• Title/Summary/Keyword: time-varying characteristics

Search Result 650, Processing Time 0.035 seconds

Pulsatility Estimation of a Pulsatile Decellularizing Device for the Fabrication of Organ Scaffold (생체장기용 지지체 제작을 위한 박동형 탈세포화 장치의 박동성 평가)

  • Kim, Dong Sun;Yang, Se-Ran;Park, Sung Min;Choi, Seong Wook
    • Journal of Biomedical Engineering Research
    • /
    • v.38 no.2
    • /
    • pp.62-73
    • /
    • 2017
  • To identify a solution for the restricted availability of healthy lungs and the high risk of immune rejections following organ transplantation, tissue engineering techniques for culturing lungs have been studied by many research groups. The most promising method for culturing lungs is the utilization of a bio-scaffold that was prepared using harvested organs from human donors or other animals by removing their original cells. In this study, a pulsatile perfusion pump was used to alleviate the cell removal effect with the high fluid-dynamic power of the perfusion stream during the decellularization process, while other conventional studies focused on chemical methods to identify efficient detergents. The purpose of this study was to analyze the developed device by using energy equivalent pressure (EEP), which is an indicator of pulsatility, to understand the characteristics of pulsatile energy transmitted according to the load size by using the artificial model and compare it with the measured EEP. The pulsatility of the device can be estimated with the concept of fluid-dynamic energy during a particular constant time period or fluid-dynamic power represented as EEP and EEP increment. Because the measured EEP of perfusion flow during decellularization can be changed by the amount of fluid leakage and the degree of clogging in the capillary vessels, EEP should be measured to determine whether the decellularization is progressing without problems. The decrement of EEP caused by the high perfusion resistance was observed from some experimental results that were obtained with artificial models. EEP can be used to monitor the decellularization process after analyzing the varying EEP according to the amount of load. It was confirmed that the EEP was maintained at a high level in the experiment using the harvested lungs from 12-13-week-old rats. In addition, it was confirmed that the cell removal time was faster than when continuous perfusion was performed. In this study, pulsatile power delivered to the lungs was measured to monitor the process of cell removal, and it serve as the evidence for efficient decellularization.

An Analysis and Assessment of Diagnostic and Therapeutic Process in Some Frequent Admissions and Operations (일부 다빈도 입원 및 수술례의 진단과 치료과정에 대한 연구)

  • Kim, Chang-Yup;Kim, Yoon;Kwon, Young-Dae;Kim, Yong-Ik;Shin, Young-Soo;Ahn, Hyeong-Sik
    • Journal of Preventive Medicine and Public Health
    • /
    • v.26 no.3 s.43
    • /
    • pp.400-411
    • /
    • 1993
  • The aim of this study is to analyze the variations among hospitals and hospital groups in resource use and procedures of diagnostic and therapeutic process, such as laboratory tests, radiologic examinations, tissue diagnosis, timing of surgery after admission, the time required for operation. The study was performed for five procedures including cesarean section (C/S), appendectomy, cholecystectomy, cataract extraction, and pediatric pneumonia. The 2,316 subjects were selected from medical insurance claims list, and from this list 413 cases were sampled for medical record review. The patterns of resource utilization and process of treatment were described according to hospitals and characteristics of hospital groups. The major results were as follows : 1. The numbers of laboratory and radiologic tests showed significant difference among hospitals and hospital groups. In case of hospital groups, we could find tendencies of more tests with increasing hospital bed size. 2. In general, the proportion of operative cases evaluated by tissue diagnosis postoperatively among all operations ranged from 28.3% to 100%. The proportion varied among hospital groups, of which general hospital A group(more than 15 specialty) showed the highest proportion. 3. Post-admission delay until operation and the time required for operative procedure were not invariable among hospitals and hospital groups. The duration of operation in tertiary hospitals was slightly shorter than general hospitals, with varying statistical significance. We could find that probably there were differences of quality among hospitals in some components of procedures, which suggested that the implementation of quality assurance activities would be mandatory. In this study, we simply described the patterns of resource utilization and some features of clinical process, with institution of the need for advanced studies with in-depth analyses for each component of diagnosis and treatment procedures.

