• Title/Summary/Keyword: timing resolution

Search Result 99, Processing Time 0.033 seconds

Wideband Flat Optical Frequency Comb Generated from a Semiconductor Based 10 GHz Mode-Locked Laser with Intra-cavity Fabry-Perot Etalon

  • Leaird, Daniel E.;Weiner, Andrew M.;Seo, Dongsun
    • Journal of IKEEE
    • /
    • v.18 no.1
    • /
    • pp.19-24
    • /
    • 2014
  • We report stable, wideband, flat-topped, 10 GHz optical frequency comb generation from a semiconductor-based mode-locked ring laser with an intra-cavity high finesse Fabry-Perot etalon. We demonstrate a stable 10 GHz comb with greater than 200 lines within a spectral power variation below 1 dB, which is the largest value obtained from a similar mode-locked laser in our knowledge. Greater than 20 dB of the spectral peak to deep ratio at 0.02 nm resolution, ~92 femtosecond timing jitter over 1 kHz to 1 MHz range, and non-averaged time traces of pulses confirm very stable optical frequency comb lines.

ANALYSIS OF THE IMAGE SENSOR CONTROL METHOD

  • Park, Jong-Euk;Kong, Jong-Pil;Heo, Haeng-Pal;Kim, Young-Sun;Yong, Sang-Soon
    • Proceedings of the KSRS Conference
    • /
    • 2007.10a
    • /
    • pp.464-467
    • /
    • 2007
  • All image data acquisition systems for example the digital camera and digital camcorder, use the image sensor to convert the image data (light) into electronic data. These image sensors are used in satellite camera for high quality and resolution image data. There are two kinds of image sensors, the one is the CCD (charge coupled device) detector sensor and the other is the CMOS (complementary metal-oxide semiconductor) image sensor. The CCD sensor control system has more complex than the CMOS sensor control system. For the high quality image data on CCD sensor, the precise timing control signal and the several voltage sources are needed in the control system. In this paper, the comparison of the CCD with CMOS sensor, the CCD sensor characteristic, and the control system will be described.

  • PDF

Effect of two-photon spatial bunching on single photon detection rates (광자쌍의 뭉침현상이 단일계수에 미치는 영향)

  • 김헌오;신하림;박구동;김태수
    • Korean Journal of Optics and Photonics
    • /
    • v.14 no.6
    • /
    • pp.573-577
    • /
    • 2003
  • We report an effect of photon pairs on single-photon detection rates, while Hong-Ou-Handel's two-photon interference experiment is performed with photons produced in noncollinear type-I parametric down-conversion. Photon pairing behavior or spatial bunching is measured and shown to cause a decrease in the single photon counting rate. Such a dip is found to result from the fact that the single-photon timing resolution of photodetectors is much longer compared to the time interval between the two photons incident on the single-photon detector.

Optimal equivalent-time sampling for periodic complex signals with digital down-conversion

  • Kyung-Won Kim;Heon-Kook Kwon;Myung-Don Kim
    • ETRI Journal
    • /
    • v.46 no.2
    • /
    • pp.238-249
    • /
    • 2024
  • Equivalent-time sampling can improve measurement or sensing systems because it enables a broader frequency band and higher delay resolution for periodic signals with lower sampling rates than a Nyquist receiver. Meanwhile, a digital down-conversion (DDC) technique can be implemented using a straightforward radio frequency (RF) circuit. It avoids timing skew and in-phase/quadrature gain imbalance instead of requiring a high-speed analog-to-digital converter to sample an intermediate frequency (IF) signal. Therefore, when equivalent-time sampling and DDC techniques are combined, a significant synergy can be achieved. This study provides a parameter design methodology for optimal equivalent-time sampling using DDC.

Tropospheric Data of KASI GNSS Network (2001-2014) Based on the CODE's 2nd Reprocessing Product

