• Title/Summary/Keyword: time-to-contact

Search Result 3,010, Processing Time 0.032 seconds

V-t Characteristics and Survival Probability of Turn-to-Turn Models for HTS Transformer (고온초전도 변압기를 위한 턴간 모델의 V-t 특성 및 생존 확률)

  • Baek, Seung-Myeong;Cheon, Hyeon-Gweon;Nguyen, Van-Dung;Seok, Bok-Yeol;Kim, Sang-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.356-362
    • /
    • 2004
  • Using multi wrapped copper by polyimide film for HTS transformer, the breakdown and V-t characteristics of two type models for turn-to-turn, one is point contact model, the other is surface contact model, were investigated under ac and impulse voltage at 77 K. A material that is Polyimide film (Kapton) 0.025 mm thickness is used for multi wrapping of the electrode. Statistical analysis of the results using Weibull distribution to examine the wrapping number effects on V-t characteristics under at voltage as well as breakdown voltage under ac and impulse voltage in $LN_2$ was carried. Also, survival analysis was performed according to the Kaplan-Meier method. The breakdown voltages for surface contact model are lower than that of the point contact model, because the contact area of surface contact model is wider than that of point contact model. At the same time, the shape parameter of the point contact model is a little bit larger than the of the surface contact model. The time to breakdown tn is decreased as the applied voltage is increased, and the lifetime indices slightly are increased as the number of layers is increased. According to the increasing applied voltage and decreasing wrapping number, the survival probability is increased.

  • PDF

Non-uniform virtual material modeling on contact interface of assembly structure with bolted joints

  • Cao, Jianbin;Zhang, Zhousuo;Yang, Wenzhan;Guo, Yanfei
    • Structural Engineering and Mechanics
    • /
    • v.72 no.5
    • /
    • pp.557-568
    • /
    • 2019
  • Accurate modeling of contact interface in bolted joints is crucial in predicting the dynamic behavior for bolted assemblies under external load. This paper presents a contact pressure distribution based non-uniform virtual material method to describe the joint interface of assembly structure, which is connected by sparsely distributed multi-bolts. Firstly, the contact pressure distribution of bolted joints is obtained by the nonlinear static analysis in the finite element software ANSYS. The contact surface around bolt hole is divided into several sub-layers, and contact pressure in each sub-layer is thought to be evenly. Then, considering multi-asperity contact at the micro perspective, the relationship between contact pressure and interfacial virtual material parameters for each sub-layer is established by using the fractal contact theory. Finally, an experimental platform for the dynamic characteristics testing of a beam lap structure with double-bolted joint is constructed to validate the efficiency of proposed method. It is found that the theoretical results are in good agreement with experimental results by impact response in both time- and frequency-domain, and the relative errors of the first four natural frequencies are less than 1%. Furthermore, the presented model is used to examine the effect of rough contact surface on dynamic characteristics of bolted joint.

A Study on Ozone Oxidation of Algae (조류의 오존산화에 관한 연구)

  • 김은호;성낙창;최용락
    • Journal of Life Science
    • /
    • v.9 no.5
    • /
    • pp.590-595
    • /
    • 1999
  • The objectives of this research were to estimate variation characteristics of TOC, UV-254 and NH4+-N, etc, if odorous generated algaes flowed into water treatment plant and they contacted with ozone known as typical advanced treatment. It was estimated that pH decreased from initial 7.4 to 2.1 after ozone contact 100min. pH declined to early 10min. suddenly and then pH drop did almost occur. TOC and UV-254 continued to decrease with passed time of ozone contact. NO3--N concentration was much higher than NH4+-N and NO2--N for whole test period. Because ozone oxidized organic matters as various kinds of ion material and ion intensity of sample was extended, conductivity showed high as passed time of ozone contact. Owing to ozone oxidation of algae, color did almost disappear after ozone contact 20min.