  • PDF

A Study on the Characteristics of Underwater Sound Transmission by Short-term Variation of Sound Speed Profiles in Shallow-Water Channel with Thermocline (수온약층이 존재하는 천해역에서 단기간 음속구조 변화에 따른 음향 신호 전달 변동에 관한 연구)

  • Jeong, Dong-Yeong;Kim, Sea-Moon;Byun, Sung-Hoon;Lim, Yong-Kon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.34 no.1
    • /
    • pp.20-35
    • /
    • 2015
  • Underwater acoustic channel impulse responses (CIR) are influenced by sound speed profile (SSP), and the variation of CIR has significant effects on the performance of underwater acoustic communication systems. A significant change of SSP can occur within a short period, which must be considered during the design of underwater acoustic modems. This paper statistically analyzes the effect of the variation of SSP on the long-range acoustic signal propagation in shallow-water with thermocline using numerical modeling based on the data acquired from JACE13 experiment near Jeju island. The analysis result shows that CIR changes variously according to the SSP and the depth of the transmitter and receiver. We also found that when the transmitter and receiver are deeper, the variation of sound wave propagation pattern is smaller and signal level becomes higher. All CIR obtained in this study show that a series of bottom reflections due to downward refraction and small bottom loss in the shallow water with thermocline can be very important factor for long-range signal transmission and the performance of underwater acoustic communication system in time varying ocean environment can be very sensitive to the variation of SSP even for a short period of time.

Formation of Si Nanodot by Using SiNx Thin Films (SiNx 박막을 이용한 Si Nanodot의 형성)

  • Lee, Jang Woo;Park, Ik Hyun;Shin, Byul;Chung, Chee Won
    • Applied Chemistry for Engineering
    • /
    • v.16 no.6
    • /
    • pp.768-771
    • /
    • 2005
  • The deposition of silicon nitride ($SiN_x$) thin films was carried out on $SiO_2/Si$ substrate at room temperature by reactive dc magnetron sputtering. The analysis of deposited $SiN_x$ films using x-ray photoelectron spectroscopy indicated that the composition of $SiN_x$ films was Si-rich. The deposited $SiN_x$ thin films were annealed by varying annealing temperature and time. X-ray diffraction (XRD) analysis was performed in order to examine the crystallization of Si in $SiN_x$ thin films. The optical and electrical properties of $SiN_x$ thin films were measured for the observation of Si nanodot. As a result, we observed the XRD peaks that might be the Si crystals. As the annealing time and annealing temperature increased, the photoluminescence intensity of $SiN_x$ films gradually increased. The capacitance-voltage characteristics of $SiN_x$ film measured before and after annealing indicated that the trap effect of electrons or holes occurred due to the existence Si nanodots in the $SiN_x$ thin films.

A Time Slot Assignment Scheme for Sensor Data Compression (센서 데이터의 압축을 위한 시간 슬롯 할당 기법)

  • Yeo, Myung-Ho;Kim, Hak-Sin;Park, Hyoung-Soon;Yoo, Jae-Soo
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.15 no.11
    • /
    • pp.846-850
    • /
    • 2009
  • Recently, wireless sensor networks have found their way into a wide variety of applications and systems with vastly varying requirements and characteristics such as environmental monitoring, smart spaces, medical applications, and precision agriculture. The sensor nodes are battery powered. Therefore, the energy is the most precious resource of a wireless sensor network since periodically replacing the battery of the nodes in large scale deployments is infeasible. Energy efficient mechanisms for gathering sensor readings are indispensable to prolong the lifetime of a sensor network as long as possible. There are two energy-efficient approaches to prolong the network lifetime in sensor networks. One is the compression scheme to reduce the size of sensor readings. When the communication conflict is occurred between two sensor nodes, the sender must try to retransmit its reading. The other is the MAC protocol to prevent the communication conflict. In this paper, we propose a novel approaches to reduce the size of the sensor readings in the MAC layer. The proposed scheme compresses sensor readings by allocating the time slots of the TDMA schedule to them dynamically. We also present a mathematical model to predict latency from collecting the sensor readings as the compression ratio is changed. In the simulation result, our proposed scheme reduces the communication cost by about 52% over the existing scheme.