  • Roh, Kyoung-Min;Park, Han-Earl;Choi, Byung-Kyu
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.9 no.3
    • /
    • pp.229-236
    • /
    • 2020
  • The trend of water vapor contents in atmosphere is one of key elements for studying climate change. The tropospheric products, i.e., ZTD values achieved through GPS data processing can retrieve the amount of water vapor with higher temporal and spatial resolution than any other instruments. In this study, the tropospheric products of KASINET for a time period from 2001 to 2014 are reprocessed using PPP strategy and the products from the CODE's 2nd reprocessing campaign. For consistency with reprocessing activities of other networks like EPN, the VMF1 mapping function and non-tidal loading effect due to atmospheric pressure are applied in the process. The reprocessing results are investigated through comparing with the CODE's 2nd reprocessing products by including some IGS stations in the process and also calculating weekly coordinate repeatability to see the quality of the processing. After removing outliers based on the variation of averaged formal error, all processed stations have similar variations of formal error about 2 mm which is lower than that of the IGS final product. Comparison results with the CODE's 2nd reprocessing products show that the overall mean difference is found to be -0.28±5.54 mm which is similar level of the previous studies. Finally, the ZTD trends of all KASINET stations are calculated and the averaged trend is achieved as 0.19 mm/yr. However, the trend of each month shows different amounts and directions from -1.26 mm/yr in May to 1.18 mm/yr in August. In conclusion, the reprocessed tropospheric product and applied strategy of this study has enough quality as one of reliable solution for a reference product for Korean Peninsula which is needed to use GPSbased tropospheric product for climate change research.

Contrast-Enhanced MR Angiography of Supra-Aortic Arteries: Review of Current Techniques, Diagnostic Accuracy and Common Pitfalls in Steno-Occlusive Diseases

  • Lee, Jeong-Hyun;Kim, Jin-Hyoung;Kim, Hyun-Jeong;Park, Choong-Gon;Lee, Deok-Hee;Lee, Ho-Kyu;Kim, ang-Joon;Suh, Dae-Chul
    • Proceedings of the KSMRM Conference
    • /
    • 2003.10a
    • /
    • pp.97-97
    • /
    • 2003
  • Contrast-enhanced MR angiography (CE-MRA) gradually occupies its position as a primary evaluation tool forsteno-occlusive disease of supra-aortic cervical arteries. It has several advantages over time-of-flight (TOF) technique such as shorter imaging time, less saturation effect, and less flow- and motion-related artifacts. Diverse methods of k-space sampling, imaging sequences, and strategies for image acquisitiontiming have been introduced since its early clinical application. Especially, methods of k-space sampling and image acquisition timing are very important to achieve maximal arterial enhancement and suppress venous signal while maintaining large scan coverage and high spatial resolution. In addition, regardless of several advantages over TOF technique, it still has a tendency to overestimate the degree of stenosis in patients with carotid or vertebralartery disease. In this exhibit, we will overview the current techniques of CE-MRA with special attention to methods of k-space sampling and image acquisition timing. We will also discuss diagnostic accuracy of CE-MRA in patients with supra-aortic cervical artery stenosis and artifacts frequently misinterpreted as steno-occlusive lesion on CE-MRA.

  • PDF

The Hida metamorphic belt developed near the triple junction among the Sino-Korea, Yangtze and Proto-Pacific plates

  • Kunugiza, Keitaro
    • Proceedings of the Mineralogical Society of Korea Conference
    • /
    • 2002.05a
    • /
    • pp.1-3
    • /
    • 2002
  • The eastward extension of the suture zone between the Sino-Korea and Yangtze cratons in the Korean Peninsula and Japanese islands remains debatable (Hiroi, 1981; Cluzel et al., 1991; Yin and Nie, 1993; Sohma and Kunugiza, 1993; Isozaki, 1997; Arakawa et at., 2000), and is related to our understanding of the continent-continent collision orogeny. The collision orogeny varies in tectono-metamorphic processes and the timing differs from place to place, as exemplified by the absence of coesite and micro-diamond in the Korean Peninsula and Japanese islands, because it is a long-lived process of more than several tens of million years from subduction to exhumation in the Wilson cycle, and because the suture zone extends more than several thousand kilometers with a curved shape from the Qinling area of China to the Hida highland area of Japan. Hiroi (1981) is the first paper to correlate the Unazuki metamorphic rocks of the Hida metamorphic belt in Japan with the Ogcheon belt in the Korean Peninsula based on the presence of 240 Ma medium P/T metamorphic rocks in both belts, but there is a lack of recent studies on this correlation. To resolve the correlationship, there are two approaches: 1) petrological studies characterizing the origin and P-T history of rocks and 2) in-situ micro-dating of fine-grained, zoned minerals of zircon, monazite, uraninite and thorite using the EPMA (U-Th-Pb chemical dating or CHIME depending on calibration method) and the SHRIMP (Sensitive High-resolution ion Microprobe) to decipher the timing of geological events. As a first step of these approaches, micro-dating was undertaken to rocks of the Hida metamorphic belt and its Mesozoic cover (Tetori Group) in the Hida highland area, central Japan.