  • PDF

A Study on the Elastic-Plastic Contact Problem for Large Deformation (대변형 탄소성 접촉문제에 관한 연구)

  • 전병희
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1992.03a
    • /
    • pp.11-26
    • /
    • 1992
  • In this research, a numerical algorithm has been developed, which can be applied to the large deformation and large displacement contact problems between angle change have been proposed considering the change in geometric shape and rate of contact force. A set of linear simultaneous equations is constructed by adding the geometric shape change and contact conditions to the original stiffness matrix. A new method to determine time increment has been proposed based on Euler method, in which the condition to prevent the contact bodies from penetrating and overrunning each other has been taken into consideration. Practical application to contact problem is extrusion in which bodies are sliding along the contact boundary.

  • PDF

Analysis of the Bounce Phenomenon According to the Load of the Relay Contact (릴레이 접점의 부하에 따른 바운스 현상 분석)

  • Choi, Sun-Ho;Kim, Kwan-Sik;Ryu, Jae-Man;Huh, Chang-Su
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.2
    • /
    • pp.115-119
    • /
    • 2015
  • The power relay can be easily controlled with high voltage and current through the contacts. For this reason, has become widely used range in a variety of applications. In this study, we measured the contact resistance between the bouncing phenomenon of contact due to the change of load. The results of the experiment, the contact resistance increases with the deterioration of the contact, it is possible to predict the life of the relay contacts through the contact resistance. And relay bounce duration time have occurred in 3.5 ms or less. In addition, it is possible to use the results to design an arc suppression circuit device.

Experimental Study of Laser Assisted Microvascular Anastomosis(LAMA) Using the Nd:YAG Contact Laser (Laser를 이용한 새로운 미세혈관 문합술의 실험적 연구)

  • Cho, Jin-Hwan;Lim, Jae-Ho;Park, Seung-Ha;Kim, Woo-Kyung
    • Archives of Reconstructive Microsurgery
    • /
    • v.2 no.1
    • /
    • pp.82-92
    • /
    • 1993
  • A comparative study was undertaken to evaluate the contact Neo-dymium : yttrium aluminum garnet(Nd:YAG) laser system for vascular anastomosis of small caliber blood vessels(diameter 0.5-1.2 mm) in the animal model. In this study 40 femoral arteries and 40 femoral veins of Sprague-Dawley rats were anastomosed by contact laser assisted microvascular anastomosis(LAMA) utilizing 3 stay sutures which were placed 120 degrees apart and the intervals welded with contact Nd:YAG laser unit, conventionally sutured anastomosis(CSA) served as controls. The time needed for vascular anastomosis, patency rate(immediate postoperative, postoperative 2nd day, postoperative 1 week, postoperative 4 weeks), gross and microscopic evaluations were compared to conventional microsurgical suture technique. The results are as follows: 1. Postoperative patency rate was 82.5% for femoral artery and 75% for femoral vein by contact LAMA technique compared to 90% and 75% by CSA technique at postoperative 4 weeks. 2. Less time-consumed for arterial anastomosis by 6 minutes 23 seconds and venous anastomosis by 8 minutes 55 seconds with contact LAMA technique compared to CSA technique. 3. Grossly almost complete healing had taken place by postoperative 1 week by contact LAMA technique. 4. Aneurysm formation was 5% for femoral artery and 15% for femoral vein by contact LAMA technique compared to 5% and 10% respectively by CSA technique. 5. Microscopically, re-endothelization was complete by postoperative 7th day by contact LAMA technique. There was less medial hypertrophy and hyperplasia and also less inflammatory response compared to CSA.