Studies on Changes in the Hydrography and Circulation of the Deep East Sea (Japan Sea) in a Changing Climate: Status and Prospectus (기후변화에 따른 동해 심층 해수의 물리적 특성 및 순환 변화 연구 : 현황과 전망)

  • HOJUN LEE;SUNGHYUN NAM
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.28 no.1
    • /
    • pp.1-18
    • /
    • 2023
  • The East Sea, one of the regions where the most rapid warming is occurring, is known to have important implications for the response of the ocean to future climate changes because it not only reacts sensitively to climate change but also has a much shorter turnover time (hundreds of years) than the ocean (thousands of years). However, the processes underlying changes in seawater characteristics at the sea's deep and abyssal layers, and meridional overturning circulation have recently been examined only after international cooperative observation programs for the entire sea allowed in-situ data in a necessary resolution and accuracy along with recent improvement in numerical modeling. In this review, previous studies on the physical characteristics of seawater at deeper parts of the East Sea, and meridional overturning circulation are summarized to identify any remaining issues. The seawater below a depth of several hundreds of meters in the East Sea has been identified as the Japan Sea Proper Water (East Sea Proper Water) due to its homogeneous physical properties of a water temperature below 1℃ and practical salinity values ranging from 34.0 to 34.1. However, vertically high-resolution salinity and dissolved oxygen observations since the 1990s enabled us to separate the water into at least three different water masses (central water, CW; deep water, DW; bottom water, BW). Recent studies have shown that the physical characteristics and boundaries between the three water masses are not constant over time, but have significantly varied over the last few decades in association with time-varying water formation processes, such as convection processes (deep slope convection and open-ocean deep convection) that are linked to the re-circulation of the Tsushima Warm Current, ocean-atmosphere heat and freshwater exchanges, and sea-ice formation in the northern part of the East Sea. The CW, DW, and BW were found to be transported horizontally from the Japan Basin to the Ulleung Basin, from the Ulleung Basin to the Yamato Basin, and from the Yamato Basin to the Japan Basin, respectively, rotating counterclockwise with a shallow depth on the right of its path (consistent with the bottom topographic control of fluid in a rotating Earth). This horizontal deep circulation is a part of the sea's meridional overturning circulation that has undergone changes in the path and intensity. Yet, the linkages between upper and deeper circulation and between the horizontal and meridional overturning circulation are not well understood. Through this review, the remaining issues to be addressed in the future were identified. These issues included a connection between the changing properties of CW, DW, and BW, and their horizontal and overturning circulations; the linkage of deep and abyssal circulations to the upper circulation, including upper water transport from and into the Western Pacific Ocean; and processes underlying the temporal variability in the path and intensity of CW, DW, and BW.

A Hydrodynamic Modeling Study to Analyze the Water Plume and Mixing Pattern of the Lake Euiam (의암호 수체 흐름과 혼합 패턴에 관한 모델 연구)

  • Park, Seongwon;Lee, Hye Won;Lee, Yong Seok;Park, Seok Soon
    • Korean Journal of Ecology and Environment
    • /
    • v.46 no.4
    • /
    • pp.488-498
    • /
    • 2013
  • A three-dimensional hydrodynamic model was applied to the Lake Euiam. The lake has three inflows, of which Gongji Stream has the smallest flow rate and poorest water. The dam-storage volume, watershed area, lake shape and discharge type of the Chuncheon Dam and the Soyang Dam are different. Therefore, it is difficult to analyze the water plume and mixing pattern due to the difference of the two dams regarding the amount of outflow and water temperature. In this study, we analyzed the effects of different characteristics on temperature and conductivity using the model appropriate for the Lake Euiam. We selected an integrated system supporting 3-D time varying modeling (GEMSS) to represent large temporal and spatial variations in hydrodynamics and transport of the Lake Euiam. The model represents the water temperature and hydrodynamics in the lake reasonably well. We examined residence time and spreading patterns of the incoming flows in the lake based on the results of the validated model. The results of the water temperature and conductivity distribution indicated that characteristics of upstream dams greatly influence Lake Euiam. In this study, the three-dimensional time variable water quality model successfully simulated the temporal and spatial variations of the hydrodynamics in the Lake Euiam. The model may be used for efficient water quality management.