  • PDF

Scintillation Characteristics of CsI:X(X=Li+,K+,Rb+ Single Crystals (CsI:X(X=Li+,K+,Rb+단결정의 섬광특성)

  • Gang, Gap-Jung;Doh, Sih-Hong;Lee, Woo-Gyo;Oh, Moon-Young
    • Journal of Sensor Science and Technology
    • /
    • v.12 no.1
    • /
    • pp.1-9
    • /
    • 2003
  • CsI single crystals doped with lithium, potassium or rubidium were grown by using Czochralski method at Ar gas atmosphere. The energy resolutions of CsI(Li:0.2 mole%), CsI(K:0.5 mole%) and CsI(Rb:1.5 mole%) scintillators were 14.5%, 15.9% and 17.0% for $^{137}Cs$(0.662 MeV), respectively. The energy calibration curves of CsI(Li), CsI(K) and CsI(Rb) scintillators were linear for $\gamma$-ray energy. The time resolutions of CsI(Li:0.2 mole%), CsI(K:0.5 mole%) and CsI(Rb:1.5 mole%) scintillators measured by CFT(constant-fraction timing method) were 9.0 ns, 14.7 ns and 9.7 ns, respectively. The fluorescence decay times of CsI(Li:0.2 mole%) scintillator had a fast component and slow one of ${\tau}_1=41.2\;ns$ and ${\tau}_2=483\;ns$, respectively. The fluorescence decay times of CsI(K:0.5 mole%) scintillator were ${\tau}_1=47.2\;ns$ and ${\tau}_2=417\;ns$. And the fluorescence decay times of CsI(Rb:1.5 mole%) scintillator were ${\tau}_1=41.3\;ns$ and ${\tau}_2=553\;ns$. The phosphorescence decay times of CsI(Li:0.2 mole%), CsI(K:0.5 mole%) and CsI(Rb:1.5 mole%) scintillators were 0.51 s, 0.57 s and 0.56 s, respectively.

Scintillation Characteristics of CsI(Li) Single Crystals (CsI(Li) 단결정의 섬광특성)

  • Lee, W.G.;Doh, S.H.;Ro, T.I.;Kim, W.;Kang, H.D.;Moon, B.S.
    • Journal of Sensor Science and Technology
    • /
    • v.8 no.5
    • /
    • pp.359-367
    • /
    • 1999
  • CsI(Li) single crystals doped with 0.02, 0.1, 0.2 and 0.3 mole% lithium as an activator were grown by Czochralski method. The lattice structure of grown CsI(Li) single crystal was bcc, its lattice constant was $4.568\;{\AA}$. The absorption edge of CsI(Li) single crystal was 245 nm, and the spectral range of luminescence was $300{\sim}600\;nm$, its maximum luminescence intensity appeared at 425 nm. The energy resolutions of CsI(Li) single crystal doped with 0.2 mole% lithium were 14.5% for $^{137}Cs$(662 keV), 11.4% for $^{54}Mn$(835 keV) and 17.7% and 7.9% for $^{22}Na$(511 keV and 1275 keV), respectively. The relation formula of $\gamma$-ray energy versus energy resolution was ln (FWHM%) = -0.893lnE + 8.456 and energy calibration formula was ${\log}E_r=1.455\;{\log}(ch.)-1.277$. The phosphorescence decay time of CsI(Li) crystal doped with 0.2 mole% lithium was 0.51 s at room temperature, and its time resolution measured by CFT(constant-fraction timing method) was 9.0 ns.

  • PDF

Time-to-Digital Converter Implemented in Field-Programmable Gate Array using a Multiphase Clock and Double State Measurements (Field Programmable Gate Array 기반 다중 클럭과 이중 상태 측정을 이용한 시간-디지털 변환기)

  • Jung, Hyun-Chul;Lim, Hansang
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.8
    • /
    • pp.156-164
    • /
    • 2014
  • In a delay line type of a time-to-digital converter implemented in Field Programmable Gate Array, the timing accuracy decreases for a longer carry chain. In this paper, we propose a structure that has a multi-phase clock and a state machine to check metastability; this would reduce the required length of the carry chain with the same time resolution. To reduce the errors caused by the time difference in the four delay lines associated with a four-phase clock, the proposed TDC generates a single input pulse from four phase clocks and uses a single delay line. Moreover, the state machine is designed to find the phase clock that is used to generate the single input pulse and determine the metastable state without a synchronizer. With the measurement range of 1 ms, the measured resolution was 22 ps, and the non-linearity was 25 ps.