  • PDF

A Study of the Effects of Behavior Contact in Early Mother-Infant Attachment (분만 직후 어머니의 신생아 접촉이 모아애착행위에 미치는 영향)

  • Sung Mi-Hae;Kim Mi-Kyung
    • Journal of Korean Academy of Nursing
    • /
    • v.35 no.5
    • /
    • pp.842-849
    • /
    • 2005
  • Purpose: The main purpose of this study was to establish a nursing intervention data base to improve maternal attachment. Method: The first group of mothers( control group), experienced their first physical contact with their infants after being discharged from the hospital. The second group (experimental group) practiced early initial mother-infant postpartum contact known as the most sensitive period for founding maternal-infancy attachment. The subjects of this study gave birth to normal infants at M hospital from Aug.25 to Sept.30, 2004. During the same time, data was collected through direct observation, with instruments designed by Cropley et al., to assess the behaviors of normal attachment. The statistical methods for data analysis were percentage, mean, standard deviation and t-test with an SPSS program. Result: The group practicing initial mother-infant contact, showed a higher degree of physical and functional bonding than the group experiencing the first contact after discharge from the :10spital (control group)(p<.0l). The group practicing initial mother-infant contact, showed higher degrees of bonding attachment assessments than the group experiencing their first initial contact after their discharge from the hospital(p<.01). Conclusion: The group practicing early mother-infant contact, showed more maternal-infant interaction than the group experiencing their initial contact after their discharge from the hospital. These results show that maternal attachment behavior increases according with an early initial mother-infant contact.

Effects of Thermal Contact Resistance on Transient Thermoelastic Contacts for an Elastic Foundation (시간에 따른 탄성지지 열탄성 접촉에 대한 열접촉저항의 영향)

  • Jang, Yong-Hoon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.330-333
    • /
    • 2005
  • The paper presents a numerical solution to the problem of a hot rigid indenter siding over a thermoelastic Winkler foundation with a thermal contact resistance at constant speed. It is shown analytically that no steady-state solution can exist for sufficiently high temperature or sufficiently small normal load or speed regardless of the thermal contact resistance. However, the steady state solution may exist in the same situation if the thermal contact resistance is considered. This means that the effect of the large values of temperature difference and small value of force or velocity which occur at no steady state can be lessened due to the thermal contact resistance. When there is no steady-state the predicted transient behavior involves regions of transient stationary contact interspersed with regions of separation regardless of the thermal contact resistance. Initially, the system typically exhibits a small number of relatively large contact and separation regions, but after the initial transient the trailing edge of the contact area is only established and the leading edge loses contact, reducing the total extent of contact considerably. As time progresses, larger and larger number of small contact areas are established, until eventually the accuracy of the algorithm is limited by the discretization used.

  • PDF

The sensing characteristics of MOPS structure based on porous silicon for ethanol gas (다공질규소를 이용한 MOPS 구조의 에탄올 감지 특성)

  • Sohn, Sihn-Young;Kim, Han-Jung;Lee, Ki-Won;Kim, Young-You
    • Journal of Sensor Science and Technology
    • /
    • v.15 no.6
    • /
    • pp.457-461
    • /
    • 2006
  • To use the porous silicon as gas sensors, we made the MOPS structure from the porous silicon with Al evaporation and investigated the sensing characteristic of ethanol. When the MOPS structure is in contact with ethanol gas, the maximum peak of PL changes and it return to original intensity without contact. The MOPS structure had response time 0.78s and recovery time 4.13s when it is in contact with ethanol, which satisfied the required sensor standards. Further complimentary researches, however, are required to investigate the contact mechanism between MOPS structure and ethanol and to solve the surface contamination problem.

A Parallel Finite Element Procedure for Contact-Impact Problems (충돌해석을 위한 병렬유한요소 알고리즘)

  • Har, Jason
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.1286-1290
    • /
    • 2003
  • This paper presents a newly implemented parallel finite element procedure for contact-impact problems. Three sub-algorithms are includes in the proposed parallel contact-impact procedure, such as a parallel Belytschko-Lin-Tsay (BLT) shell element generation, a parallel explicit time integration scheme, and a parallel contact search algorithm based on the master slave slide-line algorithm. The underlying focus of the algorithms is on its effectiveness and efficiency for inclusion in future finite element systems on parallel computers. Throughout this research, a prototype code, named GT-PARADYN, is developed on the IBM SP2, a distributed-memory computer. Some numerical examples are provided to demonstrate the timing results of the procedure, discussing the accuracy and efficiency of the code.

  • PDF