Spontaneous Resolution of Residual Pleural Thickening in Tuberculous Pleurisy (결핵성 흉막염 치료 후 잔여 흉막비후의 자연흡수)

  • Kyung, S.Y.;Kim, Y.J.;Lim, Y.H.;An, C.H.;Lee, S.P.;Park, J.W.;Jung, S.H.
    • Tuberculosis and Respiratory Diseases
    • /
    • v.59 no.1
    • /
    • pp.69-76
    • /
    • 2005
  • Background : Residual pleural thickening (RPT) is the most common complication of tuberculous pleurisy (TP), despite adequate anti-tuberculous chemotherapy. At the conclusion of treatment, 43-50% of patients present RPT, with its incidence varying according to the time of evaluation. To assess the spontaneous resolution of RPT, the RPT at the completion of treatment was compared with that at the final follow-up. The factors related to the development of RPT after the completion of treatment were also studied. Methods : The medical records of sixty four patients, diagnosed with TP between March 2001 and June 2003, were retrospectively. The RPT was measured at the completion of treatment and at the time of the final follow-up and the degree and frequency of RPT compared between the two measurements. Each time, the patients were divided into two groups: those with and without RPT. The clinical characteristics and the radiographic and pleural fluid findings of the two groups were compared. Results : Thirty six (56%) and 27 patients had RPT at the completion of treatment and at the time of the final follow-up, respectively (median follow up period: 8 months). Spontaneous resolution of the RPT was found in 9 patients (24%), and had decrease below 10mm in 15 (42%) during the follow-up period after treatment. The patients were initially divided into two groups: 36 and 27 patients with and without RPT, respectively. There was no predicting factor of RPT, with the exception of the presence of CRP, between the two groups. The patients were also separated into two groups at the time of final visit: 27 and 37 patients with and without RPT, respectively. The patients with RPT were found to have a lower total WBC count in pleural fluid. Conclusion : 57% of patients with RPT were found to have spontaneous resolution of the residual pleural thickening after completion of the chemotherapy. The time of evaluation for RPT and its predicting factors were decided after adequate follow-up, irrespective of the completion of treatment.

Effects of Depth and Duration of Water-logging on Growth and Yield at Germination and Seedling Stage in Tomato(Lycopersicon esculentum Mill.) (토마토(Lycopersicon esculentum Mill.)의 발아기(發芽期) 및 유묘기(幼苗期) 침수(浸水) 처리(處理)에 따른 생육(生育) 반응(反應))

