rotating Turbine. The hot streak is circular in shape with a diameter equal to 25% of the high pressure turbine stator span. The hot streak center is located at 50% of the span and the leading edge of the high pressure turbine stator. The tip clearance size studied in this paper is 2.0mm(2.59% high pressure turbine rotor height, and 2.09% low pressure turbine rotor height). The numerical results show that the hot streak is not mixed out by the time it reaches the exit of high pressure turbine rotor. The separation of colder and hotter fluid is observed at the inlet of low pressure turbine rotor. Most of hotter fluid migrates towards the rotor pressure surface, and only little hotter fluid migrates to the rotor suction surface when it convects into the low pressure turbine rotor. And the hotter fluid migrated to the tip region of the high pressure turbine rotor impinges on the leading edge of the low pressure turbine rotor after it goes through the high pressure turbine rotor. The migration of the hotter fluid directly results in very high heat load at the leading edge of the low pressure turbine rotor. The migration characteristics of the hot streak in the low pressure turbine rotor are dominated by the combined effects of secondary flow and leakage flow at the tip clearance. The leakage flow trends to drive the hotter fluid towards the blade tip on the pressure surface and to the hub on the suction surface, even partial hotter fluid near the pressure surface is also driven to the rotor suction surface through the tip clearance. Compared with the case without rotor tip clearance, the heat load of the low pressure turbine rotor is intensified due to the effects of the leakage flow. And the numerical results also indicate that the leakage flow effect trends to increase the low pressure turbine rotor outlet temperature at the tip region.

  • PDF

Study of Materials and Stress Ratios on Fatigue Crack Propagation Rate Using Parameter ΔA (.DELTA.A를 파라미터로 이용한 피로크랙전파속도에 미치는 재료 및 응력비의 영향에 대한 연구)

  • 박영철;오세욱;김광영;허정원;강정호
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.7
    • /
    • pp.1373-1380
    • /
    • 1992
  • The local cyclic strain distribution near the crack tip has been investigated by the fine Dot Grid Strain Measurement Method, which had been suggested strain measurement method to resolve experimental difficulties by authors. It has been found that the magnitude of the local cyclic strain distribution(.DELTA..epsilon.$_{eq}$ )near a crack tip has been varied by the applied cyclic load level and material, but the shape of the local cyclic strain distribution near the crack tip has been experimentally scrarcely altered : that is .DELTA..epsilon.$_{eq}$ = .DELTA.A.f(.theta.). $r^{-1}$ . Consequently, the local cyclic strain field near the crack tip could be favorably characterized by a single parameter fatigue strain intensity factor .DELTA.A. In addition, with the viewpoint that .DELTA.A depends on material and load level, .DELTA.A has been applied to evaluate the fatigue crack propagation rate and usefulness of the result has been considered. As a result, it has been ascertained that .DELTA.A has been a useful parameter to evaluate the fatigue crack propagation rate.

Tip Plasty using Biodegradable Plate as a Columella Strut (비주 버팀목으로 흡수성 고정판을 이용한 비첨 성형술)

  • Kim, Soo-Young;Lee, Soo-Hyang;Hwang, Eun-A;Choi, Hyun-Gon;Kim, Soon-Heum;Shin, Dong-Hyeok;Uhm, Ki-Il
    • Archives of Plastic Surgery
    • /
    • v.37 no.3
    • /
    • pp.259-264
    • /
    • 2010
  • Purpose: Most surgeons have used autogenous cartilage for columella strut graft. But the supply of autogenous cartilage is often limited. So, this study is to investigate the usefulness of biodegradable plate as columella strut material. Methods: We studied 19 patients who have secondary cleft nasal deformity. Patients were divided into two groups. Group A patients who were not closed their growth plate underwent columella strut graft only with biodegradable plate through endonasal approach. The biodegradable plate was inserted between nasal tip and anterior nasal spine. Group B patients were closed their growth plate. They had an operation for columella strut graft with biodegradable plate fixed with autogenous conchal cartilage. If nasal tip projection was insufficient, we performed additionally onlay graft on nasal tip with autogenous soft tissue or remnant cartilage. Results: As a result of mean 14 months follow-up, we achieved a good nasal tip projection, narrowing of interalar distance and symmetrical nostril shape. No specific complications were reported except 2 cases, which were the extrusion of biodegradable plate into the nasal cavity and Staphylococcus aureus infection. Conclusion: The columella strut graft using biodegradable plate is simple and effective method. Biodegradable plate can be a good substitute for columella strut in patients who can not use autogenous cartilages.

Influence of Indenter Tip Geometry and Poisson's Ratio on Load-Displacement Curve in Instrumented Indentation Test (계장화 압입시험의 하중-변위 곡선에 미치는 선단 형상 및 푸아송비의 영향)

  • Lee, Jin Haeng
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.9
    • /
    • pp.943-951
    • /
    • 2014
  • The tip geometries of the pyramidal and conical indenters used for micro/nano-indentation tests are not sharp. They are inevitably rounded because of their manufacturability and wear. In many indentation studies, the tip geometries of the pyramidal indenters are simply assumed to be spherical, and the theoretical solution for spherical indentation is simply applied to the geometry at a shallow indentation depth. This assumption, however, has two problems. First, the accuracy of the theoretical solution depends on the material properties and indenter shape. Second, the actual shapes of pyramidal indenter tips are not perfectly spherical. Hence, we consider the effects of these two problems on indentation tests via finite element analysis. We first show the relationship between the Poisson's ratio and load-displacement curve for spherical indentation, and suggest improved solutions. Then, using a possible geometry for a Berkovich indenter tip, we analyze the characteristics of the load-displacement curve with respect to the indentation depth.

Reconstruction of cutaneous defects of the nasal tip and alar by two different methods

  • Kim, Yong Hun;Yoon, Hyung Woo;Chung, Seum;Chung, Yoon Kyu
    • Archives of Craniofacial Surgery
    • /
    • v.19 no.4
    • /
    • pp.260-263
    • /
    • 2018
  • Background: The alar and nasal tip are important subunits of the nose. Determining the optimal procedure for reconstructing a cutaneous defect in a nasal subunit depends on several factors including size, location, and involvement of deep underlying structures. We treated cutaneous defects after tumor ablation in the alar and nasal tip with a local flap, using an S-shaped design and a modified V-Y advancement flap with a croissant shape. Methods: We analyzed 36 patients with skin tumors who underwent flap coverage after tumor ablation. Rotation flaps were used in 26 cases and croissant-shaped V-Y advancement flaps were used in 10 cases. The primary cause of the defects was skin cancer, except for one benign tumor. Results: The mean patient age was 71 years. The size of the defects ranged from $0.49cm^2$ to $3.5cm^2$. No recurrence of skin cancer was noted and all flaps lasted until the end of follow-up. Partial desquamation of the epidermis was noted in one case. The postoperative appearance for most patients was excellent, objectively and subjectively. Conclusion: For cutaneous defects of up to about $4.0cm^2$ of the alar and nasal tip, local flaps using our methods offered a good cosmetic and therapeutic result. The main advantage of our flaps is the minimal dissection required compared to bilobed and other local flap methods. We believe our flaps are a suitable option for alar and nasal tip reconstruction.