  • Guh, Ja-Ock;Roh, Sang-Eun;Kuk, Yong-In;Chon, Sang-Uk;Lee, Young-Man;Oh, Yun-Jin
    • Korean Journal of Environmental Agriculture
    • /
    • v.15 no.4
    • /
    • pp.406-418
    • /
    • 1996
  • Tomatoes are water logged differently 0, 5, 10 and 15 cm, according to the developing stages such as germination and seedling stage under the condition of greenhouse. Along with this, they are treated according to the time condition such as 6, 12, 24, 48 and 120 hours. The results obtained are summarized as follows. 1. The result at germination stage Remarkable germination failure was observed when tomatoes were water-logged for 25 to 27 hours in the depth of 0 to 5 cm. Plant height recovered within 24 hours regardless of the water-logging depths. In the case of leaves, the recoverable time limit became shorter gradually in accordance with the increase of the water-logging depth. The decrease of the fresh weight showed acute response in the shoot rather than the root. It recovered with the 24 hours of water logging. Significant correlation was observed in all characteristics of plant height, number of leaves, fresh weight and germination rates according to the depth of water-logging. 2. The result at seedling stage Plant height recovered within the 24 hours of water-logging in the depth of 0 cm. On the deeper level, there was significant decrease regardless of time. With regard to the number of leaves, there was recovery up to 120 hours in the depth of 0 cm, up to 24 hours in the depth of 5 cm. There was, however, significant decrease when done for more than 6 hours on the deeper level. Growth of the shoot displayed the same tendency as in plant height and number of leave. The length of the longest root could be maintained by 80% in the water-logging of 0 cm compared with control. However in depth of 5 cm or more, it could not be maintained by the 120 hours water-logging. Root activity became conspicuously diminished with the logging over 0 cm. Respiration showed conspicuous decrease by the depth of 5 cm as a turning point. On the other hand, photosynthesis became decreased linearly by the depth of water-logging. Chlorophyll content displayed gradual decrease up to 48 hours, but conspicuously decreased up to 120 hours according to the varying depth of water-logging. Dieases tended to increase according to the depth and hours of water-logging. Diseases would be prevented by dint of insecticide, but there was no effect of fertilization. Weight and number of fruit per plant displayed gradual decrease as the depth and hours of water-logging became increased. Average weight of a fruit became increased. There was no statisticaly reciprocal effects between the depth and hours of water-logging. There was significant positive correlation among all the investigated characteristics, such as traits of growth and yield.

  • PDF

Comparison of the degree of conversion of light-cured resin cement in regard to porcelain laminate thickness, light source and curing time using FT-IR (도재 라미네이트 두께와 광원 및 광조사 시간에 따른 광중합형 레진 시멘트의 FT-IR을 이용한 중합도 비교)

  • Yuh, Chi-Sung;Kim, Jee-Hwan;Kim, Sun-Jai;Lee, Yong-Keun;Shim, June-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.4
    • /
    • pp.416-423
    • /
    • 2009
  • Statement of problem: The degree of light attenuation at the time of cementation of the PLV restoration depends on characteristics such as thickness, opacity and shade of the restorations, which interfere with light transmittance and, as a result, may decrease the total energy reaching the luting cement. Purpose: The purpose of this study was to compare the degree of conversion of light-cured resin cements measuring by FT-IR in regard to different thickness, light devices and curing time. Material and methods: In the control group, a clear slide glass (1.0 mm) was positioned between the light cured resin cement and light source. The specimens of ceramics were made with IPS Empress Esthetic. The ceramics were fabricated with varying thicknesses-0.5, 1.0, 1.5 mm with shade ETC1. Rely $X^{TM}$ Veneer with shade A3, light-cured resin cement, was used. Light-activation was conducted through the ceramic using a quartz tungsten halogen curing unit, a light emitting diode curing unit and a plasma arc curing unit. The degree of conversion of the light-cured resin cement was evaluated using FT-IR and OMNIC. One-way ANOVA and Tukey HSD test were used for statistical analysis ($\alpha$< .05). Results: The degree of conversion (DC) of photopolymerization using QTH and LED was higher than results of using PAC in the control group. After polymerization using QTH and LED, the DC results from the different ceramic thickness- 0.5 mm, 1.0 mm, 1.5 mm- did not show a significant difference when compared with those of control group. However, the DC for polymerization using PAC in the 1.5mm ceramic group showed significantly lower DC than those of the control group and 0.5 mm ceramic group (P<.05). At 80s and 160s, the DC of light-cured resin cement beneath 1.0 mm ceramic using LED was significantly higher than at 20s (P<.05). Conclusion: Within the limitation of this study, when adhering PLV to porcelain with a thickness between 0.5-1.5 mm, the use of PAC curing units were not considered however, light cured resin cements were effective when cured for over 40 seconds with QTH or LED curing units. Also, when curing the light cured resin cements with LED, the degree of polymerization was not proportional with the curing time. Curing exceeding a certain curing time, did not significantly affect the degree of polymerization.